{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T01:59:33Z","timestamp":1784080773026,"version":"3.55.0"},"reference-count":61,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,17]],"date-time":"2025-03-17T00:00:00Z","timestamp":1742169600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,17]],"date-time":"2025-03-17T00:00:00Z","timestamp":1742169600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100018935","name":"Universit\u00e4tsklinikum Erlangen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100018935","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Distortions in brain MRI caused by gradient nonlinearities may reach several millimeters, thus distortion correction is strongly recommended for radiotherapy treatment planning. However, the significance of MRI distortion correction on actual clinical outcomes has not been described yet. Therefore, we investigated the impact of planning MRI distortion correction on subsequent local control in a historic series of 419 brain metastases in 189 patients treated with stereotactic radiotherapy between 01\/2003 and 04\/2015. Local control was evaluated using a volumetric extension of the RANO-BM criteria. The predictive significance of distortion correction was assessed using competing risk analysis. In this cohort, 2D distortion-corrected MRIs had been used for treatment planning in 52.5% (220\/419) of lesions, while uncorrected MRIs had been employed in 47.5% (199\/419) of metastases. 2D distortion correction was associated with improved local control (Cumulative incidence of local progression at 12\u00a0months: 14.3% vs. 21.2% and at 24\u00a0months: 18.7% vs. 28.6%, p\u2009=\u20090.038). In multivariate analysis, adjusting for histology, baseline tumor volume, interval between MRI and treatment delivery, year of planning MRI, biologically effective dose and adjuvant Whole-brain radiotherapy, use of distortion correction remained significantly associated with improved local control (HR 0.55, p\u2009=\u20090.020). This is the first study to clinically evaluate the impact of MRI gradient nonlinearity distortion correction on local control in stereotactic radiotherapy for brain metastases. In this historic series, we found significantly higher local control when using 2D corrected vs. uncorrected MRI studies for treatment planning. These results stress the importance of assuring that MR images used for radiotherapy treatment planning are properly distortion-corrected.<\/jats:p>","DOI":"10.1038\/s41598-025-93255-3","type":"journal-article","created":{"date-parts":[[2025,3,17]],"date-time":"2025-03-17T02:07:27Z","timestamp":1742177247000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["MRI distortion correction is associated with improved local control in stereotactic radiotherapy for brain metastases"],"prefix":"10.1038","volume":"15","author":[{"given":"Daniel","family":"H\u00f6fler","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johanna","family":"Grigo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hadi","family":"Siavosch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Saake","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuel Alexander","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Weissmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Schubert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raphaela","family":"Voigt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Lettmaier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sabine","family":"Semrau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arnd","family":"D\u00f6rfler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Uder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Bert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rainer","family":"Fietkau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3966-2872","authenticated-orcid":false,"given":"Florian","family":"Putz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,17]]},"reference":[{"issue":"11","key":"93255_CR1","first-page":"4655","volume":"32","author":"E Tabouret","year":"2012","unstructured":"Tabouret, E. et al. Recent trends in epidemiology of brain metastases: an overview. Anticancer Res. 32(11), 4655\u20134662 (2012).","journal-title":"Anticancer Res."