{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T05:53:05Z","timestamp":1783749185875,"version":"3.55.0"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,28]],"date-time":"2025-11-28T00:00:00Z","timestamp":1764288000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,11,28]],"date-time":"2025-11-28T00:00:00Z","timestamp":1764288000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001652","name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100001652","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Vitreoretinal surgery, requiring precise microscale tissue manipulation, is well-suited for robotic assistance. Image registration enhances surgeons\u2019 visual perception by aligning high-resolution preoperative OCT images with the intraoperative environment, improving visibility of anatomical features not seen in microscope images. However, optical distortions from the cornea, lens, eye curvature, and scanning patterns challenge the use of diagnostic data in robotic navigation. This study introduces a novel technique for curvature-corrected retinal registration, integrating diagnostic OCT with instrument-integrated OCT. The pipeline comprises feature extraction, curvature correction, initial alignment, and fine registration. Experiments using an artificial model eye and ex vivo porcine eye validate the method. Curvature correction achieves accuracy comparable to existing methods, with deviations of 17\n                    <jats:inline-formula>\n                      <jats:tex-math>$$\\upmu$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    m for the model eye and 460\n                    <jats:inline-formula>\n                      <jats:tex-math>$$\\upmu$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    m for the porcine eye. Post-registration, the fiducial marker error reduces to 103\n                    <jats:inline-formula>\n                      <jats:tex-math>$$\\upmu$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    m for the model eye and 318\n                    <jats:inline-formula>\n                      <jats:tex-math>$$\\upmu$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    m for the porcine eye. Our method provides intraoperative diagnostic context, enabling reliable topological assistance in retinal robotic systems.\n                  <\/jats:p>","DOI":"10.1038\/s41598-025-28922-6","type":"journal-article","created":{"date-parts":[[2025,11,28]],"date-time":"2025-11-28T08:34:20Z","timestamp":1764318860000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Curvature-corrected retinal registration of diagnostic OCT with instrument-integrated OCT"],"prefix":"10.1038","volume":"15","author":[{"given":"Marius","family":"Briel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ludwig","family":"Haide","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Meyling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Saalfrank","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Matten","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicola","family":"Piccinelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gernot","family":"Kronreif","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Francesca","family":"Spadea","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eleonora","family":"Tagliabue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Franziska","family":"Mathis-Ullrich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,11,28]]},"reference":[{"key":"28922_CR1","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1007\/s10384-024-01127-6","volume":"68","author":"R Matoba","year":"2024","unstructured":"Matoba, R. & Morizane, Y. Epiretinal membrane: An overview and update. Jpn. J. Ophthalmol. 68, 603\u2013613. https:\/\/doi.org\/10.1007\/s10384-024-01127-6 (2024).","journal-title":"Jpn. J. Ophthalmol."},{"key":"28922_CR2","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1007\/s00417-003-0624-x","volume":"241","author":"S Charles","year":"2003","unstructured":"Charles, S. Techniques and tools for dissection of epiretinal membranes. Graefe\u2019s Arch. Clin. Experimental Ophthalmol. 241, 347\u2013352. https:\/\/doi.org\/10.1007\/s00417-003-0624-x (2003).","journal-title":"Graefe\u2019s Arch. Clin. Experimental Ophthalmol."