{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T17:03:05Z","timestamp":1781629385414,"version":"3.54.5"},"reference-count":56,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T00:00:00Z","timestamp":1767830400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,1,11]],"date-time":"2026-01-11T00:00:00Z","timestamp":1768089600000},"content-version":"vor","delay-in-days":3,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Medizinische Fakult\u00e4t Heidelberg der Universit\u00e4t Heidelberg"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Photon-counting CT (PCCT) is the mainstay of multi-spectral imaging, enabling quantitative tissue characterization. In radiation oncology, cone-beam CT is used daily for image-guided and online-adaptive radiotherapy. The novel HyperSight cone-beam CT imaging mode (CBCT), with enhanced image quality due in part to its enlarged detector size and optimized reconstruction modes, further facilitates quantitative image monitoring and high-precision radiotherapy. Integrating spectral PCCT information may further amplify its potential. Therefore, this study investigates whether qualitative and spectral quantitative PCCT-parameters can be translated to CBCT. An inorganic tissue-equivalent anthropomorphic phantom analysis was conducted using CBCT (iCBCT\/iCBCT Acuros reconstruction, Pelvis\/Pelvis Large preset) and PCCT (T3D (polychromatic reconstruction) with virtual monochromatic imaging (VMI)). Twenty regions with different CT numbers were assessed qualitatively and quantitatively. Image quality was highest for T3D PCCT. Quantitative analysis showed stronger agreement between CBCT (iCBCT Acuros) and PCCT-derived 60 and 67\u00a0keV VMI (concordance correlation coefficient (CCC)\u2009\u2265\u20090.595), compared to T3D (CCC\u2009\u2264\u20090.183), with CCC values significantly affected by CBCT presets and reconstruction method (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009\u2264\u20090.001). Machine learning-based hierarchical clustering confirmed alignment between CBCT and PCCT-based VMI, but not T3D. This successful translatability of specific VMI levels paves the way for the integration of multi-spectral imaging into high-precision CBCT-based radiotherapy using PCCT.\n                  <\/jats:p>","DOI":"10.1038\/s41598-025-33888-6","type":"journal-article","created":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T10:46:40Z","timestamp":1767869200000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Multispectral PCCT and CBCT imaging for high precision radiotherapy through translation of imaging parameters with machine learning validation"],"prefix":"10.1038","volume":"16","author":[{"given":"Constantin","family":"Dreher","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhinay","family":"Vellala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor","family":"Siefert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florian","family":"Haag","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Sawall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jens","family":"Fleckenstein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sven","family":"Clausen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Judit","family":"Boda-Heggemann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan O.","family":"Schoenberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank A.","family":"Giordano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Froelich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,8]]},"reference":[{"issue":"1","key":"33888_CR1","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1148\/radiol.212579","volume":"303","author":"K Rajendran","year":"2022","unstructured":"Rajendran, K. et al. First clinical Photon-counting detector CT system: technical evaluation. Radiology 303 (1), 130\u2013138 (2022).","journal-title":"Radiology"},{"issue":"7","key":"33888_CR2","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1007\/s00066-023-02086-6","volume":"199","author":"S Cilla","year":"2023","unstructured":"Cilla, S. et al. CT-based radiomics prediction of complete response after stereotactic body radiation therapy for patients with lung metastases. Strahlenther Onkol. 