{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T06:20:17Z","timestamp":1789626017277,"version":"build-2803163510"},"reference-count":74,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,21]],"date-time":"2025-03-21T00:00:00Z","timestamp":1742515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,21]],"date-time":"2025-03-21T00:00:00Z","timestamp":1742515200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Helmholtz-Zentrum Berlin f\u00fcr Materialien und Energie GmbH"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Electron paramagnetic resonance (EPR) is an accurate and efficient technique to probe unpaired electrons in many applications across materials science, chemistry, and biology. Dynamic processes are investigated using EPR; however, these applications are limited by the use of resonator-based spectrometers such that the entire process must be confined to the resonator. The EPR-on-a-chip (EPRoC) device circumvents this limitation by integrating the entire EPR spectrometer into a single microchip. In this approach, the coil of a voltage-controlled oscillator (VCO) is used as the microwave source and detector simultaneously, operating under a protective coating such that the device may be placed in the sample solution directly. Additionally, improvements in sensitivity via rapid scan EPR (RS-EPR\/RS-EPRoC) increase the accessible applications where SNR per measurement time is the fundamental limit. The herein reported device combines a dipstick EPRoC sensor with the enhanced sensitivity of frequency-swept frequency modulated rapid scan to measure triarylmethyl (trityl, Ox071) oxygen-sensitive probes dissolved in aqueous solutions. EPR spectra of Ox071 solutions were recorded using the RS-EPRoC sensor while varying the oxygen concentration of the solution between normal atmosphere and after purging the solution with nitrogen gas. We demonstrate that EPRoC may be employed to monitor dissolved oxygen in fluid solution in an online fashion.<\/jats:p>","DOI":"10.1038\/s41598-025-93591-4","type":"journal-article","created":{"date-parts":[[2025,3,21]],"date-time":"2025-03-21T21:15:14Z","timestamp":1742591714000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Operando detection of dissolved oxygen in fluid solution using a submersible rapid scan EPR on a chip dipstick sensor"],"prefix":"10.1038","volume":"15","author":[{"given":"Joseph E.","family":"McPeak","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michele","family":"Segantini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianluca","family":"Marcozzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Irene","family":"Dona","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Silvio","family":"K\u00fcnstner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anh","family":"Chu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michal","family":"Kern","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Poncelet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benoit","family":"Driesschaert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jens","family":"Anders","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Klaus","family":"Lips","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,21]]},"reference":[{"key":"93591_CR1","doi-asserted-by":"publisher","unstructured":"Brustolon, M. & Giamello, E. (eds) Electron Paramagnetic Resonance: A Practitioner\u2019s Toolkit (Wiley, 2009). https:\/\/doi.org\/10.1002\/9780470432235.","DOI":"10.1002\/9780470432235"},{"issue":"5","key":"93591_CR2","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1002\/nbm.899","volume":"17","author":"S Liu","year":"2004","unstructured":"Liu, S., Timmins, G. S., Shi, H., Gasparovic, C. M. & Liu, K. J. Application of in vivo EPR in brain research: monitoring tissue oxygenation, blood flow, and oxidative stress. NMR Biomed. 17 (5), 327\u2013334. https:\/\/doi.org\/10.1002\/nbm.899 (2004).","journal-title":"NMR Biomed."