},{"key":"28922_CR3","doi-asserted-by":"publisher","first-page":"2114","DOI":"10.1007\/s12325-021-01692-z","volume":"38","author":"EZ Ahronovich","year":"2021","unstructured":"Ahronovich, E. Z., Simaan, N. & Joos, K. A review of robotic and OCT-aided systems for vitreoretinal surgery. Adv. Ther. 38, 2114\u20132129. https:\/\/doi.org\/10.1007\/s12325-021-01692-z (2021).","journal-title":"Adv. Ther."},{"key":"28922_CR4","doi-asserted-by":"publisher","DOI":"10.1016\/j.xops.2021.100085","author":"MG Cereda","year":"2021","unstructured":"Cereda, M. G. et al. Clinical evaluation of an instrument-integrated OCT-based distance sensor for robotic vitreoretinal surgery. Ophthalmol. Sci. https:\/\/doi.org\/10.1016\/j.xops.2021.100085 (2021).","journal-title":"Ophthalmol. Sci."},{"key":"28922_CR5","doi-asserted-by":"publisher","unstructured":"Balicki, M. et al. Single fiber optical coherence tomography microsurgical instruments for computer and robot-assisted retinal surgery. In: Medical Image Computing and Computer-Assisted Intervention - MICCAI 2009, vol.\u00a012, 108\u2013115. https:\/\/doi.org\/10.1007\/978-3-642-04268-3_14 (2009).","DOI":"10.1007\/978-3-642-04268-3_14"},{"key":"28922_CR6","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1364\/BOE.6.000457","volume":"6","author":"H Yu","year":"2015","unstructured":"Yu, H., Shen, J.-H., Shah, R. J., Simaan, N. & Joos, K. M. Evaluation of microsurgical tasks with OCT-guided and\/or robot-assisted ophthalmic forceps. Biomed. Opt. Express 6, 457\u2013472. https:\/\/doi.org\/10.1364\/BOE.6.000457 (2015).","journal-title":"Biomed. Opt. Express"},{"key":"28922_CR7","doi-asserted-by":"publisher","DOI":"10.1109\/TMRB.2025.3604119","author":"M Briel","year":"2025","unstructured":"Briel, M. et al. Intraoperative 3D reconstruction and geometric modeling using sensorized microsurgical instruments. IEEE Trans. Med. Robot. Bionics https:\/\/doi.org\/10.1109\/TMRB.2025.3604119 (2025).","journal-title":"IEEE Trans. Med. Robot. Bionics"},{"key":"28922_CR8","doi-asserted-by":"publisher","first-page":"818","DOI":"10.3390\/clinpract12050086","volume":"12","author":"A Ashurov","year":"2022","unstructured":"Ashurov, A. et al. Real-time (iOCT) guided epiretinal membrane surgery using a novel forceps with laser-ablated microstructure tip surface. Clin. Practice 12, 818\u2013825. https:\/\/doi.org\/10.3390\/clinpract12050086 (2022).","journal-title":"Clin. Practice"},{"key":"28922_CR9","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1364\/OE.19.000007","volume":"19","author":"Y Li","year":"2011","unstructured":"Li, Y., Gregori, G., Knighton, R. W., Lujan, B. J. & Rosenfeld, P. J. Registration of OCT fundus images with color fundus photographs based on blood vessel ridges. Opt. Express 19, 7\u201316. https:\/\/doi.org\/10.1364\/OE.19.000007 (2011).","journal-title":"Opt. Express"},{"key":"28922_CR10","doi-asserted-by":"publisher","unstructured":"Kamasi, Z.\u00a0G., Mokhtari, M. & Rabbani, H. Non-rigid registration of fluorescein angiography and optical coherence tomography via scanning laser ophthalmoscope imaging. In 39th International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 4415\u20134418. https:\/\/doi.org\/10.1109\/EMBC.2017.8037835 (2017).","DOI":"10.1109\/EMBC.2017.8037835"},{"key":"28922_CR11","doi-asserted-by":"publisher","unstructured":"Fleming, I. et al. Intraoperative visualization of anatomical targets in retinal surgery. In 2008 IEEE Workshop on Applications of Computer Vision, 1\u20136. https:\/\/doi.org\/10.1109\/WACV.2008.4544034 (2008).","DOI":"10.1109\/WACV.2008.4544034"},{"key":"28922_CR12","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1109\/RBME.2021.3110958","volume":"16","author":"L Pan","year":"2021","unstructured":"Pan, L. & Chen, X. Retinal OCT image registration: Methods and applications. IEEE Rev. Biomed. Eng. 16, 307\u2013318. https:\/\/doi.org\/10.1109\/RBME.2021.3110958 (2021).","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"28922_CR13","doi-asserted-by":"publisher","first-page":"3885","DOI":"10.1109\/TIP.2020.2967589","volume":"29","author":"L Pan","year":"2020","unstructured":"Pan, L. et al. OCTRexpert: A feature-based 3D registration method for retinal OCT images. IEEE Trans. Image Process. 29, 3885\u20133897. https:\/\/doi.org\/10.1109\/TIP.2020.2967589 (2020).","journal-title":"IEEE Trans. Image Process."