{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T03:21:03Z","timestamp":1787628063647,"version":"build-2736575974"},"reference-count":51,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T00:00:00Z","timestamp":1764374400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T00:00:00Z","timestamp":1767657600000},"content-version":"vor","delay-in-days":38,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-025-30103-4","type":"journal-article","created":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T20:44:46Z","timestamp":1764449086000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Evaluation of a flexible thyroid shield in dental panoramic radiography utilizing bismuth oxide silicone rubber composite and Rando phantom"],"prefix":"10.1038","volume":"16","author":[{"given":"Leila","family":"Shahbazi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dariush","family":"Sardari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shahryar","family":"Malekie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohsen Kheradmand","family":"Saadi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sedigheh","family":"Kashian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,11,29]]},"reference":[{"key":"30103_CR1","doi-asserted-by":"publisher","first-page":"20150407","DOI":"10.1259\/dmfr.20150407","volume":"45","author":"RC Hoogeveen","year":"2016","unstructured":"Hoogeveen, R. C., Hazenoot, B., Sanderink, G. C. H. & Berkhout, W. E. R. The value of thyroid shielding in intraoral radiography. Dentomaxillofacial Radiol. 45, 20150407 (2016).","journal-title":"Dentomaxillofacial Radiol."},{"key":"30103_CR2","unstructured":"Aghaz, A., Kardan, M. R., Deevband, M. R. & Bahadorzadeh, B. Organ and size-specific Effective Doses from Dental Cone Beam CT Based on Body Mass Indexes (BMIs) (Monte-Carlo simulation study, 2024)."},{"key":"30103_CR3","doi-asserted-by":"publisher","first-page":"P10011","DOI":"10.1088\/1748-0221\/16\/10\/P10011","volume":"16","author":"A Aghaz","year":"2021","unstructured":"Aghaz, A. et al. Patient-specific dose assessment using CBCT images and Monte Carlo calculations. J. Instrum. 16, P10011 (2021).","journal-title":"J. Instrum."},{"key":"30103_CR4","first-page":"224","volume":"15","author":"A Aghaz","year":"2018","unstructured":"Aghaz, A., Kardan, M. R., Deevband, M. R. & Bahadorzadeh, B. Comparison of two different methods for CTDIw calculation in CBCT systems. Iran. J. Med. Phys. 15, 224\u2013224 (2018).","journal-title":"Iran. J. Med. Phys."},{"key":"30103_CR5","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1007\/s00784-010-0402-1","volume":"15","author":"DA Ribeiro","year":"2011","unstructured":"Ribeiro, D. A., Sannomiya, E. K., Pozzi, R., Miranda, S. R. & Angelieri, F. Cellular death but not genetic damage in oral mucosa cells after exposure to digital lateral radiography. Clin. Oral Invest. 15, 357\u2013360 (2011).","journal-title":"Clin. Oral Invest."},{"key":"30103_CR6","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.ejmp.2010.12.003","volume":"28","author":"C Walker","year":"2012","unstructured":"Walker, C. & van der Putten, W. Patient dosimetry and a novel approach to Establishing diagnostic reference levels in dental radiology. Physica Med. 28, 7\u201312 (2012).","journal-title":"Physica Med."},{"key":"30103_CR7","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1038\/sj.ebd.6400852","volume":"13","author":"E Abt","year":"2012","unstructured":"Abt, E. Can dental x-rays increase the risk of meningioma? Evid.-Based Dent. 13, 37\u201338 (2012).","journal-title":"Evid.-Based Dent."},{"key":"30103_CR8","doi-asserted-by":"publisher","first-page":"ii98","DOI":"10.1093\/jrr\/rrx054","volume":"59","author":"Y Nagayama","year":"2018","unstructured":"Nagayama, Y. Radiation-related thyroid autoimmunity and dysfunction. J. Radiat. Res. 59, ii98\u2013ii107 (2018).","journal-title":"J. Radiat. Res."