},{"issue":"5","key":"93591_CR3","doi-asserted-by":"publisher","first-page":"3212","DOI":"10.1021\/cr900396q","volume":"110","author":"R Ahmad","year":"2010","unstructured":"Ahmad, R., Kuppusamy, P. & Theory Instrumentation, and applications of electron paramagnetic resonance oximetry. Chem. Rev. 110 (5), 3212\u20133236. https:\/\/doi.org\/10.1021\/cr900396q (2010).","journal-title":"Chem. Rev."},{"issue":"2","key":"93591_CR4","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.acra.2013.10.011","volume":"21","author":"HM Swartz","year":"2014","unstructured":"Swartz, H. M. et al. Clinical EPR: unique opportunities and some challenges. Acad. Radiol. 21 (2), 197\u2013206. https:\/\/doi.org\/10.1016\/j.acra.2013.10.011 (2014).","journal-title":"Acad. Radiol."},{"key":"93591_CR5","doi-asserted-by":"publisher","unstructured":"Halliwell, B. & Gutteridge, J. M. C. Free Radicals in Biology and Medicine (Oxford University Press, 2015). https:\/\/doi.org\/10.1093\/acprof:oso\/9780198717478.001.0001.","DOI":"10.1093\/acprof:oso\/9780198717478.001.0001"},{"key":"93591_CR6","doi-asserted-by":"publisher","first-page":"101852","DOI":"10.1016\/j.redox.2020.101852","volume":"40","author":"H Donatienne","year":"2021","unstructured":"Donatienne, H. et al. A versatile EPR toolbox for the simultaneous measurement of oxygen consumption and superoxide production. Redox Biol. 40, 101852. https:\/\/doi.org\/10.1016\/j.redox.2020.101852 (2021).","journal-title":"Redox Biol."},{"issue":"4","key":"93591_CR7","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1016\/j.freeradbiomed.2008.10.049","volume":"46","author":"N Mariappan","year":"2009","unstructured":"Mariappan, N., Elks, C. M., Fink, B., Francis, J. & TNF-Induced Mitochondrial Damage: A link between mitochondrial complex I activity and left ventricular dysfunction. Free Radic Biol. Med. 46 (4), 462\u2013470. https:\/\/doi.org\/10.1016\/j.freeradbiomed.2008.10.049 (2009).","journal-title":"Free Radic Biol. Med."},{"key":"93591_CR8","doi-asserted-by":"publisher","DOI":"10.1007\/s11307-023-01863-0","author":"RM Martin","year":"2023","unstructured":"Martin, R. M. et al. Toward a nanoencapsulated EPR imaging agent for clinical use. Mol. Imaging Biol. https:\/\/doi.org\/10.1007\/s11307-023-01863-0 (2023).","journal-title":"Mol. Imaging Biol."},{"issue":"1","key":"93591_CR9","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1002\/mrm.1910400120","volume":"40","author":"B Gallez","year":"1998","unstructured":"Gallez, B. et al. Small particles of fusinite and carbohydrate Chars coated with aqueous soluble polymers: Preparation and applications for in vivo EPR oximetry. Magn. Reson. Med. 40 (1), 152\u2013159. https:\/\/doi.org\/10.1002\/mrm.1910400120 (1998).","journal-title":"Magn. Reson. Med."},{"key":"93591_CR10","doi-asserted-by":"publisher","unstructured":"Ilangovan, G., Li, H., Zweier, J. L. & Kuppusamy, P. Electrochemical Preparation and EPR Studies of Lithium Phthalocyanine. 3. Measurements of Oxygen Concentration in Tissues and Biochemical Reactions. https:\/\/doi.org\/10.1021\/jp010130+ (2001).","DOI":"10.1021\/jp010130+"},{"issue":"1","key":"93591_CR11","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1006\/jmrb.1994.1099","volume":"105","author":"JL Zweier","year":"1994","unstructured":"Zweier, J. L., Chzhan, M., Ewert, U., Schneider, G. & Kuppusamy, P. Development of a highly sensitive probe for measuring oxygen in biological tissues. J. Magn. Reson. B. 105 (1), 52\u201357. https:\/\/doi.org\/10.1006\/jmrb.1994.1099 (1994).","journal-title":"J. Magn. Reson. B"},{"issue":"5","key":"93591_CR12","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1016\/j.freeradbiomed.2009.06.007","volume":"47","author":"AA Bobko","year":"2009","unstructured":"Bobko, A. A. et al. Trityl-Based EPR probe with enhanced sensitivity to oxygen. Free Radic Biol. Med. 47 (5), 654\u2013658. https:\/\/doi.org\/10.1016\/j.freeradbiomed.2009.06.007 (2009).","journal-title":"Free Radic Biol. Med."