{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T08:27:02Z","timestamp":1793089622010,"version":"4.5.0"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T00:00:00Z","timestamp":1743120000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T00:00:00Z","timestamp":1743120000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002839","name":"Charit\u00e9 - Universit\u00e4tsmedizin Berlin","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100002839","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>To compare pretrained and trained U-Nets for liver and spleen segmentation in multifrequency magnetic resonance elastography (MRE) magnitude images for automated quantification of shear wave speed (SWS). Seventy-two healthy participants (34\u2009\u00b1\u200911 years; BMI, 23\u2009\u00b1\u20092 kg\/m<jats:sup>2<\/jats:sup>; 51 men) underwent multifrequency MRE at 1.5T or 3T. Volumes of interest (VOIs) of liver and spleen were generated from MRE magnitude images with mixed T2-T2* image contrast and then transferred to SWS maps. Pretrained and trained 2D and 3D U-Nets were compared with ground truth values obtained by manual segmentation using correlation analysis, intraclass correlation coefficients (ICCs), and Dice scores. For both VOI and SWS values, pairwise comparison revealed no statistically significant difference between ground truth and pretrained and trained U-Nets (all <jats:italic>p<\/jats:italic>\u2009\u2265\u20090.95). There was a strong positive correlation for SWS between ground truth and U-Nets with <jats:italic>R<\/jats:italic>\u2009=\u20090.99 for liver and <jats:italic>R<\/jats:italic>\u2009=\u20090.81\u20130.84 for spleen. ICC was 0.99 for liver and 0.90\u20130.92 for spleen, indicating excellent agreement for liver and good agreement for spleen for all U-Nets investigated. Dice scores showed excellent segmentation performance for all networks with the 2D U-Net achieving slightly higher values for the liver (0.95) and spleen (0.90), though the differences between the three tested U-Nets were minimal. The excellent performance we found for automated liver and spleen segmentation when applying 2D and 3D U-Nets to MRE magnitude images suggests that fully automated quantification of MRE parameters within anatomical regions is feasible by leveraging the previously unexploited anatomical information conveyed in MRE magnitude images.<\/jats:p>","DOI":"10.1038\/s41598-025-95157-w","type":"journal-article","created":{"date-parts":[[2025,3,29]],"date-time":"2025-03-29T07:43:45Z","timestamp":1743234225000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Automated liver and spleen segmentation for MR elastography maps using U-Nets"],"prefix":"10.1038","volume":"15","author":[{"given":"Noah","family":"Jaitner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jakob","family":"Ludwig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom","family":"Meyer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oliver","family":"Boehm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Anders","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Biru","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jakob","family":"Jordan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Schaeffter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ingolf","family":"Sack","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rolf","family":"Reiter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,28]]},"reference":[{"issue":"4","key":"95157_CR1","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1097\/HEP.0000000000000004","volume":"77","author":"ZM Younossi","year":"2023","unstructured":"Younossi, Z. M. et al. The global epidemiology of nonalcoholic fatty liver disease (NAFLD) and nonalcoholic steatohepatitis (NASH): a systematic review. Hepatology 77(4), 1335\u20131347 (2023).","journal-title":"Hepatology"},{"issue":"5","key":"95157_CR2","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1097\/HEP.0000000000000323","volume":"77","author":"ME