{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T18:27:28Z","timestamp":1759775248849,"version":"3.40.4"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T00:00:00Z","timestamp":1744848000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T00:00:00Z","timestamp":1744848000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Ulm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>The refractive accuracy of intraocular lens (IOL) formulas varies in eyes that undergo combined phacovitrectomy for different underlying vitreoretinal pathology. A total of 401 eyes that underwent uncomplicated phacovitrectomy (23\u201325\u00a0g) with implantation of a plate haptic IOL (CT Asphina 409\u00a0M) in the capsular bag between April 2020 and December 2022 were included in the study. Inclusion criteria were postoperative best corrected visual acuity of 0.4 LogMAR or better at least 8 weeks after surgery. The Barrett Universal II (BUII), Haigis, Hill-Radial Basis Function (Hill-RBFv3.0), Hoffer Q, Holladay I, Holladay II, Kane, K6, Pearl-DGS and SRK\/T formulas were compared for their accuracy in mean absolute error (MAE). Furthermore, all formulas were additionally tested by using the prediction for an IOL power 0,5 or 1D above the IOL used (IOLdown). Wilcox-Holladay-Wang-Koch (WHWK) statistical tests with Holm correction were applied. The Barrett IOLdown formula showed the lowest refractive prediction error (0.03D; together with Hill IOLdown), lowest MAE (0.40D), lowest median absolute error (MedAE; 0.31D), lowest standard deviation of MAE (0.55D) and lowest root mean squared absolute error (RMSAE; 0,54D). Barrett IOLdown had the highest percentage of eyes with predicted error within \u00b1\u20090.25D (41.6%), Kane IOLdown within \u00b1\u20090.50D (70.5%) and \u00b1\u20090.75D (89%) and Hill IOLdown within \u00b1\u20091D (95.2%). Except for Haigis, Hoffer Q and Pearl-DGS, all other formulas showed a statistically significantly lower MAE after IOLdown modification. The newest formulas with IOLdown modification performed better than old generation formulas, with Barrett IOLdown exhibiting the best results.<\/jats:p>","DOI":"10.1038\/s41598-025-97839-x","type":"journal-article","created":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T13:09:36Z","timestamp":1744895376000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparison of 10 biometric formulas in combined phacovitrectomy for different underlying retinal pathology"],"prefix":"10.1038","volume":"15","author":[{"given":"Eleftherios","family":"Chatzimichail","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David L.","family":"Cooke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Wertheimer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Susanna","family":"Koenig","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zisis","family":"Gatzioufas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Armin","family":"Wolf","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Efstathios","family":"Vounotrypidis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,4,17]]},"reference":[{"key":"97839_CR1","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1097\/j.jcrs.0000000000000087","volume":"46","author":"E Vounotrypidis","year":"2020","unstructured":"Vounotrypidis, E. et al. Refractive outcomes of 8 biometric formulas in combined phacovitrectomy with internal limiting membrane peeling for epiretinal membrane. J. Cataract Refract. Surg. 46, 591\u2013597. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000087 (2020).","journal-title":"J. Cataract Refract. Surg."},{"key":"97839_CR2","doi-asserted-by":"publisher","first-page":"322","DOI":"10.3341\/kjo.2023.0012","volume":"37","author":"YJ Choi","year":"2023","unstructured":"Choi, Y. J. & Jee, D. Postoperative refractive outcomes of biometric formulas in phacovitrectomy with gas tamponade. Korean J. Ophthalmol. 37, 322\u2013327. https:\/\/doi.org\/10.3341\/kjo.2023.0012 (2023).","journal-title":"Korean J. Ophthalmol."},{"key":"97839_CR3","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1097\/j.jcrs.0000000000001106","volume":"49","author":"A Khan","year":"2023","unstructured":"Khan, A. et al. Standard vs total keratometry for intraocular lens power calculation in cataract surgery combined with DMEK. J. Cataract Refract. Surg. 49, 239\u2013245. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001106 (2023).","journal-title":"J. Cataract Refract. Surg."},{"key":"97839_CR4","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1080\/02713683.2024.2305780","volume":"49","author":"N Rangu","year":"2024","unstructured":"Rangu, N. et al. Comparison of Pre- and Post-DMEK keratometry and total keratometry values for IOL power calculations in eyes undergoing triple DMEK. Curr. Eye Res. 49, 477\u2013486. https:\/\/doi.org\/10.1080\/02713683.2024.2305780 (2024).","journal-title":"Curr. Eye Res."},{"key":"97839_CR5","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.ajo.2020.04.035","volume":"217","author":"X Tan","year":"2020","unstructured":"Tan, X. et al. Accuracy of new generation intraocular lens calculation formulas in vitrectomized eyes. Am. J. Ophthalmol. 