},{"key":"93591_CR13","doi-asserted-by":"publisher","unstructured":"Khramtsov, V. V. In Vivo spectroscopy and imaging of nitroxide probes. In Nitroxides - Theory, Experiment and Applications; InTech, https:\/\/doi.org\/10.5772\/39129. (2012).","DOI":"10.5772\/39129"},{"issue":"2","key":"93591_CR14","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/S1046-2023(03)00077-X","volume":"30","author":"JF Dunn","year":"2003","unstructured":"Dunn, J. F. & Swartz, H. M. In vivo electron paramagnetic resonance oximetry with particulate materials. Methods 30 (2), 159\u2013166. https:\/\/doi.org\/10.1016\/S1046-2023(03)00077-X (2003).","journal-title":"Methods"},{"issue":"5","key":"93591_CR15","doi-asserted-by":"publisher","first-page":"2275","DOI":"10.1002\/mrm.27182","volume":"80","author":"K Matsumoto","year":"2018","unstructured":"Matsumoto, K. et al. EPR-based oximetric imaging: A combination of single Point\u2010based Spatial encoding and T1 weighting. Magn. Reson. Med. 80 (5), 2275\u20132287. https:\/\/doi.org\/10.1002\/mrm.27182 (2018).","journal-title":"Magn. Reson. Med."},{"key":"93591_CR16","doi-asserted-by":"publisher","unstructured":"Gertsenshteyn, I. et al. Absolute Oxygen-Guided Radiation Therapy Improves Tumor Control in Three Preclinical Tumor Models. Front Med (Lausanne) 10. https:\/\/doi.org\/10.3389\/fmed.2023.1269689 (2023).","DOI":"10.3389\/fmed.2023.1269689"},{"key":"93591_CR17","doi-asserted-by":"publisher","DOI":"10.1007\/s11307-023-01852-3","author":"B Epel","year":"2023","unstructured":"Epel, B., Viswakarma, N., Sundramoorthy, S. V., Pawar, N. J. & Kotecha, M. Oxygen imaging of a rabbit tumor using a Human-Sized pulse electron paramagnetic resonance imager. Mol. Imaging Biol. https:\/\/doi.org\/10.1007\/s11307-023-01852-3 (2023).","journal-title":"Mol. Imaging Biol."},{"issue":"10","key":"93591_CR18","doi-asserted-by":"publisher","first-page":"1516","DOI":"10.1089\/ars.2013.5378","volume":"21","author":"JC Walsh","year":"2014","unstructured":"Walsh, J. C. et al. The clinical importance of assessing tumor hypoxia: relationship of tumor hypoxia to prognosis and therapeutic opportunities. Antioxid. Redox Signal. 21 (10), 1516\u20131554. https:\/\/doi.org\/10.1089\/ars.2013.5378 (2014).","journal-title":"Antioxid. Redox Signal."},{"key":"93591_CR19","doi-asserted-by":"publisher","unstructured":"Schaner, P. E. et al. OxyChip Implantation and Subsequent Electron Paramagnetic Resonance Oximetry in Human Tumors Is Safe and Feasible: First Experience in 24 Patients. Front. Oncol.. 10. https:\/\/doi.org\/10.3389\/fonc.2020.572060 (2020).","DOI":"10.3389\/fonc.2020.572060"},{"key":"93591_CR20","doi-asserted-by":"publisher","unstructured":"Epel, B., Redler, G. & Halpern, H. J. Oxygen Transport to Tissue XXXVI; Swartz, H. M., Harrison, D. K., Bruley, D. F., Eds.; Advances in Experimental Medicine and Biology; Springer New York: New York, NY, Vol. 812. https:\/\/doi.org\/10.1007\/978-1-4939-0620-8 (2014).","DOI":"10.1007\/978-1-4939-0620-8"},{"issue":"1","key":"93591_CR21","doi-asserted-by":"publisher","first-page":"16239","DOI":"10.1038\/s41598-019-52813-2","volume":"9","author":"MJR Ruigrok","year":"2019","unstructured":"Ruigrok, M. J. R. et al. The effects of oxygen concentration on cell death, Anti-Oxidant transcription, acute inflammation, and cell proliferation in Precision-Cut lung slices. Sci. Rep. 9 (1), 16239. https:\/\/doi.org\/10.1038\/s41598-019-52813-2 (2019).","journal-title":"Sci. Rep."},{"issue":"1","key":"93591_CR22","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1038\/s44303-024-00013-7","volume":"2","author":"S Hameed","year":"2024","unstructured":"Hameed, S. et al. Longitudinal, 3D oxygen imaging of cells in a Multi-Well plate using pulse electron paramagnetic resonance imaging. Npj Imaging. 2 (1), 8. https:\/\/doi.org\/10.1038\/s44303-024-00013-7 (2024).","journal-title":"Npj Imaging"},{"issue":"1","key":"93591_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1006\/jmre.1998.1438","volume":"133","author":"JH Ardenkj\u00e6r-Larsen","year":"1998","unstructured":"Ardenkj\u00e6r-Larsen, J. H. et al. EPR and DNP properties of certain novel single electron contrast agents intended for oximetric imaging. J. Magn. Reson. 133 (1), 1\u201312. https:\/\/doi.org\/10.1006\/jmre.1998.1438 (1998).","journal-title":"J. Magn. Reson."