{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T08:03:10Z","timestamp":1791964990514,"version":"4.3.4"},"reference-count":52,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,20]],"date-time":"2025-12-20T00:00:00Z","timestamp":1766188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T00:00:00Z","timestamp":1769126400000},"content-version":"vor","delay-in-days":34,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["UG3EB034686"],"award-info":[{"award-number":["UG3EB034686"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Gamma\u2013positron imaging with tracers that emit a prompt\n                    <jats:inline-formula>\n                      <jats:tex-math>$$\\gamma$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    (&gt; 511 keV) is vulnerable to Compton down-scatter leaking into the 511-keV window and mimicking true annihilation pairs. Conventional Positron Emission Tomography (PET) systems reconstruct annihilation events without leveraging that the two 511-keV photons are not only orthogonally polarized but also produced in a Bell-entangled state. The polarization correlations of this entanglement imprint themselves in Compton scattering kinematics, particularly the relative azimuthal scattering angle (\n                    <jats:inline-formula>\n                      <jats:tex-math>$$\\Delta \\phi$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    ), offering a physics-informed handle for event discrimination. We present a machine-learning framework that exploits these quantum-encoded features to resolve true lines of response (LORs) and reject random coincidences in a dual-panel cadmium zinc telluride (CZT) system. Detected events were categorized into one-photoelectric (1P) and Compton (1C) interaction patterns, yielding four candidate interaction sequences per event. Each event was represented as a 4\n                    <jats:inline-formula>\n                      <jats:tex-math>$$\\times$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    21 feature matrix comprising spatial coordinates, energy deposits, and angular descriptors, including\n                    <jats:inline-formula>\n                      <jats:tex-math>$$\\Delta \\phi$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    and polar scattering angle\n                    <jats:inline-formula>\n                      <jats:tex-math>$$\\theta$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    . Feature ablation with five-fold cross-validation revealed that the combination of energy and\n                    <jats:inline-formula>\n                      <jats:tex-math>$$\\Delta \\phi$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    provided the highest discriminative power (Area Under the Receiver Operating Characteristic Curve (ROC\u2013AUC) 0.87\u20130.95), followed by energy alone (ROC\u2013AUC 0.85\u20130.95), while inclusion of spatial coordinates with energy and\n                    <jats:inline-formula>\n                      <jats:tex-math>$$\\Delta \\phi$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    ranked third, achieving consistent performance across folds (ROC\u2013AUC 0.81\u20130.91). These results demonstrate that incorporating entanglement-sensitive angular features into learning pipelines can suppress prompt contamination while preserving true LORs in a gamma-positron imaging system.\n                  <\/jats:p>","DOI":"10.1038\/s41598-025-32951-6","type":"journal-article","created":{"date-parts":[[2025,12,20]],"date-time":"2025-12-20T10:52:32Z","timestamp":1766227952000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Machine learning-assisted event classification in cadmium zinc telluride positron emission tomography detectors leveraging entanglement-informed angular correlations"],"prefix":"10.1038","volume":"16","author":[{"given":"Praveen