},{"key":"30103_CR9","doi-asserted-by":"publisher","first-page":"2939","DOI":"10.3390\/tomography8060247","volume":"8","author":"MM Abuzaid","year":"2022","unstructured":"Abuzaid, M. M., Elshami, W., Jayachandran, D., Korappil, N. & Tekin, H. O. Establishment of diagnostic reference levels in cone beam computed tomography scans in the united Arab Emirates. Tomography 8, 2939\u20132945 (2022).","journal-title":"Tomography"},{"key":"30103_CR10","doi-asserted-by":"publisher","first-page":"20170428","DOI":"10.1259\/dmfr.20170428","volume":"47","author":"L Hafezi","year":"2018","unstructured":"Hafezi, L., Arianezhad, S. M., Hosseini, S. M. & Pooya Evaluation of the radiation dose in the thyroid gland using different protective collars in panoramic imaging. Dentomaxillofacial Radiol. 47, 20170428 (2018).","journal-title":"Dentomaxillofacial Radiol."},{"key":"30103_CR11","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/j.oooo.2022.03.002","volume":"134","author":"M Gr\u00fcning","year":"2022","unstructured":"Gr\u00fcning, M., Koivisto, J., Mah, J. & Bumann, A. Impact of thyroid gland shielding on radiation doses in dental cone beam computed tomography with small and medium fields of view. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. 134, 245\u2013253 (2022).","journal-title":"Oral Surg. Oral Med. Oral Pathol. Oral Radiol."},{"key":"30103_CR12","doi-asserted-by":"publisher","first-page":"10614","DOI":"10.1038\/s41598-021-89773-5","volume":"11","author":"R Mehrara","year":"2021","unstructured":"Mehrara, R., Malekie, S., Saleh Kotahi, S. M. & Kashian, S. Introducing a novel low energy gamma ray shield utilizing polycarbonate bismuth oxide composite. Sci. Rep. 11, 10614 (2021).","journal-title":"Sci. Rep."},{"key":"30103_CR13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-022-13556-9","volume":"12","author":"S Malekie","year":"2022","unstructured":"Malekie, S., Shooli, H. & Hosseini, M. A. Assessment of new composites containing polyamide-6 and lead monoxide as shields against ionizing photonic radiation based on computational and experimental methods. Sci. Rep. 12, 1\u201315 (2022).","journal-title":"Sci. Rep."},{"key":"30103_CR14","doi-asserted-by":"publisher","first-page":"166214","DOI":"10.1016\/j.nima.2021.166214","volume":"1026","author":"MA Hosseini","year":"2022","unstructured":"Hosseini, M. A., Malekie, S. & Kazemi, F. Experimental evaluation of gamma radiation shielding characteristics of Polyvinyl Alcohol\/Tungsten oxide composite: A comparison study of micro and nano sizes of the fillers. Nucl. Instrum. Methods Phys. Res., Sect. A. 1026, 166214 (2022).","journal-title":"Nucl. Instrum. Methods Phys. Res., Sect. A"},{"key":"30103_CR15","doi-asserted-by":"publisher","first-page":"273","DOI":"10.4103\/jmp.JMP_54_17","volume":"42","author":"K Srinivasan","year":"2017","unstructured":"Srinivasan, K. & Samuel, E. J. J. Evaluation of radiation shielding properties of the Polyvinyl alcohol\/iron oxide polymer composite. J. Med. Phys. 42, 273 (2017).","journal-title":"J. Med. Phys."},{"key":"30103_CR16","doi-asserted-by":"crossref","unstructured":"More, C. V., Alsayed, Z., Badawi, M. S., Thabet, A. A. & Pawar, P. P. Polymeric composite materials for radiation shielding: a review. Environ. Chem. Lett. 19, 1\u201334 (2021).","DOI":"10.1007\/s10311-021-01189-9"},{"key":"30103_CR17","doi-asserted-by":"publisher","first-page":"164174","DOI":"10.1016\/j.nima.2020.164174","volume":"973","author":"L Gholamzadeh","year":"2020","unstructured":"Gholamzadeh, L., Asari-Shik, N., Aminian, M. K. & Ghasemi-Nejad, M. A study of the shielding performance of fibers coated with high-Z oxides against ionizing radiations. Nucl. Instrum. Methods Phys. Res., Sect. A. 973, 164174 (2020).","journal-title":"Nucl. Instrum. Methods Phys. Res., Sect. A"},{"key":"30103_CR18","unstructured":"https:\/\/www.meddeal.in\/91701-thyroid-collar-standard.html"},{"key":"30103_CR19","unstructured":"Orthopantomograph, O. P. 200 D user manual, 5139796-100 rev. 7, PaloDEx Group Oy, (Tuusula, FINLAND, 2012)."