{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T01:48:18Z","timestamp":1791942498612,"version":"4.3.4"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T00:00:00Z","timestamp":1767657600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T00:00:00Z","timestamp":1769731200000},"content-version":"vor","delay-in-days":24,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-025-34337-0","type":"journal-article","created":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T07:53:11Z","timestamp":1767685991000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Upper limb compensatory strategies across tasks with an ultrasound-controlled prosthesis"],"prefix":"10.1038","volume":"16","author":[{"given":"Halla","family":"Hussein Hakami","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruno Grandi","family":"Sgambato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew S.","family":"Banger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dario","family":"Farina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alison H.","family":"McGregor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,6]]},"reference":[{"key":"34337_CR1","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1097\/JPO.0b013e31817ecb16","volume":"20","author":"C Gambrell","year":"2008","unstructured":"Gambrell, C. Overuse syndrome and the unilateral upper limb amputee: Consequences and prevention. JPO J. Prosth. Orthotics20, 126\u2013132 (2008).","journal-title":"JPO J. Prosth. Orthotics"},{"key":"34337_CR2","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1109\/TNSRE.2015.2398112","volume":"23","author":"F Montagnani","year":"2015","unstructured":"Montagnani, F., Controzzi, M. & Cipriani, C. Is it finger or wrist dexterity that is missing in current hand prostheses?. IEEE Trans. Neural Syst. Rehabil. Eng.23, 600\u2013609 (2015).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"34337_CR3","doi-asserted-by":"publisher","first-page":"328","DOI":"10.3390\/biomimetics8030328","volume":"8","author":"Z Chen","year":"2023","unstructured":"Chen, Z. et al. A review of myoelectric control for prosthetic hand manipulation. Biomimetics8, 328. https:\/\/doi.org\/10.3390\/biomimetics8030328 (2023).","journal-title":"Biomimetics"},{"key":"34337_CR4","doi-asserted-by":"publisher","first-page":"e0289978","DOI":"10.1371\/journal.pone.0289978","volume":"18","author":"P Capsi-Morales","year":"2023","unstructured":"Capsi-Morales, P. et al. Functional assessment of current upper limb prostheses: An integrated clinical and technological perspective. PLOS ONE18, e0289978. https:\/\/doi.org\/10.1371\/journal.pone.0289978 (2023).","journal-title":"PLOS ONE"},{"key":"34337_CR5","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1109\/TMECH.2007.901936","volume":"12","author":"L Zollo","year":"2007","unstructured":"Zollo, L. et al. Biomechatronic design and control of an anthropomorphic artificial hand for prosthetic and robotic applications. IEEE\/ASME Trans. Mech.12, 418\u2013429 (2007).","journal-title":"IEEE\/ASME Trans. Mech."},{"key":"34337_CR6","doi-asserted-by":"publisher","first-page":"066022","DOI":"10.1088\/1741-2560\/12\/6\/066022","volume":"12","author":"M Markovic","year":"2015","unstructured":"Markovic, M. et al. Sensor fusion and computer vision for context-aware control of a multi degree-of-freedom prosthesis. J. Neural Eng.12, 066022 (2015).","journal-title":"J. Neural Eng."},{"key":"34337_CR7","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1186\/s12984-019-0609-6","volume":"16","author":"S Cai","year":"2019","unstructured":"Cai, S. et al. Detecting compensatory movements of stroke survivors using pressure distribution data and machine learning algorithms. J. NeuroEng. Rehabil.16, 131 (2019).","journal-title":"J. NeuroEng. Rehabil."},{"key":"34337_CR8","doi-asserted-by":"publisher","first-page":"1128","DOI":"10.1016\/j.clinbiomech.2008.05.008","volume":"23","author":"S Carey","year":"2008","unstructured":"Carey, S. et al. Compensatory movements of transradial prosthesis users during common tasks. Clin. Biomech.23, 1128\u20131135 (2008).","journal-title":"Clin. Biomech."},{"key":"34337_CR9","unstructured":"Sanders, M. & McCormick, E. Human Factors in Engineering Design . 6th Ed. (McGraw-Hill, 1987)."},{"key":"34337_CR10","first-page":"8","volume":"10","author":"D Stegeman","year":"2007","unstructured":"Stegeman, D. & Hermens, H. Standards for surface electromyography: The European project surface EMG for non-invasive assessment of muscles (SENIAM). Enschede Roessingh Res. Dev.10, 8\u201312 (2007).","journal-title":"Enschede Roessingh Res. Dev."