Rinella","year":"2023","unstructured":"Rinella, M. E. et al. AASLD practice guidance on the clinical assessment and management of nonalcoholic fatty liver disease. Hepatology 77(5), 1797\u20131835 (2023).","journal-title":"Hepatology"},{"key":"95157_CR3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.pnmrs.2024.05.002","volume":"144\u2013145","author":"T Meyer","year":"2024","unstructured":"Meyer, T. et al. Magnetic resonance elastography in a nutshell: tomographic imaging of soft tissue viscoelasticity for detecting and staging disease with a focus on inflammation. Progress Nucl. Magn. Reson. Spectrosc. 144\u2013145, 1\u201314 (2024).","journal-title":"Progress Nucl. Magn. Reson. Spectrosc."},{"key":"95157_CR4","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1038\/s42254-022-00543-2","volume":"5","author":"I Sack","year":"2022","unstructured":"Sack, I. Magnetic resonance elastography from fundamental soft-tissue mechanics to diagnostic imaging. Nat. Reviews Phys. 5, 25\u201342 (2022).","journal-title":"Nat. Reviews Phys."},{"key":"95157_CR5","doi-asserted-by":"crossref","first-page":"104645","DOI":"10.1016\/j.jmbbm.2021.104645","volume":"121","author":"R Reiter","year":"2021","unstructured":"Reiter, R. et al. Influence of fibrosis progression on the viscous properties of in vivo liver tissue elucidated by shear wave dispersion in multifrequency MR elastography. J. Mech. Behav. Biomed. Mater. 121, 104645 (2021).","journal-title":"J. Mech. Behav. Biomed. Mater."},{"issue":"3","key":"95157_CR6","doi-asserted-by":"crossref","first-page":"1719","DOI":"10.1007\/s00330-019-06471-7","volume":"30","author":"R Reiter","year":"2020","unstructured":"Reiter, R. et al. Diagnostic performance of tomoelastography of the liver and spleen for staging hepatic fibrosis. Eur. Radiol. 30(3), 1719\u20131729 (2020).","journal-title":"Eur. Radiol."},{"issue":"1","key":"95157_CR7","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1148\/radiol.2021202804","volume":"301","author":"Y Shi","year":"2021","unstructured":"Shi, Y. et al. Three-dimensional MR elastography depicts liver inflammation, fibrosis, and portal hypertension in chronic hepatitis B or C. Radiology 301(1), 154\u2013162 (2021).","journal-title":"Radiology"},{"issue":"1","key":"95157_CR8","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1002\/jmri.22610","volume":"34","author":"GI Nedredal","year":"2011","unstructured":"Nedredal, G. I. et al. Portal hypertension correlates with Splenic stiffness as measured with MR elastography. J. Magn. Reson. Imaging. 34(1), 79\u201387 (2011).","journal-title":"J. Magn. Reson. Imaging"},{"issue":"2","key":"95157_CR9","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1002\/jmri.24165","volume":"39","author":"S Hirsch","year":"2014","unstructured":"Hirsch, S. et al. Towards compression-sensitive magnetic resonance elastography of the liver: sensitivity of harmonic volumetric strain to portal hypertension. J. Magn. Reson. Imaging. 39(2), 298\u2013306 (2014).","journal-title":"J. Magn. Reson. Imaging"},{"issue":"2","key":"95157_CR10","doi-asserted-by":"crossref","first-page":"1429","DOI":"10.21037\/qims-22-1415","volume":"14","author":"D Xinjun Han","year":"2024","unstructured":"Xinjun Han, D., Yang, H., Xu, Y., Wang, H. & Yin, Yang, Z. Superiority of spleen stiffness on two-dimensional magnetic resonance elastography over liver stiffness and serum tests in assessing portal hypertension in chronic liver disease. Quant. Imaging Med. Surg. 14(2), 1429\u20131440 (2024).","journal-title":"Quant. Imaging Med. Surg."},{"key":"95157_CR11","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.actbio.2023.07.033","volume":"169","author":"Y Safraou","year":"2023","unstructured":"Safraou, Y. et al. The influence of static portal pressure on liver biophysical properties. Acta Biomater. 169, 118\u2013129 (2023).","journal-title":"Acta Biomater."