},{"issue":"2","key":"93255_CR2","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1093\/neuonc\/now241","volume":"19","author":"R Soffietti","year":"2017","unstructured":"Soffietti, R. et al. Diagnosis and treatment of brain metastases from solid tumors: guidelines from the European association of neuro-oncology (EANO). Neuro Oncol. 19(2), 162\u2013174 (2017).","journal-title":"Neuro Oncol."},{"key":"93255_CR3","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.ejca.2017.07.017","volume":"84","author":"C Gaudy-Marqueste","year":"2017","unstructured":"Gaudy-Marqueste, C. et al. Survival of melanoma patients treated with targeted therapy and immunotherapy after systematic upfront control of brain metastases by radiosurgery. Eur. J. Cancer 84, 44\u201354 (2017).","journal-title":"Eur. J. Cancer"},{"issue":"2","key":"93255_CR4","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1200\/JCO.2015.62.0138","volume":"34","author":"KL Johung","year":"2016","unstructured":"Johung, K. L. et al. Extended survival and prognostic factors for patients with ALK-rearranged non-small-cell lung cancer and brain metastasis. J. Clin. Oncol. 34(2), 123\u2013129 (2016).","journal-title":"J. Clin. Oncol."},{"issue":"1","key":"93255_CR5","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1007\/s00066-019-01506-w","volume":"196","author":"D Steinmann","year":"2020","unstructured":"Steinmann, D. et al. Quality of life in patients with limited (1\u20133) brain metastases undergoing stereotactic or whole brain radiotherapy: A prospective study of the DEGRO QoL working group. Strahlenther. Onkol. 196(1), 48\u201357 (2020).","journal-title":"Strahlenther. Onkol."},{"issue":"4","key":"93255_CR6","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1001\/jama.2016.9839","volume":"316","author":"PD Brown","year":"2016","unstructured":"Brown, P. D. et al. Effect of radiosurgery alone vs radiosurgery with whole brain radiation therapy on cognitive function in patients with 1 to 3 brain metastases: A randomized clinical trial. JAMA 316(4), 401\u2013409 (2016).","journal-title":"JAMA"},{"issue":"21","key":"93255_CR7","doi-asserted-by":"publisher","first-page":"2483","DOI":"10.1001\/jama.295.21.2483","volume":"295","author":"H Aoyama","year":"2006","unstructured":"Aoyama, H. et al. Stereotactic radiosurgery plus whole-brain radiation therapy vs stereotactic radiosurgery alone for treatment of brain metastases: a randomized controlled trial. JAMA 295(21), 2483\u20132491 (2006).","journal-title":"JAMA"},{"issue":"2","key":"93255_CR8","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1200\/JCO.2010.30.1655","volume":"29","author":"M Kocher","year":"2011","unstructured":"Kocher, M. et al. Adjuvant whole-brain radiotherapy versus observation after radiosurgery or surgical resection of one to three cerebral metastases: results of the EORTC 22952\u201326001 study. J. Clin. Oncol. 29(2), 134\u2013141 (2011).","journal-title":"J. Clin. Oncol."},{"issue":"2","key":"93255_CR9","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.radonc.2016.09.018","volume":"121","author":"ES Paulson","year":"2016","unstructured":"Paulson, E. S. et al. Consensus opinion on MRI simulation for external beam radiation treatment planning. Radiother. Oncol. 121(2), 187\u2013192 (2016).","journal-title":"Radiother. Oncol."},{"issue":"5","key":"93255_CR10","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1007\/s00066-020-01583-2","volume":"196","author":"D Schmitt","year":"2020","unstructured":"Schmitt, D. et al. Technological quality requirements for stereotactic radiotherapy: Expert review group consensus from the DGMP working group for physics and technology in stereotactic radiotherapy. Strahlenther. Onkol. 196(5), 421\u2013443 (2020).","journal-title":"Strahlenther. Onkol."