{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T18:09:48Z","timestamp":1787162988024,"version":"build-2736575974"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T00:00:00Z","timestamp":1765324800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T00:00:00Z","timestamp":1768435200000},"content-version":"vor","delay-in-days":36,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002241","name":"Japan Science and Technology Agency","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002241","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>To overcome the operator-dependence of ultrasound (US) imaging, robotic US systems have been widely developed for fully automated scanning. In this study, toward fully automated screening of gallbladder in abdominal US examinations, we propose a scan path planning method and a probe posture control strategy using our robotic US system. The path planning method uses an RGB-D camera to capture changes in the patient\u2019s chest height position due to breathing. This allows the boundary line of the subcostal, which is an important landmark for the gallbladder scan, to be identified, and the scanning path for the robot is automatically generated. Regarding the probe posture control strategy, for proper contact between the probe and the body surface, we combine probe posture control with body surface normal estimation using the RGB-D camera before scanning and deep learning-based visual servoing to avoid shadows during scanning. These were implemented in our robotic US system and feasibility experiments were conducted on six healthy subjects. When the path planning method and the posture control strategy proposed in this study were applied, the detection rate of the gallbladder was 78.3%. These results demonstrate the possibility of fully automated gallbladder screening using the proposed system.<\/jats:p>","DOI":"10.1038\/s41598-025-31892-4","type":"journal-article","created":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T09:14:29Z","timestamp":1765358069000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Fully automated robotic ultrasound gallbladder imaging with subcostal scanning"],"prefix":"10.1038","volume":"16","author":[{"given":"Koudai","family":"Okuzaki","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norihiro","family":"Koizumi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shota","family":"Takahashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryota","family":"Masuzaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoki","family":"Matsumoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahiro","family":"Ogawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiyoshi","family":"Yoshinaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryosuke","family":"Tsumura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,10]]},"reference":[{"key":"31892_CR1","doi-asserted-by":"publisher","first-page":"371","DOI":"10.5405\/jmbe.871","volume":"31","author":"K Shung","year":"2011","unstructured":"Shung, K. Diagnostic ultrasound: Past, present, and future. J. Med. Biol. Eng. 31, 371\u2013374 (2011).","journal-title":"J. Med. Biol. Eng."},{"key":"31892_CR2","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1148\/radiol.2412051710","volume":"241","author":"WA Berg","year":"2006","unstructured":"Berg, W. A., Blume, J. D., Cormack, J. B. & Mendelson, E. B. Operator dependence of physician-performed whole-breast US: Lesion detection and characterization. Radiology 241, 355\u2013365 (2006).","journal-title":"Radiology"},{"key":"31892_CR3","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1539\/joh.17-0057-OA","volume":"59","author":"D Zhang","year":"2017","unstructured":"Zhang, D. & Huang, H. Prevalence of work-related musculoskeletal disorders among sonographers in china: Results from a National web-based survey. J. Occup. Health 59, 529\u2013541. https:\/\/doi.org\/10.1539\/joh.17-0057-OA (2017).","journal-title":"J. Occup. Health"},{"key":"31892_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/00140139.2020.1811401","volume":"64","author":"K Sweeney","year":"2020","unstructured":"Sweeney, K., O\u2019Connor, C., Hewson, D. & Hellyer, R. The effectiveness of ergonomics interventions in reducing upper limb work-related musculoskeletal pain and dysfunction in sonographers, surgeons and dentists: A systematic review. Ergonomics 64, 1\u201338 (2020).","journal-title":"Ergonomics"},{"key":"31892_CR5","doi-asserted-by":"publisher","first-page":"510","DOI":"10.1109\/TMRB.2021.3072190","volume":"3","author":"K Li","year":"2021","unstructured":"Li, K., Xu, Y. & Meng, M. Q. H. An overview of systems and techniques for autonomous robotic ultrasound acquisitions. IEEE Trans. Med. Robot Bionics. 