{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T04:38:58Z","timestamp":1793335138377,"version":"4.5.0"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T00:00:00Z","timestamp":1768176000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T00:00:00Z","timestamp":1768176000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["25K19181"],"award-info":[{"award-number":["25K19181"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Ultrasonography-based diagnosis is increasingly used owing to its reliability. However, the conventional ultrasound gel has limitations of patient discomfort and cost. This study evaluated the clinical utility of a newly developed gel pad for ultrasound diagnosis composed of tamarind seed gum (0.1\u20135.0 wt%), polyhydric alcohol (25.0\u201370.0 wt%), and water (30.0\u201370.0 wt%). Ultrasound imaging was performed in four healthy volunteers using our new solid gel and the conventional liquid gel. Linear, convex, and sector probes were used for imaging of the common carotid artery and thyroid gland, liver, and parasternal four-chamber view, respectively. Image quality and volunteers\u2019 satisfaction were assessed using the 5-point Likert scale. For all sites, no significant differences in the image quality parameters were observed between our solid and the conventional liquid gels. The mean satisfaction score was significantly higher for all sites when our solid gel was used. Image quality remained unchanged for all sites after the application of our solid gel. The quality of images acquired using the new gel was comparable to that of those acquired using the conventional gel. This preliminary evidence supports the use of our new solid gel for ultrasonography with all probes for various tissue types and depths.<\/jats:p>","DOI":"10.1038\/s41598-025-33208-y","type":"journal-article","created":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T10:02:34Z","timestamp":1768212154000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Feasibility study of a newly developed solid gel pad containing tamarind seed gum for diagnostic ultrasonography in human subjects"],"prefix":"10.1038","volume":"16","author":[{"given":"Takuya","family":"Uehara","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hajime","family":"Monzen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Megumi","family":"Ujifuku","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukinori","family":"Matsuo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yutaka","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,12]]},"reference":[{"key":"33208_CR1","doi-asserted-by":"publisher","first-page":"823","DOI":"10.3390\/mi16070823","volume":"16","author":"S Deng","year":"2025","unstructured":"Deng, S. et al. Coupling agents in acoustofluidics: Mechanisms, materials, and applications. Micromachines 16, 823. https:\/\/doi.org\/10.3390\/mi16070823 (2025).","journal-title":"Micromachines"},{"key":"33208_CR2","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/j.auec.2018.09.003","volume":"21","author":"W Varndell","year":"2018","unstructured":"Varndell, W., Topacio, M., Hagness, C., Lemon, H. & Tracy, D. Nurse-performed focused ultrasound in the emergency department: A systematic review. Australas Emerg. Care. 21, 121\u2013130. https:\/\/doi.org\/10.1016\/j.auec.2018.09.003 (2018).","journal-title":"Australas Emerg. Care"},{"key":"33208_CR3","doi-asserted-by":"publisher","first-page":"335","DOI":"10.3390\/diagnostics14030335","volume":"14","author":"M Kim","year":"2024","unstructured":"Kim, M., Yoon, K., Lee, S., Shin, M. S. & Kim, K. G. Development of an artificial soft solid gel using gelatin material for high-quality ultrasound diagnosis. Diagnostics (Basel). 14, 335. https:\/\/doi.org\/10.3390\/diagnostics14030335 (2024).","journal-title":"Diagnostics (Basel)"},{"key":"33208_CR4","unstructured":"JIS K6254:2010. Cellular Plastics and rubbers - Determination of Compression stress-strain Characteristics (Japanese Standards Association, 2010)."},{"key":"33208_CR5","doi-asserted-by":"publisher","first-page":"e949","DOI":"10.1093\/milmed\/usab422","volume":"188","author":"C Mount","year":"2023","unstructured":"Mount, C., Taylor, D., Skinner, C. & Grogan, S. Intravenous fluid bag as a substitute for gel standoff pad in musculoskeletal point-of-care ultrasound. Mil Med. 188, e949\u2013e952 (2023).","journal-title":"Mil Med."},{"key":"33208_CR6","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.5811\/westjem.2017.8.35606","volume":"18","author":"BM Krainin","year":"2017","unstructured":"Krainin, B. M. et al. Heated ultrasound gel and patient satisfaction with bedside ultrasound studies: the HUGS trial. West. J. Emerg. Med. 18, 1061\u20131067 (2017).","journal-title":"West. J. Emerg. Med."},{"key":"33208_CR7","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.wem.2022.12.005","volume":"34","author":"JN Wray","year":"2023","unstructured":"Wray, J. N. et al. Comparison of commonly carried liquids against commercial ultrasound gel for use in the backcountry setting. Wilderness Environ. Med. 34, 135\u2013142 (2023).","journal-title":"Wilderness Environ. Med."},{"key":"33208_CR8","doi-asserted-by":"publisher","unstructured":"Salmon, M. et al. Alternative ultrasound gel for a sustainable ultrasound program: application of human centered design. PLOS One. 10, e0134332; (2015). https:\/\/doi.org\/10.1371\/journal.pone.0134332 Erratum in: PLoS One. 10, e0138400; 10.1371\/journal.pone.0138400 (2015).","DOI":"10.1371\/journal.pone.0134332"},{"key":"33208_CR9","doi-asserted-by":"publisher","unstructured":"Afzal, S. et al. Ultrasound hydrogel: A review on materials and method. J. Mod. Polym. Chem. Mater. 1, 2; (2022). https:\/\/doi.org\/10.53964\/jmpcm.2022002","DOI":"10.53964\/jmpcm.2022002"},{"key":"33208_CR10","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1177\/10806032241259938","volume":"35","author":"SM Todorovich","year":"2024","unstructured":"Todorovich, S. M., Van Aarsen, K., Freeman, S. R., Slomer, A. & Myslik, F. 3\u00a0M\u2122 defib-pads as a reusable alternative to commercial ultrasound gel in resource-limited settings. Wilderness Environ. Med. 35, 301\u2013307 (2024).","journal-title":"Wilderness Environ. Med."},{"key":"33208_CR11","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1136\/emermed-2016-206169","volume":"34","author":"C Riguzzi","year":"2017","unstructured":"Riguzzi, C. et al. A randomised experiment comparing low-cost ultrasound gel alternative with commercial gel. Emerg. Med. J. 34, 227\u2013230 (2017).","journal-title":"Emerg. Med. J."},{"key":"33208_CR12","doi-asserted-by":"publisher","first-page":"100207","DOI":"10.1016\/j.crgsc.2021.100207","volume":"4","author":"B Brailson Mansingh","year":"2022","unstructured":"Brailson Mansingh, B. et al. Sustainable development in utilization of tamarindus indica L. and its by-products in industries: A review. Curr. Res. Green. Sustain. Chem. 4, 100207. https:\/\/doi.org\/10.1016\/j.crgsc.2021.100207 (2022).","journal-title":"Curr. Res. Green. Sustain. Chem."},{"key":"33208_CR13","unstructured":"International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH). Q1A(R2): Stability testing of new drug substances and products. Geneva: ICH; (2003)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-33208-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-33208-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-33208-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T16:03:43Z","timestamp":1781625823000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-33208-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,12]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["33208"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-33208-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,12]]},"assertion":[{"value":"5 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Hajime Monzen received a research donation from Hayakawa Rubber Co., Ltd.All other authors have no competing interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"104"}}