{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T14:38:10Z","timestamp":1792075090130,"version":"4.4.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T00:00:00Z","timestamp":1743120000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T00:00:00Z","timestamp":1743120000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100004329","name":"The Slovenian Research and Innovation Agency","doi-asserted-by":"publisher","award":["research core funding No. P2-0109"],"award-info":[{"award-number":["research core funding No. P2-0109"]}],"id":[{"id":"10.13039\/501100004329","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-025-95512-x","type":"journal-article","created":{"date-parts":[[2025,3,29]],"date-time":"2025-03-29T08:15:25Z","timestamp":1743236125000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Non-invasive and continuous intra-abdominal pressure assessment using MC sensors"],"prefix":"10.1038","volume":"15","author":[{"given":"Bo\u0161tjan","family":"Ple\u0161nik","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mihajlo","family":"Djoki\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Srdjan","family":"Djordjevi\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"Kra\u0161na","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"\u017dumer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bla\u017e","family":"Trotov\u0161ek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,28]]},"reference":[{"issue":"11","key":"95512_CR1","doi-asserted-by":"crossref","first-page":"1722","DOI":"10.1007\/s00134-006-0349-5","volume":"32","author":"ML Malbrain","year":"2006","unstructured":"Malbrain, M. L. et al. Results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. I. Definitions. J Intensive Care Med. 32(11), 1722\u20131732 (2006).","journal-title":"J Intensive Care Med."},{"issue":"9","key":"95512_CR2","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.clinbiomech.2010.06.018","volume":"25","author":"IAF Stokes","year":"2010","unstructured":"Stokes, I. A. F., Gardner-Morse, M. G. & Henry, S. M. Intra-abdominal pressure and abdominal wall muscular function: Spinal unloading mechanism. Clin. Biomech. (Bristol, Avon). 25(9), 859 (2010).","journal-title":"Clin. Biomech. (Bristol, Avon)."},{"issue":"1","key":"95512_CR3","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1016\/j.chest.2017.07.023","volume":"153","author":"WK Rogers","year":"2018","unstructured":"Rogers, W. K. & Garcia, L. Intraabdominal hypertension, abdominal compartment syndrome, and the open abdomen. Chest. 153(1), 238\u2013250 (2018).","journal-title":"Chest."},{"issue":"7","key":"95512_CR4","doi-asserted-by":"crossref","first-page":"1190","DOI":"10.1007\/s00134-013-2906-z","volume":"39","author":"AW Kirkpatrick","year":"2013","unstructured":"Kirkpatrick, A. W. et al. Intra-abdominal hypertension and the abdominal compartment syndrome: Updated consensus definitions and clinical practice guidelines from the World Society of the Abdominal Compartment Syndrome. Intensive Care Med. 39(7), 1190 (2013).","journal-title":"Intensive Care Med."},{"issue":"4","key":"95512_CR5","doi-asserted-by":"crossref","first-page":"330","DOI":"10.4240\/wjgs.v13.i4.330","volume":"13","author":"M Leon","year":"2021","unstructured":"Leon, M., Chavez, L. & Surani, S. Abdominal compartment syndrome among surgical patients. World J. Gastrointest. Surg. 13(4), 330 (2021).","journal-title":"World J. Gastrointest. Surg."},{"issue":"4","key":"95512_CR6","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1097\/00005373-200010000-00008","volume":"49","author":"ML Cheatham","year":"2000","unstructured":"Cheatham, M. L. et al. Abdominal perfusion pressure: A superior parameter in the assessment of intra-abdominal hypertension. J. Trauma 49(4), 621\u2013627 (2000).","journal-title":"J. Trauma"},{"key":"95512_CR7","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1186\/1757-7241-17-10","volume":"17","author":"ML Cheatham","year":"2009","unstructured":"Cheatham, M. L. Abdominal compartment syndrome: Pathophysiology and definitions. Scand. J. Trauma Resusc. Emerg. Med. 17, 10 (2009).","journal-title":"Scand. J. Trauma Resusc. Emerg. Med."