3, 510\u2013524 (2021).","journal-title":"IEEE Trans. Med. Robot Bionics"},{"key":"31892_CR6","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/j.mri.2003.01.001","volume":"22","author":"TC Noone","year":"2004","unstructured":"Noone, T. C., Semelka, R. C., Chaney, D. M. & Reinhold, C. Abdominal imaging studies: Comparison of diagnostic accuracies resulting from ultrasound, computed tomography, and magnetic resonance imaging. Magn. Reson. Imaging 22, 19\u201324 (2004).","journal-title":"Magn. Reson. Imaging"},{"key":"31892_CR7","doi-asserted-by":"crossref","unstructured":"Mustafa, A. S. B., Alhussein, O., Babiker, M. & Mathkour, H. Development of a robotic system for autonomous liver screening using ultrasound scanning device. In Proc. IEEE Int. Conf. Robot. Biomimetics (ROBIO) 804\u2013809 (2013).","DOI":"10.1109\/ROBIO.2013.6739561"},{"key":"31892_CR8","doi-asserted-by":"crossref","unstructured":"Virga, S., Mahmood, F., Mercaldo, N., Dagnino, R. & Navab, N. Automatic force-compliant robotic ultrasound screening of abdominal aortic aneurysms. In Proc. IEEE\/RSJ Int. Conf. Intell. Robots Syst. (IROS) 508\u2013513 (2016).","DOI":"10.1109\/IROS.2016.7759101"},{"key":"31892_CR9","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1016\/j.sopen.2022.09.002","volume":"10","author":"RB Adams","year":"2022","unstructured":"Adams, R. B. Ultrasound scanning techniques. Surg. Open. Sci. 10, 182\u2013207 (2022).","journal-title":"Surg. Open. Sci."},{"key":"31892_CR10","doi-asserted-by":"crossref","unstructured":"Mustafa, A. S. B. et al. Human abdomen recognition using camera and force sensor in medical robot system for automatic ultrasound scan. In Proc. IEEE Eng. Med. Biol. Soc. 4855\u20134858 (2013).","DOI":"10.1109\/EMBC.2013.6610635"},{"key":"31892_CR11","doi-asserted-by":"publisher","first-page":"40216","DOI":"10.1109\/ACCESS.2022.3165936","volume":"10","author":"M Victorova","year":"2022","unstructured":"Victorova, M., Lee, M. K. S., Navarro-Alarcon, D. & Zheng, Y. Follow the curve: Robotic ultrasound navigation with learning-based localization of spinous processes for scoliosis assessment. IEEE Access. 10, 40216\u201340229 (2022).","journal-title":"IEEE Access."},{"key":"31892_CR12","doi-asserted-by":"publisher","first-page":"5228","DOI":"10.1109\/LRA.2023.3292568","volume":"8","author":"Y Shida","year":"2023","unstructured":"Shida, Y., Kumagai, S., Tsumura, R. & Iwata, H. Automated image acquisition of parasternal long-axis view with robotic echocardiography. IEEE Robot Autom. Lett. 8, 5228\u20135235 (2023).","journal-title":"IEEE Robot Autom. Lett."},{"key":"31892_CR13","doi-asserted-by":"crossref","unstructured":"Ma, X., Zhang, Z. & Zhang, H. K. Autonomous scanning target localization for robotic lung ultrasound imaging. In Proc. IEEE\/RSJ Int. Conf. Intell. Robots Syst. (IROS) 9467\u20139474 (2021).","DOI":"10.1109\/IROS51168.2021.9635902"},{"key":"31892_CR14","doi-asserted-by":"publisher","first-page":"e2461","DOI":"10.1002\/rcs.2461","volume":"19","author":"R Tsumura","year":"2023","unstructured":"Tsumura, R., Koseki, Y., Nitta, N. & Yoshinaka, K. Towards a fully automated robotic platform for remote auscultation. Int. J. Med. Robot Comput. Assist. Surg. 19, e2461 (2023).","journal-title":"Int. J. Med. Robot Comput. Assist. Surg."},{"key":"31892_CR15","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1109\/TUFFC.2022.3211532","volume":"70","author":"J Tan","year":"2023","unstructured":"Tan, J., Wang, W., Yang, J. & Li, X. Fully automatic dual-probe lung ultrasound scanning robot for screening triage. IEEE Trans. Ultrason. Ferroelectr. Freq. Control. 70, 975\u2013988 (2023).","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"31892_CR16","doi-asserted-by":"crossref","unstructured":"Deng, X., Chen, Y., Chen, F. & Li, M. Learning robotic ultrasound scanning skills via human demonstrations and guided explorations. In Proc. IEEE Int. Conf. Robot. Biomimetics (ROBIO) 372\u2013378 (2021).","DOI":"10.1109\/ROBIO54168.2021.9739464"},{"key":"31892_CR17","unstructured":"Bi, Y., Wu, J., Chen, H. & Li, Y. Autonomous path planning for intercostal robotic ultrasound imaging using reinforcement learning. ArXiv Preprint arXiv :240409927 (2024)."},{"key":"31892_CR18","doi-asserted-by":"publisher","first-page":"1173","DOI":"10.1109\/TII.2018.2871864","volume":"15","author":"Q Huang","year":"2019","unstructured":"Huang, Q., Lan, J. & Li, X. Robotic arm based automatic ultrasound scanning for three-dimensional imaging. IEEE Trans. Ind. Inf. 15, 1173\u20131182 (2019).","journal-title":"IEEE Trans. Ind. Inf."},{"key":"31892_CR19","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1007\/s11548-017-1561-1","volume":"12","author":"R Kojcev","year":"2017","unstructured":"Kojcev, R., Khakzar, A., Fuerst, B., Navab, N. & Wein, W. On the reproducibility of expert-operated and robotic ultrasound acquisitions. Int. J. Comput. Assist. Radiol. Surg. 12, 1003\u20131011 (2017).","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"31892_CR20","doi-asserted-by":"publisher","first-page":"12475","DOI":"10.1109\/LRA.2022.3218183","volume":"7","author":"X Ma","year":"2022","unstructured":"Ma, X., Kuo, W. Y., Yang, K., Rahaman, A. & Zhang, H. K. A-SEE: Active-sensing end-effector enabled probe self-normal-positioning for robotic ultrasound imaging applications. IEEE Robot Autom. Lett. 7, 12475\u201312482 (2022).","journal-title":"IEEE Robot Autom. Lett."