{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T09:43:18Z","timestamp":1789551798374,"version":"build-2803163510"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T00:00:00Z","timestamp":1747094400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T00:00:00Z","timestamp":1747094400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Elevated blood metal ion levels have been reported in patients following instrumented spinal fusion. However, the relationship between blood metal ion levels and clinical and radiographic outcomes remains elusive. The purpose of this study was to compare blood metal ion levels in patients with scoliosis undergoing corrective fusion surgery utilizing either cobalt-chromium (CoCr) or titanium (Ti) alloy rods, as well as preoperative scoliosis patients. Additionally, we investigated patient- and surgery-related factors associated with blood metal ion levels. This retrospective cohort study included 59 patients with CoCr rods (CoCr group), 29 patients with Ti alloy rods (Ti group), and 17 preoperative patients (control group). Blood samples were collected at a mean of 63\u00a0months postoperatively for the CoCr group and 113\u00a0months postoperatively for the Ti group. Blood levels of Co, Cr, and Ti were measured by inductively coupled plasma mass spectrometry. Blood Co levels were significantly elevated in the CoCr group compared to the control group (p\u2009=\u20090.021), with no significant difference observed between the CoCr and Ti groups (CoCr group: 0.28\u00a0\u03bcg\/L, Ti group: 0.21\u00a0\u03bcg\/L, control group: 0.20\u00a0\u03bcg\/L). However, blood Cr and Ti levels were found to be below the limit of quantification in all 105 individuals. Furthermore, a significant negative correlation was observed between blood Co levels and the postoperative follow-up duration. These findings underscore the medium-term safety rather than the concerns regarding blood metal ion levels following corrective fusion for scoliosis; however, prolonged and meticulous follow-up is imperative.<\/jats:p>","DOI":"10.1038\/s41598-025-99065-x","type":"journal-article","created":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T08:34:24Z","timestamp":1747125264000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Comparison of blood metal ion levels in scoliosis patients following instrumented spinal fusion with cobalt-chromium and titanium alloy rods"],"prefix":"10.1038","volume":"15","author":[{"given":"Shota","family":"Tamagawa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidetoshi","family":"Nojiri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tatsuya","family":"Sato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takehisa","family":"Matsukawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasuhiro","family":"Homma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiromitsu","family":"Takano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muneaki","family":"Ishijima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,13]]},"reference":[{"key":"99065_CR1","doi-asserted-by":"publisher","first-page":"448","DOI":"10.2106\/jbjs.M.00164","volume":"96","author":"CA Engh","year":"2014","unstructured":"Engh, C. A. et al. Metal ion levels after metal-on-metal total hip arthroplasty: a five-year, prospective randomized trial. J. Bone Joint Surg. Am. 96, 448\u2013455. https:\/\/doi.org\/10.2106\/jbjs.M.00164 (2014).","journal-title":"J. Bone Joint Surg. Am."},{"key":"99065_CR2","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.1007\/s00402-017-2723-x","volume":"137","author":"G Grammatopoulos","year":"2017","unstructured":"Grammatopoulos, G., Munemoto, M., Pollalis, A. & Athanasou, N. A. Correlation of serum metal ion levels with pathological changes of ARMD in failed metal-on-metal-hip-resurfacing arthroplasties. Arch. Orthop. Trauma Surg. 137, 1129\u20131137. https:\/\/doi.org\/10.1007\/s00402-017-2723-x (2017).","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"99065_CR3","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181d53724","author":"TP Cundy","year":"2010","unstructured":"Cundy, T. P. et al. Chromium ion release from stainless steel pediatric scoliosis instrumentation. Spine (Phila Pa 1976) https:\/\/doi.org\/10.1097\/BRS.0b013e3181d53724 (2010).","journal-title":"Spine (Phila Pa 1976)"},{"key":"99065_CR4","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181d7a197","author":"MD Rackham","year":"2010","unstructured":"Rackham, M. D. et al. Predictors of serum chromium levels after stainless steel posterior spinal instrumentation for adolescent idiopathic scoliosis. Spine (Phila Pa 1976) https:\/\/doi.org\/10.1097\/BRS.0b013e3181d7a197 (2010).","journal-title":"Spine (Phila Pa 1976)"},{"key":"99065_CR5","doi-asserted-by":"publisher","first-page":"3036","DOI":"10.1007\/s00586-022-07341-5","volume":"31","author":"D Fell","year":"2022","unstructured":"Fell, D., Diarbakerli, E. & Gerdhem, P. Serum metal ion levels following spinal deformity surgery: a case-control study of 182 individuals. Eur. Spine J. 31, 3036\u20133041. https:\/\/doi.org\/10.1007\/s00586-022-07341-5 (2022).","journal-title":"Eur. Spine J."