217, 81\u201390. https:\/\/doi.org\/10.1016\/j.ajo.2020.04.035 (2020).","journal-title":"Am. J. Ophthalmol."},{"key":"97839_CR6","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.ajo.2024.03.014","volume":"264","author":"AM Anter","year":"2024","unstructured":"Anter, A. M. et al. Comparison of legacy and new No-History IOL power calculation formulas in postmyopic laser vision correction eyes. Am. J. Ophthalmol. 264, 44\u201352. https:\/\/doi.org\/10.1016\/j.ajo.2024.03.014 (2024).","journal-title":"Am. J. Ophthalmol."},{"key":"97839_CR7","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1097\/j.jcrs.0000000000001508","volume":"50","author":"HJ Shammas","year":"2024","unstructured":"Shammas, H. J. et al. Updating the no-history method in intraocular lens power calculation after myopic laser vision correction. J. Cataract Refract. Surg. 50, 1026\u20131029. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001508 (2024).","journal-title":"J. Cataract Refract. Surg."},{"key":"97839_CR8","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.jcrs.2018.08.027","volume":"45","author":"E Vounotrypidis","year":"2019","unstructured":"Vounotrypidis, E. et al. Accuracy of SS-OCT biometry compared with partial coherence interferometry biometry for combined phacovitrectomy with internal limiting membrane peeling. J. Cataract Refract. Surg. 45, 48\u201353. https:\/\/doi.org\/10.1016\/j.jcrs.2018.08.027 (2019).","journal-title":"J. Cataract Refract. Surg."},{"key":"97839_CR9","doi-asserted-by":"publisher","first-page":"2197","DOI":"10.1007\/s40123-024-00971-6","volume":"13","author":"Y Tanaka","year":"2024","unstructured":"Tanaka, Y. et al. Evaluation of the accuracy of intraocular lens power calculation formulas in phacovitrectomy. Ophthalmol. Ther. 13, 2197\u20132208. https:\/\/doi.org\/10.1007\/s40123-024-00971-6 (2024).","journal-title":"Ophthalmol. Ther."},{"key":"97839_CR10","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/j.ophtha.2019.10.021","volume":"127","author":"N Shiraki","year":"2020","unstructured":"Shiraki, N., Wakabayashi, T., Sakaguchi, H. & Nishida, K. Effect of gas tamponade on the intraocular lens position and refractive error after phacovitrectomy: A Swept-Source anterior segment OCT analysis. Ophthalmology 127, 511\u2013515. https:\/\/doi.org\/10.1016\/j.ophtha.2019.10.021 (2020).","journal-title":"Ophthalmology"},{"key":"97839_CR11","doi-asserted-by":"publisher","first-page":"e1518","DOI":"10.1111\/aos.15192","volume":"100","author":"CF Mayer-Xanthaki","year":"2022","unstructured":"Mayer-Xanthaki, C. F. et al. Influence of combined phacovitrectomy without tamponade on intraocular lens displacement and postoperative refraction. Acta Ophthalmol. 100, e1518\u2013e1521. https:\/\/doi.org\/10.1111\/aos.15192 (2022).","journal-title":"Acta Ophthalmol."},{"key":"97839_CR12","doi-asserted-by":"publisher","first-page":"864","DOI":"10.1097\/j.jcrs.0000000000001228","volume":"49","author":"E Chatzimichail","year":"2023","unstructured":"Chatzimichail, E. et al. Influence of endotamponade on anterior chamber depth and refractive outcome after combined phacovitrectomy: case-control study. J. Cataract Refract. Surg. 49, 864\u2013868. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001228 (2023).","journal-title":"J. Cataract Refract. Surg."},{"key":"97839_CR13","doi-asserted-by":"publisher","unstructured":"Hipolito-Fernandes, D. et al. Intraocular lens power calculation formulas accuracy in combined phacovitrectomy: an 8-formulas comparison study. Int. J. Retina Vitreous. 7 https:\/\/doi.org\/10.1186\/s40942-021-00315-7 (2021).","DOI":"10.1186\/s40942-021-00315-7"},{"key":"97839_CR14","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1007\/s10792-024-03019-7","volume":"44","author":"C Thanitcul","year":"2024","unstructured":"Thanitcul, C. et al. Accuracy of intraocular lens formulas in combined phacovitrectomy. Int. Ophthalmol. 44, 96. https:\/\/doi.org\/10.1007\/s10792-024-03019-7 (2024).","journal-title":"Int. Ophthalmol."},{"key":"97839_CR15","doi-asserted-by":"publisher","first-page":"e354","DOI":"10.3928\/1081597X-20240422-01","volume":"40","author":"X Rong","year":"2024","unstructured":"Rong, X. et al. Accuracy of 12 intraocular lens power formulas after corneal myopic refractive surgery. J. Refract. Surg. 40, e354\u2013e361. https:\/\/doi.org\/10.3928\/1081597X-20240422-01 (2024).","journal-title":"J. Refract. Surg."},{"key":"97839_CR16","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.ajo.2023.09.026","volume":"262","author":"X Pan","year":"2024","unstructured":"Pan, X., Wang, Y., Li, Z. & Ye, Z. Intraocular lens power calculation in eyes after myopic laser refractive surgery and radial keratotomy: bayesian network Meta-analysis. Am. J. Ophthalmol. 262, 48\u201361. https:\/\/doi.org\/10.1016\/j.ajo.2023.09.026 (2024).","journal-title":"Am. J. Ophthalmol."},{"key":"97839_CR17","doi-asserted-by":"publisher","first-page":"251584142211185","DOI":"10.1177\/25158414221118524","volume":"14","author":"P Anders","year":"2022","unstructured":"Anders, P. et al. Intraocular lens power calculation in eyes with previous corneal refractive surgery. Ther. Adv. Ophthalmol. 