},{"issue":"1","key":"93591_CR24","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1006\/jmre.2001.2379","volume":"152","author":"L Yong","year":"2001","unstructured":"Yong, L. et al. Electron spin relaxation of triarylmethyl radicals in fluid solution. J. Magn. Reson. 152 (1), 156\u2013161. https:\/\/doi.org\/10.1006\/jmre.2001.2379 (2001).","journal-title":"J. Magn. Reson."},{"issue":"5","key":"93591_CR25","doi-asserted-by":"publisher","first-page":"1001","DOI":"10.1002\/mrm.10133","volume":"47","author":"S Subramanian","year":"2002","unstructured":"Subramanian, S. et al. Noninvasive in vivo oximetric imaging by radiofrequency FT EPR. Magn. Reson. Med. 47 (5), 1001\u20131008. https:\/\/doi.org\/10.1002\/mrm.10133 (2002).","journal-title":"Magn. Reson. Med."},{"issue":"4","key":"93591_CR26","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1002\/mrm.10089","volume":"47","author":"BB Williams","year":"2002","unstructured":"Williams, B. B. et al. Imaging spin probe distribution in the tumor of a living mouse with 250\u00a0mhz EPR: correlation with BOLD MRI. Magn. Reson. Med. 47 (4), 634\u2013638. https:\/\/doi.org\/10.1002\/mrm.10089 (2002).","journal-title":"Magn. Reson. Med."},{"issue":"4","key":"93591_CR27","doi-asserted-by":"publisher","first-page":"1543","DOI":"10.1002\/9780470034590.emrstm1507","volume":"5","author":"SS Eaton","year":"2016","unstructured":"Eaton, S. S. & Eaton, G. R. Relaxation mechanisms. eMagRes 5 (4), 1543\u20131556. https:\/\/doi.org\/10.1002\/9780470034590.emrstm1507 (2016).","journal-title":"eMagRes"},{"issue":"1","key":"93591_CR28","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1016\/j.jmr.2004.10.007","volume":"172","author":"R Owenius","year":"2005","unstructured":"Owenius, R., Eaton, G. R. & Eaton, S. S. Frequency (250\u00a0MHz to 9.2 GHz) and viscosity dependence of electron spin relaxation of triarylmethyl radicals at room temperature. J. Magn. Reson. 172 (1), 168\u2013175. https:\/\/doi.org\/10.1016\/j.jmr.2004.10.007 (2005).","journal-title":"J. Magn. Reson."},{"issue":"18\u201319","key":"93591_CR29","doi-asserted-by":"publisher","first-page":"2664","DOI":"10.1080\/00268976.2013.792959","volume":"111","author":"DG Mitchell","year":"2013","unstructured":"Mitchell, D. G. et al. X-Band Rapid-Scan EPR of samples with long electron spin relaxation times: A comparison of continuous wave, pulse and Rapid-Scan EPR. Mol. Phys. 111 (18\u201319), 2664\u20132673. https:\/\/doi.org\/10.1080\/00268976.2013.792959 (2013).","journal-title":"Mol. Phys."},{"key":"93591_CR30","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1016\/j.jmr.2017.02.013","volume":"280","author":"SS Eaton","year":"2017","unstructured":"Eaton, S. S. et al. Rapid-Scan EPR imaging. J. Magn. Reson. 280, 140\u2013148. https:\/\/doi.org\/10.1016\/j.jmr.2017.02.013 (2017).","journal-title":"J. Magn. Reson."},{"issue":"1","key":"93591_CR31","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.jmr.2005.03.013","volume":"175","author":"JP Joshi","year":"2005","unstructured":"Joshi, J. P. et al. Rapid-Scan EPR with triangular scans and fourier Deconvolution to recover the Slow-Scan spectrum. J. Magn. Reson. 175 (1), 44\u201351. https:\/\/doi.org\/10.1016\/j.jmr.2005.03.013 (2005).","journal-title":"J. Magn. Reson."},{"issue":"2","key":"93591_CR32","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1016\/j.jmr.2010.11.015","volume":"208","author":"M Tseitlin","year":"2011","unstructured":"Tseitlin, M., Rinard, G. A., Quine, R. W., Eaton, S. S. & Eaton, G. R. Deconvolution of sinusoidal rapid EPR scans. J. Magn. Reson. 208 (2), 279\u2013283. https:\/\/doi.org\/10.1016\/j.jmr.2010.11.015 (2011).","journal-title":"J. Magn. Reson."},{"issue":"4","key":"93591_CR33","doi-asserted-by":"publisher","first-page":"1529","DOI":"10.1002\/9780470034590.emrstm1522","volume":"5","author":"GR Eaton","year":"2016","unstructured":"Eaton, G. R., Eaton, S. S. & Rapid-Scan Electron. Paramagnetic Reson. eMagRes 5 (4), 1529\u20131542. https:\/\/doi.org\/10.1002\/9780470034590.emrstm1522. (2016).","journal-title":"Electron. Paramagnetic Reson. eMagRes"},{"issue":"1","key":"93591_CR34","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.jmr.2003.12.005","volume":"167","author":"YE Nesmelov","year":"2004","unstructured":"Nesmelov, Y. E., Gopinath, A. & Thomas, D. D. Aqueous sample in an EPR cavity: sensitivity considerations. J. Magn. Reson. 