},{"issue":"6","key":"95512_CR8","doi-asserted-by":"crossref","first-page":"1747","DOI":"10.1097\/00003246-200006000-00008","volume":"28","author":"W Ertel","year":"2000","unstructured":"Ertel, W., Oberholzer, A., Platz, A., Stocker, R. & Trentz, O. Incidence and clinical pattern of the abdominal compartment syndrome after \u201cdamage-control\u201d laparotomy in 311 patients with severe abdominal and\/or pelvic trauma. Crit. Care Med. 28(6), 1747\u201353 (2000).","journal-title":"Crit. Care Med."},{"issue":"4","key":"95512_CR9","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1097\/00075198-200108000-00010","volume":"7","author":"J Morken","year":"2001","unstructured":"Morken, J. & West, M. A. Abdominal compartment syndrome in the intensive care unit. Curr Opin. Crit Care 7(4), 268\u2013274 (2001).","journal-title":"Curr Opin. Crit Care"},{"issue":"1","key":"95512_CR10","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.ccm.2008.09.003","volume":"30","author":"MLNG Malbrain","year":"2009","unstructured":"Malbrain, M. L. N. G. & De laet, I. E. Intra-abdominal hypertension: Evolving concepts. Clin. Chest Med. 30(1), 45\u201370 (2009).","journal-title":"Clin. Chest Med."},{"issue":"4","key":"95512_CR11","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1097\/CCM.0000000000003623","volume":"47","author":"A Reintam Blaser","year":"2019","unstructured":"Reintam Blaser, A. et al. Incidence, risk factors, and outcomes of intra-abdominal hypertension in critically Ill patients\u2014A prospective multicenter study (IROI Study). Crit. Care Med. 47(4), 535 (2019).","journal-title":"Crit. Care Med."},{"issue":"1","key":"95512_CR12","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1007\/s00423-015-1353-4","volume":"401","author":"A Hecker","year":"2016","unstructured":"Hecker, A. et al. Acute abdominal compartment syndrome: Current diagnostic and therapeutic options. Langenbeck\u2019s Arch. Surg. 401(1), 15\u201324 (2016).","journal-title":"Langenbeck\u2019s Arch. Surg."},{"issue":"1","key":"95512_CR13","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1016\/j.chest.2017.07.023","volume":"153","author":"WK Rogers","year":"2018","unstructured":"Rogers, W. K. & Garcia, L. Intraabdominal hypertension, abdominal compartment syndrome, and the open abdomen. Chest 153(1), 238\u2013250 (2018).","journal-title":"Chest"},{"issue":"14","key":"95512_CR14","doi-asserted-by":"crossref","first-page":"4824","DOI":"10.3390\/s21144824","volume":"21","author":"CH Liao","year":"2021","unstructured":"Liao, C. H. et al. Systematic review of diagnostic sensors for intra-abdominal pressure monitoring. Sensors 21(14), 4824 (2021).","journal-title":"Sensors"},{"issue":"7","key":"95512_CR15","doi-asserted-by":"crossref","first-page":"1190","DOI":"10.1007\/s00134-013-2906-z","volume":"39","author":"AW Kirkpatrick","year":"2013","unstructured":"Kirkpatrick, A. W. et al. Intra-abdominal hypertension and the abdominal compartment syndrome: Updated consensus definitions and clinical practice guidelines from the World Society of the Abdominal Compartment Syndrome. Intensive Care Med 39(7), 1190 (2013).","journal-title":"Intensive Care Med"},{"issue":"4","key":"95512_CR16","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1007\/s00134-001-1187-0","volume":"28","author":"F Gudmundsson","year":"2002","unstructured":"Gudmundsson, F., Viste, A., Gislason, H. & Svanes, K. Comparison of different methods for measuring intra-abdominal pressure. Intensive Care Med. 28(4), 509\u2013514 (2002).","journal-title":"Intensive Care Med."},{"issue":"10","key":"95512_CR17","doi-asserted-by":"crossref","first-page":"9411","DOI":"10.3390\/s111009411","volume":"11","author":"S Dordevi\u0107","year":"2011","unstructured":"Dordevi\u0107, S., Stan\u010din, S., Megli\u010d, A., Milutinovi\u0107, V. & Toma\u017ei\u010d, S. MC sensor: A novel method for measurement of muscle tension. Sensors (Basel) 11(10), 9411\u20139425 (2011).","journal-title":"Sensors (Basel)"},{"issue":"9","key":"95512_CR18","doi-asserted-by":"crossref","first-page":"2108","DOI":"10.3390\/s19092108","volume":"19","author":"A Megli\u010d","year":"2019","unstructured":"Megli\u010d, A., Ur\u0161i\u010d, M., \u0160korjanc, A., \u0110or\u0111evi\u0107, S. & Belu\u0161i\u010d, G. The Piezo-resistive MC sensor is a fast and accurate sensor for the measurement of mechanical muscle activity. Sensors (Basel). 