{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T17:17:02Z","timestamp":1793380622560,"version":"4.5.0"},"reference-count":72,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,2,16]],"date-time":"2025-02-16T00:00:00Z","timestamp":1739664000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,2,16]],"date-time":"2025-02-16T00:00:00Z","timestamp":1739664000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001773","name":"University of New South Wales","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001773","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000925","name":"National Health and Medical Research Council","doi-asserted-by":"publisher","award":["1186915"],"award-info":[{"award-number":["1186915"]}],"id":[{"id":"10.13039\/501100000925","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Glaucoma is characterised by progressive vision loss due to retinal ganglion cell deterioration, leading to gradual visual field (VF) impairment. The standard VF test may be impractical in some cases, where optical coherence tomography (OCT) can offer predictive insights into VF for multimodal diagnoses. However, predicting VF measures from OCT data remains challenging. To address this, five regression models were developed to predict VF measures from OCT, Shapley Additive exPlanations (SHAP) analysis was performed for interpretability, and a clinical software tool called OCT to VF Predictor was developed. To evaluate the models, a total of 268 glaucomatous eyes (86 early, 72 moderate, 110 advanced) and 226 normal eyes were included. The machine learning models outperformed recent OCT-based VF prediction deep learning studies, with correlation coefficients of 0.76, 0.80 and 0.76 for mean deviation, visual field index and pattern standard deviation, respectively. Introducing the pointwise normalisation and step-size concept, a mean absolute error of 2.51\u00a0dB was obtained in pointwise sensitivity prediction, and the grayscale prediction model yielded a mean structural similarity index of 77%. The SHAP-based analysis provided critical insights into the most relevant features for glaucoma diagnosis, showing promise in assisting eye care practitioners through an explainable AI tool.<\/jats:p>","DOI":"10.1038\/s41598-025-89557-1","type":"journal-article","created":{"date-parts":[[2025,2,16]],"date-time":"2025-02-16T16:44:06Z","timestamp":1739724246000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Predicting visual field global and local parameters from OCT measurements using explainable machine learning"],"prefix":"10.1038","volume":"15","author":[{"given":"Md Mahmudul","family":"Hasan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jack","family":"Phu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Henrietta","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arcot","family":"Sowmya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Meijering","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Kalloniatis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,2,16]]},"reference":[{"key":"89557_CR1","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1136\/bjo.2005.081224","volume":"90","author":"HA Quigley","year":"2006","unstructured":"Quigley, H. A. & Broman, A. T. The number of people with glaucoma worldwide in 2010 and 2020. Br. J. Ophthalmol. 90, 262 (2006).","journal-title":"Br. J. Ophthalmol."},{"key":"89557_CR2","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1097\/00055735-200304000-00009","volume":"14","author":"U Altangerel","year":"2003","unstructured":"Altangerel, U., Spaeth, G. L. & Rhee, D. J. Visual function, disability, and psychological impact of glaucoma. Curr. Opin. Ophthalmol. 14, 100\u2013105 (2003).","journal-title":"Curr. Opin. Ophthalmol."