{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T00:05:42Z","timestamp":1787616342532,"version":"build-2736575974"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T00:00:00Z","timestamp":1767916800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T00:00:00Z","timestamp":1770249600000},"content-version":"vor","delay-in-days":27,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Science and Technology Project of Yinzhou District","award":["2022AS062"],"award-info":[{"award-number":["2022AS062"]}]},{"name":"Ningbo Clinical Research Center for Orthopedics, Sports Medicine &\u00a0Rehabilitation","award":["2024L004"],"award-info":[{"award-number":["2024L004"]}]},{"name":"Ningbo Clinical Research Center for Orthopedics, Sports Medicine &\u00a0Rehabilitation","award":["2024L004"],"award-info":[{"award-number":["2024L004"]}]},{"name":"Ningbo Clinical Research Center for Orthopedics, Sports Medicine &\u00a0Rehabilitation","award":["2024L004"],"award-info":[{"award-number":["2024L004"]}]},{"name":"Ningbo Clinical Research Center for Orthopedics, Sports Medicine &\u00a0Rehabilitation","award":["2024L004"],"award-info":[{"award-number":["2024L004"]}]},{"name":"Ningbo Clinical Research Center for Orthopedics, Sports Medicine &\u00a0Rehabilitation","award":["2024L004"],"award-info":[{"award-number":["2024L004"]}]},{"DOI":"10.13039\/501100017594","name":"Medical and Health Science and Technology Project of Zhejiang Province","doi-asserted-by":"crossref","award":["2020KY892"],"award-info":[{"award-number":["2020KY892"]}],"id":[{"id":"10.13039\/501100017594","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Ningbo Public Welfare Science and Technology Program Project","award":["2024S173"],"award-info":[{"award-number":["2024S173"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-35057-9","type":"journal-article","created":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T17:44:46Z","timestamp":1767980686000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Biomechanical study on different internal fixation methods for treating Mayo type IIA olecranon fractures of the ulna"],"prefix":"10.1038","volume":"16","author":[{"given":"Jun","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuqin","family":"Fang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunqiang","family":"Zhuang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fude","family":"Jiao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Gu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,9]]},"reference":[{"key":"35057_CR1","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1016\/j.jseint.2021.11.015","volume":"6","author":"M Cantore","year":"2022","unstructured":"Cantore, M., Candela, V., Sessa, P., Giannicola, G. & Gumina, S. Epidemiology of isolated olecranon fractures: a detailed survey on a large sample of patients in a suburban area. JSES Int. 6, 309\u2013314. https:\/\/doi.org\/10.1016\/j.jseint.2021.11.015 (2022).","journal-title":"JSES Int."},{"key":"35057_CR2","doi-asserted-by":"publisher","first-page":"129","DOI":"10.32098\/mltj.02.2015.13","volume":"5","author":"A den Hamer","year":"2015","unstructured":"den Hamer, A. et al. Current techniques for management of transverse displaced olecranon fractures. Muscles Ligaments Tendons J. 5, 129\u2013140 (2015).","journal-title":"Muscles Ligaments Tendons J."},{"key":"35057_CR3","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1016\/j.jhsa.2012.12.036","volume":"38","author":"N Baecher","year":"2013","unstructured":"Baecher, N. & Edwards, S. Olecranon fractures. J. Hand Surg. Am. 38, 593\u2013604. https:\/\/doi.org\/10.1016\/j.jhsa.2012.12.036 (2013).","journal-title":"J. Hand Surg. Am."