19(9), 2108 (2019).","journal-title":"Sensors (Basel)."},{"issue":"9","key":"95512_CR19","doi-asserted-by":"crossref","first-page":"17848","DOI":"10.3390\/s140917848","volume":"14","author":"S \u0110or\u0111evi\u0107","year":"2014","unstructured":"\u0110or\u0111evi\u0107, S., Toma\u017ei\u010d, S., Narici, M., Pi\u0161ot, R. & Megli\u010d, A. In-vivo measurement of muscle tension: Dynamic properties of the MC sensor during isometric muscle contraction. Sensors (Basel). 14(9), 17848\u201317863 (2014).","journal-title":"Sensors (Basel)."},{"key":"95512_CR20","doi-asserted-by":"crossref","unstructured":"Ku\u0161ar, M., Djoki\u0107, M., Djordjevi\u0107, S., Hribernik, M., Kra\u0161na, S. & Trotov\u0161ek, B. Preliminary study of reliability of transcutaneous sensors in measuring intraabdominal pressure. Sci. Rep. 12(1). Available from https:\/\/pubmed.ncbi.nlm.nih.gov\/35585106\/ (2022).","DOI":"10.1038\/s41598-022-12388-x"},{"issue":"3","key":"95512_CR21","doi-asserted-by":"crossref","first-page":"241","DOI":"10.5603\/AIT.a2015.0025","volume":"47","author":"M Sugrue","year":"2015","unstructured":"Sugrue, M., De Waele, J. J., De Keulenaer, B. L., Roberts, D. J. & Malbrain, M. L. N. G. A user\u2019s guide to intra-abdominal pressure measurement. Anaesthesiol. Intensive Ther. 47(3), 241\u2013251 (2015).","journal-title":"Anaesthesiol. Intensive Ther."},{"key":"95512_CR22","doi-asserted-by":"crossref","unstructured":"Regli, A., Pelosi, P. & Malbrain, MLNG. Ventilation in patients with intra-abdominal hypertension: What every critical care physician needs to know. Ann. Intensive Care 9(1).","DOI":"10.1186\/s13613-019-0522-y"},{"issue":"10","key":"95512_CR23","doi-asserted-by":"crossref","first-page":"1501","DOI":"10.1007\/s00134-022-06780-4","volume":"48","author":"MLNG Malbrain","year":"2022","unstructured":"Malbrain, M. L. N. G., De Keulenaer, B. L. & Khanna, A. K. Continuous intra-abdominal pressure: Is it ready for prime time?. Intensive Care Med. 48(10), 1501 (2022).","journal-title":"Intensive Care Med."},{"issue":"10","key":"95512_CR24","doi-asserted-by":"crossref","first-page":"3005","DOI":"10.12998\/wjcc.v10.i10.3005","volume":"10","author":"P \u0141agosz","year":"2022","unstructured":"\u0141agosz, P., Sokolski, M., Biegus, J., Tycinska, A. & Zymlinski, R. Elevated intra-abdominal pressure: A review of current knowledge. World J. Clin. Cases 10(10), 3005 (2022).","journal-title":"World J. Clin. Cases"},{"issue":"3","key":"95512_CR25","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1007\/s00134-003-2107-2","volume":"30","author":"MLNG Malbrain","year":"2004","unstructured":"Malbrain, M. L. N. G. Different techniques to measure intra-abdominal pressure (IAP): Time for a critical re-appraisal. Intensive Care Med. 30(3), 357\u2013371 (2004).","journal-title":"Intensive Care Med."},{"issue":"1","key":"95512_CR26","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.jmig.2006.06.025","volume":"14","author":"VR Jacobs","year":"2007","unstructured":"Jacobs, V. R. & Morrison, J. E. The real intraabdominal pressure during laparoscopy: Comparison of different insufflators. J. Minim. Invasive Gynecol. 14(1), 103\u2013107 (2007).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"95512_CR27","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1007\/978-3-031-61628-0_18","volume":"113","author":"J Wacker","year":"2024","unstructured":"Wacker, J. et al. Non-invasive continuous measurement of the intra-abdominal pressure. EMBEC 2024. IFMBE Proc. 113, 160\u2013168. https:\/\/doi.org\/10.1007\/978-3-031-61628-0_18 (2024).","journal-title":"IFMBE Proc."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-95512-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-95512-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-95512-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,29]],"date-time":"2025-03-29T08:16:17Z","timestamp":1743236177000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-95512-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,28]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["95512"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-95512-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,28]]},"assertion":[{"value":"14 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10775"}}