},{"key":"89557_CR3","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1111\/cxo.12551","volume":"100","author":"J Phu","year":"2017","unstructured":"Phu, J. et al. The value of visual field testing in the era of advanced imaging: Clinical and psychophysical perspectives. Clin. Exp. Optom. 100, 313\u2013332 (2017).","journal-title":"Clin. Exp. Optom."},{"key":"89557_CR4","doi-asserted-by":"publisher","first-page":"1405","DOI":"10.1016\/j.ophtha.2021.03.014","volume":"128","author":"J Phu","year":"2021","unstructured":"Phu, J. & Kalloniatis, M. Comparison of 10\u20132 and 24-2C test grids for identifying central visual field defects in glaucoma and suspect patients. Ophthalmology 128, 1405\u20131416 (2021).","journal-title":"Ophthalmology"},{"key":"89557_CR5","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.ajo.2019.08.013","volume":"208","author":"J Phu","year":"2019","unstructured":"Phu, J., Khuu, S. K., Agar, A. & Kalloniatis, M. Clinical evaluation of Swedish interactive thresholding algorithm\u2013faster compared with Swedish interactive thresholding algorithm\u2013standard in normal subjects, glaucoma suspects, and patients with glaucoma. Am. J. Ophthalmol. 208, 251\u2013264 (2019).","journal-title":"Am. J. Ophthalmol."},{"key":"89557_CR6","doi-asserted-by":"publisher","first-page":"3152","DOI":"10.1167\/iovs.04-0227","volume":"45","author":"RS Harwerth","year":"2004","unstructured":"Harwerth, R. S. et al. Neural losses correlated with visual losses in clinical perimetry. Investig. Ophthalmol. Vis. Sci. 45, 3152\u20133160 (2004).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"89557_CR7","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1097\/IJG.0b013e31822af27a","volume":"21","author":"MT Leite","year":"2012","unstructured":"Leite, M. T. et al. Structure-function relationships using the Cirrus spectral domain optical coherence tomograph and standard automated perimetry. J. Glaucoma 21, 49 (2012).","journal-title":"J. Glaucoma"},{"key":"89557_CR8","doi-asserted-by":"publisher","first-page":"1711","DOI":"10.1016\/S0140-6736(04)16257-0","volume":"363","author":"RN Weinreb","year":"2004","unstructured":"Weinreb, R. N. & Khaw, P. T. Primary open-angle glaucoma. The Lancet 363, 1711\u20131720 (2004).","journal-title":"The Lancet"},{"key":"89557_CR9","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1038\/eye.2011.277","volume":"26","author":"H Rao","year":"2012","unstructured":"Rao, H., Babu, J., Addepalli, U., Senthil, S. & Garudadri, C. Retinal nerve fiber layer and macular inner retina measurements by spectral domain optical coherence tomograph in Indian eyes with early glaucoma. Eye 26, 133\u2013139 (2012).","journal-title":"Eye"},{"key":"89557_CR10","doi-asserted-by":"publisher","first-page":"P71","DOI":"10.1016\/j.ophtha.2020.10.022","volume":"128","author":"SJ Gedde","year":"2021","unstructured":"Gedde, S. J. et al. Primary open-angle glaucoma preferred practice pattern\u00ae. Ophthalmology 128, P71\u2013P150 (2021).","journal-title":"Ophthalmology"},{"key":"89557_CR11","doi-asserted-by":"publisher","first-page":"3975","DOI":"10.1167\/iovs.17-21832","volume":"58","author":"Z Guo","year":"2017","unstructured":"Guo, Z. et al. Optical coherence tomography analysis based prediction of Humphrey 24-2 visual field thresholds in patients with glaucoma. Investig. Ophthalmol. Vis. Sci. 58, 3975\u20133985 (2017).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"89557_CR12","first-page":"35","volume-title":"Seminars in Ophthalmology","author":"N Mendieta","year":"2023","unstructured":"Mendieta, N. et al. How do patients feel about visual field testing? Analysis of subjective perception of standard automated perimetry.