Gurunath","family":"Bharathi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory","family":"Romanchek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Greyson","family":"Shoop","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"King","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"Kupinski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lars","family":"Furenlid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shiva","family":"Abbaszadeh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,20]]},"reference":[{"issue":"18","key":"32951_CR1","doi-asserted-by":"publisher","first-page":"4551","DOI":"10.7150\/thno.19782","volume":"7","author":"T Li","year":"2017","unstructured":"Li, T. et al. Quantitative imaging for targeted radionuclide therapy dosimetry-technical review. Theranostics. 7(18), 4551\u20134565 (2017).","journal-title":"Theranostics."},{"key":"32951_CR2","doi-asserted-by":"publisher","DOI":"10.1016\/j.apradiso.2021.109599","volume":"170","author":"F Rosar","year":"2021","unstructured":"Rosar, F. et al. Impact of prompt gamma emission of $$^{44}$$Sc on quantification in preclinical and clinical PET systems. Appl. Radiation Isotopes. 170, 109599 (2021).","journal-title":"Appl. Radiation Isotopes."},{"key":"32951_CR3","doi-asserted-by":"crossref","unstructured":"Hong, I., Nekolla, S. G. & Michel, C. Improving Scatter Correction for Ga-68 PSMA PET Studies. 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS\/MIC). 1-2 (2017).","DOI":"10.1109\/NSSMIC.2017.8532999"},{"issue":"4","key":"32951_CR4","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1109\/42.476109","volume":"14","author":"CC Martin","year":"1995","unstructured":"Martin, C. C., Christian, B. T., Satter, M. R., Nickerson, L. D. & Nickles, R. J. Quantitative PET with positron emitters that emit prompt gamma rays. IEEE Trans. Med. Imaging. 14(4), 681\u2013687 (1995).","journal-title":"IEEE Trans. Med. Imaging."},{"issue":"Suppl 1","key":"32951_CR5","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1007\/s00259-011-1768-2","volume":"38","author":"M Lubberink","year":"2011","unstructured":"Lubberink, M. & Herzog, H. Quantitative imaging of $$^{124}I$$ and $$^{86}Y$$ with PET. Eur. J. Nucl. Med. Mol. Imaging. 38(Suppl 1), 10\u201318 (2011).","journal-title":"Eur. J. Nucl. Med. Mol. Imaging."},{"issue":"9","key":"32951_CR6","doi-asserted-by":"publisher","first-page":"3479","DOI":"10.1088\/0031-9155\/60\/9\/3479","volume":"60","author":"PEN Braad","year":"2015","unstructured":"Braad, P. E. N., Hansen, S. B., Thisgaard, H. & H\u00f8ilund-Carlsen, P. F. PET imaging with the non-pure positron emitters: $$^{55}Co$$, $$^{86}Y$$ and $$^{124}I$$. Phys. Med. Biol. 60(9), 3479 (2015).","journal-title":"Phys. Med. Biol."},{"issue":"3","key":"32951_CR7","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1088\/0031-9155\/44\/3\/019","volume":"44","author":"CS Levin","year":"1999","unstructured":"Levin, C. S. & Hoffman, E. J. Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution. Phys. Med. Biol. 44(3), 781 (1999).","journal-title":"Phys. Med. Biol."},{"issue":"5","key":"32951_CR8","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1109\/TNS.2005.858264","volume":"52","author":"MR Palmer","year":"2005","unstructured":"Palmer, M. R., Zhu, X. & Parker, J. A. Modeling and simulation of positron range effects for high resolution PET imaging. IEEE Trans. Nucl. Sci. 52(5), 1391\u20131395 (2005).","journal-title":"IEEE Trans. Nucl. Sci."},{"issue":"23","key":"32951_CR9","doi-asserted-by":"publisher","first-page":"7419","DOI":"10.1088\/0031-9155\/59\/23\/7419","volume":"59","author":"L J\u00f8dal","year":"2014","unstructured":"J\u00f8dal, L., Le Loirec, C. & Champion, C. Positron range in PET imaging: Non-conventional isotopes. Phys. Med. Biol. 59(23), 7419 (2014).","journal-title":"Phys. Med. Biol."},{"issue":"14","key":"32951_CR10","doi-asserted-by":"publisher","first-page":"4539","DOI":"10.1088\/0031-9155\/56\/14\/020","volume":"56","author":"A Andreyev","year":"2011","unstructured":"Andreyev, A. & Celler, A. Dual-isotope PET using positron-gamma emitters. Phys. Med. Biol. 56(14), 4539 (2011).","journal-title":"Phys. Med. Biol."