199 (7), 676\u2013685 (2023).","journal-title":"Strahlenther Onkol"},{"issue":"1","key":"33888_CR3","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1186\/s13014-024-02468-9","volume":"19","author":"Z Li","year":"2024","unstructured":"Li, Z. et al. Quantitative parameter analysis of pretreatment dual-energy computed tomography in nasopharyngeal carcinoma cervical lymph node characteristics and prediction of radiotherapy sensitivity. Radiat. Oncol. 19 (1), 81 (2024).","journal-title":"Radiat. Oncol."},{"issue":"3","key":"33888_CR4","doi-asserted-by":"publisher","first-page":"703","DOI":"10.4251\/wjgo.v14.i3.703","volume":"14","author":"G Rossi","year":"2022","unstructured":"Rossi, G. et al. Computed tomography-based radiomic to predict resectability in locally advanced pancreatic cancer treated with chemotherapy and radiotherapy. World J. Gastrointest. Oncol. 14 (3), 703\u2013715 (2022).","journal-title":"World J. Gastrointest. Oncol."},{"issue":"1","key":"33888_CR5","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1007\/s00261-023-04042-5","volume":"49","author":"JA Decker","year":"2024","unstructured":"Decker, J. A. et al. Optimal conspicuity of pancreatic ductal adenocarcinoma in virtual monochromatic imaging reconstructions on a photon-counting detector CT: comparison to conventional MDCT. Abdom. Radiol. (NY). 49 (1), 103\u2013116 (2024).","journal-title":"Abdom. Radiol. (NY)"},{"issue":"11","key":"33888_CR6","doi-asserted-by":"publisher","first-page":"774","DOI":"10.1097\/RLI.0000000000001087","volume":"59","author":"F Homayounieh","year":"2024","unstructured":"Homayounieh, F. et al. A prospective study of the diagnostic performance of Photon-Counting CT compared with MRI in the characterization of renal masses. Invest. Radiol. 59 (11), 774\u2013781 (2024).","journal-title":"Invest. Radiol."},{"issue":"3","key":"33888_CR7","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1002\/mp.13396","volume":"46","author":"B Cai","year":"2019","unstructured":"Cai, B. et al. Characterization of a prototype rapid kilovoltage x-ray image guidance system designed for a ring shape radiation therapy unit. Med. Phys. 46 (3), 1355\u20131370 (2019).","journal-title":"Med. Phys."},{"issue":"7","key":"33888_CR8","doi-asserted-by":"publisher","first-page":"1470","DOI":"10.1002\/1878-0261.12751","volume":"14","author":"V Gr\u00e9goire","year":"2020","unstructured":"Gr\u00e9goire, V. et al. Image guidance in radiation therapy for better cure of cancer. Mol. Oncol. 14 (7), 1470\u20131491 (2020).","journal-title":"Mol. Oncol."},{"issue":"4","key":"33888_CR9","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1016\/j.ijrobp.2014.12.017","volume":"91","author":"RC Wortel","year":"2015","unstructured":"Wortel, R. C. et al. Acute toxicity after image-guided intensity modulated radiation therapy compared to 3D conformal radiation therapy in prostate cancer patients. Int. J. Radiat. Oncol. Biol. Phys. 91 (4), 737\u2013744 (2015).","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"2","key":"33888_CR10","doi-asserted-by":"publisher","first-page":"680","DOI":"10.1016\/j.ijrobp.2016.01.031","volume":"95","author":"RC Wortel","year":"2016","unstructured":"Wortel, R. C. et al. Late side effects after image guided intensity modulated radiation therapy compared to 3D-Conformal radiation therapy for prostate cancer: results from 2 prospective cohorts. Int. J. Radiat. Oncol. Biol. Phys. 95 (2), 680\u2013689 (2016).","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"3","key":"33888_CR11","doi-asserted-by":"publisher","first-page":"227","DOI":"10.2334\/josnusd.54.227","volume":"54","author":"B Bechara","year":"2012","unstructured":"Bechara, B. et al. Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines. J. Oral Sci. 54 (3), 227\u2013232 (2012).","journal-title":"J. Oral Sci."},{"issue":"6","key":"33888_CR12","doi-asserted-by":"publisher","first-page":"440","DOI":"10.4103\/2231-0762.170523","volume":"5","author":"AK Nagarajappa","year":"2015","unstructured":"Nagarajappa, A. K., Dwivedi, N. & Tiwari, R. Artifacts: the downturn of CBCT image. J. Int. Soc. Prev. Community Dent. 5 (6), 440\u2013445 (2015).","journal-title":"J. Int. Soc. Prev. Community Dent."},{"key":"33888_CR13","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1007\/s11282-011-0071-z","volume":"27","author":"J Chindasombatjaroen","year":"2011","unstructured":"Chindasombatjaroen, J. et al. Quantitative analysis of metallic artifacts caused by dental metals: comparison of cone-beam and multi-detector row CT scanners. Oral Radiol. 27, 114\u2013120 (2011).","journal-title":"Oral Radiol."},{"issue":"9","key":"33888_CR14","first-page":"e778","volume":"8","author":"L Lechuga","year":"2016","unstructured":"Lechuga, L. & Weidlich, G. A. Cone beam CT vs. Fan beam CT: A comparison of image quality and dose delivered between two differing CT imaging modalities. Cureus 8 (9), e778 (2016).","journal-title":"Cureus"},{"key":"33888_CR15","doi-asserted-by":"publisher","unstructured":"Balbi, M. et al. Longitudinal changes of CT-radiomic and systemic inflammatory features predict survival in advanced Non-Small cell lung cancer patients treated with immune checkpoint inhibitors. J. Thorac. Imaging 40, e0801. https:\/\/doi.org\/10.1097\/rti.0000000000000801 (2025).","DOI":"10.1097\/rti.0000000000000801"},{"issue":"1","key":"33888_CR16","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1186\/s13014-022-02136-w","volume":"17","author":"NB Chen","year":"2022","unstructured":"Chen, N. B. et al. CT radiomics-based long-term survival prediction for locally advanced non-small cell lung cancer patients treated with concurrent chemoradiotherapy using features from tumor and tumor organismal environment. Radiat. Oncol. 17 (1), 184 (2022).","journal-title":"Radiat. Oncol."},{"key":"33888_CR17","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.radonc.2019.03.032","volume":"136","author":"JE van Timmeren","year":"2019","unstructured":"van Timmeren, J. E. et al. Longitudinal radiomics of cone-beam CT images from non-small cell lung cancer patients: evaluation of the added prognostic value for overall survival and locoregional recurrence. Radiother Oncol. 136, 78\u201385 (2019).","journal-title":"Radiother Oncol."},{"issue":"5","key":"33888_CR18","doi-asserted-by":"publisher","first-page":"e14299","DOI":"10.1002\/acm2.14299","volume":"25","author":"A Haertter","year":"2024","unstructured":"Haertter, A. et al. ACR benchmark testing of a novel high-speed ring-gantry Linac kV-CBCT system. J. Appl. Clin. Med. Phys. 25 (5), e14299 (2024).","journal-title":"J. Appl. Clin. Med. Phys."},{"issue":"5","key":"33888_CR19","doi-asserted-by":"publisher","first-page":"e14337","DOI":"10.1002\/acm2.14337","volume":"25","author":"E Kim","year":"2024","unstructured":"Kim, E. et al. Image quality characterization of an ultra-high-speed kilovoltage cone-beam computed tomography imaging system on an O-ring linear accelerator. J. Appl. Clin. Med. Phys. 25 (5), e14337 (2024).","journal-title":"J. Appl. Clin. Med. Phys."