167 (1), 138\u2013146. https:\/\/doi.org\/10.1016\/j.jmr.2003.12.005 (2004).","journal-title":"J. Magn. Reson."},{"key":"93591_CR35","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.jmr.2011.11.007","volume":"214","author":"DG Mitchell","year":"2012","unstructured":"Mitchell, D. G., Quine, R. W., Tseitlin, M., Eaton, S. S. & Eaton, G. R. X-Band Rapid-Scan EPR of nitroxyl radicals. J. Magn. Reson. 214, 221\u2013226. https:\/\/doi.org\/10.1016\/j.jmr.2011.11.007 (2012).","journal-title":"J. Magn. Reson."},{"key":"93591_CR36","doi-asserted-by":"publisher","unstructured":"Eaton, G. R. & Eaton, S. S. Advances in rapid scan EPR spectroscopy. In Methods in Enzymology; Academic Press Inc. Vol. 666, 1\u201324. https:\/\/doi.org\/10.1016\/bs.mie.2022.02.013 (2022).","DOI":"10.1016\/bs.mie.2022.02.013"},{"key":"93591_CR37","doi-asserted-by":"publisher","unstructured":"Handwerker, J. et al. 28.2 A 14GHz Battery-Operated Point-of-Care ESR Spectrometer Based on a 0.13\u00b5m CMOS ASIC. In IEEE International Solid-State Circuits Conference (ISSCC); IEEE, 2016; pp 476\u2013477. https:\/\/doi.org\/10.1109\/ISSCC.2016.7418114 (2016).","DOI":"10.1109\/ISSCC.2016.7418114"},{"key":"93591_CR38","doi-asserted-by":"publisher","unstructured":"Yalcin, T. & Boero, G. Single-Chip detector for electron spin resonance spectroscopy. Rev. Sci. Instrum. 79 (9). https:\/\/doi.org\/10.1063\/1.2969657 (2008).","DOI":"10.1063\/1.2969657"},{"key":"93591_CR39","doi-asserted-by":"publisher","unstructured":"Schlecker, B. et al. VCO-Based ESR-on-a-Chip as a tool for Low-Cost, High-Sensitivity Point-of-Care diagnostics. In 2017 IEEE SENSORS; IEEE, 1\u20133. https:\/\/doi.org\/10.1109\/ICSENS.2017.8233896. (2017).","DOI":"10.1109\/ICSENS.2017.8233896"},{"key":"93591_CR40","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.jmr.2019.07.007","volume":"306","author":"J Anders","year":"2019","unstructured":"Anders, J. & Lips, K. MR to go. J. Magn. Reson. 306, 118\u2013123. https:\/\/doi.org\/10.1016\/j.jmr.2019.07.007 (2019).","journal-title":"J. Magn. Reson."},{"issue":"11","key":"93591_CR41","doi-asserted-by":"publisher","first-page":"3727","DOI":"10.1109\/TMTT.2015.2481895","volume":"63","author":"X Yang","year":"2015","unstructured":"Yang, X., Babakhani, A. A. & Single-Chip Electron paramagnetic resonance transceiver in 0.13-\u039cm SiGe BiCMOS. IEEE Trans. Microw. Theory Tech. 63 (11), 3727\u20133735. https:\/\/doi.org\/10.1109\/TMTT.2015.2481895 (2015).","journal-title":"IEEE Trans. Microw. Theory Tech."},{"issue":"3","key":"93591_CR42","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1109\/MSSC.2014.2329234","volume":"6","author":"B Razavi","year":"2014","unstructured":"Razavi, B. The Cross-Coupled Pair - Part I [A circuit for all seasons]. IEEE Solid-State Circuits Mag. 6 (3), 7\u201310. https:\/\/doi.org\/10.1109\/MSSC.2014.2329234 (2014).","journal-title":"IEEE Solid-State Circuits Mag."},{"key":"93591_CR43","doi-asserted-by":"publisher","unstructured":"Chu, A., Schlecker, B., Lips, K., Ortmanns, M. & Anders, J. An 8-Channel 13GHz ESR-on-a-Chip Injection-Locked Vco-Array Achieving 200\u00b5M-Concentration Sensitivity. In IEEE International Solid - State Circuits Conference - (ISSCC); IEEE, 2018; pp 354\u2013356. https:\/\/doi.org\/10.1109\/ISSCC.2018.8310330 (2018).","DOI":"10.1109\/ISSCC.2018.8310330"},{"issue":"2","key":"93591_CR44","doi-asserted-by":"publisher","first-page":"699","DOI":"10.5194\/mr-2-699-2021","volume":"2","author":"A Chu","year":"2021","unstructured":"Chu, A. et al. On the modeling of Amplitude-Sensitive electron spin resonance (ESR) detection using Voltage-Controlled oscillator (VCO)-Based ESR-on-a-Chip detectors. Magn. Reson. 2 (2), 699\u2013713. https:\/\/doi.org\/10.5194\/mr-2-699-2021 (2021).","journal-title":"Magn. Reson."