\u00a0Seminars in Ophthalmology\u00a036, 35\u201340 (Taylor & Francis, 2023)."},{"key":"89557_CR13","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.parkreldis.2007.07.018","volume":"14","author":"O Yenice","year":"2008","unstructured":"Yenice, O. et al. Visual field analysis in patients with Parkinson\u2019s disease. Parkinson. Relat. Disord. 14, 193\u2013198 (2008).","journal-title":"Parkinson. Relat. Disord."},{"key":"89557_CR14","doi-asserted-by":"publisher","first-page":"1133","DOI":"10.1016\/j.neurobiolaging.2012.08.007","volume":"34","author":"SL Risacher","year":"2013","unstructured":"Risacher, S. L. et al. Visual contrast sensitivity in Alzheimer\u2019s disease, mild cognitive impairment, and older adults with cognitive complaints. Neurobiol. Aging 34, 1133\u20131144 (2013).","journal-title":"Neurobiol. Aging"},{"key":"89557_CR15","volume-title":"Alertness and Variability in the Visual Field Test","author":"DA Saied","year":"2005","unstructured":"Saied, D. A. Alertness and Variability in the Visual Field Test (The University of Manchester, 2005)."},{"key":"89557_CR16","doi-asserted-by":"publisher","first-page":"1359","DOI":"10.1016\/j.ophtha.2014.01.020","volume":"121","author":"SK Gardiner","year":"2014","unstructured":"Gardiner, S. K., Swanson, W. H., Goren, D., Mansberger, S. L. & Demirel, S. Assessment of the reliability of standard automated perimetry in regions of glaucomatous damage. Ophthalmology 121, 1359\u20131369 (2014).","journal-title":"Ophthalmology"},{"key":"89557_CR17","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1016\/0002-9394(89)90006-8","volume":"108","author":"A Heijl","year":"1989","unstructured":"Heijl, A., Lindgren, A. & Lindgren, G. Test-retest variability in glaucomatous visual fields. Am. J. Ophthalmol. 108, 130\u2013135 (1989).","journal-title":"Am. J. Ophthalmol."},{"key":"89557_CR18","first-page":"1083","volume":"30","author":"E Werner","year":"1989","unstructured":"Werner, E., Petrig, B., Krupin, T. & Bishop, K. Variability of automated visual fields in clinically stable glaucoma patients. Investig. Ophthalmol. Vis. Sci. 30, 1083\u20131089 (1989).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"89557_CR19","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1016\/j.preteyeres.2006.03.001","volume":"25","author":"RA Costa","year":"2006","unstructured":"Costa, R. A. et al. Retinal assessment using optical coherence tomography. Progress Retin. Eye Res. 25, 325\u2013353 (2006).","journal-title":"Progress Retin. Eye Res."},{"key":"89557_CR20","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1016\/j.jcin.2009.06.019","volume":"2","author":"HG Bezerra","year":"2009","unstructured":"Bezerra, H. G., Costa, M. A., Guagliumi, G., Rollins, A. M. & Simon, D. I. Intracoronary optical coherence tomography: A comprehensive review: Clinical and research applications. JACC Cardiovasc. Interv. 2, 1035\u20131046 (2009).","journal-title":"JACC Cardiovasc. Interv."},{"key":"89557_CR21","doi-asserted-by":"publisher","first-page":"2214","DOI":"10.1038\/s41598-020-79494-6","volume":"11","author":"S Asano","year":"2021","unstructured":"Asano, S. et al. Predicting the central 10 degrees visual field in glaucoma by applying a deep learning algorithm to optical coherence tomography images. Sci. Rep. 11, 2214 (2021).","journal-title":"Sci. Rep."},{"key":"89557_CR22","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1167\/tvst.12.11.5","volume":"12","author":"V Mohammadzadeh","year":"2023","unstructured":"Mohammadzadeh, V. et al. Prediction of central visual field measures from macular OCT volume scans with deep learning. Transl. Vis. Sci. Technol. 12, 5\u20135 (2023).","journal-title":"Transl. Vis. Sci. Technol."