},{"issue":"10","key":"33888_CR20","doi-asserted-by":"publisher","first-page":"105018","DOI":"10.1088\/1361-6560\/ad3cb0","volume":"69","author":"D Lustermans","year":"2024","unstructured":"Lustermans, D. et al. Image quality evaluation of a new high-performance ring-gantry cone-beam computed tomography imager. Phys. Med. Biol. 69 (10), 105018 (2024).","journal-title":"Phys. Med. Biol."},{"key":"33888_CR21","unstructured":"Varian HyperSight: A revolution in resolution (HyperSight Brochure RAD11063A). 2023. Available from: https:\/\/varian.widen.net\/s\/sd5kdw7wxv\/hypersight_brochure_rad11063_oct2022 (2024)."},{"key":"33888_CR22","doi-asserted-by":"publisher","first-page":"110458","DOI":"10.1016\/j.radonc.2024.110458","volume":"200","author":"B Kunnen","year":"2024","unstructured":"Kunnen, B. et al. The added value of a new high-performance ring-gantry CBCT imaging system for prostate cancer patients. Radiother Oncol. 200, 110458 (2024).","journal-title":"Radiother Oncol."},{"issue":"2","key":"33888_CR23","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1148\/radiol.211931","volume":"303","author":"T Sartoretti","year":"2022","unstructured":"Sartoretti, T. et al. Quantum iterative reconstruction for abdominal Photon-counting detector CT improves image quality. Radiology 303 (2), 339\u2013348 (2022).","journal-title":"Radiology"},{"key":"33888_CR24","doi-asserted-by":"publisher","first-page":"153303381882305","DOI":"10.1177\/1533033818823054","volume":"18","author":"W Mao","year":"2019","unstructured":"Mao, W. et al. Evaluation and clinical application of a commercially available iterative reconstruction algorithm for CBCT-Based IGRT. Technol. Cancer Res. Treat. 18, 1533033818823054 (2019).","journal-title":"Technol. Cancer Res. Treat."},{"issue":"5","key":"33888_CR25","doi-asserted-by":"publisher","first-page":"1914","DOI":"10.1002\/mp.12849","volume":"45","author":"A Wang","year":"2018","unstructured":"Wang, A. et al. Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part II: system modeling, scatter correction, and optimization. Med. Phys. 45 (5), 1914\u20131925 (2018).","journal-title":"Med. Phys."},{"key":"33888_CR26","doi-asserted-by":"publisher","first-page":"153303382110673","DOI":"10.1177\/15330338211067312","volume":"21","author":"H Washio","year":"2022","unstructured":"Washio, H. et al. Dose reduction and Low-Contrast detectability using iterative CBCT reconstruction algorithm for radiotherapy. Technol. Cancer Res. Treat. 21, 15330338211067312 (2022).","journal-title":"Technol. Cancer Res. Treat."},{"key":"33888_CR27","unstructured":"de Winter, J. C. F. & Dodou, D. Five-point Likert Items: T Test Versus Mann\u2013Whitney\u2013Wilcoxon Vol. 15, p. 16 (Practical Assessment, Research & Evaluation, 2010). 11."},{"issue":"1","key":"33888_CR28","doi-asserted-by":"publisher","first-page":"e13468","DOI":"10.1002\/acm2.13468","volume":"23","author":"MF Kruis","year":"2022","unstructured":"Kruis, M. F. Improving radiation physics, tumor visualisation, and treatment quantification in radiotherapy with spectral or dual-energy CT. J. Appl. Clin. Med. Phys. 23 (1), e13468 (2022).","journal-title":"J. Appl. Clin. Med. Phys."},{"issue":"6","key":"33888_CR29","doi-asserted-by":"publisher","first-page":"e0157072","DOI":"10.1371\/journal.pone.0157072","volume":"11","author":"CC Yang","year":"2016","unstructured":"Yang, C. C., Chen, F. L. & Lo, Y. C. Improving image quality of On-Board Cone-Beam CT in radiation therapy using image information provided by planning Multi-Detector CT: A Phantom study. PLOS ONE. 11 (6), e0157072 (2016).","journal-title":"PLOS ONE"},{"key":"33888_CR30","doi-asserted-by":"crossref","unstructured":"Suwanraksa, C., Bridhikitti, J., Liamsuwan, T. & Chaichulee, S. CBCT-to-CT translation using Registration-Based generative adversarial networks in patients with head and neck