},{"key":"93591_CR45","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1007\/978-3-319-58996-1_4","volume":"109","author":"J Anders","year":"2018","unstructured":"Anders, J. Nonlinear modeling of Continuous-Wave spin detection using Oscillator-Based ESR-on-a-Chip sensors. In Studies in systems, decision and control. Springer Int. Publishing. 109, 57\u201387. https:\/\/doi.org\/10.1007\/978-3-319-58996-1_4 (2018).","journal-title":"Springer Int. Publishing"},{"key":"93591_CR46","doi-asserted-by":"publisher","unstructured":"Chu, A. et al. VCO-Based ESR-on-a-Chip as a Tool for Low-Cost, High-Sensitivity Food Quality Control. In 2017 IEEE Biomedical Circuits and Systems Conference (BioCAS); IEEE, ; pp 1\u20134 (2017). https:\/\/doi.org\/10.1109\/BIOCAS.2017.8325172.","DOI":"10.1109\/BIOCAS.2017.8325172"},{"issue":"25","key":"93591_CR47","doi-asserted-by":"publisher","first-page":"17785","DOI":"10.1039\/D4CP00373J","volume":"26","author":"S K\u00fcnstner","year":"2024","unstructured":"K\u00fcnstner, S. et al. Monitoring the state of charge of vanadium redox flow batteries with an EPR-on-a-Chip dipstick sensor. Phys. Chem. Chem. Phys. 26 (25), 17785\u201317795. https:\/\/doi.org\/10.1039\/D4CP00373J (2024).","journal-title":"Phys. Chem. Chem. Phys."},{"issue":"2","key":"93591_CR48","doi-asserted-by":"publisher","first-page":"673","DOI":"10.5194\/mr-2-673-2021","volume":"2","author":"S K\u00fcnstner","year":"2021","unstructured":"K\u00fcnstner, S. et al. Rapid-Scan electron paramagnetic resonance using an EPR-on-a-Chip sensor. Magn. Reson. 2 (2), 673\u2013687. https:\/\/doi.org\/10.5194\/mr-2-673-2021 (2021).","journal-title":"Magn. Reson."},{"key":"93591_CR49","doi-asserted-by":"publisher","unstructured":"Hassan, M. A. et al. A 14-Channel 7 GHz VCO-Based EPR-on-a-Chip Sensor with Rapid Scan Capabilities. In 2021 IEEE Sensors; Vol. 2021-October, pp 1\u20134. https:\/\/doi.org\/10.1109\/SENSORS47087.2021.9639513 (2021).","DOI":"10.1109\/SENSORS47087.2021.9639513"},{"key":"93591_CR50","doi-asserted-by":"crossref","unstructured":"K\u00fcnstner, S. et al. Microwave Field Mapping for EPR on a Chip Experiments. Sci Adv Accepted. (2024).","DOI":"10.1126\/sciadv.ado5467"},{"key":"93591_CR51","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.jmr.2018.09.005","volume":"296","author":"O Laguta","year":"2018","unstructured":"Laguta, O., Tu\u010dek, M., van Slageren, J. & Neugebauer, P. Multi-Frequency Rapid-Scan HFEPR. J. Magn. Reson. 296, 138\u2013142. https:\/\/doi.org\/10.1016\/j.jmr.2018.09.005 (2018).","journal-title":"J. Magn. Reson."},{"issue":"1","key":"93591_CR52","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.jmr.2010.04.005","volume":"205","author":"JS Hyde","year":"2010","unstructured":"Hyde, J. S., Strangeway, R. A., Camenisch, T. G., Ratke, J. J. & Froncisz, W. W. -Band Frequency-Swept EPR. J. Magn. Reson. 205 (1), 93\u2013101. https:\/\/doi.org\/10.1016\/j.jmr.2010.04.005 (2010).","journal-title":"J. Magn. Reson."},{"issue":"2","key":"93591_CR53","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/j.jmr.2007.01.002","volume":"185","author":"JS Hyde","year":"2007","unstructured":"Hyde, J. S. et al. Microwave frequency modulation in CW EPR at W-Band using a Loop-Gap resonator. J. Magn. Reson. 185 (2), 259\u2013263. https:\/\/doi.org\/10.1016\/j.jmr.2007.01.002 (2007).","journal-title":"J. Magn. Reson."},{"key":"93591_CR54","doi-asserted-by":"crossref","unstructured":"Segantini, M. et al. Compact Electron Paramagnetic Resonance on a Chip Spectrometer Using a Single Sided Permanent Magnet. ACS Sens Submitted. (2024).","DOI":"10.1021\/acssensors.4c00788"},{"issue":"12","key":"93591_CR55","doi-asserted-by":"publisher","first-page":"1934","DOI":"10.1063\/1.1136918","volume":"53","author":"JS Hyde","year":"1982","unstructured":"Hyde, J. S., Froncisz, W. & Kusumi, A. Dispersion electron spin resonance with the Loop-Gap resonator. Rev. Sci. Instrum. 53 (12), 1934\u20131937. https:\/\/doi.org\/10.1063\/1.1136918 (1982).","journal-title":"Rev. Sci. Instrum."