},{"key":"89557_CR23","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1016\/j.ophtha.2019.09.036","volume":"127","author":"M Christopher","year":"2020","unstructured":"Christopher, M. et al. Deep learning approaches predict glaucomatous visual field damage from OCT optic nerve head en face images and retinal nerve fiber layer thickness maps. Ophthalmology 127, 346\u2013356 (2020).","journal-title":"Ophthalmology"},{"key":"89557_CR24","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1167\/tvst.11.8.22","volume":"11","author":"R Hemelings","year":"2022","unstructured":"Hemelings, R. et al. Pointwise visual field estimation from optical coherence tomography in glaucoma using deep learning. Transl. Vis. Sci. Technol. 11, 8\u201322 (2022).","journal-title":"Transl. Vis. Sci. Technol."},{"key":"89557_CR25","doi-asserted-by":"publisher","first-page":"5657","DOI":"10.1167\/iovs.10-5239","volume":"51","author":"H Zhu","year":"2010","unstructured":"Zhu, H. et al. Predicting visual function from the measurements of retinal nerve fiber layer structure. Investig. Ophthalmol. Vis. Sci. 51, 5657\u20135666 (2010).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"89557_CR26","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.ajo.2021.12.020","volume":"238","author":"G Lazaridis","year":"2022","unstructured":"Lazaridis, G. et al. Predicting visual fields from optical coherence tomography via an ensemble of deep representation learners. Am. J. Ophthalmol. 238, 52\u201365 (2022).","journal-title":"Am. J. Ophthalmol."},{"key":"89557_CR27","doi-asserted-by":"publisher","first-page":"21041","DOI":"10.1038\/s41598-022-25660-x","volume":"12","author":"S Moon","year":"2022","unstructured":"Moon, S., Lee, J. H., Choi, H., Lee, S. Y. & Lee, J. Deep learning approaches to predict 10\u20132 visual field from wide-field swept-source optical coherence tomography en face images in glaucoma. Sci. Rep. 12, 21041 (2022).","journal-title":"Sci. Rep."},{"key":"89557_CR28","volume-title":"Deep Learning","author":"I Goodfellow","year":"2016","unstructured":"Goodfellow, I., Bengio, Y. & Courville, A. Deep Learning (MIT Press, 2016)."},{"key":"89557_CR29","first-page":"13","volume-title":"Trustworthy AI Lecture Notes in Artificial Intelligence","author":"R Chatila","year":"2021","unstructured":"Chatila, R. et al. Trustworthy AI Lecture Notes in Artificial Intelligence 13\u201339 (Springer, 2021)."},{"key":"89557_CR30","doi-asserted-by":"publisher","first-page":"1607","DOI":"10.1007\/s13347-021-00477-0","volume":"34","author":"WJ von Eschenbach","year":"2021","unstructured":"von Eschenbach, W. J. Transparency and the black box problem: Why we do not trust AI. Philos. Technol. 34, 1607\u20131622 (2021).","journal-title":"Philos. Technol."},{"key":"89557_CR31","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1167\/tvst.10.13.28","volume":"10","author":"Y Hashimoto","year":"2021","unstructured":"Hashimoto, Y. et al. Predicting 10\u20132 visual field from optical coherence tomography in glaucoma using deep learning corrected with 24\u20132\/30\u20132 visual field. Transl. Vis. Sci. Technol. 10, 13\u201328 (2021).","journal-title":"Transl. Vis. Sci. Technol."},{"key":"89557_CR32","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1111\/cxo.12923","volume":"103","author":"J Phu","year":"2020","unstructured":"Phu, J., Hennessy, M. P., Spargo, M., Dance, S. & Kalloniatis, M. A collaborative care pathway for patients with suspected angle closure glaucoma spectrum disease. Clin. Exp. Optom. 103, 212\u2013219 (2020).","journal-title":"Clin. Exp. Optom."},{"key":"89557_CR33","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1080\/08164622.2021.1878821","volume":"104","author":"H Wang","year":"2021","unstructured":"Wang, H. & Kalloniatis, M. Clinical outcomes of the Centre for Eye Health: An intra-professional optometry-led collaborative eye care clinic in Australia. Clin. Exp. Optom. 