},{"issue":"Suppl 2","key":"99065_CR6","doi-asserted-by":"publisher","first-page":"99","DOI":"10.2106\/jbjs.F.00102","volume":"88","author":"JJ Jacobs","year":"2006","unstructured":"Jacobs, J. J., Hallab, N. J., Urban, R. M. & Wimmer, M. A. Wear particles. J. Bone Joint Surg. Am. 88(Suppl 2), 99\u2013102. https:\/\/doi.org\/10.2106\/jbjs.F.00102 (2006).","journal-title":"J. Bone Joint Surg. Am."},{"key":"99065_CR7","doi-asserted-by":"publisher","first-page":"268","DOI":"10.2106\/00004623-199802000-00015","volume":"80","author":"JJ Jacobs","year":"1998","unstructured":"Jacobs, J. J., Gilbert, J. L. & Urban, R. M. Current concepts review-corrosion of metal orthopaedic implants. JBJS 80, 268\u2013282 (1998).","journal-title":"JBJS"},{"key":"99065_CR8","doi-asserted-by":"publisher","first-page":"2147","DOI":"10.1002\/jbm.a.34122","volume":"100","author":"A Dalal","year":"2012","unstructured":"Dalal, A., Pawar, V., McAllister, K., Weaver, C. & Hallab, N. J. Orthopedic implant cobalt-alloy particles produce greater toxicity and inflammatory cytokines than titanium alloy and zirconium alloy-based particles in vitro, in human osteoblasts, fibroblasts, and macrophages. J. Biomed. Mater. Res. A 100, 2147\u20132158. https:\/\/doi.org\/10.1002\/jbm.a.34122 (2012).","journal-title":"J. Biomed. Mater. Res. A"},{"key":"99065_CR9","doi-asserted-by":"publisher","first-page":"S30","DOI":"10.1097\/brs.0000000000001436","volume":"41","author":"NJ Hallab","year":"2016","unstructured":"Hallab, N. J. Biologic responses to orthopedic implants: Innate and adaptive immune responses to implant debris. Spine 41, S30\u2013S31. https:\/\/doi.org\/10.1097\/brs.0000000000001436 (2016).","journal-title":"Spine"},{"key":"99065_CR10","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s40883-021-00222-1","volume":"7","author":"CC Ude","year":"2021","unstructured":"Ude, C. C. et al. The mechanism of metallosis after total hip arthroplasty. Regen. Eng. Transl. Med. 7, 247\u2013261. https:\/\/doi.org\/10.1007\/s40883-021-00222-1 (2021).","journal-title":"Regen. Eng. Transl. Med."},{"key":"99065_CR11","doi-asserted-by":"publisher","first-page":"78","DOI":"10.5435\/jaaos-d-19-00860","volume":"29","author":"G Kelmer","year":"2021","unstructured":"Kelmer, G., Stone, A. H., Turcotte, J. & King, P. J. Reasons for revision: Primary total hip arthroplasty mechanisms of failure. J. Am. Acad. Orthop. Surg. 29, 78\u201387. https:\/\/doi.org\/10.5435\/jaaos-d-19-00860 (2021).","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"99065_CR12","doi-asserted-by":"publisher","first-page":"1791","DOI":"10.1007\/s00402-020-03560-x","volume":"140","author":"I Sahan","year":"2020","unstructured":"Sahan, I. & Anagnostakos, K. Metallosis after knee replacement: a review. Arch. Orthop. Trauma Surg. 140, 1791\u20131808. https:\/\/doi.org\/10.1007\/s00402-020-03560-x (2020).","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"99065_CR13","doi-asserted-by":"publisher","first-page":"752","DOI":"10.21037\/jss-20-492","volume":"6","author":"M-J Reisener","year":"2020","unstructured":"Reisener, M.-J., Pumberger, M., Shue, J., Girardi, F. P. & Hughes, A. P. Trends in lumbar spinal fusion\u2014a literature review. J. Spine Surg. 6, 752 (2020).","journal-title":"J. Spine Surg."},{"key":"99065_CR14","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1007\/s43390-020-00177-3","volume":"9","author":"O Siddiqi","year":"2021","unstructured":"Siddiqi, O., Urquhart, J. C. & Rasoulinejad, P. A systematic review of metal ion concentrations following instrumented spinal fusion. Spine Deform. 9, 13\u201340. https:\/\/doi.org\/10.1007\/s43390-020-00177-3 (2021).","journal-title":"Spine Deform."},{"key":"99065_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2024.02.019","author":"J Burgos","year":"2024","unstructured":"Burgos, J. et al. Elevated blood metal ion levels in patients undergoing instrumented spinal surgery: A systematic review and meta-analysis. Spine J. https:\/\/doi.org\/10.1016\/j.spinee.2024.02.019 (2024).","journal-title":"Spine J."},{"key":"99065_CR16","doi-asserted-by":"publisher","first-page":"2205","DOI":"10.1007\/s00264-022-05502-1","volume":"46","author":"S Ishii","year":"2022","unstructured":"Ishii, S. et al. Blood cobalt ion level in patients with different sizes of cobalt\/chrome femoral head with the Accolade TMZF stem. Int. Orthop. 46, 2205\u20132212. https:\/\/doi.org\/10.1007\/s00264-022-05502-1 (2022).","journal-title":"Int. Orthop."