},{"key":"30103_CR20","unstructured":"International Electrotechnical Commission. IEC 61267: Medical diagnostic x-ray equipment \u2013 Radiation conditions for use in the determination of characteristics. Geneva, (2005)."},{"key":"30103_CR21","unstructured":"Cember, H. & Johnson, T. E. Introduction to health physics, NNRA Library 2009."},{"key":"30103_CR22","unstructured":"Protection, Radiological, I. C. R. P. publication 103, Ann ICRP, 37, 2 (2007)."},{"key":"30103_CR23","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.apradiso.2016.09.001","volume":"118","author":"R Casanovas","year":"2016","unstructured":"Casanovas, R., Prieto, E. & Salvad\u00f3, M. Calculation of the ambient dose equivalent H*(10) from gamma-ray spectra obtained with scintillation detectors. Appl. Radiat. Isot. 118, 154\u2013159 (2016).","journal-title":"Appl. Radiat. Isot."},{"key":"30103_CR24","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1177\/0146645315624341","volume":"45","author":"A Endo","year":"2016","unstructured":"Endo, A. & On behalf of ICRU Report Committee 26 on Operational Radiation Protection Quantities for External Radiation. Operational quantities and new approach by ICRU. Ann. ICRP. 45, 178\u2013187 (2016).","journal-title":"Ann. ICRP"},{"key":"30103_CR25","unstructured":"Gualdrini, G. F. & Morelli, B. Air kerma to personal dose equivalent conversion factors for the ICRU and ISO recommended slab phantoms for photons from 20\u00a0keV to 1 MeV (SCAN-9701110, 1996)."},{"key":"30103_CR26","unstructured":"International Atomic Energy Agency. International Labour Office, Occupational Radiation Protection, IAEA Safety Standards Series No. GSG-7 (IAEA, 2018)."},{"key":"30103_CR27","unstructured":"The Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann. ICRP ; 37 1\u2013332, (2007)."},{"key":"30103_CR28","doi-asserted-by":"publisher","first-page":"4375","DOI":"10.1088\/0031-9155\/51\/17\/016","volume":"51","author":"H Hasanzadeh","year":"2006","unstructured":"Hasanzadeh, H., Sharafi, A., Verdi, M. A. & Nikoofar, A. Assessment of absorbed dose to thyroid, Parotid and ovaries in patients undergoing gamma knife radiosurgery. Phys. Med. Biol. 51, 4375 (2006).","journal-title":"Phys. Med. Biol."},{"key":"30103_CR29","first-page":"227","volume":"2","author":"M Moafi","year":"2015","unstructured":"Moafi, M., Geraily, G., Shirazi, A. R. & Teimouri, J. Analysis of TLD-100 calibration and correction factor in different field sizes under low dose conditions irradiated with two systems: gamma knife 4\u00a0C and theratron 780-C. Front. Biomedical Technol. 2, 227\u2013236 (2015).","journal-title":"Front. Biomedical Technol."},{"key":"30103_CR30","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1016\/j.jallcom.2017.02.252","volume":"706","author":"XH Gong","year":"2017","unstructured":"Gong, X. H. et al. Improved self-supporting property of ceramifying silicone rubber composites by forming crystalline phase at high temperatures. J. Alloys Compd. 706, 322\u2013329 (2017).","journal-title":"J. Alloys Compd."},{"key":"30103_CR31","doi-asserted-by":"crossref","unstructured":"Zhou, X., Zhang, Y., Shi, X. & Fan, D. Preparation, characterization, and Preliminary Biocompatibility Evaluation of Carbon ion-implanted Silicone Rubber (in: Elastomers, 2017).","DOI":"10.5772\/intechopen.69251"},{"key":"30103_CR32","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1016\/j.jtusci.2015.01.009","volume":"9","author":"H Oudghiri-Hassani","year":"2015","unstructured":"Oudghiri-Hassani, H. et al. Synthesis, characterization and photocatalytic activity of \u03b1-Bi2O3 nanoparticles. J. Taibah Univ. Sci. 9, 508\u2013512 (2015).","journal-title":"J. Taibah Univ. Sci."