14, 25158414221118524. https:\/\/doi.org\/10.1177\/25158414221118524 (2022).","journal-title":"Ther. Adv. Ophthalmol."},{"key":"97839_CR18","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1186\/s12886-023-03164-0","volume":"23","author":"L Li","year":"2023","unstructured":"Li, L. et al. Comparative analysis of IOL power calculations in postoperative refractive surgery patients: a theoretical surgical model for FS-LASIK and SMILE procedures. BMC Ophthalmol. 23, 416. https:\/\/doi.org\/10.1186\/s12886-023-03164-0 (2023).","journal-title":"BMC Ophthalmol."},{"key":"97839_CR19","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1007\/s00417-003-0672-2","volume":"242","author":"BA Lege","year":"2004","unstructured":"Lege, B. A. & Haigis, W. Laser interference biometry versus ultrasound biometry in certain clinical conditions. Graefes Arch. Clin. Exp. Ophthalmol. 242, 8\u201312. https:\/\/doi.org\/10.1007\/s00417-003-0672-2 (2004).","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"97839_CR20","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1159\/000060791","volume":"34","author":"W Haigis","year":"2002","unstructured":"Haigis, W. Optical coherence biometry. Dev. Ophthalmol. 34, 119\u2013130. https:\/\/doi.org\/10.1159\/000060791 (2002).","journal-title":"Dev. Ophthalmol."},{"key":"97839_CR21","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1111\/j.1600-0420.2007.00879.x","volume":"85","author":"T Olsen","year":"2007","unstructured":"Olsen, T. Calculation of intraocular lens power: a review. Acta Ophthalmol. Scand. 85, 472\u2013485. https:\/\/doi.org\/10.1111\/j.1600-0420.2007.00879.x (2007).","journal-title":"Acta Ophthalmol. Scand."},{"key":"97839_CR22","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.jcrs.2007.10.031","volume":"34","author":"S Norrby","year":"2008","unstructured":"Norrby, S. Sources of error in intraocular lens power calculation. J. Cataract Refract. Surg. 34, 368\u2013376. https:\/\/doi.org\/10.1016\/j.jcrs.2007.10.031 (2008).","journal-title":"J. Cataract Refract. Surg."},{"key":"97839_CR23","doi-asserted-by":"publisher","first-page":"1068","DOI":"10.1016\/j.jcrs.2017.06.034","volume":"43","author":"ZE Ercan","year":"2017","unstructured":"Ercan, Z. E., Akkoyun, I., Yaman Pinarci, E., Yilmaz, G. & Topcu, H. Refractive outcome comparison between vitreomacular interface disorders after phacovitrectomy. J. Cataract Refract. Surg. 43, 1068\u20131071. https:\/\/doi.org\/10.1016\/j.jcrs.2017.06.034 (2017).","journal-title":"J. Cataract Refract. Surg."},{"key":"97839_CR24","unstructured":"Con, I. O. L. Accessed January 31st. Intraocular lenses."},{"key":"97839_CR25","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1097\/j.jcrs.0000000000001165","volume":"49","author":"JT Holladay","year":"2023","unstructured":"Holladay, J. T., Wilcox, R. R., Koch, D. D. & Wang, L. Statistics of prediction error for non-Gaussian dependent and independent datasets. J. Cataract Refract. Surg. 49, 440\u2013442. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001165 (2023).","journal-title":"J. Cataract Refract. Surg."},{"key":"97839_CR26","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2025.01.022","author":"NT Cannon","year":"2025","unstructured":"Cannon, N. T. et al. Which test is best: evaluation of traditional and contemporary statistical tests for analysis of spherical equivalent prediction error. Am. J. Ophthalmol. https:\/\/doi.org\/10.1016\/j.ajo.2025.01.022 (2025).","journal-title":"Am. J. Ophthalmol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-97839-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-97839-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-97839-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T13:09:38Z","timestamp":1744895378000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-97839-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,17]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["97839"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-97839-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,17]]},"assertion":[{"value":"11 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All authors declare that no funds, grants, or other support was received for this work. All authors certify that they have no affiliations with -or involvement in- any organization or entity with any financial interest or non-financial interest in the subject matter or materials discussed in this manuscript. Eleftherios Chatzimichail, Christian Wertheimer, Susanna Koenig and Zisis Gatzioufas declare that they have no financial interests. Efstathios Vounotrypidis receives speaker honoraria, travel grants or research funding from Alcon, Bayer and Roche. Armin Wolf receives fees for lectures\/consulting or research funding from Novartis Pharma GmbH; Bayer Healthcare AG; Alimera; Allergan; Oertli Instrumente AG; Roche and Appellis.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"13313"}}