cancer. Cancers (Basel) 15, 2017 (2023).","DOI":"10.3390\/cancers15072017"},{"key":"33888_CR31","doi-asserted-by":"publisher","unstructured":"Viar-Hernandez, D. et al. Exploring dual energy CT synthesis in CBCT-based adaptive radiotherapy and proton therapy: application of denoising diffusion probabilistic models. Phys. Med. Biol. 69, 215011. https:\/\/doi.org\/10.1088\/1361-6560\/ad8547 (2024).","DOI":"10.1088\/1361-6560\/ad8547"},{"issue":"10","key":"33888_CR32","doi-asserted-by":"publisher","first-page":"6056","DOI":"10.1118\/1.4752212","volume":"39","author":"H Li","year":"2012","unstructured":"Li, H. et al. Implementation of dual-energy technique for virtual monochromatic and linearly mixed CBCTs. Med. Phys. 39 (10), 6056\u20136064 (2012).","journal-title":"Med. Phys."},{"issue":"10","key":"33888_CR33","doi-asserted-by":"publisher","first-page":"1483","DOI":"10.1080\/0284186X.2019.1629010","volume":"58","author":"M Skaarup","year":"2019","unstructured":"Skaarup, M. et al. Dual-energy material decomposition for cone-beam computed tomography in image-guided radiotherapy. Acta Oncol. 58 (10), 1483\u20131488 (2019).","journal-title":"Acta Oncol."},{"issue":"11","key":"33888_CR34","doi-asserted-by":"publisher","first-page":"6762","DOI":"10.1002\/mp.16711","volume":"50","author":"Z Wang","year":"2023","unstructured":"Wang, Z. et al. Dual-energy head cone-beam CT using a dual-layer flat-panel detector: hybrid material decomposition and a feasibility study. Med. Phys. 50 (11), 6762\u20136778 (2023).","journal-title":"Med. Phys."},{"issue":"1","key":"33888_CR35","doi-asserted-by":"publisher","first-page":"9886","DOI":"10.1038\/s41598-024-60774-4","volume":"14","author":"B Li","year":"2024","unstructured":"Li, B. et al. Low-cost dual-energy CBCT by spectral filtration of a dual focal spot X-ray source. Sci. Rep. 14 (1), 9886 (2024).","journal-title":"Sci. Rep."},{"issue":"1069","key":"33888_CR36","doi-asserted-by":"publisher","first-page":"20160480","DOI":"10.1259\/bjr.20160480","volume":"90","author":"LE Schyns","year":"2017","unstructured":"Schyns, L. E. et al. Optimizing dual energy cone beam CT protocols for preclinical imaging and radiation research. Br. J. Radiol. 90 (1069), 20160480 (2017).","journal-title":"Br. J. Radiol."},{"issue":"3","key":"33888_CR37","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1148\/radiol.2017162587","volume":"285","author":"R Symons","year":"2017","unstructured":"Symons, R. et al. Feasibility of Dose-reduced chest CT with Photon-counting detectors: initial results in humans. Radiology 285 (3), 980\u2013989 (2017).","journal-title":"Radiology"},{"issue":"3","key":"33888_CR38","doi-asserted-by":"publisher","first-page":"1466","DOI":"10.3390\/tomography8030119","volume":"8","author":"F Hagen","year":"2022","unstructured":"Hagen, F. et al. Image quality and radiation dose of Contrast-Enhanced Chest-CT acquired on a clinical Photon-Counting detector CT vs. Second-Generation Dual-Source CT in an oncologic cohort: preliminary results. Tomography 8 (3), 1466\u20131476 (2022).","journal-title":"Tomography"},{"key":"33888_CR39","doi-asserted-by":"publisher","first-page":"110829","DOI":"10.1016\/j.ejrad.2023.110829","volume":"163","author":"J van der Bie","year":"2023","unstructured":"van der Bie, J. et al. Photon-counting CT: review of initial clinical results. Eur. J. Radiol. 163, 110829 (2023).","journal-title":"Eur. J. Radiol."},{"issue":"6","key":"33888_CR40","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1097\/RLI.0000000000000848","volume":"57","author":"L Jungblut","year":"2022","unstructured":"Jungblut, L. et al. Impact of contrast enhancement and virtual monoenergetic image energy levels on emphysema quantification: experience with Photon-Counting detector computed tomography. Invest. Radiol. 