},{"issue":"6","key":"32951_CR11","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abe5fc","volume":"66","author":"FJ Beekman","year":"2021","unstructured":"Beekman, F. J., Kamphuis, C., Koustoulidou, S., Ramakers, R. M. & Goorden, M. Positron range-free and multi-isotope tomography of positron emitters. Phys. Med. Biol. 66(6), 065011 (2021).","journal-title":"Phys. Med. Biol."},{"key":"32951_CR12","doi-asserted-by":"crossref","unstructured":"Gonz\u00e1lez, E., Olcott, P. D., Bieniosek, M. & Levin, C. S. Methods for increasing the sensitivity of simultaneous multi-isotope positron emission tomography 2011 IEEE Nuclear Science Symposium Conference Record. 3597-3601 (2011)","DOI":"10.1109\/NSSMIC.2011.6153676"},{"issue":"01","key":"32951_CR13","doi-asserted-by":"publisher","first-page":"P01035","DOI":"10.1088\/1748-0221\/16\/01\/P01035","volume":"16","author":"T Fukuchi","year":"2021","unstructured":"Fukuchi, T. et al. Image reconstruction method for dual-isotope positron emission tomography. J. Instrument. 16(01), P01035 (2021).","journal-title":"J. Instrument."},{"issue":"2","key":"32951_CR14","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ada5a7","volume":"70","author":"S Takyu","year":"2025","unstructured":"Takyu, S. et al. A whole gamma imaging prototype for higher quantitative imaging of $$^{89}Zr$$-labeled antibodies in a tumor mouse model. Phys. Med. Biol. 70(2), 025012 (2025).","journal-title":"Phys. Med. Biol."},{"issue":"6","key":"32951_CR15","doi-asserted-by":"publisher","first-page":"826","DOI":"10.1109\/TRPMS.2020.3046409","volume":"5","author":"D Giovagnoli","year":"2020","unstructured":"Giovagnoli, D. et al. A pseudo-TOF image reconstruction approach for three-gamma small animal imaging. IEEE Trans. Radiat. Plasma Med. Sci. 5(6), 826\u2013834 (2020).","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"32951_CR16","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1016\/j.nima.2017.12.022","volume":"912","author":"LG Manzano","year":"2018","unstructured":"Manzano, L. G. et al. XEMIS2: A liquid xenon detector for small animal medical imaging. Nucl. Instrum. Methods Phys. Res. Sect. A Accelerators Spectrometers Detectors Associated Equipment. 912, 329\u2013332 (2018).","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accelerators Spectrometers Detectors Associated Equipment."},{"issue":"2","key":"32951_CR17","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa9a2b","volume":"63","author":"S Abbaszadeh","year":"2018","unstructured":"Abbaszadeh, S., Chinn, G. & Levin, C. S. Positioning true coincidences that undergo inter-and intra-crystal scatter for a sub-mm resolution cadmium zinc telluride-based PET system. Phys. Med. Biol. 63(2), 025012 (2018).","journal-title":"Phys. Med. Biol."},{"key":"32951_CR18","doi-asserted-by":"crossref","unstructured":"Du, Y. F., He, Z., Knoll, G. F., Wehe, D. K. & Li, W. Evaluation of a Compton scattering camera using 3-D position sensitive CdZnTe detectors. Nucl. Instrum. Methods Phys. Res. Sect. A Accelerators Spectrometers Detectors Associated Equipment. 457, 203\u2013211 (2001).","DOI":"10.1016\/S0168-9002(00)00669-0"},{"key":"32951_CR19","doi-asserted-by":"crossref","unstructured":"Chinn, G., Foudray, Angela M. K. & Levin, C. S. A Method to Include Single Photon Events in Image Reconstruction for a 1 mm Resolution PET System Built with Advanced 3-D Positioning Detectors. 2006 IEEE Nuclear Science Symposium Conference Record. 3, 1740-1745 (2006).","DOI":"10.1109\/NSSMIC.2006.354233"},{"issue":"5","key":"32951_CR20","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aafe20","volume":"64","author":"P Moskal","year":"2019","unstructured":"Moskal, P. et al. Feasibility study of the positronium imaging with the J-PET tomograph. Phys. Med. Biol. 64(5), 055017 (2019).","journal-title":"Phys. Med. Biol."