},{"key":"31892_CR21","doi-asserted-by":"publisher","first-page":"10333","DOI":"10.1109\/TIE.2022.3220864","volume":"70","author":"X Bao","year":"2023","unstructured":"Bao, X., Wang, Y., Li, Z. & Zhang, F. SAPM: Self-adaptive parallel manipulator with pose and force adjustment for robotic ultrasonography. IEEE Trans. Ind. Electron. 70, 10333\u201310343 (2023).","journal-title":"IEEE Trans. Ind. Electron."},{"key":"31892_CR22","doi-asserted-by":"publisher","first-page":"1342","DOI":"10.1109\/LRA.2020.2967682","volume":"5","author":"Z Jiang","year":"2020","unstructured":"Jiang, Z., Huang, Q., Li, X. & Liu, H. Automatic normal positioning of robotic ultrasound probe based only on confidence map optimization and force measurement. IEEE Robot Autom. Lett. 5, 1342\u20131349 (2020).","journal-title":"IEEE Robot Autom. Lett."},{"key":"31892_CR23","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1007\/s11548-023-03019-5","volume":"19","author":"K Okuzaki","year":"2024","unstructured":"Okuzaki, K., Koizumi, N., Yoshinaka, K. & Nishiyama, Y. Rib region detection for scanning path planning for fully automated robotic abdominal ultrasonography. Int. J. Comput. Assist. Radiol. Surg. 19, 449\u2013457 (2024).","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"31892_CR24","doi-asserted-by":"publisher","first-page":"1700","DOI":"10.1109\/LRA.2024.3349959","volume":"9","author":"R Tsumura","year":"2024","unstructured":"Tsumura, R., Koseki, Y., Nitta, N. & Yoshinaka, K. Safe contact force generation for robotic thyroid ultrasound imaging. IEEE Robot Autom. Lett. 9, 1700\u20131707 (2024).","journal-title":"IEEE Robot Autom. Lett."},{"key":"31892_CR25","doi-asserted-by":"publisher","first-page":"645756","DOI":"10.3389\/frobt.2021.645756","volume":"25","author":"L Al-Zogbi","year":"2021","unstructured":"Al-Zogbi, L., Al-Darraji, H., Hussein, A. & Salman, A. Autonomous robotic point-of-care ultrasound imaging for monitoring of COVID-19-induced pulmonary diseases. Front. Robot AI. 25, 645756 (2021).","journal-title":"Front. Robot AI"},{"key":"31892_CR26","doi-asserted-by":"crossref","unstructured":"Mustafa, A. S. B. et al. Human abdomen recognition using camera and force sensor in medical robot system for automatic ultrasound scan. In Proc. IEEE Eng. Med. Biol. Soc., 4855\u20134858 (2013).","DOI":"10.1109\/EMBC.2013.6610635"},{"key":"31892_CR27","unstructured":"Jocher, G. et al. YOLOv5. (2020). https:\/\/github.com\/ultralytics\/yolov5"},{"key":"31892_CR28","unstructured":"Katsuragi, A., Nakamura, Y., Takahashi, S. & Saito, K. Detection of organs and classification of missing parts using deep learning for automated ultrasound diagnosis. In Proc. 34th Annu. Meeting Jpn. Soc. Ultrasound Med. Kanto Koshinetsu Region 107 (2022)."},{"key":"31892_CR29","unstructured":"Jocher, G. et al. YOLOv8. (2023). https:\/\/github.com\/ultralytics\/ultralytics"},{"key":"31892_CR30","doi-asserted-by":"publisher","first-page":"1048","DOI":"10.1080\/00365520903075188","volume":"44","author":"B Ehrenstein","year":"2009","unstructured":"Ehrenstein, B., Froh, S., Schlottmann, K., Sch\u00f6lmerich, J. & Schacherer, D. Effect of fasting prior to abdominal sonography examinations on the quality of imaging under routine conditions: A randomized, examiner-blinded trial. Scand. J. Gastroenterol. 44, 1048\u20131054 (2009).","journal-title":"Scand. J. Gastroenterol."},{"key":"31892_CR31","doi-asserted-by":"crossref","unstructured":"Weill, F. S. The bile ducts: Examination techniques and sonoanatomy. Ultrasound Diagnosis Dig. Diseases (1990).","DOI":"10.1007\/978-3-642-97095-5"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-31892-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-31892-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-31892-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T15:54:15Z","timestamp":1781625255000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-31892-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,10]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["31892"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-31892-4","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,10]]},"assertion":[{"value":"11 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Approval of all ethical and protocols was granted by the institutional review board at National Institute of Advanced Industrial Science and Technology under Application No. 2024\u2009\u2212\u20090563.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}],"article-number":"2084"}}