},{"key":"28922_CR14","doi-asserted-by":"publisher","first-page":"3726","DOI":"10.1364\/BOE.493047","volume":"14","author":"D Rivas-Villar","year":"2023","unstructured":"Rivas-Villar, D. et al. Automated inter-device 3D OCT image registration using deep learning and retinal layer segmentation. Biomed. Opt. Express 14, 3726\u20133747. https:\/\/doi.org\/10.1364\/BOE.493047 (2023).","journal-title":"Biomed. Opt. Express"},{"key":"28922_CR15","doi-asserted-by":"publisher","first-page":"1153","DOI":"10.1109\/TMI.2013.2265603","volume":"32","author":"A Sotiras","year":"2013","unstructured":"Sotiras, A., Davatzikos, C. & Paragios, N. Deformable medical image registration: A survey. IEEE Trans. Med. Imaging 32, 1153\u20131190. https:\/\/doi.org\/10.1109\/TMI.2013.2265603 (2013).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"28922_CR16","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1007\/s11548-023-02960-9","volume":"19","author":"P Liu","year":"2024","unstructured":"Liu, P. et al. Non-rigid point cloud registration for middle ear diagnostics with endoscopic optical coherence tomography. Int. J. Comput. Assist. Radiol. Surg. 19, 139\u2013145. https:\/\/doi.org\/10.1007\/s11548-023-02960-9 (2024).","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"28922_CR17","doi-asserted-by":"publisher","DOI":"10.1117\/12.2306604","author":"MAJ Steidle","year":"2018","unstructured":"Steidle, M. A. J. & Straub, J. Estimating the shape of the human eye using widefield optical coherence tomography. In Biophotonics: Photonic Solutions for Better Health Care VI https:\/\/doi.org\/10.1117\/12.2306604 (2018).","journal-title":"In Biophotonics: Photonic Solutions for Better Health Care VI"},{"key":"28922_CR18","first-page":"PB034","volume":"60","author":"J Bumstead","year":"2019","unstructured":"Bumstead, J., Steidle, M., Leahy, C. & Straub, J. Repeatability of retinal curvature estimation on wide field OCT systems. Invest. Ophthalmol. Vis. Sci. 60, PB034 (2019).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"28922_CR19","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1016\/j.ajo.2013.03.012","volume":"156","author":"AN Kuo","year":"2013","unstructured":"Kuo, A. N. et al. Correction of ocular shape in retinal optical coherence tomography and effect on current clinical measures. Am. J. Ophthalmol. 156, 304\u2013311. https:\/\/doi.org\/10.1016\/j.ajo.2013.03.012 (2013).","journal-title":"Am. J. Ophthalmol."},{"key":"28922_CR20","doi-asserted-by":"publisher","first-page":"1070","DOI":"10.1364\/BOE.447595","volume":"13","author":"R Grytz","year":"2022","unstructured":"Grytz, R. et al. Nonlinear distortion correction for posterior eye segment optical coherence tomography with application to tree shrews. Biomed. Opt. Exp. 13, 1070\u20131086. https:\/\/doi.org\/10.1364\/BOE.447595 (2022).","journal-title":"Biomed. Opt. Exp."},{"key":"28922_CR21","doi-asserted-by":"publisher","DOI":"10.1016\/j.compmedimag.2025.102539","author":"H Zhang","year":"2025","unstructured":"Zhang, H. et al. Retinal OCT image segmentation with deep learning: A review of advances, datasets, and evaluation metrics. Comput. Med. Imaging .Graph. https:\/\/doi.org\/10.1016\/j.compmedimag.2025.102539 (2025).","journal-title":"Comput. Med. Imaging .Graph."},{"key":"28922_CR22","doi-asserted-by":"publisher","first-page":"881","DOI":"10.1007\/s11548-025-03325-0","volume":"20","author":"M Briel","year":"2025","unstructured":"Briel, M. et al. Intraoperative adaptive eye model based on instrument-integrated OCT for robot-assisted vitreoretinal surgery. Int. J. Comput.-Assist. Radiol. Surg. 20, 881\u2013889. https:\/\/doi.org\/10.1007\/s11548-025-03325-0 (2025).","journal-title":"Int. J. Comput.-Assist. Radiol. Surg."},{"key":"28922_CR23","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/503645","author":"I Bekerman","year":"2014","unstructured":"Bekerman, I., Gottlieb, P. & Vaiman, M. Variations in eyeball diameters of the healthy adults. J. Ophthalmol. https:\/\/doi.org\/10.1155\/2014\/503645 (2014).","journal-title":"J. Ophthalmol."},{"key":"28922_CR24","doi-asserted-by":"publisher","unstructured":"Rusinkiewicz, S. & Levoy, M. Efficient variants of the ICP algorithm. In Proceedings Third International Conference on 3-D Digital Imaging and Modeling, 145\u2013152. https:\/\/doi.org\/10.1109\/IM.2001.924423 (2001).","DOI":"10.1109\/IM.2001.924423"},{"key":"28922_CR25","doi-asserted-by":"publisher","first-page":"2269","DOI":"10.1109\/TPAMI.2020.2971687","volume":"43","author":"O Hirose","year":"2021","unstructured":"Hirose, O. A bayesian formulation of coherent point drift. IEEE Trans. Pattern Anal. Mach. Intell. 