},{"issue":"10","key":"32951_CR21","doi-asserted-by":"publisher","DOI":"10.35848\/1882-0786\/ac8d7b","volume":"15","author":"S Takyu","year":"2022","unstructured":"Takyu, S. et al. Two-dimensional positronium lifetime imaging using certified reference materials. Appl. Phys. Express. 15(10), 106001 (2022).","journal-title":"Appl. Phys. Express."},{"issue":"9","key":"32951_CR22","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1038\/s42254-019-0078-7","volume":"1","author":"P Moskal","year":"2019","unstructured":"Moskal, P., Jasi\u0144ska, B., St\u0119pie\u0144, E. \u0141 & Bass, S. D. Positronium in medicine and biology. Nat. Rev. Phys. 1(9), 527\u2013529 (2019).","journal-title":"Nat. Rev. Phys."},{"issue":"1","key":"32951_CR23","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1038\/s42005-020-00440-z","volume":"3","author":"K Shibuya","year":"2020","unstructured":"Shibuya, K., Saito, H., Nishikido, F., Takahashi, M. & Yamaya, T. Oxygen sensing ability of positronium atom for tumor hypoxia imaging. Commun. Phys. 3(1), 173 (2020).","journal-title":"Commun. Phys."},{"key":"32951_CR24","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1103\/Physics.17.138","volume":"17","author":"P Moskal","year":"2024","unstructured":"Moskal, P. Positron emission tomography could be aided by entanglement. Physics. 17, 138 (2024).","journal-title":"Physics."},{"issue":"10","key":"32951_CR25","doi-asserted-by":"publisher","DOI":"10.1088\/2399-6528\/ab45db","volume":"3","author":"P Caradonna","year":"2019","unstructured":"Caradonna, P., Reutens, D., Takahashi, T., Takeda, S. I. & Vegh, V. Probing entanglement in Compton interactions. J. Phys. Commun. 3(10), 105005 (2019).","journal-title":"J. Phys. Commun."},{"issue":"1","key":"32951_CR26","doi-asserted-by":"publisher","first-page":"2646","DOI":"10.1038\/s41467-021-22907-5","volume":"12","author":"DP Watts","year":"2021","unstructured":"Watts, D. P. et al. Photon quantum entanglement in the MeV regime and its application in PET imaging. Nat. Commun. 12(1), 2646 (2021).","journal-title":"Nat. Commun."},{"issue":"03","key":"32951_CR27","doi-asserted-by":"publisher","first-page":"P03010","DOI":"10.1088\/1748-0221\/17\/03\/P03010","volume":"17","author":"D Abdurashitov","year":"2022","unstructured":"Abdurashitov, D. et al. Setup of Compton polarimeters for measuring entangled annihilation photons. J. Instrument. 17(03), P03010 (2022).","journal-title":"J. Instrument."},{"issue":"5","key":"32951_CR28","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1134\/S1547477122050405","volume":"19","author":"A Strizhak","year":"2022","unstructured":"Strizhak, A., Abdurashitov, D., Baranov, A., Ivashkin, A. & Musin, S. Study of the Compton scattering of entangled annihilation photons. Phys. Particles Nuclei Lett. 19(5), 509\u2013512 (2022).","journal-title":"Phys. Particles Nuclei Lett."},{"issue":"1","key":"32951_CR29","doi-asserted-by":"publisher","first-page":"7559","DOI":"10.1038\/s41598-023-34767-8","volume":"13","author":"A Ivashkin","year":"2023","unstructured":"Ivashkin, A. et al. Testing entanglement of annihilation photons. Sci. Rep. 13(1), 7559 (2023).","journal-title":"Sci. Rep."},{"key":"32951_CR30","doi-asserted-by":"crossref","unstructured":"Kumar, D., Sharma, S. & Moskal, P. Experimental observation of polarization correlation of entangled photons from positronium atom using J-PET detector. The European Physical Society Conference on High Energy Physics. 564 (2023).","DOI":"10.22323\/1.449.0564"},{"issue":"1","key":"32951_CR31","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.cpet.2023.08.003","volume":"19","author":"T Yamaya","year":"2024","unstructured":"Yamaya, T., Tashima, H., Takyu, S. & Takahashi, M. Whole gamma imaging: Challenges and opportunities. PET Clin. 19(1), 83\u201393 (2024).","journal-title":"PET Clin."},{"issue":"supplement 2","key":"32951_CR32","volume":"65","author":"G Akamatsu","year":"2024","unstructured":"Akamatsu, G. et al. Zr-89 mouse Compton imaging with the developed next-generation whole gamma imaging system. J. Nucl. Med. 65(supplement 2), 241604 (2024).","journal-title":"J. Nucl. Med."