},{"key":"34337_CR11","volume-title":"Electrode Placement in EMG Biofeedback","author":"J Basmajian","year":"1980","unstructured":"Basmajian, J. & Blumenstein, R. Electrode Placement in EMG Biofeedback (Williams, 1980)."},{"key":"34337_CR12","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1109\/TBME.2022.3202250","volume":"70","author":"I Vujaklija","year":"2023","unstructured":"Vujaklija, I. et al. Biomechanical analysis of body movements of myoelectric prosthesis users during standardized clinical tests. IEEE Trans. Biomed. Eng.70, 789\u2013799. https:\/\/doi.org\/10.1109\/TBME.2022.3202250 (2023).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"34337_CR13","unstructured":"Perotto, A. O. Anatomical Guide for the Electromyographer: The Limbs and Trunk. 5th Ed. (Charles C Thomas Publisher, 2011)."},{"key":"34337_CR14","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1016\/j.jbiomech.2004.05.042","volume":"38","author":"G Wu","year":"2005","unstructured":"Wu, G. et al. Isb recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion-part II: Shoulder, elbow, wrist and hand. J. Biomech.38, 981\u2013992. https:\/\/doi.org\/10.1016\/j.jbiomech.2004.05.042 (2005).","journal-title":"J. Biomech."},{"key":"34337_CR15","unstructured":"Gait, V.-I. Product Guide-Foundation Notes (Unpublished, 2010)."},{"key":"34337_CR16","doi-asserted-by":"publisher","first-page":"e0177965","DOI":"10.1371\/journal.pone.0177965","volume":"12","author":"K Kontson","year":"2017","unstructured":"Kontson, K. et al. Targeted box and blocks test: Normative data and comparison to standard tests. PLOS ONE12, e0177965. https:\/\/doi.org\/10.1371\/journal.pone.0177965 (2017).","journal-title":"PLOS ONE"},{"key":"34337_CR17","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.clinbiomech.2019.12.002","volume":"72","author":"A Valevicius","year":"2020","unstructured":"Valevicius, A. et al. Compensatory strategies of body-powered prosthesis users reveal primary reliance on trunk motion and relation to skill level. Clin. Biomech.72, 122\u2013129 (2020).","journal-title":"Clin. Biomech."},{"key":"34337_CR18","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1177\/0309364616675746","volume":"41","author":"A Hussaini","year":"2017","unstructured":"Hussaini, A. & Kyberd, P. Refined clothespin relocation test and assessment of motion. Prosth. Orthot. Int.41, 294\u2013302. https:\/\/doi.org\/10.1177\/0309364616675746 (2017).","journal-title":"Prosth. Orthot. Int."},{"key":"34337_CR19","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1177\/0309364616675745","volume":"41","author":"A Hussaini","year":"2017","unstructured":"Hussaini, A., Zinck, A. & Kyberd, P. Categorization of compensatory motions in transradial myoelectric prosthesis users. Prosth. Orthot. Int.41, 286\u2013293. https:\/\/doi.org\/10.1177\/0309364616675745 (2017).","journal-title":"Prosth. Orthot. Int."},{"key":"34337_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12984-020-00744-1","volume":"17","author":"C Adans-Dester","year":"2020","unstructured":"Adans-Dester, C. et al. Can kinematic parameters of 3D reach-to-target movements be used as a proxy for clinical outcome measures in chronic stroke rehabilitation? An exploratory study. J. NeuroEng. Rehabil.17, 1\u201313. https:\/\/doi.org\/10.1186\/s12984-020-00744-1 (2020).","journal-title":"J. NeuroEng. Rehabil."},{"key":"34337_CR21","first-page":"870","volume":"12","author":"A Boyle","year":"2020","unstructured":"Boyle, A. et al. Capacity assessment of prosthetic performance for the upper limb (cappful): Characterization of normative kinematics and performance. PM &R12, 870\u2013881 (2020).","journal-title":"PM &R"},{"key":"34337_CR22","doi-asserted-by":"publisher","first-page":"e0199549","DOI":"10.1371\/journal.pone.0199549","volume":"13","author":"AM Valevicius","year":"2018","unstructured":"Valevicius, A. M. et al. Characterization of normative hand movements during two functional upper limb tasks. PLOS ONE13, e0199549. https:\/\/doi.org\/10.1371\/journal.pone.0199549 (2018).","journal-title":"PLOS ONE"},{"key":"34337_CR23","doi-asserted-by":"publisher","first-page":"2029","DOI":"10.1016\/j.apmr.2012.03.011","volume":"93","author":"A Metzger","year":"2012","unstructured":"Metzger, A. et al. Characterization of compensatory trunk movements during prosthetic upper limb reaching tasks. Arch. Phys. Med. Rehabil.93, 2029\u20132034 (2012).","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"34337_CR24","doi-asserted-by":"publisher","first-page":"1745","DOI":"10.1109\/TNSRE.2022.3186266","volume":"30","author":"M Legrand","year":"2022","unstructured":"Legrand, M. et al. Simultaneous control of 2D of upper-limb prosthesis with body compensations-based control: A multiple cases study. IEEE Trans. Neural Syst. Rehabil. Eng.30, 1745\u20131754. https:\/\/doi.org\/10.1109\/TNSRE.2022.3186266 (2022).