{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T12:19:18Z","timestamp":1792412358259,"version":"4.4.0"},"reference-count":61,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,9]],"date-time":"2025-05-09T00:00:00Z","timestamp":1746748800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,9]],"date-time":"2025-05-09T00:00:00Z","timestamp":1746748800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002352","name":"Ain Shams University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100002352","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Full arch fixed provisional restorations are prone to fracture during function for several reasons. Those types of fractures during the healing period eliminate the cross-arch stabilization and disrupt stress distribution patterns. FEA (Finite Element Analysis) study was carried out using edentulous maxillary models where implants and other components were represented in three dimensional (3D) geometric models. Two 3D FEA models with six implants were used. Model TB: the implants were splinted with welded titanium bar; Model PB: the implants were splinted with PEEK (Poly Ether Ether Ketone) bar. An interim full arch PMMA (Poly methyl methacrylate) prosthesis was virtually designed for both models. Both models were subjected to vertical and oblique forces with a single force magnitude of 100\u00a0N. The amount of maximum equivalent Von-Mises stresses was calculated at the cervical part of the bone cylinder (marginal bone) and both frameworks. Under bilateral vertical loading, stresses were found to be comparable at the marginal bone between titanium and PEEK splinting. The PEEK framework had better and lower stress distribution than the titanium. While under unilateral oblique forces PEEK had better mechanical response on the marginal bone. And PEEK framework itself showed higher stresses than the titanium. The behavior of PEEK and Titanium splints are comparable under the vertical bilateral load. On the contrary to the oblique load, where the stresses are higher within the PEEK splint that correspondingly transmit less stresses to the underlying structures. So, PEEK was found successful in regards to the pattern of stress distribution to both implants and marginal bone, but further studies are needed to confirm its effectiveness and broader applicability.<\/jats:p>","DOI":"10.1038\/s41598-025-99750-x","type":"journal-article","created":{"date-parts":[[2025,5,9]],"date-time":"2025-05-09T04:38:40Z","timestamp":1746765520000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Finite element analysis of welded titanium bar and poly ether ether ketone bar in maxillary full arch splinted interim prosthesis"],"prefix":"10.1038","volume":"15","author":[{"given":"Lamiaa","family":"Farouk Zaki Mohamed","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hebatallah","family":"Tarek Mohamed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hany","family":"Ibrahim Eid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Soha","family":"Saeid Mohammed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rana","family":"Mohammad Abdelrahman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,9]]},"reference":[{"issue":"1","key":"99750_CR1","first-page":"141","volume":"34","author":"K Weerapong","year":"2019","unstructured":"Weerapong, K., Sirimongkolwattana, S., Sastraruji, T. & Khongkhunthian, P. Comparative study of immediate loading on short dental implants and conventional dental implants in the posterior mandible: A randomized clinical trial. Int. J. Oral Maxfac. Impl. 34(1), 141\u2013149 (2019).","journal-title":"Int. J. Oral Maxfac. Impl."},{"issue":"6","key":"99750_CR2","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1016\/j.jcms.2016.05.002","volume":"45","author":"S Zhang","year":"2017","unstructured":"Zhang, S., Wang, S. & Song, Y. Immediate loading for implant restoration compared with early or conventional loading: A meta-analysis. J. Craniomaxillofac. Surg. 45(6), 793\u2013803 (2017).","journal-title":"J. Craniomaxillofac. Surg."