{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T20:37:31Z","timestamp":1790973451570,"version":"4.1.0"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T00:00:00Z","timestamp":1743120000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T00:00:00Z","timestamp":1743120000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Coagulation test results are influenced by many pre-analytical variables, including clinical sample storage conditions. This study investigated the effects of storage time and temperature on coagulation factor (FII, FV, FVII, FX, FVIII, FIX, FXI, FXII, and FXIII) and natural anticoagulant (antithrombin, protein C, and free protein S) activities. Blood samples were collected from 78 healthy individuals, and 3 samples were used for each coagulation factor and natural anticoagulant. Plasma was tested after centrifugation and storage at room temperature (18 to 25\u00a0\u00b0C) or refrigerated (2 to 8\u00a0\u00b0C) for 2, 3, 4, and 5\u00a0h, or frozen (\u2212 15 to \u2212 25\u00a0\u00b0C) for 1, 2, 3, and 4 months. For all storage conditions, the mean percentage change from baseline in evaluated activities was &lt;\u200915%, except for FV and FVIII. For FV activities after frozen storage at \u2212 15 to \u2212 25\u00a0\u00b0C and FVIII activities at all storage conditions, the mean percentage change was &gt;\u200915%. For FV and FVIII activities, the mean percentage change was &lt;\u200915% after frozen storage at \u2212 75 to \u2212 85\u00a0\u00b0C for 1, 2, 3, and 4 months. To ensure appropriate clinical testing results, especially for FV and FVIII activity, storage condition and time should be critically controlled.<\/jats:p>","DOI":"10.1038\/s41598-025-95389-w","type":"journal-article","created":{"date-parts":[[2025,3,29]],"date-time":"2025-03-29T09:41:36Z","timestamp":1743241296000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Effects of storage time and temperature on coagulation factor and natural anticoagulant activities in healthy individuals"],"prefix":"10.1038","volume":"15","author":[{"given":"Ryosuke","family":"Nakanishi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tasuku","family":"Sakayori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daichi","family":"Matsui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mai","family":"Kono","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minase","family":"Maki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claire","family":"Dunois","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yutaka","family":"Komiyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiromi","family":"Morisaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,28]]},"reference":[{"key":"95389_CR1","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1055\/s-0039-1692700","volume":"45","author":"RC Gosselin","year":"2019","unstructured":"Gosselin, R. C. & Marlar, R. A. Preanalytical variables in coagulation testing: setting the stage for accurate results. Semin. Thromb. Hemost. 45, 433\u2013448 (2019).","journal-title":"Semin. Thromb. Hemost."},{"key":"95389_CR2","doi-asserted-by":"publisher","first-page":"1315","DOI":"10.1016\/j.clinbiochem.2016.08.022","volume":"49","author":"DM Adcock","year":"2016","unstructured":"Adcock, D. M., Favaloro, E. J. & Lippi, G. Critical pre-examination variables in the hemostasis laboratory and their quality indicators. Clin. Biochem. 49, 1315\u20131320 (2016).","journal-title":"Clin. Biochem."},{"key":"95389_CR3","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1055\/s-0028-1104540","volume":"34","author":"EJ Favaloro","year":"2008","unstructured":"Favaloro, E. J., Lippi, G. & Adcock, D. M. Preanalytical and postanalytical variables: the leading causes of diagnostic error in hemostasis? Semin. Thromb. Hemost. 34, 612\u2013634 (2008).","journal-title":"Semin. Thromb. Hemost."},{"key":"95389_CR4","unstructured":"CLSI. Collection, Transport, and Processing of Blood Specimens for Testing Plasma-Based Coagulation Assays, 6th ed. CLSI document H21-ED6 Wayne (Clinical and Lab. Standards Inst., 2024)."},{"key":"95389_CR5","doi-asserted-by":"publisher","first-page":"3868","DOI":"10.1038\/srep03868","volume":"4","author":"L Feng","year":"2014","unstructured":"Feng, L., Zhao, Y., Zhao, H. & Shao, Z. Effects of storage time and temperature on coagulation tests and factors in fresh plasma. Sci. Rep. 4, 3868 (2014).","journal-title":"Sci. Rep."},{"key":"95389_CR6","doi-asserted-by":"publisher","first-page":"456","DOI":"10.21037\/atm.2018.11.24","volume":"6","author":"Y Zhao","year":"2018","unstructured":"Zhao, Y., Feng, G. & Feng, L. Effects of pre-analytical storage time, temperature, and freeze-thaw times on coagulation factors activities in citrate-anticoagulated plasma. Ann. Transl. Med. 6, 456 (2018).","journal-title":"Ann. Transl. Med."},{"key":"95389_CR7","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1097\/01.mbc.0000198990.16598.85","volume":"17","author":"M B\u00f6hm","year":"2006","unstructured":"B\u00f6hm, M. et al. Cold storage of citrated whole blood induces drastic time-dependent losses in factor VIII and von Willebrand factor: potential for misdiagnosis of haemophilia and von Willebrand disease. Blood Coagul. Fibrinolysis. 17, 39\u201345 (2006).","journal-title":"Blood Coagul. Fibrinolysis"},{"key":"95389_CR8","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1111\/ijlh.12784","volume":"40","author":"EA Linskens","year":"2018","unstructured":"Linskens, E. A. & Devreese, K. M. J. Pre-analytical stability of coagulation parameters in plasma stored at room temperature. Int. J. Lab. Hematol. 40, 292\u2013303 (2018).","journal-title":"Int. J. Lab. Hematol."},{"key":"95389_CR9","doi-asserted-by":"publisher","first-page":"12179","DOI":"10.1038\/s41598-017-11777-x","volume":"7","author":"Y Zhao","year":"2017","unstructured":"Zhao, Y. et al. Effects of preanalytical frozen storage time and temperature on screening coagulation tests and factors VIII and IX activity. Sci. Rep. 7, 12179 (2017).","journal-title":"Sci. Rep."},{"key":"95389_CR10","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1097\/00001721-200106000-00002","volume":"12","author":"B Woodhams","year":"2001","unstructured":"Woodhams, B., Girardot, O., Blanco, M. J., Colesse, G. & Gourmelin, Y. Stability of coagulation proteins in frozen plasma. Blood Coagul. Fibrinolysis. 12, 229\u2013236 (2001).","journal-title":"Blood Coagul Fibrinolysis"},{"key":"95389_CR11","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1007\/s12185-020-02983-x","volume":"112","author":"M Ieko","year":"2020","unstructured":"Ieko, M. et al. Expert consensus regarding standardization of sample preparation for clotting time assays. Int. J. Hematol. 112, 614\u2013620 (2020).","journal-title":"Int. J. Hematol."},{"key":"95389_CR12","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1097\/00001721-199809000-00002","volume":"9","author":"D Adcock","year":"1998","unstructured":"Adcock, D., Kressin, D. & Marlar, R. A. The effect of time and temperature variables on routine coagulation tests. Blood Coagul. Fibrinolysis. 9, 463\u2013470 (1998).","journal-title":"Blood Coagul. Fibrinolysis"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-95389-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-95389-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-95389-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,29]],"date-time":"2025-03-29T09:41:38Z","timestamp":1743241298000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-95389-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,28]]},"references-count":12,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["95389"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-95389-w","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-5314705\/v1","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,28]]},"assertion":[{"value":"23 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"R.N., T.S., D.M., M.K., M.M. and H.M. are employees of Sysmex Corporation. C.D. is an employee of HYPHEN BioMed. Y.K. is an outside adviser for Sysmex Corporation.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10797"}}