104, 795\u2013804 (2021).","journal-title":"Clin. Exp. Optom."},{"key":"89557_CR34","doi-asserted-by":"publisher","first-page":"948","DOI":"10.1111\/opo.12997","volume":"42","author":"J Tong","year":"2022","unstructured":"Tong, J., Alonso-Caneiro, D., Kalloniatis, M. & Zangerl, B. Prediction of visual field defects from macular optical coherence tomography in glaucoma using cluster analysis. Ophthal. Physiol. Opt. 42, 948\u2013964 (2022).","journal-title":"Ophthal. Physiol. Opt."},{"key":"89557_CR35","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1111\/opo.13065","volume":"43","author":"J Tong","year":"2023","unstructured":"Tong, J., Phu, J., Alonso-Caneiro, D., Khuu, S. K. & Kalloniatis, M. High sampling resolution optical coherence tomography reveals potential concurrent reductions in ganglion cell-inner plexiform and inner nuclear layer thickness but not in outer retinal thickness in glaucoma. Ophthal. Physiol. Opt. 43, 46\u201363 (2023).","journal-title":"Ophthal. Physiol. Opt."},{"key":"89557_CR36","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/j.ajo.2020.06.024","volume":"219","author":"J Phu","year":"2020","unstructured":"Phu, J. & Kalloniatis, M. Ability of 24-2C and 24-2 grids to identify central visual field defects and structure-function concordance in glaucoma and suspects. Am. J. Ophthalmol. 219, 317\u2013331 (2020).","journal-title":"Am. J. Ophthalmol."},{"key":"89557_CR37","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.ajo.2005.07.044","volume":"141","author":"RP Mills","year":"2006","unstructured":"Mills, R. P. et al. Categorizing the stage of glaucoma from pre-diagnosis to end-stage disease. Am. J. Ophthalmol. 141, 24\u201330 (2006).","journal-title":"Am. J. Ophthalmol."},{"key":"89557_CR38","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1111\/ceo.12270","volume":"42","author":"A White","year":"2014","unstructured":"White, A. et al. Guidelines for the collaborative care of glaucoma patients and suspects by ophthalmologists and optometrists in Australia. Clin. Exp. Ophthalmol. 42, 107\u2013117 (2014).","journal-title":"Clin. Exp. Ophthalmol."},{"key":"89557_CR39","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1016\/j.ogla.2020.04.009","volume":"3","author":"J Phu","year":"2020","unstructured":"Phu, J. et al. Visualizing the consistency of clinical characteristics that distinguish healthy persons, glaucoma suspect patients, and manifest glaucoma patients. Ophthalmol. Glaucoma 3, 274\u2013287 (2020).","journal-title":"Ophthalmol. Glaucoma"},{"key":"89557_CR40","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1002\/sim.4067","volume":"30","author":"IR White","year":"2011","unstructured":"White, I. R., Royston, P. & Wood, A. M. Multiple imputation using chained equations: Issues and guidance for practice. Stat. Med. 30, 377\u2013399 (2011).","journal-title":"Stat. Med."},{"key":"89557_CR41","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1080\/08164622.2023.2288183","volume":"107","author":"J Phu","year":"2023","unstructured":"Phu, J., Rafla, D. & Kalloniatis, M. Which glaucoma patients benefit from 10\u20132 visual field testing? Proposing the functional vulnerability zone framework. Clin. Exp. Optom. 107, 171\u2013183 (2023).","journal-title":"Clin. Exp. Optom."},{"key":"89557_CR42","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1109\/TITS.2018.2814207","volume":"20","author":"H M\u00e5rtensson","year":"2018","unstructured":"M\u00e5rtensson, H., Keelan, O. & Ahlstr\u00f6m, C. Driver sleepiness classification based on physiological data and driving performance from real road driving. IEEE Trans. Intell. Transp. Syst. 20, 421\u2013430 (2018).","journal-title":"IEEE Trans. Intell. Transp. Syst."