},{"issue":"2","key":"99750_CR3","first-page":"96","volume":"16","author":"PA Schnitman","year":"1990","unstructured":"Schnitman, P. A., Wohrle, P. S. & Rubenstein, J. E. Immediate fixed interim prostheses supported by two-stage threaded implants: methodology and results. J. Oral Implantol. 16(2), 96\u2013105 (1990).","journal-title":"J. Oral Implantol."},{"key":"99750_CR4","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1016\/S0022-3913(09)60202-X","volume":"102","author":"WS Lin","year":"2009","unstructured":"Lin, W. S. & Ercoli, C. A technique for indirect fabrication of an implant-supported, screw-retained, fixed provisional restoration in the esthetic zone. J. Prosthet. Dent 102, 393\u2013396 (2009).","journal-title":"J. Prosthet. Dent"},{"key":"99750_CR5","first-page":"261","volume":"36","author":"GJ Conte","year":"2008","unstructured":"Conte, G. J., Fagan, M. C. & Kao, R. T. Provisional restorations: A key determinant for implant site development. J. Calif. Dent. Assoc 36, 261\u2013267 (2008).","journal-title":"J. Calif. Dent. Assoc"},{"issue":"3","key":"99750_CR6","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1111\/clr.13294","volume":"29","author":"WS Lin","year":"2018","unstructured":"Lin, W. S. & Eckert, S. E. Clinical performance of intentionally tilted implants versus axially positioned implants: A systematic Review. Clin Oral Implants Res. 29(3), 78\u2013105 (2018).","journal-title":"Clin Oral Implants Res."},{"issue":"3","key":"99750_CR7","doi-asserted-by":"publisher","first-page":"e3251","DOI":"10.4322\/bds.2022.e3251","volume":"25","author":"NA Hassan","year":"2022","unstructured":"Hassan, N. A., Elkhadem, A. H., Kaddah, A. & El Khourazaty, N. S. Prosthesis and implant survival in immediately loaded full arch restorations using fiber-reinforced versus non-reinforced temporary frameworks: A randomized clinical trial. Braz. Dent. Sci. 25(3), e3251 (2022).","journal-title":"Braz. Dent. Sci."},{"issue":"2","key":"99750_CR8","doi-asserted-by":"publisher","first-page":"147","DOI":"10.4103\/0976-237X.114844","volume":"4","author":"S Singh","year":"2013","unstructured":"Singh, S., Palaskar, J. N. & Mittal, S. Comparative evaluation of surface porosities in conventional heat polymerized acrylic resin cured by water bath and microwave energy with microwavable acrylic resin cured by microwave energy. Contemp. Clin. Dent. 4(2), 147\u2013151 (2013).","journal-title":"Contemp. Clin. Dent."},{"issue":"3","key":"99750_CR9","doi-asserted-by":"publisher","first-page":"391","DOI":"10.4103\/0970-9290.70810","volume":"21","author":"R Banerjee","year":"2010","unstructured":"Banerjee, R., Banerjee, S., Prabhudesai, P. S. & Bhide, S. V. Influence of the processing technique on the flexural fatigue strength of denture base resins: An: In vitro: Investigation. Indian J. Dent. Res. 21(3), 391\u2013395 (2010).","journal-title":"Indian J. Dent. Res."},{"key":"99750_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40729-021-00330-1","volume":"7","author":"M Korsch","year":"2021","unstructured":"Korsch, M., Walther, W., Hannig, M. & Bartols, A. Evaluation of the surgical and prosthetic success of All-on-4 restorations: A retrospective cohort study of provisional vs. definitive immediate restorations. Int. J. Implant. Dent. 7, 1\u20131 (2021).","journal-title":"Int. J. Implant. Dent."},{"issue":"2","key":"99750_CR11","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1111\/j.1532-849X.1995.tb00323.x","volume":"4","author":"NL Clelland","year":"1995","unstructured":"Clelland, N. L., Lee, J. K., Bimbenet, O. C. & Brantley, W. A. A three-dimensional finite element stress analysis of angled abutments for an implant placed in the anterior maxilla. J. Prosthodont. 4(2), 95\u2013100 (1995).","journal-title":"J. Prosthodont."},{"issue":"4","key":"99750_CR12","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1111\/j.1708-8208.2006.00024.x","volume":"8","author":"P Mal\u00f3","year":"2006","unstructured":"Mal\u00f3, P., de Ara\u00fajo, N. M., Petersson, U. & Wigren, S. A pilot study of complete edentulous rehabilitation with immediate function using a new implant design: case series. Clin. Implant Dent. Relat. Res. 8(4), 223\u2013232 (2006).","journal-title":"Clin. Implant Dent. Relat. Res."