},{"key":"35057_CR4","doi-asserted-by":"publisher","DOI":"10.1016\/j.ocl.2008.01.002","author":"CJH Veillette","year":"2008","unstructured":"Veillette, C. J. H. & Steinmann, S. P. Olecranon fractures. Orthop. Clin. North. Am. https:\/\/doi.org\/10.1016\/j.ocl.2008.01.002 (2008).","journal-title":"Orthop. Clin. North. Am."},{"key":"35057_CR5","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/1749-799X-3-9","volume":"3","author":"BE Chalidis","year":"2008","unstructured":"Chalidis, B. E., Sachinis, N. C., Samoladas, E. P., Dimitriou, C. G. & Pournaras, J. D. Is tension band wiring technique the gold standard for the treatment of olecranon fractures? A long term functional outcome study. J. Orthop. Surg, Res. 3, 9. https:\/\/doi.org\/10.1186\/1749-799X-3-9 (2008).","journal-title":"J. Orthop. Surg, Res."},{"key":"35057_CR6","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s12306-018-0556-6","volume":"103","author":"AJ Powell","year":"2018","unstructured":"Powell, A. J., Farhan-Alanie, O. M. & McGraw, I. W. W. Tension band wiring versus locking plate fixation for simple, two-part Mayo 2A olecranon fractures: a comparison of post-operative outcomes, complications, reoperations and economics. Musculoskelet. Surg. 103, 155\u2013160. https:\/\/doi.org\/10.1007\/s12306-018-0556-6 (2018).","journal-title":"Musculoskelet. Surg."},{"key":"35057_CR7","doi-asserted-by":"publisher","first-page":"1252","DOI":"10.1016\/j.injury.2004.12.028","volume":"36","author":"JR Parker","year":"2005","unstructured":"Parker, J. R., Conroy, J. & Campbell, D. A. Anterior interosseus nerve injury following tension band wiring of the olecranon. Injury 36, 1252\u20131253 (2005).","journal-title":"Injury"},{"key":"35057_CR8","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1097\/01.bot.0000164338.79013.10","volume":"19","author":"JJ Candal-Couto","year":"2005","unstructured":"Candal-Couto, J. J., Williams, J. R. & Sanderson, P. L. Impaired forearm rotation after tension-band-wiring fixation of olecranon fractures: evaluation of the transcortical K-wire technique. J. Orthop. Trauma. 19, 480\u2013482 (2005).","journal-title":"J. Orthop. Trauma."},{"key":"35057_CR9","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1097\/TA.0b013e3181ad554c","volume":"68","author":"TW Huang","year":"2010","unstructured":"Huang, T. W. et al. Tension band wiring for olecranon fractures: relative stability of Kirschner wires in various configurations. J. Trauma. 68, 173\u2013176. https:\/\/doi.org\/10.1097\/TA.0b013e3181ad554c (2010).","journal-title":"J. Trauma."},{"key":"35057_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1302\/2058-5241.4.180022","volume":"4","author":"S Siebenlist","year":"2019","unstructured":"Siebenlist, S., Buchholz, A. & Braun, K. F. Fractures of the proximal ulna: current concepts in surgical management. EFORT Open. Rev. 4, 1\u20139. https:\/\/doi.org\/10.1302\/2058-5241.4.180022 (2019).","journal-title":"EFORT Open. Rev."},{"key":"35057_CR11","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1097\/01.bot.0000246467.32574.fe","volume":"21","author":"EA Hewins","year":"2007","unstructured":"Hewins, E. A. et al. Plate fixation of olecranon osteotomies. J. Orthop. Trauma. 21, 58\u201362 (2007).","journal-title":"J. Orthop. Trauma"},{"key":"35057_CR12","doi-asserted-by":"publisher","first-page":"680","DOI":"10.1016\/j.jse.2024.06.019","volume":"34","author":"AO Batihan","year":"2025","unstructured":"Batihan, A. O., Maden, M., Ozdemir, M. & Kazimoglu, C. Is headless screw a valid alternative for the fixation of chevron olecranon osteotomy? A Biomechanical comparison of 4 fixation methods. J. Shoulder Elbow Surg. 34, 680\u2013687. https:\/\/doi.org\/10.1016\/j.jse.2024.06.019 (2025).","journal-title":"J. Shoulder Elbow Surg."