},{"key":"89557_CR43","doi-asserted-by":"publisher","first-page":"3316","DOI":"10.1109\/TITS.2020.2981941","volume":"22","author":"A Persson","year":"2020","unstructured":"Persson, A., Jonasson, H., Fredriksson, I., Wiklund, U. & Ahlstr\u00f6m, C. Heart rate variability for classification of alert versus sleep deprived drivers in real road driving conditions. IEEE Trans. Intell. Transp. Syst. 22, 3316\u20133325 (2020).","journal-title":"IEEE Trans. Intell. Transp. Syst."},{"key":"89557_CR44","volume-title":"Python Machine Learning","author":"S Raschka","year":"2015","unstructured":"Raschka, S. Python Machine Learning (Packt Publishing Ltd, 2015)."},{"key":"89557_CR45","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1613\/jair.953","volume":"16","author":"NV Chawla","year":"2002","unstructured":"Chawla, N. V., Bowyer, K. W., Hall, L. O. & Kegelmeyer, W. P. SMOTE: Synthetic minority over-sampling technique. J. Artif. Intell. Res. 16, 321\u2013357 (2002).","journal-title":"J. Artif. Intell. Res."},{"key":"89557_CR46","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4842-4470-8_7","volume-title":"Google Colaboratory","author":"E Bisong","year":"2019","unstructured":"Bisong, E. & Bisong, E. Google Colaboratory (Apress, 2019)."},{"key":"89557_CR47","doi-asserted-by":"publisher","first-page":"6086","DOI":"10.1038\/s41598-024-56706-x","volume":"14","author":"O Rainio","year":"2024","unstructured":"Rainio, O., Teuho, J. & Kl\u00e9n, R. Evaluation metrics and statistical tests for machine learning. Sci. Rep. 14, 6086 (2024).","journal-title":"Sci. Rep."},{"key":"89557_CR48","first-page":"2395","volume":"8","author":"AV Tatachar","year":"2021","unstructured":"Tatachar, A. V. Comparative assessment of regression models based on model evaluation metrics. Int. Res. J. Eng. Technol. (IRJET) 8, 2395\u20132456 (2021).","journal-title":"Int. Res. J. Eng. Technol. (IRJET)"},{"key":"89557_CR49","first-page":"399","volume":"29","author":"MA-S Nasr","year":"2017","unstructured":"Nasr, M.A.-S., AlRahmawy, M. F. & Tolba, A. Multi-scale structural similarity index for motion detection. J. King Saud Univ. Comput. Inf. Sci. 29, 399\u2013409 (2017).","journal-title":"J. King Saud Univ. Comput. Inf. Sci."},{"key":"89557_CR50","first-page":"542","volume":"1","author":"D Berrar","year":"2019","unstructured":"Berrar, D. Cross-validation. Encycl. Bioinform. Comput. Biol. 1, 542\u2013545 (2019).","journal-title":"Encycl. Bioinform. Comput. Biol."},{"key":"89557_CR51","unstructured":"Danjuma, K. J. Performance evaluation of machine learning algorithms in post-operative life expectancy in the lung cancer patients. arXiv:1504.04646 (2015)."},{"key":"89557_CR52","first-page":"1","volume":"30","author":"SM Lundberg","year":"2017","unstructured":"Lundberg, S. M. & Lee, S.-I. A unified approach to interpreting model predictions. Adv. Neural Inf. Process. Syst. 30, 1\u201310 (2017).","journal-title":"Adv. Neural Inf. Process. Syst."},{"key":"89557_CR53","unstructured":"Das, A. & Rad, P. Opportunities and challenges in explainable artificial intelligence (XAI): A survey. arXiv:2006.11371, 1\u201324 (2020)."},{"key":"89557_CR54","volume-title":"Interpretable Machine Learning: A Guide for Making Black Box Models Explainable","author":"C Molnar","year":"2022","unstructured":"Molnar, C. Interpretable Machine Learning: A Guide for Making Black Box Models Explainable 2nd edn. (Leanpub, 2022).","edition":"2"},{"key":"89557_CR55","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1016\/j.ogla.2020.12.001","volume":"4","author":"EY Choi","year":"2021","unstructured":"Choi, E. Y. et al. Predicting global test\u2013retest variability of visual fields in glaucoma. Ophthalmol. Glaucoma 4, 390\u2013399 (2021).","journal-title":"Ophthalmol. Glaucoma"},{"key":"89557_CR56","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1167\/iovs.17-22390","volume":"59","author":"M Wall","year":"2018","unstructured":"Wall, M., Zamba, G. K. & Artes, P. H. The effective dynamic ranges for glaucomatous visual field progression with standard automated perimetry and stimulus sizes III and V. Investig. Ophthalmol. Vis. Sci. 59, 439\u2013445 (2018).