},{"issue":"6","key":"99750_CR13","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1097\/ID.0b013e31826b1c68","volume":"21","author":"HJ Lee","year":"2012","unstructured":"Lee, H. J. et al. Implant stability measurements of two immediate loading protocols for the edentulous mandible: Rigid and semi-rigid splinting of the implants. Implant. Dent. 21(6), 486\u2013490 (2012).","journal-title":"Implant. Dent."},{"issue":"1","key":"99750_CR14","doi-asserted-by":"publisher","first-page":"885","DOI":"10.21608\/edj.2021.106662.1872","volume":"68","author":"A Fayyad","year":"2022","unstructured":"Fayyad, A. Prosthetic complications in immediately loaded All-on-Four mandibular prosthesis using titanium wire reinforcement versus non reinforced temporary framework. A randomized clinical trial. Egypt. Dent. J. 68(1), 885\u2013892 (2022).","journal-title":"Egypt. Dent. J."},{"issue":"1","key":"99750_CR15","volume":"2014","author":"V Fogli","year":"2014","unstructured":"Fogli, V., Camerini, M., Lauritano, D. & Carinci, F. Success and high predictability of intraorally welded titanium bar in the immediate loading implants. Case Rep. Dent. 2014(1), 215378 (2014).","journal-title":"Case Rep. Dent."},{"key":"99750_CR16","doi-asserted-by":"publisher","DOI":"10.26463\/rjms.12_1_3","author":"M Shetty","year":"2022","unstructured":"Shetty, M., Hegde, R., Adarsh, N. & Prabhu, A. Immediate rehabilitation of edentulous maxilla with a definitive prosthesis utilizing an intraorally welded titanium framework. RGUHS J. Med. Sci. https:\/\/doi.org\/10.26463\/rjms.12_1_3 (2022).","journal-title":"RGUHS J. Med. Sci."},{"issue":"1","key":"99750_CR17","first-page":"83","volume":"3","author":"J Garg","year":"2020","unstructured":"Garg, J. & Dhawan, P. Intraoral welding: A concept of immediate rehabilitation of edentulous arches-a primer. J. Prosthet. Implant. Dent. 3(1), 83 (2020).","journal-title":"J. Prosthet. Implant. Dent."},{"key":"99750_CR18","doi-asserted-by":"crossref","unstructured":"Toth, J. M. Biocompatibility of Polyaryletheretherketone Polymers. in PEEK Biomaterials Handbook 81\u201392 (2012).","DOI":"10.1016\/B978-1-4377-4463-7.10007-7"},{"key":"99750_CR19","doi-asserted-by":"publisher","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","volume":"28","author":"SM Kurtz","year":"2007","unstructured":"Kurtz, S. M. & Devine, J. N. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 28, 4845\u20134869 (2007).","journal-title":"Biomaterials"},{"key":"99750_CR20","doi-asserted-by":"publisher","first-page":"7","DOI":"10.4012\/dmj.2013-345","volume":"34","author":"B Stawarczyk","year":"2015","unstructured":"Stawarczyk, B. et al. Three-unit reinforced polyetheretherketone composite FDPs: Influence of fabrication method on load-bearing capacity and failure types. Dent. Mater. J. 34, 7\u201312 (2015).","journal-title":"Dent. Mater. J."},{"issue":"01","key":"99750_CR21","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1055\/s-0041-1731833","volume":"16","author":"RF Villefort","year":"2022","unstructured":"Villefort, R. F. et al. Mechanical response of PEKK and PEEK as frameworks for implant-supported full-arch fixed dental prosthesis: 3D finite element analysis. Eur. J. Dent. 16(01), 115\u2013121 (2022).","journal-title":"Eur. J. Dent."},{"key":"99750_CR22","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1590\/1678-775720150297","volume":"24","author":"V Suedam","year":"2016","unstructured":"Suedam, V., Moretti Neto, R. T., Sousa, E. A. & Rubo, J. H. Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures. J. Appl. Oral Sci. 24, 114\u2013120 (2016).","journal-title":"J. Appl. Oral Sci."},{"issue":"9","key":"99750_CR23","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1111\/j.1365-2842.2011.02217.x","volume":"38","author":"MB Dos Santos","year":"2011","unstructured":"Dos Santos, M. B., Da Silva Neto, J. P., Consani, R. L. & Mesquita, M. F. Three-dimensional finite element analysis of stress distribution in peri-implant bone with relined dentures and different heights of healing caps. J. Oral Rehabil. 