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"34337_CR25","doi-asserted-by":"publisher","first-page":"105713","DOI":"10.1016\/j.clinbiomech.2022.105713","volume":"97","author":"S Engdahl","year":"2022","unstructured":"Engdahl, S., Lee, C. & Gates, D. A comparison of compensatory movements between body-powered and myoelectric prosthesis users during activities of daily living. Clin. Biomech.97, 105713 (2022).","journal-title":"Clin. Biomech."},{"key":"34337_CR26","doi-asserted-by":"publisher","first-page":"2303","DOI":"10.1161\/STROKEAHA.110.593368","volume":"41","author":"S Subramanian","year":"2010","unstructured":"Subramanian, S. et al. Validity of movement pattern kinematics as measures of arm motor impairment poststroke. Stroke41, 2303\u20132308 (2010).","journal-title":"Stroke"},{"key":"34337_CR27","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1177\/1545968310370748","volume":"25","author":"MA Murphy","year":"2011","unstructured":"Murphy, M. A., Will\u00e9n, C. & Sunnerhagen, K. S. Kinematic variables quantifying upper-extremity performance after stroke during reaching and drinking from a glass. Neurorehabil. Neural Repair25, 71\u201380. https:\/\/doi.org\/10.1177\/1545968310370748 (2011).","journal-title":"Neurorehabil. Neural Repair"},{"key":"34337_CR28","doi-asserted-by":"publisher","first-page":"e0226563","DOI":"10.1371\/journal.pone.0226563","volume":"15","author":"C Bloomer","year":"2020","unstructured":"Bloomer, C., Wang, S. & Kontson, K. Kinematic analysis of motor learning in upper limb body-powered bypass prosthesis training. PLOS ONE15, e0226563. https:\/\/doi.org\/10.1371\/journal.pone.0226563 (2020).","journal-title":"PLOS ONE"},{"key":"34337_CR29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1743-0003-11-132","volume":"11","author":"M Major","year":"2014","unstructured":"Major, M. et al. Comparison of range-of-motion and variability in upper body movements between transradial prosthesis users and able-bodied controls when executing goal-oriented tasks. J. NeuroEng. Rehabil.11, 1\u201310 (2014).","journal-title":"J. NeuroEng. Rehabil."},{"key":"34337_CR30","doi-asserted-by":"publisher","first-page":"6481","DOI":"10.3390\/s21196481","volume":"21","author":"M Fournelle","year":"2021","unstructured":"Fournelle, M. et al. Portable ultrasound research system for use in automated bladder monitoring with machine-learning-based segmentation. Sensors21, 6481. https:\/\/doi.org\/10.3390\/s21196481 (2021).","journal-title":"Sensors"},{"key":"34337_CR31","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1109\/TBME.2023.3307952","volume":"71","author":"BG Sgambato","year":"2024","unstructured":"Sgambato, B. G. et al. High performance wearable ultrasound as a human-machine interface for wrist and hand kinematic tracking. IEEE Trans. Biomed. Eng.71, 484\u2013493. https:\/\/doi.org\/10.1109\/TBME.2023.3307952 (2024).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"34337_CR32","doi-asserted-by":"crossref","unstructured":"Sgambato, B. G. et al. Towards natural multi-DOF prosthetic control with distributed ultrasound (2024).","DOI":"10.1109\/UFFC-JS60046.2024.10793502"},{"key":"34337_CR33","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1093\/ptj\/pzaa008","volume":"100","author":"R Gailey","year":"2020","unstructured":"Gailey, R. et al. Effectiveness of an evidence-based amputee rehabilitation program: A pilot randomized controlled trial. Phys. Ther.100, 773\u2013787 (2020).","journal-title":"Phys. Ther."},{"key":"34337_CR34","doi-asserted-by":"publisher","first-page":"1312","DOI":"10.12669\/pjms.325.9922","volume":"32","author":"K Soyer","year":"2016","unstructured":"Soyer, K. et al. The importance of rehabilitation concerning upper extremity amputees: A systematic review. Pak. J. Med. Sci.32, 1312 (2016).","journal-title":"Pak. J. Med. Sci."},{"key":"34337_CR35","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1097\/PXR.0000000000000037","volume":"45","author":"C Widehammar","year":"2021","unstructured":"Widehammar, C., Holmqvist, K. L. & Hermansson, L. Training for users of myoelectric multigrip hand prostheses: A scoping review. Prosth. Orthot. Int.45, 393\u2013400. https:\/\/doi.org\/10.1097\/PXR.0000000000000037 (2021).","journal-title":"Prosth. Orthot. Int."},{"key":"34337_CR36","unstructured":"Dillingham, T.