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"89557_CR57","doi-asserted-by":"crossref","first-page":"4874876","DOI":"10.1155\/2020\/4874876","volume":"2020","author":"W Geng","year":"2020","unstructured":"Geng, W., Wang, D. & Han, J. Trends in the retinal nerve fiber layer thickness changes with different degrees of visual field defects. J. Ophthalmol. 2020, 4874876 (2020).","journal-title":"J. Ophthalmol."},{"key":"89557_CR58","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1016\/j.ophtha.2023.12.018","volume":"131","author":"JC Tan","year":"2023","unstructured":"Tan, J. C., Agar, A., Kalloniatis, M. & Phu, J. Quantification and predictors of visual field variability in healthy, suspect and glaucomatous eyes using SITA-Faster. Ophthalmology 131, 658\u2013666 (2023).","journal-title":"Ophthalmology"},{"key":"89557_CR59","doi-asserted-by":"publisher","first-page":"1222","DOI":"10.1016\/j.ophtha.2020.12.027","volume":"128","author":"D WuDunn","year":"2021","unstructured":"WuDunn, D. et al. OCT angiography for the diagnosis of glaucoma: A report by the American Academy of Ophthalmology. Ophthalmology 128, 1222\u20131235 (2021).","journal-title":"Ophthalmology"},{"key":"89557_CR60","doi-asserted-by":"publisher","first-page":"18304","DOI":"10.1038\/s41598-023-43104-y","volume":"13","author":"D Kim","year":"2023","unstructured":"Kim, D., Seo, S. B., Park, S. J. & Cho, H.-K. Deep learning visual field global index prediction with optical coherence tomography parameters in glaucoma patients. Sci. Rep. 13, 18304 (2023).","journal-title":"Sci. Rep."},{"key":"89557_CR61","doi-asserted-by":"publisher","first-page":"3523","DOI":"10.1038\/s41433-023-02547-3","volume":"37","author":"A Sethi","year":"2023","unstructured":"Sethi, A., Rashidisabet, H., Hallak, J. A. & Vajaranant, T. S. Which OCT parameters can best predict visual field progression in glaucoma?. Eye 37, 3523\u20133525 (2023).","journal-title":"Eye"},{"key":"89557_CR62","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/diagnostics11091718","volume":"11","author":"CW Wu","year":"2021","unstructured":"Wu, C. W., Shen, H. L., Lu, C. J., Chen, S. H. & Chen, H. Y. Comparison of different machine learning classifiers for glaucoma diagnosis based on spectralis OCT. Diagnostics 11, 1\u201314 (2021).","journal-title":"Diagnostics"},{"key":"89557_CR63","first-page":"1","volume":"130\u2013146","author":"MM Hasan","year":"2024","unstructured":"Hasan, M. M., Phu, J., Sowmya, A., Meijering, E. & Kalloniatis, M. Artificial intelligence in the diagnosis of glaucoma and neurodegenerative diseases. Clin. Exp. Optom. 130\u2013146, 1\u201315 (2024).","journal-title":"Clin. Exp. Optom."},{"key":"89557_CR64","doi-asserted-by":"publisher","first-page":"1189","DOI":"10.1214\/aos\/1013203451","volume":"29","author":"JH Friedman","year":"2001","unstructured":"Friedman, J. H. Greedy function approximation: A gradient boosting machine. Ann. Stat. 29, 1189\u20131232 (2001).","journal-title":"Ann. Stat."},{"key":"89557_CR65","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2014\/931738","volume":"2014","author":"JW Han","year":"2014","unstructured":"Han, J. W., Cho, S. Y. & Kang, K. D. Correlation between optic nerve parameters obtained using 3D nonmydriatic retinal camera and optical coherence tomography: Interobserver agreement on the disc damage likelihood scale. J. Ophthalmol. 