38(9), 691\u2013696 (2011).","journal-title":"J. Oral Rehabil."},{"issue":"9","key":"99750_CR24","doi-asserted-by":"publisher","first-page":"e333","DOI":"10.1902\/jop.2014.140107","volume":"85","author":"Y Yamanishi","year":"2014","unstructured":"Yamanishi, Y., Yamaguchi, S., Imazato, S., Nakano, T. & Yatani, H. Effects of the implant design on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis of original computer-aided design models. J. Periodontol. 85(9), e333\u2013e338 (2014).","journal-title":"J. Periodontol."},{"issue":"1","key":"99750_CR25","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/j.prosdent.2020.06.029","volume":"125","author":"CA Lemos","year":"2021","unstructured":"Lemos, C. A. et al. Effect of bone quality and bone loss level around internal and external connection implants: A finite element analysis study. J. Prosthet. Dent. 125(1), 137-e1 (2021).","journal-title":"J. Prosthet. Dent."},{"key":"99750_CR26","first-page":"1029574","volume":"1","author":"E Bramanti","year":"2017","unstructured":"Bramanti, E. et al. FEM and von mises analysis on prosthetic crowns structural elements: Evaluation of different applied materials. Sci. World J. 1, 1029574 (2017).","journal-title":"Sci. World J."},{"key":"99750_CR27","doi-asserted-by":"publisher","first-page":"85","DOI":"10.4103\/JPBS.JPBS_296_18","volume":"11","author":"MS Reddy","year":"2019","unstructured":"Reddy, M. S., Sundram, R. & Abdemagyd, H. A. Application of finite element model in implant dentistry: A systematic review. J Pharm Bioallied Sci 11, 85 (2019).","journal-title":"J Pharm Bioallied Sci"},{"issue":"4","key":"99750_CR28","doi-asserted-by":"publisher","first-page":"350","DOI":"10.1046\/j.1365-2842.2002.00872.x","volume":"29","author":"KI Ak\u00e7a","year":"2002","unstructured":"Ak\u00e7a, K. I. & Iplik\u00e7io\u011flu, H. Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism. J. Oral Rehabil 29(4), 350\u20136 (2002).","journal-title":"J. Oral Rehabil"},{"key":"99750_CR29","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1067\/mpr.2001.115251","volume":"85","author":"JP Geng","year":"2001","unstructured":"Geng, J. P., Tan, K. B. & Liu, G. R. Application of finite element analysis in implant dentistry: A review of the literature. J Prosthet Dent 85, 585\u201398 (2001).","journal-title":"J Prosthet Dent"},{"issue":"2","key":"99750_CR30","doi-asserted-by":"publisher","first-page":"180","DOI":"10.4103\/jisp.jisp_278_22","volume":"27","author":"A Pandey","year":"2023","unstructured":"Pandey, A. et al. Comparison between all-on-four and all-on-six treatment concepts on stress distribution for full-mouth rehabilitation using three-dimensional finite element analysis: A biomechanical study. J. Indian Soc. Periodontol. 27(2), 180\u20138 (2023).","journal-title":"J. Indian Soc. Periodontol."},{"issue":"5","key":"99750_CR31","doi-asserted-by":"publisher","first-page":"415","DOI":"10.4103\/JIOH.JIOH_11_21","volume":"13","author":"S Shivakumar","year":"2021","unstructured":"Shivakumar, S., Kudagi, V. S. & Talwade, P. Applications of finite element analysis in dentistry: A review. Int. J. Oral Health Sci. 13(5), 415\u201322 (2021).","journal-title":"Int. J. Oral Health Sci."},{"issue":"1","key":"99750_CR32","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1186\/s12903-022-02228-9","volume":"22","author":"AM Mohamed","year":"2022","unstructured":"Mohamed, A. M., Askar, M. G. & El Homossany, M. E. Stresses induced by one piece and two piece dental implants in All-on-4\u00ae implant supported prosthesis under simulated lateral occlusal loading: Non-linear finite element analysis study. BMC Oral Health 22(1), 196 (2022).","journal-title":"BMC Oral Health"},{"issue":"2","key":"99750_CR33","first-page":"113","volume":"30","author":"NA Hassan","year":"2022","unstructured":"Hassan, N. A., Elkhadem, A. H., Elkerdawy, M. W. & Osman, R. B. Biomechanics of different types of PEEK as implant materials for implant-retained mandibular overdentures. Eur. J. Prosthodont. Restor. Dent. 30(2), 113\u201320 (2022).","journal-title":"Eur. J. Prosthodont. Restor. Dent."