\u00a0R. Rehabilitation of the Upper Limb Amputee. Vol.\u00a01. 33\u201377 (Office of the Surgeon General, United States Army, 1998)."},{"key":"34337_CR37","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1097\/JPO.0b013e3182515437","volume":"24","author":"A Simon","year":"2012","unstructured":"Simon, A., Lock, B. & Stubblefield, K. Patient training for functional use of pattern recognition-controlled prostheses. JPO J. Prosth. Orthot.24, 56\u201364 (2012).","journal-title":"JPO J. Prosth. Orthot."},{"key":"34337_CR38","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1038\/s41551-021-00732-x","volume":"7","author":"D Farina","year":"2023","unstructured":"Farina, D. et al. Toward higher-performance bionic limbs for wider clinical use. Nat. Biomed. Eng.7, 473\u2013485. https:\/\/doi.org\/10.1038\/s41551-021-00732-x (2023).","journal-title":"Nat. Biomed. Eng."},{"key":"34337_CR39","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1016\/j.gaitpost.2007.03.002","volume":"27","author":"C van Andel","year":"2008","unstructured":"van Andel, C. et al. Complete 3D kinematics of upper extremity functional tasks. Gait Posture27, 120\u2013127 (2008).","journal-title":"Gait Posture"},{"key":"34337_CR40","doi-asserted-by":"publisher","first-page":"109","DOI":"10.3109\/03093641003776976","volume":"34","author":"H Lindner","year":"2010","unstructured":"Lindner, H., N\u00e4tterlund, B. & Hermansson, L. Upper limb prosthetic outcome measures: Review and content comparison based on international classification of functioning, disability and health. Prosth. Orthot. Int.34, 109\u2013128 (2010).","journal-title":"Prosth. Orthot. Int."},{"key":"34337_CR41","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1016\/0021-9290(91)90334-J","volume":"24","author":"C H\u00f6gfors","year":"1991","unstructured":"H\u00f6gfors, C., Peterson, B., Sigholm, G. & Herberts, P. Biomechanical model of the human shoulder joint-II. The shoulder rhythm. J. Biomech.24, 699\u2013709. https:\/\/doi.org\/10.1016\/0021-9290(91)90334-J (1991).","journal-title":"J. Biomech."},{"key":"34337_CR42","doi-asserted-by":"publisher","first-page":"P13","DOI":"10.1097\/00008526-200601001-00004","volume":"18","author":"E Condie","year":"2006","unstructured":"Condie, E., Scott, H. & Treweek, S. Lower limb prosthetic outcome measures: A review of the literature 1995 to 2005. JPO J. Prosth. Orthot.18, P13\u2013P45 (2006).","journal-title":"JPO J. Prosth. Orthot."},{"key":"34337_CR43","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1243\/0954411001535570","volume":"214","author":"C Anglin","year":"2000","unstructured":"Anglin, C. & Wyss, U. P. Review of arm motion analyses. Proc. Inst. Mech. Eng. Part H J. Eng. Med.214, 541\u2013555. https:\/\/doi.org\/10.1243\/0954411001535570 (2000).","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"34337_CR44","unstructured":"World Health Organization. International Classification of Functioning, Disability and Health: ICF (World Health Organization, 2001)."},{"key":"34337_CR45","doi-asserted-by":"publisher","first-page":"P69","DOI":"10.1097\/JPO.0b013e3181ae970b","volume":"21","author":"W Hill","year":"2009","unstructured":"Hill, W. et al. Upper limb prosthetic outcome measures (ULPOM): A working group and their findings. JPO J. Prosth. Orthot.21, P69\u2013P82 (2009).","journal-title":"JPO J. Prosth. Orthot."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-34337-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-34337-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-34337-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T10:12:56Z","timestamp":1769767976000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-34337-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,6]]},"references-count":45,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["34337"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-34337-0","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-6938186\/v1","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,6]]},"assertion":[{"value":"20 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"All participants provided written informed consent after receiving full information about the study\u2019s purpose, procedures, potential risks, and their right to withdraw at any time. All methods were carried out in accordance with relevant guidelines and regulations. Ethical approval was obtained from the Imperial College Research Ethics Committee (ICREC; references: 18IC4685, 22IC7602).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}}],"article-number":"4254"}}