{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:34:13Z","timestamp":1790814853517,"version":"4.1.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T00:00:00Z","timestamp":1766016000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T00:00:00Z","timestamp":1768953600000},"content-version":"vor","delay-in-days":34,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["5R01EY033847"],"award-info":[{"award-number":["5R01EY033847"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100001818","name":"Research to Prevent Blindness","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100001818","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100023741","name":"University of California-San Diego","doi-asserted-by":"publisher","award":["P30EY022589"],"award-info":[{"award-number":["P30EY022589"]}],"id":[{"id":"10.13039\/100023741","id-type":"DOI","asserted-by":"publisher"}]},{"name":"UCSD Jacobs Retina Center"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The purpose of the study was to compare Optical Coherence Tomography Angiography (OCTA) scan speeds of 85\u00a0kHz and 125\u00a0kHz with respect to image quality, diagnostic reliability, and scan time in patients with retinal diseases. In this prospective cohort study, OCTA images were obtained at both scan speeds in 70 eyes from 40 patients with retinal diseases. Masked expert graders evaluated qualitative parameters including clinical utility, artifacts, and overall image quality. Quantitative parameters including scan time, Heidelberg Q-score, and OCTA-Q score were recorded. In 46 eyes with visible choroidal neovascular membrane in the avascular layer of OCTA, AngioTool (Image J) was used to assess vessel percentage area, vessel junction density, average vessel length, and E-Lacunarity. Acquisition speed of 125\u00a0kHz OCTA was significantly faster than that of 85\u00a0kHz. There were no statistically significant differences in AngioTool parameters between the two protocols. 125\u00a0kHz was significantly better than 85\u00a0kHz for image quality with fewer noise artefacts and vessel projection artefacts. In conclusion, 125\u00a0kHz SHIFT OCTA offers comparable to better image quality to the 85\u00a0kHz OCTA with significantly faster acquisition, potentially improving clinical workflow without compromising diagnostic reliability.<\/jats:p>","DOI":"10.1038\/s41598-025-32549-y","type":"journal-article","created":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T23:04:55Z","timestamp":1766099095000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Impact of 85\u00a0kHz versus 125\u00a0kHz SHIFT OCTA scan speeds on image quality in retinal diseases and diagnostic reliability of choroidal neovascular membranes"],"prefix":"10.1038","volume":"16","author":[{"given":"Melanie D.","family":"Tran","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nehal Nailesh","family":"Mehta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ines D.","family":"Nagel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed S.","family":"Morsy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amr L.","family":"Ali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Heinke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruby","family":"Munoz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dirk-Uwe","family":"Bartsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Evan","family":"Walker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingyun","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William R.","family":"Freeman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,18]]},"reference":[{"issue":"6","key":"32549_CR1","doi-asserted-by":"publisher","first-page":"496","DOI":"10.3928\/23258160-20141118-03","volume":"45","author":"E Moult","year":"2014","unstructured":"Moult, E. et al. Ultrahigh-speed swept-source OCT angiography in exudative AMD. Ophthalmic Surg. Lasers Imaging Retina. 