},{"issue":"12","key":"32951_CR33","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab8e89","volume":"65","author":"E Yoshida","year":"2020","unstructured":"Yoshida, E. et al. Whole gamma imaging: A new concept of PET combined with Compton imaging. Phys. Med. Biol. 65(12), 125013 (2020).","journal-title":"Phys. Med. Biol."},{"issue":"4","key":"32951_CR34","doi-asserted-by":"publisher","first-page":"1618","DOI":"10.1109\/TNS.2004.832573","volume":"51","author":"CE Lehner","year":"2004","unstructured":"Lehner, C. E., He, Z. & Zhang, F. 4$$\\pi$$ Compton imaging using a 3-D position-sensitive CdZnTe detector via weighted list-mode maximum likelihood. IEEE Trans. Nucl. Sci. 51(4), 1618\u20131624 (2004).","journal-title":"IEEE Trans. Nucl. Sci."},{"issue":"16","key":"32951_CR35","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad682e","volume":"69","author":"FE Enr\u00edquez-Mier-y-Ter\u00e1n","year":"2024","unstructured":"Enr\u00edquez-Mier-y-Ter\u00e1n, F. E., Zhou, L., Meikle, S. R. & Kyme, A. Z. A deep neural network for positioning and inter-crystal scatter identification in multiplexed PET detectors: A simulation study. Phys. Med. Biol. 69(16), 165017 (2024).","journal-title":"Phys. Med. Biol."},{"issue":"9","key":"32951_CR36","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/accacb","volume":"68","author":"S Lee","year":"2023","unstructured":"Lee, S. & Lee, J. S. Experimental evaluation of convolutional neural network-based inter-crystal scattering recovery for high-resolution PET detectors. Phys. Med. Biol. 68(9), 095017 (2023).","journal-title":"Phys. Med. Biol."},{"issue":"14","key":"32951_CR37","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ace1d1","volume":"68","author":"J Zou","year":"2023","unstructured":"Zou, J., Ye, J., Yu, J. & Cui, K. A simulation study of 1D U-Net-based inter-crystal scatter event recovery of PET detectors. Phys. Med. Biol. 68(14), 145012 (2023).","journal-title":"Phys. Med. Biol."},{"issue":"11","key":"32951_CR38","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/addbbe","volume":"70","author":"SM Kinyanjui","year":"2025","unstructured":"Kinyanjui, S. M., Kuang, Z., Liu, Z., Ren, N. & Yang, Y. Machine learning positioning algorithms for long semi-monolithic scintillator PET detectors. Phys. Med. Biol. 70(11), 115018 (2025).","journal-title":"Phys. Med. Biol."},{"key":"32951_CR39","doi-asserted-by":"crossref","unstructured":"Sarrut, D. et al. Advanced Monte Carlo simulations of emission tomography imaging systems with GATE. Phys. Med. Biol. 66 (10), 10TR03 (2021).","DOI":"10.1088\/1361-6560\/abf276"},{"issue":"3","key":"32951_CR40","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/S0168-9002(03)01368-8","volume":"506","author":"S Agostinelli","year":"2003","unstructured":"Agostinelli, S. et al. Geant4-a simulation toolkit. Nucl. Instrum. Methods Phys. Res. Sect. A Accelerators Spectrometers Detectors Associated Equipment. 506(3), 250\u2013303 (2003).","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. A Accelerators Spectrometers Detectors Associated Equipment."},{"key":"32951_CR41","doi-asserted-by":"publisher","first-page":"27","DOI":"10.5604\/01.3001.0054.9079","volume":"20","author":"GR Romanchek","year":"2024","unstructured":"Romanchek, G. R. et al. Investigation of quantum entanglement information for $$\\beta ^{+} \\gamma$$ coincidences. Bio-Algorithms Med-Syst. 20, 27\u201334 (2024).","journal-title":"Bio-Algorithms Med-Syst."},{"issue":"2","key":"32951_CR42","doi-asserted-by":"publisher","first-page":"334","DOI":"10.1103\/PhysRev.79.334","volume":"79","author":"DL Falkoff","year":"1950","unstructured":"Falkoff, D. L. & Uhlenbeck, G. E. On the beta-gamma-angular correlation. Phys. Rev. 79(2), 334\u2013340 (1950).","journal-title":"Phys. Rev."