},{"key":"93255_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2019.07.011","author":"E Hessen","year":"2019","unstructured":"Hessen, E. et al. Predicting and implications of target volume changes of brain metastases during fractionated stereotactic radiosurgery. Radiother. Oncol. https:\/\/doi.org\/10.1016\/j.radonc.2019.07.011 (2019).","journal-title":"Radiother. Oncol."},{"key":"93255_CR12","first-page":"23","volume":"2","author":"ED Hessen","year":"2017","unstructured":"Hessen, E. D. et al. Significant tumor shift in patients treated with stereotactic radiosurgery for brain metastasis. Clin. Transl. Radiat. Oncol. 2, 23\u201328 (2017).","journal-title":"Clin. Transl. Radiat. Oncol."},{"issue":"1","key":"93255_CR13","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.ijrobp.2015.05.001","volume":"93","author":"ZA Seymour","year":"2015","unstructured":"Seymour, Z. A. et al. Interval from imaging to treatment delivery in the radiation surgery age: How long is too long?. Int. J. Radiat. Oncol. Biol. Phys. 93(1), 126\u2013132 (2015).","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"4","key":"93255_CR14","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1016\/j.ijrobp.2018.06.021","volume":"102","author":"AL Salkeld","year":"2018","unstructured":"Salkeld, A. L. et al. Changes in brain metastasis during radiosurgical planning. Int. J. Radiat. Oncol. Biol. Phys. 102(4), 727\u2013733 (2018).","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"2","key":"93255_CR15","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1118\/1.2402331","volume":"34","author":"LN Baldwin","year":"2007","unstructured":"Baldwin, L. N. et al. Characterization, prediction, and correction of geometric distortion in 3 T MR images. Med. Phys. 34(2), 388\u2013399 (2007).","journal-title":"Med. Phys."},{"issue":"4","key":"93255_CR16","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1227\/00006123-199410000-00016","volume":"35","author":"TS Sumanaweera","year":"1994","unstructured":"Sumanaweera, T. S. et al. Characterization of spatial distortion in magnetic resonance imaging and its implications for stereotactic surgery. Neurosurgery 35(4), 696\u2013703 (1994).","journal-title":"Neurosurgery"},{"issue":"11","key":"93255_CR17","doi-asserted-by":"publisher","first-page":"2651","DOI":"10.1088\/0031-9155\/50\/11\/014","volume":"50","author":"SA Reinsberg","year":"2005","unstructured":"Reinsberg, S. A. et al. A complete distortion correction for MR images: II. Rectification of static-field inhomogeneities by similarity-based profile mapping. Phys. Med. Biol. 50(11), 2651\u201361 (2005).","journal-title":"Phys. Med. Biol."},{"issue":"9","key":"93255_CR18","doi-asserted-by":"publisher","first-page":"3917","DOI":"10.1118\/1.3180107","volume":"36","author":"LN Baldwin","year":"2009","unstructured":"Baldwin, L. N., Wachowicz, K. & Fallone, B. G. A two-step scheme for distortion rectification of magnetic resonance images. Med. Phys. 36(9), 3917\u20133926 (2009).","journal-title":"Med. Phys."},{"issue":"7","key":"93255_CR19","doi-asserted-by":"publisher","first-page":"1343","DOI":"10.1088\/0031-9155\/50\/7\/001","volume":"50","author":"SJ Doran","year":"2005","unstructured":"Doran, S. J. et al. A complete distortion correction for MR images: I. Gradient warp correction. Phys. Med. Biol. 50(7), 1343\u20131361 (2005).","journal-title":"Phys. Med. Biol."},{"issue":"2","key":"93255_CR20","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1007\/PL00002385","volume":"177","author":"A Fransson","year":"2001","unstructured":"Fransson, A., Andreo, P. & Potter, R. Aspects of MR image distortions in radiotherapy treatment planning. Strahlenther. Onkol. 177(2), 59\u201373 (2001).","journal-title":"Strahlenther. Onkol."},{"issue":"12","key":"93255_CR21","doi-asserted-by":"publisher","first-page":"N253","DOI":"10.1088\/0031-9155\/51\/12\/N04","volume":"51","author":"CP Karger","year":"2006","unstructured":"Karger, C. P. et al. Accuracy of device-specific 2D and 3D image distortion correction algorithms for magnetic resonance imaging of the head provided by a manufacturer. Phys. Med. Biol. 51(12), N253\u2013N261 (2006).","journal-title":"Phys. Med. Biol."