2014, 1\u20139 (2014).","journal-title":"J. Ophthalmol."},{"key":"89557_CR66","doi-asserted-by":"publisher","first-page":"e763","DOI":"10.1097\/IJG.0000000000000496","volume":"25","author":"SW Hong","year":"2016","unstructured":"Hong, S. W., Lee, S. B., Jee, D.-H. & Ahn, M. D. Evaluation of interocular retinal nerve fiber layer thickness symmetry as a diagnostic modality for glaucoma. J. Glaucoma 25, e763\u2013e771 (2016).","journal-title":"J. Glaucoma"},{"key":"89557_CR67","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.ophtha.2022.07.025","volume":"130","author":"C Bradley","year":"2023","unstructured":"Bradley, C. et al. Evidence-based guidelines for the number of peripapillary OCT scans needed to detect glaucoma worsening. Ophthalmology 130, 39\u201347 (2023).","journal-title":"Ophthalmology"},{"key":"89557_CR68","unstructured":"Lee, G. & Flanagan, J. G. Machine learning methods for creating structure-derived visual field priors. US patent 2022\/0400943 A1 (2022)."},{"key":"89557_CR69","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.ajo.2020.07.047","volume":"221","author":"J Phu","year":"2021","unstructured":"Phu, J. & Kalloniatis, M. A strategy for seeding point error assessment for retesting (SPEAR) in perimetry applied to normal subjects, glaucoma suspects, and patients with glaucoma. Am. J. Ophthalmol. 221, 115\u2013130 (2021).","journal-title":"Am. J. Ophthalmol."},{"key":"89557_CR70","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.ajo.2021.04.019","volume":"230","author":"J Phu","year":"2021","unstructured":"Phu, J. & Kalloniatis, M. Viability of performing multiple 24-2 visual field examinations at the same clinical visit: The Frontloading Fields Study (FFS). Am. J. Ophthalmol. 230, 48\u201359 (2021).","journal-title":"Am. J. Ophthalmol."},{"key":"89557_CR71","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1167\/tvst.11.1.37","volume":"11","author":"J Phu","year":"2022","unstructured":"Phu, J., Masselos, K., Sullivan-Mee, M. & Kalloniatis, M. Glaucoma suspects: the impact of risk factor-driven review periods on clinical load, diagnoses, and healthcare costs. Transl. Vis. Sci. Technol. 11, 37\u201337 (2022).","journal-title":"Transl. Vis. Sci. Technol."},{"key":"89557_CR72","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1201\/9781003424987-1","volume-title":"Machine Learning and IoT Applications for Health Informatics","author":"B Ta\u015fci","year":"2024","unstructured":"Ta\u015fci, B. Machine Learning and IoT Applications for Health Informatics 1\u201317 (CRC Press, 2024)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-89557-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-89557-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-89557-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,16]],"date-time":"2025-02-16T16:44:15Z","timestamp":1739724255000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-89557-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,16]]},"references-count":72,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["89557"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-89557-1","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,16]]},"assertion":[{"value":"3 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 February 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Commercial relationship disclosure: M.M.H., J.P., H.W., A.S., E.M., M.K. have submitted a patent application (#2024900616) in the name of \u201cNewSouth Innovations Pty Limited\u201d and \u201cDeakin University\u201d which is currently pending. They declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"5685"}}