},{"issue":"1","key":"93591_CR56","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1006\/jmra.1996.0174","volume":"122","author":"GA Rinard","year":"1996","unstructured":"Rinard, G. A., Quine, R. W., Ghim, B. T., Eaton, S. S. & Eaton, G. R. Dispersion and superheterodyne EPR using a bimodal resonator. J. Magn. Reson. A. 122 (1), 58\u201363. https:\/\/doi.org\/10.1006\/jmra.1996.0174 (1996).","journal-title":"J. Magn. Reson. A"},{"issue":"60","key":"93591_CR57","doi-asserted-by":"publisher","first-page":"35073","DOI":"10.1039\/C9RA08633A","volume":"9","author":"M Poncelet","year":"2019","unstructured":"Poncelet, M., Huffman, J. L., Khramtsov, V. V., Dhimitruka, I. & Driesschaert, B. Synthesis of hydroxyethyl Tetrathiatriarylmethyl radicals OX063 and OX071. RSC Adv. 9 (60), 35073\u201335076. https:\/\/doi.org\/10.1039\/C9RA08633A (2019).","journal-title":"RSC Adv."},{"issue":"24","key":"93591_CR58","doi-asserted-by":"publisher","first-page":"5643","DOI":"10.1039\/D2AN01527G","volume":"147","author":"M Poncelet","year":"2022","unstructured":"Poncelet, M. et al. Synthesis and characterization of a biocompatible 13C1 isotopologue of trityl radical OX071 for in vivo EPR viscometry. Analyst 147 (24), 5643\u20135648. https:\/\/doi.org\/10.1039\/D2AN01527G (2022).","journal-title":"Analyst"},{"key":"93591_CR59","doi-asserted-by":"publisher","unstructured":"Anders, J., Fully-Integrated, C. M. O. S. & Lausanne Probes for Magnetic Resonance Applications, EPFL. https:\/\/doi.org\/10.5075\/epfl-thesis-5154 (2011).","DOI":"10.5075\/epfl-thesis-5154"},{"key":"93591_CR60","doi-asserted-by":"publisher","unstructured":"Khan, K. et al. A 12.2 to 14.9 GHz Injection-Locked VCO Array with an on-Chip 50\u00a0MHz BW Semi-Digital PLL for Transient Spin Manipulation and Detection. In 2022 IEEE 65th International Midwest Symposium on Circuits and Systems (MWSCAS); IEEE, ; Vol. 2022-August, pp 1\u20134. (2022). https:\/\/doi.org\/10.1109\/MWSCAS54063.2022.9859288.","DOI":"10.1109\/MWSCAS54063.2022.9859288"},{"issue":"11\u201312","key":"93591_CR61","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1515\/freq-2022-0096","volume":"76","author":"MA Hassan","year":"2022","unstructured":"Hassan, M. A. et al. Towards Single-Cell pulsed EPR using VCO-Based EPR-on-a-Chip detectors. Frequenz 76(11\u201312), 699\u2013717. https:\/\/doi.org\/10.1515\/freq-2022-0096 (2022).","journal-title":"Frequenz"},{"key":"93591_CR62","doi-asserted-by":"publisher","first-page":"106860","DOI":"10.1016\/j.jmr.2020.106860","volume":"322","author":"J Anders","year":"2021","unstructured":"Anders, J. et al. Progress in miniaturization and Low-Field nuclear magnetic resonance. J. Magn. Reson. 322, 106860. https:\/\/doi.org\/10.1016\/j.jmr.2020.106860 (2021).","journal-title":"J. Magn. Reson."},{"issue":"1","key":"93591_CR63","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.jmr.2004.06.008","volume":"170","author":"JW Stoner","year":"2004","unstructured":"Stoner, J. W. et al. Direct-Detected Rapid-Scan EPR at 250 MHz. J. Magn. Reson. 170 (1), 127\u2013135. https:\/\/doi.org\/10.1016\/j.jmr.2004.06.008 (2004).","journal-title":"J. Magn. Reson."},{"issue":"5","key":"93591_CR64","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.1103\/PhysRev.91.1071","volume":"91","author":"AM Portis","year":"1953","unstructured":"Portis, A. M. Electronic structure of F centers: saturation of the electron spin resonance. Phys. Rev. 91 (5), 1071\u20131078. https:\/\/doi.org\/10.1103\/PhysRev.91.1071 (1953).","journal-title":"Phys. Rev."},{"issue":"1","key":"93591_CR65","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.jmr.2005.08.013","volume":"178","author":"S Stoll","year":"2006","unstructured":"Stoll, S. & Schweiger, A. EasySpin, a comprehensive software package for spectral simulation and analysis in EPR. J. Magn. Reson. 178 (1), 42\u201355. https:\/\/doi.org\/10.1016\/j.jmr.2005.08.013 (2006).","journal-title":"J. Magn. Reson."},{"key":"93591_CR66","doi-asserted-by":"publisher","unstructured":"Dalal, D. P., Eaton, S. S. & Eaton, G. R. The Effects of Lossy Solvents on Quantitative EPR Studies. J. Magn. Reson. 