},{"issue":"2","key":"93255_CR22","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1016\/j.neuroimage.2005.09.046","volume":"30","author":"J Jovicich","year":"2006","unstructured":"Jovicich, J. et al. Reliability in multi-site structural MRI studies: effects of gradient non-linearity correction on phantom and human data. Neuroimage 30(2), 436\u2013443 (2006).","journal-title":"Neuroimage"},{"issue":"5","key":"93255_CR23","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1016\/j.mri.2016.01.001","volume":"34","author":"T Torfeh","year":"2016","unstructured":"Torfeh, T. et al. Characterization of 3D geometric distortion of magnetic resonance imaging scanners commissioned for radiation therapy planning. Magn. Reson. Imaging 34(5), 645\u2013653 (2016).","journal-title":"Magn. Reson. Imaging"},{"issue":"13","key":"93255_CR24","doi-asserted-by":"publisher","first-page":"3579","DOI":"10.1088\/0031-9155\/53\/13\/013","volume":"53","author":"T Stanescu","year":"2008","unstructured":"Stanescu, T. et al. A study on the magnetic resonance imaging (MRI)-based radiation treatment planning of intracranial lesions. Phys. Med. Biol. 53(13), 3579\u20133593 (2008).","journal-title":"Phys. Med. Biol."},{"issue":"5","key":"93255_CR25","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1007\/s00066-020-01604-0","volume":"196","author":"F Putz","year":"2020","unstructured":"Putz, F. et al. Magnetic resonance imaging for brain stereotactic radiotherapy: A review of requirements and pitfalls. Strahlenther. Onkol. 196(5), 444\u2013456 (2020).","journal-title":"Strahlenther. Onkol."},{"issue":"6","key":"93255_CR26","doi-asserted-by":"publisher","first-page":"e319","DOI":"10.1016\/j.prro.2016.05.008","volume":"6","author":"TM Seibert","year":"2016","unstructured":"Seibert, T. M. et al. Distortion inherent to magnetic resonance imaging can lead to geometric miss in radiosurgery planning. Pract. Radiat. Oncol. 6(6), e319\u2013e328 (2016).","journal-title":"Pract. Radiat. Oncol."},{"issue":"8","key":"93255_CR27","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1007\/s00066-019-01450-9","volume":"195","author":"S Koca","year":"2019","unstructured":"Koca, S. et al. Time course of pain response and toxicity after whole-nerve-encompassing LINAC-based stereotactic radiosurgery for trigeminal neuralgia-a prospective observational study. Strahlenther. Onkol. 195(8), 745\u2013755 (2019).","journal-title":"Strahlenther. Onkol."},{"issue":"3","key":"93255_CR28","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1007\/s00066-016-1086-5","volume":"193","author":"F Putz","year":"2017","unstructured":"Putz, F. et al. Stereotactic radiotherapy of vestibular schwannoma\u202f: Hearing preservation, vestibular function, and local control following primary and salvage radiotherapy. Strahlenther. Onkol. 193(3), 200\u2013212 (2017).","journal-title":"Strahlenther. Onkol."},{"issue":"3","key":"93255_CR29","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1016\/j.radonc.2011.01.011","volume":"98","author":"R Wiggenraad","year":"2011","unstructured":"Wiggenraad, R. et al. Dose-effect relation in stereotactic radiotherapy for brain metastases. A systematic review. Radiother. Oncol. 98(3), 292\u2013297 (2011).","journal-title":"Radiother. Oncol."},{"key":"93255_CR30","doi-asserted-by":"publisher","DOI":"10.1201\/b15450","volume-title":"Basic Clinical Radiobiology","author":"Joiner","year":"2009","unstructured":"Joiner, Quantifying cell kill and survival, in Basic clinical radiobiology. In Basic Clinical Radiobiology (ed. Joiner, M.) (CRC Press, 2009)."},{"issue":"1","key":"93255_CR31","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1002\/mrm.20122","volume":"52","author":"A Janke","year":"2004","unstructured":"Janke, A. et al. Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI images. Magn. Reson. Med. 52(1), 115\u2013122 (2004).","journal-title":"Magn. Reson. Med."},{"key":"93255_CR32","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2020.559193","author":"F Putz","year":"2020","unstructured":"Putz, F. et al. FSRT vs SRS in brain metastases \u2013 Differences in local control and radiation necrosis \u2013 a volumetric study. Front. Oncol. https:\/\/doi.org\/10.3389\/fonc.2020.559193 (2020).","journal-title":"Front. Oncol."