},{"issue":"3","key":"32951_CR43","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1103\/RevModPhys.25.729","volume":"25","author":"LC Biedenharn","year":"1953","unstructured":"Biedenharn, L. C. & Rose, M. E. Theory of angular correlation of nuclear radiations. Rev. Modern Phys. 25(3), 729\u2013777 (1953).","journal-title":"Rev. Modern Phys."},{"issue":"6","key":"32951_CR44","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1109\/TRPMS.2023.3256406","volume":"7","author":"E Enlow","year":"2023","unstructured":"Enlow, E., Diba, M., Clayton, J., Harris, B. & Abbaszadeh, S. Impact of flexible circuit bonding and system integration on energy resolution of cross-strip CZT detectors. IEEE Trans. Radiation Plasma Med. Sci. 7(6), 580\u2013586 (2023).","journal-title":"IEEE Trans. Radiation Plasma Med. Sci."},{"issue":"8","key":"32951_CR45","doi-asserted-by":"publisher","first-page":"886","DOI":"10.1109\/TRPMS.2024.3411522","volume":"8","author":"E Enlow","year":"2024","unstructured":"Enlow, E., Wang, Y., Shoop, G. & Abbaszadeh, S. Performance investigations of two channel readout configurations on the cross-strip cadmium zinc telluride detector. IEEE Trans. Radiation Plasma Med. Sci. 8(8), 886\u2013892 (2024).","journal-title":"IEEE Trans. Radiation Plasma Med. Sci."},{"issue":"5","key":"32951_CR46","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1109\/TRPMS.2021.3111547","volume":"6","author":"Y Wang","year":"2021","unstructured":"Wang, Y., Herbst, R. & Abbaszadeh, S. Development and characterization of modular readout design for two-panel head-and-neck dedicated PET system based on CZT detectors. IEEE Trans. Radiation Plasma Med. Sci. 6(5), 517\u2013521 (2021).","journal-title":"IEEE Trans. Radiation Plasma Med. Sci."},{"issue":"4","key":"32951_CR47","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1109\/TRPMS.2020.2964293","volume":"4","author":"M Li","year":"2020","unstructured":"Li, M., Yockey, B. & Abbaszadeh, S. Design study of a dedicated head and neck cancer PET system. IEEE Trans. Radiation Plasma Med. Sci. 4(4), 489\u2013497 (2020).","journal-title":"IEEE Trans. Radiation Plasma Med. Sci."},{"key":"32951_CR48","unstructured":"Kinga, D. & Adam, J. B. A method for stochastic optimization. arXiv preprint. 1412 (6), 1412.6980 (2014)."},{"key":"32951_CR49","unstructured":"Paszke, A. et al. Pytorch: An imperative style, high-performance deep learning library. Adv. Neural Inform. Process. Syst. 32, (2019)."},{"key":"32951_CR50","unstructured":"Lundberg, S. M. & Lee, S. I. A unified approach to interpreting model predictions. Adv. Neural Inform. Process. Syst. 30 (2017)."},{"key":"32951_CR51","doi-asserted-by":"crossref","unstructured":"Nasiri, N. & Abbaszadeh, S. A deep learning approach to correctly identify the sequence of coincidences in cross-strip CZT detectors. In Medical Imaging 2021: Physics of Medical Imaging. 11595, 1011-1018 (2021).","DOI":"10.1117\/12.2582063"},{"issue":"8","key":"32951_CR52","doi-asserted-by":"publisher","first-page":"916","DOI":"10.1109\/TRPMS.2024.3388872","volume":"8","author":"G Romanchek","year":"2024","unstructured":"Romanchek, G., Shoop, G., Gholami, K., Enlow, E. & Abbaszadeh, S. Quantum Entanglement Filtering: A PET feasibility study in imaging dual-positron and prompt gamma emission via Monte Carlo simulation. IEEE Trans. Radiation Plasma Med. Sci. 8(8), 916\u2013925 (2024).","journal-title":"IEEE Trans. Radiation Plasma Med. Sci."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-32951-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-32951-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-32951-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T02:07:17Z","timestamp":1769220437000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-32951-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,20]]},"references-count":52,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["32951"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-32951-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,20]]},"assertion":[{"value":"16 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"3116"}}