44(3), 415\u2013428. https:\/\/doi.org\/10.1016\/0022-2364(81)90276-6 (1969).","DOI":"10.1016\/0022-2364(81)90276-6"},{"issue":"2","key":"93591_CR67","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/j.jmr.2010.01.013","volume":"203","author":"M Tseitlin","year":"2010","unstructured":"Tseitlin, M., Quine, R. W., Rinard, G. A., Eaton, S. S. & Eaton, G. R. Combining absorption and dispersion signals to improve Signal-to-Noise for Rapid-Scan EPR imaging. J. Magn. Reson. 203 (2), 305\u2013310. https:\/\/doi.org\/10.1016\/j.jmr.2010.01.013 (2010).","journal-title":"J. Magn. Reson."},{"issue":"7","key":"93591_CR68","doi-asserted-by":"publisher","first-page":"183","DOI":"10.3390\/magnetochemistry9070183","volume":"9","author":"M Segantini","year":"2023","unstructured":"Segantini, M. et al. Electrically detected magnetic resonance on a chip (EDMRoC) for analysis of Thin-Film silicon photovoltaics. Magnetochemistry 9 (7), 183. https:\/\/doi.org\/10.3390\/magnetochemistry9070183 (2023).","journal-title":"Magnetochemistry"},{"issue":"4","key":"93591_CR69","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1002\/cmr.b.21222","volume":"41B","author":"RW Quine","year":"2012","unstructured":"Quine, R. W., Mitchell, D. G., Tseitlin, M., Eaton, S. S. & Eaton, G. R. A resonated coil driver for rapid scan EPR. Concepts Magn. Reson. Part. B Magn. Reson. Eng. 41B (4), 95\u2013110. https:\/\/doi.org\/10.1002\/cmr.b.21222 (2012).","journal-title":"Concepts Magn. Reson. Part. B Magn. Reson. Eng."},{"issue":"1","key":"93591_CR70","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1002\/cmr.b.20128","volume":"35B","author":"RW Quine","year":"2009","unstructured":"Quine, R. W., Czechowski, T. & Eaton, G. R. A linear magnetic field scan driver. Concepts Magn. Reson. Part. B Magn. Reson. Eng. 35B (1), 44\u201358. https:\/\/doi.org\/10.1002\/cmr.b.20128 (2009).","journal-title":"Concepts Magn. Reson. Part. B Magn. Reson. Eng."},{"issue":"11","key":"93591_CR71","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1109\/LMWC.2016.2615002","volume":"26","author":"YJ Lin","year":"2016","unstructured":"Lin, Y. J., Tseng, Y. C. & Wu, T. L. A Resonator-Based suppressor for mitigating the noise transfer on metal plates for control of electromagnetic interference. IEEE Microwave Wirel. Compon. Lett. 26 (11), 906\u2013908. https:\/\/doi.org\/10.1109\/LMWC.2016.2615002 (2016).","journal-title":"IEEE Microwave Wirel. Compon. Lett."},{"key":"93591_CR72","doi-asserted-by":"publisher","unstructured":"Eaton, G. R., Eaton, S. S., Barr, D. P., Weber, R. T. & Quantitative, E. P. R. Springer Vienna: Vienna, (2010). https:\/\/doi.org\/10.1007\/978-3-211-92948-3","DOI":"10.1007\/978-3-211-92948-3"},{"key":"93591_CR73","doi-asserted-by":"publisher","first-page":"100005","DOI":"10.1016\/j.jmro.2020.100005","volume":"2-3","author":"N Dayan","year":"2020","unstructured":"Dayan, N. et al. Electron spin resonance microfluidics with subnanoliter liquid samples. J. Magn. Reson. Open. 2-3, 100005. https:\/\/doi.org\/10.1016\/j.jmro.2020.100005 (2020).","journal-title":"J. Magn. Reson. Open."},{"issue":"1","key":"93591_CR74","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1038\/s41592-019-0640-3","volume":"17","author":"J Handwerker","year":"2020","unstructured":"Handwerker, J. et al. A CMOS NMR needle for probing brain physiology with high Spatial and Temporal resolution. Nat. Methods. 17 (1), 64\u201367. https:\/\/doi.org\/10.1038\/s41592-019-0640-3 (2020).","journal-title":"Nat. Methods"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-93591-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-93591-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-93591-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,21]],"date-time":"2025-03-21T21:15:23Z","timestamp":1742591723000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-93591-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,21]]},"references-count":74,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["93591"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-93591-4","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,21]]},"assertion":[{"value":"25 September 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"9872"}}