},{"issue":"4","key":"99750_CR34","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1111\/cid.12020","volume":"16","author":"A Agnini","year":"2014","unstructured":"Agnini, A. et al. Clinical investigation on axial versus tilted implants for immediate fixed rehabilitation of edentulous arches: Preliminary results of a single cohort study. Clin Implant Dent Relat Res. 16(4), 527\u201339 (2014).","journal-title":"Clin Implant Dent Relat Res."},{"issue":"1","key":"99750_CR35","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.prosdent.2003.08.008","volume":"91","author":"L Himmlova","year":"2004","unstructured":"Himmlova, L., K\u00e1covsk\u00fd, A. & Konvic\u0306kov\u00e1, S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthet. Dent. 91(1), 20\u20135 (2004).","journal-title":"J Prosthet. Dent."},{"issue":"1","key":"99750_CR36","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1902\/annals.2000.5.1.22","volume":"5","author":"S Winkler","year":"2000","unstructured":"Winkler, S., Morris, H. F. & Ochi, S. Implant survival to 36 months as related to length and diameter. Ann. Periodontol. 5(1), 22\u201331 (2000).","journal-title":"Ann. Periodontol."},{"issue":"6","key":"99750_CR37","doi-asserted-by":"publisher","first-page":"590","DOI":"10.4103\/2231-0762.195518","volume":"6","author":"R Eazhil","year":"2016","unstructured":"Eazhil, R., Swaminathan, S. V., Gunaseelan, M., Kannan, G. V. & Alagesan, C. Impact of implant diameter and length on stress distribution in osseointegrated implants: A 3D FEA study. J. Int. Soc. Prev. Commun. Dent. 6(6), 590\u20136 (2016).","journal-title":"J. Int. Soc. Prev. Commun. Dent."},{"issue":"5","key":"99750_CR38","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1111\/cid.12662","volume":"20","author":"P Mal\u00f3","year":"2018","unstructured":"Mal\u00f3, P. et al. Short-term report of an ongoing prospective cohort study evaluating the outcome of full-arch implant-supported fixed hybrid polyetheretherketone-acrylic resin prostheses and the All-on-Four concept. Clin. Implant. Dent. Relat. Res. 20(5), 692\u2013702 (2018).","journal-title":"Clin. Implant. Dent. Relat. Res."},{"issue":"1","key":"99750_CR39","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.prosdent.2021.04.025","volume":"129","author":"K Angelara","year":"2023","unstructured":"Angelara, K., Bratos, M. & Sorensen, J. A. Comparison of strength of milled and conventionally processed PMMA complete-arch implant-supported immediate interim fixed dental prostheses. J. Prosthet. Dent. 129(1), 221\u20137 (2023).","journal-title":"J. Prosthet. Dent."},{"issue":"1","key":"99750_CR40","doi-asserted-by":"publisher","first-page":"15","DOI":"10.3390\/biomimetics8010015","volume":"8","author":"SR Desai","year":"2023","unstructured":"Desai, S. R. et al. Three-dimensional FEA analysis of the stress distribution on titanium and graphene frameworks supported by 3 or 6-implant models. Biomimetics 8(1), 15 (2023).","journal-title":"Biomimetics"},{"issue":"1","key":"99750_CR41","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.11607\/jomi.2303","volume":"28","author":"RB Osman","year":"2013","unstructured":"Osman, R. B., Elkhadem, A. H., Ma, S. & Swain, M. V. Finite element analysis of a novel implant distribution to support maxillary overdentures. Int. J. Oral. Maxillofac. Implants 28(1), e1\u2013e10 (2013).","journal-title":"Int. J. Oral. Maxillofac. Implants"},{"issue":"1","key":"99750_CR42","doi-asserted-by":"publisher","DOI":"10.1016\/j.jormas.2022.09.011","volume":"124","author":"N Alt\u0131parmak","year":"2023","unstructured":"Alt\u0131parmak, N., Polat, S. & Onat, S. Finite element analysis of the biomechanical effects of titanium and Cfr-peek additively manufactured subperiosteal jaw implant (AMSJI) on maxilla. J. Stomatol. Oral Maxillofac. Surg., Oral Maxillofac. Surg. 124(1), 101290 (2023).","journal-title":"J. Stomatol. Oral Maxillofac. Surg., Oral Maxillofac. Surg."},{"issue":"2","key":"99750_CR43","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1111\/j.1708-8208.2008.00142.x","volume":"12","author":"JH Rubo","year":"2010","unstructured":"Rubo, J. H. & Capello Souza, E. A. Finite-element analysis of stress on dental implant prosthesis. Clin. Implant Dent. Relat. Res. 12(2), 105\u201313 (2010).","journal-title":"Clin. Implant Dent. Relat. Res."