45(6), 496\u2013505. https:\/\/doi.org\/10.3928\/23258160-20141118-03 (2014).","journal-title":"Ophthalmic Surg. Lasers Imaging Retina"},{"key":"32549_CR2","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1159\/000442784","volume":"56","author":"NK Waheed","year":"2016","unstructured":"Waheed, N. K., Moult, E. M., Fujimoto, J. G. & Rosenfeld, P. J. Optical coherence tomography angiography of dry Age-Related macular degeneration. Dev. Ophthalmol. 56, 91\u2013100. https:\/\/doi.org\/10.1159\/000442784 (2016).","journal-title":"Dev. Ophthalmol."},{"issue":"1","key":"32549_CR3","doi-asserted-by":"publisher","first-page":"84","DOI":"10.4103\/2008-322X.180709","volume":"11","author":"KV Chalam","year":"2016","unstructured":"Chalam, K. V. & Sambhav, K. Optical coherence tomography angiography in retinal diseases. J. Ophthalmic Vis. Res. 11(1), 84\u201392. https:\/\/doi.org\/10.4103\/2008-322X.180709 (2016).","journal-title":"J. Ophthalmic Vis. Res."},{"issue":"10","key":"32549_CR4","doi-asserted-by":"publisher","first-page":"1653","DOI":"10.1097\/IAE.0000000000003867","volume":"01","author":"R Dolz-Marco","year":"2023","unstructured":"Dolz-Marco, R. et al. A qualitative and quantitative analysis. Retina Oct. 01(10), 1653\u20131661. https:\/\/doi.org\/10.1097\/IAE.0000000000003867 (2023).","journal-title":"Retina Oct."},{"issue":"1","key":"32549_CR5","doi-asserted-by":"publisher","first-page":"28997","DOI":"10.1038\/s41598-024-80562-4","volume":"22","author":"L Vidal-Oliver","year":"2024","unstructured":"Vidal-Oliver, L., Herzig-de Almeida, E., Spissinger, S., Dolz-Marco, R. & Finger, R. P. Scan speed affects quantitative optical coherence tomography angiography vascular metrics. Sci Rep Nov. 22(1), 28997. https:\/\/doi.org\/10.1038\/s41598-024-80562-4 (2024).","journal-title":"Sci Rep Nov"},{"issue":"1","key":"32549_CR6","doi-asserted-by":"publisher","first-page":"13990","DOI":"10.1038\/s41598-024-61551-z","volume":"18","author":"DN Deussen","year":"2024","unstructured":"Deussen, D. N. et al. Effect of manual OCTA segmentation correction to improve image quality and visibility of choroidal neovascularization in AMD. Sci Rep Jun. 18(1), 13990. https:\/\/doi.org\/10.1038\/s41598-024-61551-z (2024).","journal-title":"Sci Rep Jun"},{"issue":"1","key":"32549_CR7","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1038\/s41433-021-01879-2","volume":"37","author":"M Choi","year":"2023","unstructured":"Choi, M., Kim, S. W., Yun, C., Oh, J. H. & Oh, J. Predictive role of optical coherence tomography angiography for exudation recurrence in patients with type 1 neovascular age-related macular degeneration treated with pro-re-nata protocol. Eye (Lond) Jan. 37(1), 34\u201341. https:\/\/doi.org\/10.1038\/s41433-021-01879-2 (2023).","journal-title":"Eye (Lond) Jan"},{"issue":"2","key":"32549_CR8","doi-asserted-by":"publisher","first-page":"271","DOI":"10.18502\/jovr.v16i2.9091","volume":"16","author":"P Anvari","year":"2021","unstructured":"Anvari, P., Ashrafkhorasani, M., Habibi, A. & Falavarjani, K. G. Artifacts in optical coherence tomography angiography. J. Ophthalmic Vis. Res. 16(2), 271\u2013286. https:\/\/doi.org\/10.18502\/jovr.v16i2.9091 (2021).","journal-title":"J. Ophthalmic Vis. Res."},{"issue":"1","key":"32549_CR9","doi-asserted-by":"publisher","first-page":"12897","DOI":"10.1038\/s41598-018-31321-9","volume":"27","author":"HB Lim","year":"2018","unstructured":"Lim, H. B., Kim, Y. W., Kim, J. M., Jo, Y. J. & Kim, J. Y. The importance of signal strength in quantitative assessment of retinal vessel density using optical coherence tomography angiography. Sci Rep Aug. 27(1), 12897. https:\/\/doi.org\/10.1038\/s41598-018-31321-9 (2018).","journal-title":"Sci Rep Aug"},{"issue":"10","key":"32549_CR10","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1080\/02713683.2023.2232957","volume":"48","author":"JP Bodenbender","year":"2023","unstructured":"Bodenbender, J. P., Kowalski, M., Stingl, K., Ziemssen, F. & K\u00fchlewein, L. Impact of A-Scan rate on image quality and acquisition time in OCT. Curr Eye Res Oct. 48(10), 973\u2013979. https:\/\/doi.org\/10.1080\/02713683.2023.2232957 (2023).","journal-title":"Curr Eye Res Oct."