},{"key":"30103_CR33","doi-asserted-by":"publisher","first-page":"78299","DOI":"10.1039\/C5RA12760B","volume":"5","author":"S Sindhu","year":"2015","unstructured":"Sindhu, S. \u03b1-Bi2O3 photoanode in DSSC and study of the electrode\u2013electrolyte interface. RSC Adv. 5, 78299\u201378305 (2015).","journal-title":"RSC Adv."},{"key":"30103_CR34","doi-asserted-by":"publisher","first-page":"1760040","DOI":"10.1142\/S0219581X17600407","volume":"17","author":"M Malligavathy","year":"2018","unstructured":"Malligavathy, M., Pathinettam, D. & Padiyan Phase purity analysis and optical studies of Bi2O3 nanoparticles suitable for photocatalytic activity. Int. J. Nanosci. 17, 1760040 (2018).","journal-title":"Int. J. Nanosci."},{"key":"30103_CR35","doi-asserted-by":"publisher","first-page":"110743","DOI":"10.1016\/j.radphyschem.2022.110743","volume":"205","author":"S Malekie","year":"2023","unstructured":"Malekie, S., Kashian, S., Akhavan, A., Kheradmand, M. & Saadi Preliminary study of a novel radiation shield for jaw in dental radiography using the high-density polyethylene\/bismuth oxide nanocomposite. Radiat. Phys. Chem. 205, 110743 (2023).","journal-title":"Radiat. Phys. Chem."},{"key":"30103_CR36","doi-asserted-by":"crossref","unstructured":"Tariq, M. A. & Paracha, M. F. Evaluation of measurement uncertainty for testing & calibration laboratories as per ISO\/IEC 17025: 2017 standard requirements. IEEEP New. Horizons J., 103 (2023).","DOI":"10.61514\/ieeep.v103i2.173"},{"key":"30103_CR37","doi-asserted-by":"publisher","first-page":"20130265","DOI":"10.1259\/dmfr.20130265","volume":"42","author":"GS Han","year":"2013","unstructured":"Han, G. S., Cheng, J. G., Li, G. & Ma, X. C. Shielding effect of thyroid collar for digital panoramic radiography. Dentomaxillofacial Radiol. 42, 20130265 (2013).","journal-title":"Dentomaxillofacial Radiol."},{"key":"30103_CR38","first-page":"101102","volume":"17","author":"O Bawazeer","year":"2024","unstructured":"Bawazeer, O. et al. Radiation protection in dental imaging: evaluating the impact of the SABA thyroid shield during panoramic and cone beam computed tomography. J. Radiation Res. Appl. Sci. 17, 101102 (2024).","journal-title":"J. Radiation Res. Appl. Sci."},{"key":"30103_CR39","doi-asserted-by":"publisher","first-page":"569","DOI":"10.31661\/jbpe.v0i0.878","volume":"10","author":"A Ahmadi","year":"2020","unstructured":"Ahmadi, A., Negarestani, A., Sina, S. & Sarshough, S. Measurement of entrance skin dose and the dose received by different organs in panoramic dental imaging. J. Biomedical Phys. Eng. 10, 569 (2020).","journal-title":"J. Biomedical Phys. Eng."},{"key":"30103_CR40","unstructured":"Moghadam, A. E., Mardani, M., Hasanzadeh, H. & Rafati, M. Assessment of absorbed dose in critical organs in OPG: a Phantom study. Archives Adv. Biosci., 6, 44-49 (2015)."},{"key":"30103_CR41","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1093\/rpd\/ncy159","volume":"183","author":"W Qiang","year":"2019","unstructured":"Qiang, W., Qiang, F. & Lin, L. Estimation of effective dose of dental X-ray devices. Radiat. Prot. Dosimetry. 183, 418\u2013422 (2019).","journal-title":"Radiat. Prot. Dosimetry"},{"key":"30103_CR42","unstructured":"ASTM Designation F3094\u201314. Standard test method for determining protection provided by X-ray shielding garments used in medical x-ray fluoroscopy from sources of scattered X-rays, American society for testing and materials international, 100 Barr Harbor Drive, (2022)."