},{"issue":"4","key":"99750_CR44","first-page":"752","volume":"26","author":"G Fazi","year":"2011","unstructured":"Fazi, G., Tellini, S., Vangi, D. & Branchi, R. Three-dimensional finite element analysis of different implant configurations for a mandibular fixed prosthesis. Int. J. Oral Maxillofac. Surg. 26(4), 752 (2011).","journal-title":"Int. J. Oral Maxillofac. Surg."},{"issue":"1","key":"99750_CR45","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.jds.2011.02.005","volume":"6","author":"G Meri\u00e7","year":"2011","unstructured":"Meri\u00e7, G., Erkmen, E., Kurt, A., Tun\u00e7, Y. & Eser, A. Influence of prosthesis type and material on the stress distribution in bone around implants: A 3-dimensional finite element analysis. J. Dent. Sci. 6(1), 25\u201332 (2011).","journal-title":"J. Dent. Sci."},{"issue":"3","key":"99750_CR46","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1097\/SCS.0b013e3181d7f2e5","volume":"21","author":"WG Assun\u00e7\u00e3o","year":"2010","unstructured":"Assun\u00e7\u00e3o, W. G. et al. Effect of superstructure materials and misfit on stress distribution in a single implant-supported prosthesis: A finite element analysis. J. Craniofac. Surg. 21(3), 689\u201395 (2010).","journal-title":"J. Craniofac. Surg."},{"issue":"14","key":"99750_CR47","doi-asserted-by":"publisher","first-page":"1606","DOI":"10.1080\/10255842.2021.1903450","volume":"24","author":"SC Dayan","year":"2021","unstructured":"Dayan, S. C. & Geckili, O. The influence of framework material on stress distribution in maxillary complete-arch fixed prostheses supported by four dental implants: a three-dimensional finite element analysis. Comput. Methods Biomech. Biomed. Engin. 24(14), 1606\u201317 (2021).","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"issue":"5","key":"99750_CR48","first-page":"406","volume":"14","author":"Y \u00c7ift\u00e7i","year":"2001","unstructured":"\u00c7ift\u00e7i, Y. & Canay, \u015e. Stress distribution on the metal framework of the implant-supported fixed prosthesis using different veneering materials. Int. J. Prosthodont. 14(5), 406 (2001).","journal-title":"Int. J. Prosthodont."},{"issue":"1","key":"99750_CR49","first-page":"19","volume":"10","author":"A Sertg\u00f6z","year":"1997","unstructured":"Sertg\u00f6z, A. Finite element analysis study of the effect of superstructure material on stress distribution in an implant-supported fixed prosthesis. Int. J. Prosthodont. 10(1), 19 (1997).","journal-title":"Int. J. Prosthodont."},{"issue":"4","key":"99750_CR50","first-page":"6","volume":"32","author":"MM Aboelnagga","year":"2023","unstructured":"Aboelnagga, M. M. Comparative stress analysis of BioHPP and PEKK CAD\/CAM frameworks in mandibular all-on-four fixed-detachable prosthesis on its supporting implants. ASDJ. 32(4), 6\u201318 (2023).","journal-title":"ASDJ."},{"issue":"3","key":"99750_CR51","first-page":"138","volume":"47","author":"A El-Rahman","year":"2022","unstructured":"El-Rahman, A., Aladdin, N., El-Sharkawy, A. M., Mohy El-Din, M. H. & Saad, M. S. Strain evaluation of peek cantilever bars around implants assisted mandibular overdentures (in vitro study). ADJALEXU 47(3), 138\u201345 (2022).","journal-title":"ADJALEXU"},{"issue":"6","key":"99750_CR52","doi-asserted-by":"publisher","first-page":"346","DOI":"10.4047\/jap.2022.14.6.346","volume":"14","author":"MB Ers\u00f6z","year":"2022","unstructured":"Ers\u00f6z, M. B. & Mumcu, E. Biomechanical investigation of maxillary implant-supported full-arch prostheses produced with different framework materials: a finite elements study. J. Adv. Prosthodont. 14(6), 346 (2022).","journal-title":"J. Adv. Prosthodont."},{"issue":"5","key":"99750_CR53","doi-asserted-by":"publisher","first-page":"446","DOI":"10.4103\/jispcd.JISPCD_183_18","volume":"8","author":"OA Jaros","year":"2018","unstructured":"Jaros, O. A. et al. Biomechanical behavior of an implant system using polyether ether ketone bar: Finite element analysis. J. Int. Soc. Prev. Commun. Dent. 8(5), 446\u201350 (2018).","journal-title":"J. Int. Soc. Prev. Commun. Dent."