57 (6), 359\u2013365 (2022).","journal-title":"Invest. Radiol."},{"issue":"2","key":"33888_CR41","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1097\/RCT.0000000000001562","volume":"48","author":"B Dane","year":"2024","unstructured":"Dane, B. et al. Photon-Counting computed tomography versus Energy-Integrating Dual-Energy computed tomography: virtual Noncontrast image quality comparison. J. Comput. Assist. Tomogr. 48 (2), 251\u2013256 (2024).","journal-title":"J. Comput. Assist. Tomogr"},{"issue":"2","key":"33888_CR42","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1148\/radiol.2018180126","volume":"289","author":"RP Marcus","year":"2018","unstructured":"Marcus, R. P. et al. Detection and characterization of renal stones by using Photon-Counting-based CT. Radiology 289 (2), 436\u2013442 (2018).","journal-title":"Radiology"},{"issue":"9","key":"33888_CR43","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1097\/RLI.0000000000000873","volume":"57","author":"FSL Thomsen","year":"2022","unstructured":"Thomsen, F. S. L. et al. Effective Spatial resolution of photon counting CT for imaging of trabecular structures is superior to conventional clinical CT and similar to high resolution peripheral CT. Invest. Radiol. 57 (9), 620\u2013626 (2022).","journal-title":"Invest. Radiol."},{"key":"33888_CR44","doi-asserted-by":"publisher","first-page":"4006","DOI":"10.1038\/ncomms5006","volume":"5","author":"HJ Aerts","year":"2014","unstructured":"Aerts, H. J. et al. Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach. Nat. Commun. 5, 4006 (2014).","journal-title":"Nat. Commun."},{"issue":"1","key":"33888_CR45","doi-asserted-by":"publisher","first-page":"6654","DOI":"10.1038\/s41467-021-26990-6","volume":"12","author":"L Lu","year":"2021","unstructured":"Lu, L. et al. Deep learning for the prediction of early on-treatment response in metastatic colorectal cancer from serial medical imaging. Nat. Commun. 12 (1), 6654 (2021).","journal-title":"Nat. Commun."},{"issue":"2","key":"33888_CR46","doi-asserted-by":"publisher","first-page":"740","DOI":"10.3390\/tomography8020061","volume":"8","author":"AJ Allphin","year":"2022","unstructured":"Allphin, A. J. et al. Photon counting CT and radiomic analysis enables differentiation of tumors based on lymphocyte burden. Tomography 8 (2), 740\u2013753 (2022).","journal-title":"Tomography"},{"issue":"1","key":"33888_CR47","doi-asserted-by":"publisher","first-page":"e222432","DOI":"10.1148\/radiol.222432","volume":"309","author":"PC Douek","year":"2023","unstructured":"Douek, P. C. et al. Clinical applications of Photon-counting CT: A review of pioneer studies and a glimpse into the future. Radiology 309 (1), e222432 (2023).","journal-title":"Radiology"},{"key":"33888_CR48","doi-asserted-by":"publisher","unstructured":"Shah, K. D. et al. Photon-counting CT in cancer radiotherapy: technological advances and clinical benefits. Phys. Med. Biol. 70(10), 10TR01. https:\/\/doi.org\/10.1088\/1361-6560\/add4ba (2025).","DOI":"10.1088\/1361-6560\/add4ba"},{"issue":"1","key":"33888_CR49","doi-asserted-by":"publisher","first-page":"19594","DOI":"10.1038\/s41598-022-22877-8","volume":"12","author":"H Tharmaseelan","year":"2022","unstructured":"Tharmaseelan, H. et al. Evaluation of radiomics feature stability in abdominal monoenergetic photon counting CT reconstructions. Sci. Rep. 12 (1), 19594 (2022).","journal-title":"Sci. Rep."},{"issue":"9","key":"33888_CR50","doi-asserted-by":"publisher","first-page":"5585","DOI":"10.1002\/mp.16376","volume":"50","author":"T Adachi","year":"2023","unstructured":"Adachi, T. et al. Identification of reproducible radiomic features from on-board volumetric images: A multi-institutional Phantom study. Med. Phys. 50 (9), 5585\u20135596 (2023).","journal-title":"Med. Phys."