},{"issue":"6","key":"93255_CR33","doi-asserted-by":"publisher","first-page":"e270","DOI":"10.1016\/S1470-2045(15)70057-4","volume":"16","author":"NU Lin","year":"2015","unstructured":"Lin, N. U. et al. Response assessment criteria for brain metastases: proposal from the RANO group. Lancet Oncol. 16(6), e270\u2013e278 (2015).","journal-title":"Lancet Oncol."},{"issue":"9","key":"93255_CR34","doi-asserted-by":"publisher","first-page":"1388","DOI":"10.1038\/bmt.2009.359","volume":"45","author":"L Scrucca","year":"2010","unstructured":"Scrucca, L., Santucci, A. & Aversa, F. Regression modeling of competing risk using R: an in depth guide for clinicians. Bone Marrow Transpl. 45(9), 1388\u20131395 (2010).","journal-title":"Bone Marrow Transpl."},{"key":"93255_CR35","doi-asserted-by":"publisher","DOI":"10.1214\/aos\/1176350951","author":"RJ Gray","year":"1988","unstructured":"Gray, R. J. A class of K-sample tests for comparing the cumulative incidence of a competing risk. Ann. Stat. https:\/\/doi.org\/10.1214\/aos\/1176350951 (1988).","journal-title":"Ann. Stat."},{"issue":"446","key":"93255_CR36","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1080\/01621459.1999.10474144","volume":"94","author":"JP Fine","year":"1999","unstructured":"Fine, J. P. & Gray, R. J. A proportional hazards model for the subdistribution of a competing risk. J. Am. Stat. Assoc. 94(446), 496\u2013509 (1999).","journal-title":"J. Am. Stat. Assoc."},{"issue":"8","key":"93255_CR37","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1007\/s00066-019-01475-0","volume":"195","author":"V Nardone","year":"2019","unstructured":"Nardone, V. et al. Role of perilesional edema and tumor volume in the prognosis of non-small cell lung cancer (NSCLC) undergoing radiosurgery (SRS) for brain metastases. Strahlenther. Onkol. 195(8), 734\u2013744 (2019).","journal-title":"Strahlenther. Onkol."},{"issue":"3","key":"93255_CR38","first-page":"656","volume":"51","author":"PD Brown","year":"2002","unstructured":"Brown, P. D. et al. Stereotactic radiosurgery for patients with \u201cradioresistant\u201d brain metastases. Neurosurgery 51(3), 656\u201365 (2002).","journal-title":"Neurosurgery"},{"issue":"282","key":"93255_CR39","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1080\/01621459.1958.10501452","volume":"53","author":"EL Kaplan","year":"1958","unstructured":"Kaplan, E. L. & Meier, P. Nonparametric estimation from incomplete observations. J. Am. Stat. Assoc. 53(282), 457\u2013481 (1958).","journal-title":"J. Am. Stat. Assoc."},{"issue":"3","key":"93255_CR40","first-page":"163","volume":"50","author":"N Mantel","year":"1966","unstructured":"Mantel, N. Evaluation of survival data and two new rank order statistics arising in its consideration. Cancer Chemother. Rep. 50(3), 163\u2013170 (1966).","journal-title":"Cancer Chemother. Rep."},{"issue":"2","key":"93255_CR41","doi-asserted-by":"publisher","first-page":"185","DOI":"10.2307\/2344317","volume":"135","author":"R Peto","year":"1972","unstructured":"Peto, R. & Peto, J. Asymptotically efficient rank invariant test procedures. J. Royal Stat. Soc. Ser. A (Gen.) 135(2), 185\u2013207 (1972).","journal-title":"J. Royal Stat. Soc. Ser. A (Gen.)"},{"issue":"17","key":"93255_CR42","doi-asserted-by":"publisher","first-page":"4952","DOI":"10.1002\/hbm.24750","volume":"40","author":"F Isensee","year":"2019","unstructured":"Isensee, F. et al. Automated brain extraction of multisequence MRI using artificial neural networks. Hum. Brain Mapp. 40(17), 4952\u20134964 (2019).","journal-title":"Hum. Brain Mapp."