},{"key":"95157_CR12","unstructured":"Ronneberger, O., Fischer, P. & Brox, T. (eds) U-net: Convolutional networks for biomedical image segmentation. In Medical Image Computing and Computer-Assisted Intervention\u2013MICCAI 2015: 18th International Conference, Munich, Germany, October 5\u20139, 2015, Proceedings, Part III 18 (Springer,  2015)."},{"issue":"2","key":"95157_CR13","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1002\/jmri.23980","volume":"38","author":"B Dzyubak","year":"2013","unstructured":"Dzyubak, B. et al. Automated liver stiffness measurements with magnetic resonance elastography. J. Magn. Reson. Imaging. 38(2), 371\u2013379 (2013).","journal-title":"J. Magn. Reson. Imaging"},{"issue":"5","key":"95157_CR14","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1002\/jmri.25072","volume":"43","author":"B Dzyubak","year":"2016","unstructured":"Dzyubak, B., Venkatesh, S. K., Manduca, A., Glaser, K. J. & Ehman, R. L. Automated liver elasticity calculation for MR elastography. J. Magn. Reson. Imaging 43(5), 1055\u20131063 (2016).","journal-title":"J. Magn. Reson. Imaging"},{"key":"95157_CR15","doi-asserted-by":"crossref","unstructured":"Wang, K. et al. Automated CT and MRI liver segmentation and biometry using a generalized convolutional neural network. Radiol. Artif. Intell. 1, 2 (2019).","DOI":"10.1148\/ryai.2019180022"},{"issue":"3","key":"95157_CR16","doi-asserted-by":"crossref","first-page":"e220080","DOI":"10.1148\/ryai.220080","volume":"5","author":"B Konkel","year":"2023","unstructured":"Konkel, B. et al. Systematic analysis of common factors impacting deep learning model generalizability in liver segmentation. Radiol. Artif. Intell. 5(3), e220080 (2023).","journal-title":"Radiol. Artif. Intell."},{"issue":"4","key":"95157_CR17","doi-asserted-by":"crossref","first-page":"1804","DOI":"10.3390\/tomography8040152","volume":"8","author":"A Sharbatdaran","year":"2022","unstructured":"Sharbatdaran, A. et al. Deep learning automation of kidney, liver, and spleen segmentation for organ volume measurements in autosomal dominant polycystic kidney disease. Tomography 8(4), 1804\u20131819 (2022).","journal-title":"Tomography"},{"issue":"1","key":"95157_CR18","doi-asserted-by":"crossref","first-page":"9820","DOI":"10.1038\/s41598-021-89372-4","volume":"11","author":"R Reiter","year":"2021","unstructured":"Reiter, R. et al. Spatial heterogeneity of hepatic fibrosis in primary sclerosing cholangitis vs. viral hepatitis assessed by MR elastography. Sci. Rep. 11(1), 9820 (2021).","journal-title":"Sci. Rep."},{"issue":"4","key":"95157_CR19","doi-asserted-by":"crossref","first-page":"1962","DOI":"10.1002\/mrm.28558","volume":"85","author":"M Shahryari","year":"2021","unstructured":"Shahryari, M. et al. Reduction of breathing artifacts in multifrequency magnetic resonance elastography of the abdomen. Magn. Reson. Med. 85(4), 1962\u20131973 (2021).","journal-title":"Magn. Reson. Med."},{"key":"95157_CR20","doi-asserted-by":"crossref","unstructured":"Aldoj, N. et al. Fully automated quantification of in vivo viscoelasticity of prostate zones using magnetic resonance elastography with dense U-net segmentation. Sci. Rep. 12, 1  (2022).","DOI":"10.1038\/s41598-022-05878-5"},{"key":"95157_CR21","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.aiopen.2021.08.002","volume":"2","author":"X Han","year":"2021","unstructured":"Han, X. et al. Pre-trained models: past, present and future. AI Open. 2, 225\u2013250 (2021).","journal-title":"AI Open."},{"issue":"1","key":"95157_CR22","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1002\/mrm.29859","volume":"91","author":"M Anders","year":"2024","unstructured":"Anders, M. et al. Rapid MR elastography of the liver for subsecond stiffness sampling. Magn. Reson. Med. 91(1), 312\u2013324 (2024).","journal-title":"Magn. Reson. Med."},{"issue":"4","key":"95157_CR23","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1002\/mrm.26006","volume":"76","author":"F Dittmann","year":"2016","unstructured":"Dittmann, F. et al. In vivo wideband multifrequency MR elastography of the human brain and liver. Magn. Reson. Med. 76(4), 1116\u20131126 (2016).","journal-title":"Magn. Reson. Med."