},{"key":"30103_CR43","doi-asserted-by":"publisher","first-page":"102980","DOI":"10.1016\/j.radi.2025.102980","volume":"31","author":"L Hafezi","year":"2025","unstructured":"Hafezi, L., Aghaz, A., Deevband, M. R. & Vaezi, S. Investigating the effect of thyroid shields and lead glasses on image quality and artefacts in cone beam computed tomography devices: A Phantom study. Radiography 31, 102980 (2025).","journal-title":"Radiography"},{"key":"30103_CR44","doi-asserted-by":"publisher","first-page":"231","DOI":"10.4103\/jiaomr.jiaomr_14_23","volume":"35","author":"D Sugumaran","year":"2023","unstructured":"Sugumaran, D. & Aswath, N. Evaluation of thyroid dosimetry using a novel modified thyroid collar during digital panoramic radiography and cone beam computed tomography-a cross-sectional study. J. Indian Acad. Oral Med. Radiol. 35, 231\u2013235 (2023).","journal-title":"J. Indian Acad. Oral Med. Radiol."},{"key":"30103_CR45","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/j.ejrad.2005.05.011","volume":"56","author":"K Tsiklakis","year":"2005","unstructured":"Tsiklakis, K. et al. Dose reduction in maxillofacial imaging using low dose cone beam CT. Eur. J. Radiol. 56, 413\u2013417 (2005).","journal-title":"Eur. J. Radiol."},{"key":"30103_CR46","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s13244-014-0379-4","volume":"6","author":"A Suomalainen","year":"2015","unstructured":"Suomalainen, A., Pakbaznejad Esmaeili, E. & Robinson, S. Dentomaxillofacial imaging with panoramic views and cone beam CT. Insights into Imaging. 6, 1\u201316 (2015).","journal-title":"Insights into Imaging"},{"key":"30103_CR47","unstructured":"Dula, K., Mini, R., van der Stelt, P. F. & Buser, D. The radiographic assessment of implant patients: decision-making criteria. Int. J. Oral Maxillofacial Implants, 16 (2001)."},{"key":"30103_CR48","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1007\/s003300100928","volume":"12","author":"M Cohnen","year":"2002","unstructured":"Cohnen, M., Kemper, J., M\u00f6bes, O., Pawelzik, J. & M\u00f6dder, U. Radiation dose in dental radiology. Eur. Radiol. 12, 634\u2013637 (2002).","journal-title":"Eur. Radiol."},{"key":"30103_CR49","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1093\/rpd\/ncae221","volume":"201","author":"H Vafapour","year":"2025","unstructured":"Vafapour, H., Panah, S., Rafiepour, P. & Panahi, S. R. Assessment of thyroid dose in orthopantomogram imaging with different thyroid shield materials: a Monte Carlo simulation study. Radiat. Prot. Dosimetry. 201, 48\u201355 (2025).","journal-title":"Radiat. Prot. Dosimetry"},{"key":"30103_CR50","doi-asserted-by":"crossref","unstructured":"Aytugar, E. et al. Are bismuth shields useful in dentomaxillofacial radiology practice for the protection of eyes and thyroid glands from ionizing radiation? Iran. J. Radiol., 15, 1-6 (2018).","DOI":"10.5812\/iranjradiol.40723"},{"key":"30103_CR51","doi-asserted-by":"publisher","first-page":"e376","DOI":"10.1016\/j.ejrad.2011.11.048","volume":"81","author":"X Qu","year":"2012","unstructured":"Qu, X., Li, G., Zhang, Z. & Ma, X. Thyroid shields for radiation dose reduction during cone beam computed tomography scanning for different oral and maxillofacial regions. Eur. J. Radiol. 81, e376\u2013e380 (2012).","journal-title":"Eur. J. Radiol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-30103-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-30103-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-30103-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T13:35:52Z","timestamp":1767706552000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-30103-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,29]]},"references-count":51,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["30103"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-30103-4","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,29]]},"assertion":[{"value":"30 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"541"}}