},{"issue":"9","key":"93255_CR43","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","volume":"30","author":"A Fedorov","year":"2012","unstructured":"Fedorov, A. et al. 3D Slicer as an image computing platform for the quantitative imaging network. Magn. Reson. Imaging 30(9), 1323\u20131341 (2012).","journal-title":"Magn. Reson. Imaging"},{"key":"93255_CR44","volume-title":"The Visualization Toolkit","author":"W Schroeder","year":"2006","unstructured":"Schroeder, W., Martin, K. & Lorensen, B. The Visualization Toolkit 4th edn. (Kitware, 2006).","edition":"4"},{"issue":"1","key":"93255_CR45","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.ijrobp.2020.10.034","volume":"110","author":"KJ Redmond","year":"2021","unstructured":"Redmond, K. J. et al. Tumor control probability of radiosurgery and fractionated stereotactic radiosurgery for brain metastases. Int. J. Radiat. Oncol. Biol. Phys. 110(1), 53\u201367 (2021).","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"2","key":"93255_CR46","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/0167-8140(92)90344-T","volume":"23","author":"R Potter","year":"1992","unstructured":"Potter, R. et al. Sagittal and coronal planes from MRI for treatment planning in tumors of brain, head and neck: MRI assisted simulation. Radiother. Oncol. 23(2), 127\u2013130 (1992).","journal-title":"Radiother. Oncol."},{"issue":"1","key":"93255_CR47","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0167-8140(96)01866-X","volume":"42","author":"VS Khoo","year":"1997","unstructured":"Khoo, V. S. et al. Magnetic resonance imaging (MRI): considerations and applications in radiotherapy treatment planning. Radiother. Oncol. 42(1), 1\u201315 (1997).","journal-title":"Radiother. Oncol."},{"issue":"3","key":"93255_CR48","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1227\/00006123-199203000-00015","volume":"30","author":"D Kondziolka","year":"1992","unstructured":"Kondziolka, D. et al. A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination. Neurosurgery 30(3), 402\u20136 (1992).","journal-title":"Neurosurgery"},{"key":"93255_CR49","doi-asserted-by":"publisher","DOI":"10.1007\/s00066-022-01996-1","author":"T Welzel","year":"2022","unstructured":"Welzel, T. et al. Stereotactic radiotherapy of brain metastases: clinical impact of three-dimensional SPACE imaging for 3T-MRI-based treatment planning. Strahlenther. Onkol. https:\/\/doi.org\/10.1007\/s00066-022-01996-1 (2022).","journal-title":"Strahlenther. Onkol."},{"issue":"7","key":"93255_CR50","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1007\/s00066-021-01776-3","volume":"197","author":"V Meki\u0161","year":"2021","unstructured":"Meki\u0161, V. et al. Comparison of treatment position with mask immobilization and standard diagnostic setup in intracranial MRI radiotherapy simulation. Strahlenther. Onkol. 197(7), 614\u2013621 (2021).","journal-title":"Strahlenther. Onkol."},{"issue":"3","key":"93255_CR51","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1007\/s00066-020-01703-y","volume":"197","author":"V Mengling","year":"2021","unstructured":"Mengling, V. et al. Implementation of a dedicated 1.5 T MR scanner for radiotherapy treatment planning featuring a novel high-channel coil setup for brain imaging in treatment position. Strahlenther. Onkol. 197(3), 246\u2013256 (2021).","journal-title":"Strahlenther. Onkol."},{"issue":"7","key":"93255_CR52","doi-asserted-by":"publisher","first-page":"e636","DOI":"10.1002\/mp.14695","volume":"48","author":"CK Glide-Hurst","year":"2021","unstructured":"Glide-Hurst, C. K. et al. Task group 284 report: magnetic resonance imaging simulation in radiotherapy: considerations for clinical implementation, optimization, and quality assurance. Med. Phys. 48(7), e636\u2013e670 (2021).","journal-title":"Med. Phys."},{"issue":"10","key":"93255_CR53","doi-asserted-by":"publisher","first-page":"926","DOI":"10.1007\/s00066-022-01996-1","volume":"198","author":"T Welzel","year":"2022","unstructured":"Welzel, T. et al. Stereotactic radiotherapy of brain metastases: clinical impact of three-dimensional SPACE imaging for 3T-MRI-based treatment planning. Strahlenther. Onkol. 198(10), 926\u2013933 (2022).","journal-title":"Strahlenther. Onkol."},{"issue":"8","key":"93255_CR54","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1007\/s00066-023-02090-w","volume":"199","author":"S Masitho","year":"2023","unstructured":"Masitho, S. et al. Synthetic CTs for MRI-only brain RT treatment: integration of immobilization systems. Strahlenther. Onkol. 