},{"key":"99750_CR54","unstructured":"lkhooly, A. S., Elmasry, S. M., Mohamed, M. E. & Zaky, S. Z. Effect of PEKK and Bio-HPP CAD-CAM materials on stress distribution around implants in bar-retained implant-Supported prostheses. Sapporo Med. J. 58(7) (2024)"},{"issue":"4","key":"99750_CR55","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1111\/jopr.13532","volume":"32","author":"W Yu","year":"2023","unstructured":"Yu, W., Chen, S., Ma, L., Ma, X. & Xu, X. Biomechanical analysis of different framework design, framework material and bone density in the edentulous mandible with fixed implant-supported prostheses: A three-dimensional finite element study. J. Prosthodont. 32(4), 309\u201317 (2023).","journal-title":"J. Prosthodont."},{"issue":"7","key":"99750_CR56","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1111\/j.1600-0501.2009.01712.x","volume":"20","author":"LB Jacques","year":"2009","unstructured":"Jacques, L. B., Moura, M. S., Suedam, V., Souza, E. A. & Rubo, J. H. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses. Clin. Oral Implants Res. 20(7), 737\u201341 (2009).","journal-title":"Clin. Oral Implants Res."},{"issue":"6","key":"99750_CR57","doi-asserted-by":"publisher","first-page":"581","DOI":"10.11607\/ijp.5369","volume":"30","author":"KS Lee","year":"2017","unstructured":"Lee, K. S. et al. Comparative evaluation of a four-implant-supported polyetherketoneketone framework prosthesis: A three-dimensional finite element analysis based on cone beam computed tomography and computer-aided design. Int. J. Prosthodont. 30(6), 581\u2013585 (2017).","journal-title":"Int. J. Prosthodont."},{"issue":"1","key":"99750_CR58","doi-asserted-by":"publisher","first-page":"12","DOI":"10.3390\/dj10010012","volume":"10","author":"JP Tribst","year":"2022","unstructured":"Tribst, J. P. et al. Influence of framework material and posterior implant angulation in full-arch all-on-4 implant-supported prosthesis stress concentration. Dent. J. 10(1), 12 (2022).","journal-title":"Dent. J."},{"issue":"6","key":"99750_CR59","doi-asserted-by":"publisher","first-page":"866","DOI":"10.4103\/njcp.njcp_398_20","volume":"24","author":"R Shetty","year":"2021","unstructured":"Shetty, R. et al. Effect of prosthetic framework material, cantilever length and opposing arch on peri-implant strain in an all-on-four implant prostheses. Niger. J. Clin. Pract. 24(6), 866\u201373 (2021).","journal-title":"Niger. J. Clin. Pract."},{"key":"99750_CR60","first-page":"1","volume":"5","author":"AG Franco","year":"2022","unstructured":"Franco, A. G., de Carvalho, G. A., Dias, S. C., Ramos, E. V. & Franco, A. B. Different protocol bar designs made of polyether ether ketone (PEEK) and metal: An analysis of mechanical behavior: Mechanical behavior of three PEEK infrastructures. IAJMH 5, 1\u20138 (2022).","journal-title":"IAJMH"},{"issue":"1","key":"99750_CR61","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1563\/AAID-JOI-D-11-00044","volume":"40","author":"E G\u00f6re","year":"2014","unstructured":"G\u00f6re, E. & Evlio\u011flu, G. Assessment of the effect of two occlusal concepts for implant-supported fixed prostheses by finite element analysis in patients with bruxism. J. Oral Implantol. 40(1), 68\u201375 (2014).","journal-title":"J. Oral Implantol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-99750-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-99750-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-99750-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,9]],"date-time":"2025-05-09T05:07:45Z","timestamp":1746767265000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-99750-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,9]]},"references-count":61,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["99750"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-99750-x","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-5183274\/v1","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,9]]},"assertion":[{"value":"30 September 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"16193"}}