},{"issue":"1","key":"95157_CR24","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1073\/pnas.1913511116","volume":"117","author":"KJ Streitberger","year":"2020","unstructured":"Streitberger, K. J. et al. How tissue fluidity influences brain tumor progression. Proc. Natl. Acad. Sci. U S A. 117(1), 128\u2013134 (2020).","journal-title":"Proc. Natl. Acad. Sci. U S A"},{"key":"95157_CR25","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.media.2016.01.001","volume":"30","author":"H Tzschatzsch","year":"2016","unstructured":"Tzschatzsch, H. et al. Tomoelastography by multifrequency wave number recovery from time-harmonic propagating shear waves. Med. Image Anal. 30, 1\u201310 (2016).","journal-title":"Med. Image Anal."},{"issue":"4","key":"95157_CR26","doi-asserted-by":"crossref","first-page":"1840","DOI":"10.1002\/mrm.29320","volume":"88","author":"T Meyer","year":"2022","unstructured":"Meyer, T. et al. Comparison of inversion methods in MR elastography: an open-access pipeline for processing multifrequency shear-wave data and demonstration in a Phantom, human kidneys, and brain. Magn. Reson. Med. 88(4), 1840\u20131850 (2022).","journal-title":"Magn. Reson. Med."},{"issue":"2","key":"95157_CR27","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1038\/s41592-020-01008-z","volume":"18","author":"F Isensee","year":"2021","unstructured":"Isensee, F., Jaeger, P. F., Kohl, S. A. A., Petersen, J. & Maier-Hein, K. H. nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation. Nat. Methods 18(2), 203\u2013211 (2021).","journal-title":"Nat. Methods"},{"key":"95157_CR28","unstructured":"Kingma, D. P. & Ba, J.  Adam A method for stochastic optimization. ArXiv Preprint arXiv:14126980 (2014)."},{"key":"95157_CR29","unstructured":"Maas, A. L., Hannun, A. Y. & Ng, A. Y. (eds) Rectifier Nonlinearities Improve Neural Network Acoustic Models (Proc icml, 2013)."},{"issue":"1","key":"95157_CR30","doi-asserted-by":"crossref","first-page":"14315","DOI":"10.1038\/s41598-020-71080-0","volume":"10","author":"N Aldoj","year":"2020","unstructured":"Aldoj, N., Biavati, F., Michallek, F., Stober, S. & Dewey, M. Automatic prostate and prostate zones segmentation of magnetic resonance images using DenseNet-like U-net. Sci. Rep. 10(1), 14315 (2020).","journal-title":"Sci. Rep."},{"issue":"5","key":"95157_CR31","doi-asserted-by":"crossref","first-page":"2377","DOI":"10.1002\/mrm.28627","volume":"85","author":"A Manduca","year":"2021","unstructured":"Manduca, A. et al. MR elastography: principles, guidelines, and terminology. Magn. Reson. Med. 85(5), 2377\u20132390 (2021).","journal-title":"Magn. Reson. Med."},{"key":"95157_CR32","unstructured":"Lakshminarayanan, B., Pritzel, A. & Blundell, C. Simple and scalable predictive uncertainty Estimation using deep ensembles. Adv. Neural. Inf. Process. Syst. 30, 74 (2017)."},{"issue":"Suppl 1","key":"95157_CR33","doi-asserted-by":"crossref","first-page":"1513","DOI":"10.1007\/s10462-023-10562-9","volume":"56","author":"J Gawlikowski","year":"2023","unstructured":"Gawlikowski, J. et al. A survey of uncertainty in deep neural networks. Artif. Intell. Rev. 56(Suppl 1), 1513\u20131589 (2023).","journal-title":"Artif. Intell. Rev."},{"issue":"2","key":"95157_CR34","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo, T. K. & Li, M. Y. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 15(2), 155\u2013163 (2016).","journal-title":"J. Chiropr. Med."},{"issue":"8","key":"95157_CR35","doi-asserted-by":"crossref","first-page":"867","DOI":"10.3899\/jrheum.211115","volume":"49","author":"MG Heckman","year":"2022","unstructured":"Heckman, M. G., Davis, J. M. & Crowson, C. S. Post hoc power calculations: an inappropriate method for interpreting the findings of a research study. J. Rheumatol. 49(8), 867\u2013870 (2022).","journal-title":"J. Rheumatol."