199(8), 739\u2013748 (2023).","journal-title":"Strahlenther. Onkol."},{"issue":"1","key":"93255_CR55","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1118\/1.4896096","volume":"42","author":"ES Paulson","year":"2015","unstructured":"Paulson, E. S. et al. Comprehensive MRI simulation methodology using a dedicated MRI scanner in radiation oncology for external beam radiation treatment planning. Med. Phys. 42(1), 28\u201339 (2015).","journal-title":"Med. Phys."},{"key":"93255_CR56","doi-asserted-by":"publisher","DOI":"10.1007\/s00066-023-02120-7","author":"S Ohira","year":"2023","unstructured":"Ohira, S. et al. Impact of magnetic resonance imaging-related geometric distortion of dose distribution in fractionated stereotactic radiotherapy in patients with brain metastases. Strahlenther. Onkol. https:\/\/doi.org\/10.1007\/s00066-023-02120-7 (2023).","journal-title":"Strahlenther. Onkol."},{"issue":"1","key":"93255_CR57","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00066-023-02183-6","volume":"200","author":"F Putz","year":"2024","unstructured":"Putz, F. et al. Quality requirements for MRI simulation in cranial stereotactic radiotherapy: a guideline from the German Taskforce \u201cImaging in Stereotactic Radiotherapy\u201d. Strahlenther. Onkol. 200(1), 1\u201318 (2024).","journal-title":"Strahlenther. Onkol."},{"issue":"9422","key":"93255_CR58","doi-asserted-by":"publisher","first-page":"1665","DOI":"10.1016\/S0140-6736(04)16250-8","volume":"363","author":"DW Andrews","year":"2004","unstructured":"Andrews, D. W. et al. Whole brain radiation therapy with or without stereotactic radiosurgery boost for patients with one to three brain metastases: phase III results of the RTOG 9508 randomised trial. Lancet 363(9422), 1665\u20131672 (2004).","journal-title":"Lancet"},{"key":"93255_CR59","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.phro.2020.08.001","volume":"15","author":"V Mengling","year":"2020","unstructured":"Mengling, V. et al. Evaluation of the influence of susceptibility-induced magnetic field distortions on the precision of contouring intracranial organs at risk for stereotactic radiosurgery. Phys. Imaging Radiat. Oncol. 15, 91\u201397 (2020).","journal-title":"Phys. Imaging Radiat. Oncol."},{"issue":"3","key":"93255_CR60","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1088\/0031-9155\/58\/3\/465","volume":"58","author":"H Wang","year":"2013","unstructured":"Wang, H., Balter, J. & Cao, Y. Patient-induced susceptibility effect on geometric distortion of clinical brain MRI for radiation treatment planning on a 3T scanner. Phys. Med. Biol. 58(3), 465\u2013477 (2013).","journal-title":"Phys. Med. Biol."},{"issue":"1","key":"93255_CR61","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1186\/s13014-023-02209-4","volume":"18","author":"D Moore-Palhares","year":"2023","unstructured":"Moore-Palhares, D. et al. Clinical implementation of magnetic resonance imaging simulation for radiation oncology planning: 5 year experience. Radiat. Oncol. 18(1), 27 (2023).","journal-title":"Radiat. Oncol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-93255-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-93255-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-93255-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,17]],"date-time":"2025-03-17T02:43:05Z","timestamp":1742179385000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-93255-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,17]]},"references-count":61,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["93255"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-93255-3","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-4667600\/v1","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,17]]},"assertion":[{"value":"1 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Speaker fees from Siemens Healthineers (unrelated to this work): DH, MS, PS, FP. The other authors declare no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"9077"}}