},{"key":"99065_CR17","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.1007\/s43390-021-00365-9","volume":"9","author":"ST S\u00f8rensen","year":"2021","unstructured":"S\u00f8rensen, S. T., Schmedes, A. V., Andersen, M., Carreon, L. & Simony, A. Serum metal ion levels in adolescent idiopathic scoliosis (AIS) patients 25 years after treated with Harrington rod instrumentation or bracing. Spine Deform. 9, 1519\u20131523. https:\/\/doi.org\/10.1007\/s43390-021-00365-9 (2021).","journal-title":"Spine Deform."},{"key":"99065_CR18","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1097\/brs.0000000000004406","volume":"47","author":"PJ Cundy","year":"2022","unstructured":"Cundy, P. J., Antoniou, G., Freeman, B. J. C. & Cundy, W. J. Persistently raised serum titanium levels after spinal instrumentation in children. Spine (Phila Pa 1976) 47, 1241\u20131247. https:\/\/doi.org\/10.1097\/brs.0000000000004406 (2022).","journal-title":"Spine (Phila Pa 1976)"},{"key":"99065_CR19","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620x.98b1.36374","author":"AC Cheung","year":"2016","unstructured":"Cheung, A. C. et al. Systemic cobalt toxicity from total hip arthroplasties: review of a rare condition Part 1 - history, mechanism, measurements, and pathophysiology. Bone Joint J. https:\/\/doi.org\/10.1302\/0301-620x.98b1.36374 (2016).","journal-title":"Bone Joint J."},{"key":"99065_CR20","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.tox.2017.05.015","volume":"387","author":"L Leyssens","year":"2017","unstructured":"Leyssens, L., Vinck, B., Van Der Straeten, C., Wuyts, F. & Maes, L. Cobalt toxicity in humans\u2014A review of the potential sources and systemic health effects. Toxicology 387, 43\u201356 (2017).","journal-title":"Toxicology"},{"key":"99065_CR21","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1097\/pts.0000000000000220","volume":"15","author":"BD Gessner","year":"2019","unstructured":"Gessner, B. D., Steck, T., Woelber, E. & Tower, S. S. A systematic review of systemic cobaltism after wear or corrosion of chrome-cobalt hip implants. J. Patient Saf. 15, 97\u2013104. https:\/\/doi.org\/10.1097\/pts.0000000000000220 (2019).","journal-title":"J. Patient Saf."},{"key":"99065_CR22","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1302\/0301-620x.91b6.21844","volume":"91","author":"AJ Hart","year":"2009","unstructured":"Hart, A. J. et al. Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia. J. Bone Joint Surg. Br. 91, 835\u2013842. https:\/\/doi.org\/10.1302\/0301-620x.91b6.21844 (2009).","journal-title":"J. Bone Joint Surg. Br."},{"key":"99065_CR23","volume-title":"Mayo Medical Laboratories, Interpretive Handbook: Interpretive Data for Diagnostic Laboratory Tests","author":"RM Mayo Clinic","year":"2022","unstructured":"Mayo Clinic, R. M. Mayo Medical Laboratories, Interpretive Handbook: Interpretive Data for Diagnostic Laboratory Tests (The Laboratories, 2022)."},{"key":"99065_CR24","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.joscr.2023.05.002","volume":"2","author":"S Tamagawa","year":"2023","unstructured":"Tamagawa, S. et al. Blood cobalt levels elevated with rod fracture following posterior spinal fusion in scoliosis: A report of two cases. JOS Case Rep. 2, 69\u201373. https:\/\/doi.org\/10.1016\/j.joscr.2023.05.002 (2023).","journal-title":"JOS Case Rep."},{"key":"99065_CR25","doi-asserted-by":"publisher","first-page":"2393","DOI":"10.1007\/s00586-014-3279-x","volume":"23","author":"TP Cundy","year":"2014","unstructured":"Cundy, T. P. et al. Serum titanium, niobium and aluminium levels two years following instrumented spinal fusion in children: does implant surface area predict serum metal ion levels?. Eur. Spine J. 23, 2393\u20132400. https:\/\/doi.org\/10.1007\/s00586-014-3279-x (2014).","journal-title":"Eur. Spine J."},{"key":"99065_CR26","doi-asserted-by":"publisher","DOI":"10.1097\/brs.0000000000003661","author":"PJ Cundy","year":"2020","unstructured":"Cundy, P. J., Antoniou, G., Mascarhenas, A., Freeman, B. J. C. & Cundy, W. J. Chromium metal ion release during instrumented spinal surgery in children: The effects of electrosurgery. Spine (Phila Pa 1976) https:\/\/doi.org\/10.1097\/brs.0000000000003661 (2020).","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-99065-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-99065-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-99065-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,17]],"date-time":"2025-05-17T21:02:21Z","timestamp":1747515741000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-99065-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,13]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["99065"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-99065-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,13]]},"assertion":[{"value":"3 August 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"16549"}}