},{"issue":"1","key":"32549_CR11","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1186\/s40942-025-00691-4","volume":"17","author":"A Heinke","year":"2025","unstructured":"Heinke, A. et al. Faricimab for treatment-resistant choroidal neovascularization (CNV) in neovascular age-related macular degeneration (nAMD): seven-months results using artificial intelligence and OCTA. Int J. Retina Vitreous Jun. 17(1), 68. https:\/\/doi.org\/10.1186\/s40942-025-00691-4 (2025).","journal-title":"Int J. Retina Vitreous Jun"},{"key":"32549_CR12","unstructured":"Engineering, H. 125\u00a0kHz Scan Speed. Heidelberg Engineering. Accessed July 5, 2025. (2025). https:\/\/www.heidelbergengineering.com\/int\/125-khz-scan-speed\/"},{"issue":"11","key":"32549_CR13","doi-asserted-by":"publisher","first-page":"5755","DOI":"10.1364\/BOE.10.005755","volume":"01","author":"B Baumann","year":"2019","unstructured":"Baumann, B. et al. Signal averaging improves signal-to-noise in OCT images: but which approach works best, and when? Biomed Opt. Express Nov. 01(11), 5755\u20135775. https:\/\/doi.org\/10.1364\/BOE.10.005755 (2019).","journal-title":"Biomed Opt. Express Nov"},{"key":"32549_CR14","doi-asserted-by":"publisher","unstructured":"Hogg, R. E. et al. Quantitative parameters from OCT angiography in patients with diabetic retinopathy and in those with only peripheral retinopathy compared with control participants. Ophthalmol. Sci. 1(2). https:\/\/doi.org\/10.1016\/j.xops.2021.100030 (2021).","DOI":"10.1016\/j.xops.2021.100030"},{"issue":"7","key":"32549_CR15","doi-asserted-by":"publisher","first-page":"2637","DOI":"10.3390\/jcm12072637","volume":"12","author":"M Lupidi","year":"2023","unstructured":"Lupidi, M. et al. Quantitative and qualitative assessments of retinal structure with variable A-Scan rate spectralis OCT: insights into IPL multilaminarity. J. Clin. Med. 12(7), 2637 (2023).","journal-title":"J. Clin. Med."},{"issue":"1","key":"32549_CR16","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1364\/BOE.10.000050","volume":"01","author":"JV Migacz","year":"2019","unstructured":"Migacz, J. V. et al. Megahertz-rate optical coherence tomography angiography improves the contrast of the choriocapillaris and choroid in human retinal imaging. Biomed Opt. Express Jan. 01(1), 50\u201365. https:\/\/doi.org\/10.1364\/BOE.10.000050 (2019).","journal-title":"Biomed Opt. Express Jan"},{"issue":"2","key":"32549_CR17","doi-asserted-by":"publisher","first-page":"e0318733","DOI":"10.1371\/journal.pone.0318733","volume":"20","author":"NN Mehta","year":"2025","unstructured":"Mehta, N. N. et al. Dry eye disease treatment improves subjective quality-of-life responses in patients with AMD, independent of disease stage. PLoS One. 20(2), e0318733. https:\/\/doi.org\/10.1371\/journal.pone.0318733 (2025).","journal-title":"PLoS One"},{"issue":"6","key":"32549_CR18","doi-asserted-by":"publisher","first-page":"985","DOI":"10.1016\/j.ophtha.2006.02.018","volume":"113","author":"DM Stein","year":"2006","unstructured":"Stein, D. M. et al. Effect of corneal drying on optical coherence tomography. Ophthalmology 113(6), 985\u2013991. https:\/\/doi.org\/10.1016\/j.ophtha.2006.02.018 (2006).","journal-title":"Ophthalmology"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-32549-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-32549-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-32549-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T00:14:02Z","timestamp":1769213642000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-32549-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,18]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["32549"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-32549-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,18]]},"assertion":[{"value":"6 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"2735"}}