43, 2269\u20132286. https:\/\/doi.org\/10.1109\/TPAMI.2020.2971687 (2021).","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"28922_CR26","doi-asserted-by":"publisher","unstructured":"Beauchemin, M. L. The fine structure of the pig\u2019s retina. Albrecht von Graefes Archiv f\u00fcr Klinische und Experimentelle Ophthalmologie. 190, 27\u201345. https:\/\/doi.org\/10.1007\/BF00414333 (1974).","DOI":"10.1007\/BF00414333"},{"key":"28922_CR27","doi-asserted-by":"publisher","DOI":"10.1109\/TMRB.2025.3583133","author":"N Piccinelli","year":"2025","unstructured":"Piccinelli, N. et al. GEYEDANCE: An OCT-enhanced multi-modal feedback platform for robot-assisted ophthalmic surgery. IEEE Trans. Med. Robot. Bionics https:\/\/doi.org\/10.1109\/TMRB.2025.3583133 (2025).","journal-title":"IEEE Trans. Med. Robot. Bionics"},{"key":"28922_CR28","doi-asserted-by":"publisher","first-page":"352","DOI":"10.1364\/BOE.483278","volume":"14","author":"JD Li","year":"2023","unstructured":"Li, J. D. et al. Quantitative measurements of intraocular structures and microinjection bleb volumes using intraoperative optical coherence tomography. Biomed. Opt. Express 14, 352\u2013366. https:\/\/doi.org\/10.1364\/BOE.483278 (2023).","journal-title":"Biomed. Opt. Express"},{"key":"28922_CR29","doi-asserted-by":"publisher","first-page":"3944","DOI":"10.1109\/LRA.2018.2858744","volume":"3","author":"M Zhou","year":"2018","unstructured":"Zhou, M. et al. Towards robotic eye surgery: Marker-free, online hand-eye calibration using optical coherence tomography images. IEEE Robot. Autom. Lett. 3, 3944\u20133951. https:\/\/doi.org\/10.1109\/LRA.2018.2858744 (2018).","journal-title":"IEEE Robot. Autom. Lett."},{"key":"28922_CR30","doi-asserted-by":"publisher","first-page":"4815","DOI":"10.1364\/BOE.10.004815","volume":"10","author":"K Breher","year":"2019","unstructured":"Breher, K., Agarwala, R., Leube, A. & Wahl, S. Direct modeling of foveal pit morphology from distortion-corrected OCT images. Biomed. Opt. Express 10, 4815\u20134824. https:\/\/doi.org\/10.1364\/BOE.10.004815 (2019).","journal-title":"Biomed. Opt. Express"},{"key":"28922_CR31","doi-asserted-by":"publisher","first-page":"3908","DOI":"10.1167\/iovs.10-6738","volume":"52","author":"R de Kinkelder","year":"2011","unstructured":"de Kinkelder, R. et al. Heartbeat-induced axial motion artifacts in optical coherence tomography measurements of the retina. Invest. Ophthalmol. Vis. Sci. 52, 3908\u20133913. https:\/\/doi.org\/10.1167\/iovs.10-6738 (2011).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"28922_CR32","doi-asserted-by":"publisher","first-page":"1705","DOI":"10.1109\/JPROC.2006.880722","volume":"94","author":"C Riviere","year":"2006","unstructured":"Riviere, C., Gangloff, J. & De Mathelin, M. Robotic compensation of biological motion to enhance surgical accuracy. Proc. IEEE 94, 1705\u20131716. https:\/\/doi.org\/10.1109\/JPROC.2006.880722 (2006).","journal-title":"Proc. IEEE"},{"key":"28922_CR33","doi-asserted-by":"publisher","first-page":"1324","DOI":"10.1097\/IAE.0b013e31823bea54","volume":"32","author":"CA McCannel","year":"2012","unstructured":"McCannel, C. A. et al. Snoring is associated with unexpected patient head movement during monitored anesthesia care vitreoretinal surgery. Retina 32, 1324\u20131327. https:\/\/doi.org\/10.1097\/IAE.0b013e31823bea54 (2012).","journal-title":"Retina"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-28922-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-28922-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-28922-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,2]],"date-time":"2025-12-02T10:35:11Z","timestamp":1764671711000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-28922-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,28]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["28922"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-28922-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,28]]},"assertion":[{"value":"8 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"42933"}}