},{"issue":"3","key":"33888_CR51","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/j.prro.2023.10.014","volume":"14","author":"JL Robar","year":"2024","unstructured":"Robar, J. L. et al. Novel technology allowing cone beam computed tomography in 6 seconds: A patient study of comparative image quality. Pract. Radiat. Oncol. 14 (3), 277\u2013286 (2024).","journal-title":"Pract. Radiat. Oncol."},{"key":"33888_CR52","unstructured":"Shah, K. D. et al. Photon-Counting CT in Cancer Radiotherapy: Technological Advances and Clinical Benefits. ArXiv, (2024)."},{"issue":"5","key":"33888_CR53","doi-asserted-by":"publisher","first-page":"1316","DOI":"10.1016\/j.ijrobp.2024.11.069","volume":"121","author":"J Zimmerman","year":"2025","unstructured":"Zimmerman, J. & Poludniowski, G. Assessment of Photon-Counting computed tomography for quantitative imaging in radiation therapy. Int. J. Radiat. Oncol. Biol. Phys. 121 (5), 1316\u20131327 (2025).","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"4","key":"33888_CR54","doi-asserted-by":"publisher","first-page":"539","DOI":"10.2214\/AJR.23.29463","volume":"221","author":"AM Salyapongse","year":"2023","unstructured":"Salyapongse, A. M. et al. CT number accuracy and association with object size: A Phantom study comparing Energy-Integrating detector CT and deep silicon Photon-Counting detector CT. Am. J. Roentgenol. 221 (4), 539\u2013547 (2023).","journal-title":"Am. J. Roentgenol."},{"issue":"1169","key":"33888_CR55","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1093\/bjr\/tqaf052","volume":"98","author":"JD Flores","year":"2025","unstructured":"Flores, J. D. et al. Clinical photon-counting CT increases CT number precision and reduces patient size dependence compared to single- and dual-energy CT. Br. J. Radiol. 98 (1169), 721\u2013733 (2025).","journal-title":"Br. J. Radiol."},{"issue":"4","key":"33888_CR56","doi-asserted-by":"publisher","first-page":"1846","DOI":"10.1002\/mp.14756","volume":"48","author":"Y Park","year":"2021","unstructured":"Park, Y. et al. Evaluation of scatter rejection and correction performance of 2D antiscatter grids in cone beam computed tomography. Med. Phys. 48 (4), 1846\u20131858 (2021).","journal-title":"Med. Phys."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-33888-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-33888-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-33888-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T16:18:24Z","timestamp":1781626704000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-33888-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,8]]},"references-count":56,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["33888"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-33888-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,8]]},"assertion":[{"value":"16 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"C.D. reports Varian research grant and travel expenses, AstraZeneca speaker fees and travel expenses, and DGVS speaker fees and travel expenses. F.A.G. reports travel expenses, stocks and honoraria from TME Pharma AG; research grants and travel expenses from ELEKTA AB; grants, research grants, travel expenses and honoraria from Carl Zeiss Meditec AG; grants, research grants, travel expenses and honoraria from Biotex, Inc. and GUERBET S.A.; travel expenses and research grants from Varian Medical Systems, Inc.; travel expenses and \/or honoraria from Siemens Healthineers AG, Varian Medical Systems, and AstraZeneca GmbH; non-financial support from Heberger GmbH, Oncare GmbH and Opasca GmbH and patent US10857388B2 together with Carl Zeiss MeditecAG.\u00a0All other authors have no competing interests to declare.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1290"}}