},{"key":"95157_CR36","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.neucom.2021.08.157","volume":"490","author":"N Altini","year":"2022","unstructured":"Altini, N. et al. Liver, kidney and spleen segmentation from CT scans and MRI with deep learning: A survey. Neurocomputing 490, 30\u201353 (2022).","journal-title":"Neurocomputing"},{"issue":"6","key":"95157_CR37","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1097\/RLI.0000000000000755","volume":"56","author":"T Kart","year":"2021","unstructured":"Kart, T. et al. Deep Learning-Based automated abdominal organ segmentation in the UK biobank and German National cohort magnetic resonance imaging studies. Invest. Radiol. 56(6), 401\u2013408 (2021).","journal-title":"Invest. Radiol."},{"key":"95157_CR38","doi-asserted-by":"crossref","first-page":"105620","DOI":"10.1016\/j.compbiomed.2022.105620","volume":"147","author":"S Gul","year":"2022","unstructured":"Gul, S. et al. Deep learning techniques for liver and liver tumor segmentation: a review. Comput. Biol. Med. 147, 105620 (2022).","journal-title":"Comput. Biol. Med."},{"issue":"2","key":"95157_CR39","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1109\/TBME.2017.2764752","volume":"65","author":"Y Huo","year":"2018","unstructured":"Huo, Y. et al. Robust multicontrast MRI spleen segmentation for splenomegaly using Multi-Atlas segmentation. IEEE Trans. Biomed. Eng. 65(2), 336\u2013343 (2018).","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"4","key":"95157_CR40","doi-asserted-by":"crossref","first-page":"950","DOI":"10.3390\/tomography7040078","volume":"7","author":"A Meddeb","year":"2021","unstructured":"Meddeb, A., Kossen, T., Bressem, K. K., Hamm, B. & Nagel, S. N. Evaluation of a deep learning algorithm for automated spleen segmentation in patients with conditions directly or indirectly affecting the spleen. Tomography 7(4), 950\u2013960 (2021).","journal-title":"Tomography"},{"key":"95157_CR41","doi-asserted-by":"crossref","unstructured":"Meddeb, A. et al. Two-Stage deep learning model for automated segmentation and classification of splenomegaly. Cancers (Basel) 14, 22  (2022).","DOI":"10.3390\/cancers14225476"},{"key":"95157_CR42","doi-asserted-by":"crossref","unstructured":"Du, G., Cao, X., Liang, J., Chen, X. & Zhan, Y. Medical image segmentation based on U-Net: a review. J. Imaging Sci. Technol. 64, 2 (2020).","DOI":"10.2352\/J.ImagingSci.Technol.2020.64.2.020508"},{"issue":"9","key":"95157_CR43","doi-asserted-by":"crossref","first-page":"1624","DOI":"10.3390\/diagnostics13091624","volume":"13","author":"R Yousef","year":"2023","unstructured":"Yousef, R. et al. U-Net-Based models towards optimal MR brain image segmentation. Diagnostics 13(9), 1624 (2023).","journal-title":"Diagnostics"},{"issue":"3","key":"95157_CR44","doi-asserted-by":"crossref","first-page":"867","DOI":"10.3390\/s22030867","volume":"22","author":"V Anand","year":"2022","unstructured":"Anand, V. et al. Modified U-net architecture for segmentation of skin lesion. Sensors 22(3), 867 (2022).","journal-title":"Sensors"},{"issue":"6","key":"95157_CR45","doi-asserted-by":"crossref","first-page":"712","DOI":"10.3390\/bioengineering10060712","volume":"10","author":"S Zhang","year":"2023","unstructured":"Zhang, S. & Niu, Y. LcmUNet: a lightweight network combining CNN and MLP for real-time medical image segmentation. Bioengineering 10(6), 712 (2023).","journal-title":"Bioengineering"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-95157-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-95157-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-95157-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,29]],"date-time":"2025-03-29T07:45:29Z","timestamp":1743234329000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-95157-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,28]]},"references-count":45,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["95157"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-95157-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,28]]},"assertion":[{"value":"10 August 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10762"}}