},{"key":"35057_CR13","doi-asserted-by":"publisher","first-page":"1522","DOI":"10.1016\/j.injury.2020.04.018","volume":"51","author":"KY Wang","year":"2020","unstructured":"Wang, K. Y. et al. Where should the pins be placed to decrease the failure rate after fixation of a Mayo IIA olecranon fracture? A Biomechanical analysis. Injury-International J. Care Injured 51, 1522\u20131526. https:\/\/doi.org\/10.1016\/j.injury.2020.04.018 (2020).","journal-title":"Injury-International J. Care Injured"},{"key":"35057_CR14","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-025-08828-0","author":"SH Lee","year":"2025","unstructured":"Lee, S. H. & Lee, Y. H. Ideal pin length and interval in tension band wiring using ring pins for transverse olecranon fractures: a biomechanical study. BMC Musculoskelet. Disord. https:\/\/doi.org\/10.1186\/s12891-025-08828-0 (2025).","journal-title":"BMC Musculoskelet. Disord."},{"key":"35057_CR15","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1302\/0301-620X.93B2.24613","volume":"93","author":"J Wilson","year":"2011","unstructured":"Wilson, J., Bajwa, A., Kamath, V. & Rangan, A. Biomechanical comparison of interfragmentary compression in transverse fractures of the olecranon. J. Bone Joint Surg. Br. 93, 245\u2013250. https:\/\/doi.org\/10.1302\/0301-620X.93B2.24613 (2011).","journal-title":"J. Bone Joint Surg. Br."},{"key":"35057_CR16","doi-asserted-by":"publisher","first-page":"1593","DOI":"10.1016\/j.otsr.2019.08.020","volume":"105","author":"R Di Francia","year":"2019","unstructured":"Di Francia, R. et al. Advantages of expulsion-proof pins in the treatment of olecranon fractures with tension band wiring: comparison with a control group. Orthop. Traumatol. Surg. Res. 105, 1593\u20131599. https:\/\/doi.org\/10.1016\/j.otsr.2019.08.020 (2019).","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"35057_CR17","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1007\/s00064-017-0490-z","volume":"29","author":"P Gierer","year":"2017","unstructured":"Gierer, P., Wichelhaus, A. & Rotter, R. [Fractures of the olecranon]. Oper. Orthop. Traumatol. 29, 107\u2013114. https:\/\/doi.org\/10.1007\/s00064-017-0490-z (2017).","journal-title":"Oper. Orthop. Traumatol."},{"key":"35057_CR18","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1016\/j.injury.2012.08.052","volume":"44","author":"PRG Brink","year":"2012","unstructured":"Brink, P. R. G. et al. Tension band wiring of the olecranon: is it really a dynamic principle of osteosynthesis? Injury 44, 518\u2013522. https:\/\/doi.org\/10.1016\/j.injury.2012.08.052 (2012).","journal-title":"Injury"},{"key":"35057_CR19","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1016\/j.jse.2005.08.002","volume":"15","author":"P Villanueva","year":"2006","unstructured":"Villanueva, P., Osorio, F., Commessatti, M. & Sanchez-Sotelo, J. Tension-band wiring for olecranon fractures: analysis of risk factors for failure. J. Shoulder Elb. Surg. 15, 351\u2013356 (2006).","journal-title":"J. Shoulder Elb. Surg."},{"key":"35057_CR20","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.jor.2014.04.018","volume":"12","author":"KW Chan","year":"2014","unstructured":"Chan, K. W. & Donnelly, K. J. Does K-wire position in tension band wiring of olecranon fractures affect its complications and removal of metal rate? J. Orthop. 12, 111\u2013117. https:\/\/doi.org\/10.1016\/j.jor.2014.04.018 (2014).","journal-title":"J. Orthop."},{"key":"35057_CR21","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2024.1500317","author":"X Yu","year":"2024","unstructured":"Yu, X. et al. Perforated Kirschner wire tension band in the treatment of Mayo IIA olecranon fractures. Front. Surg. https:\/\/doi.org\/10.3389\/fsurg.2024.1500317 (2024).","journal-title":"Front. Surg."},{"key":"35057_CR22","doi-asserted-by":"publisher","first-page":"2024","DOI":"10.1007\/s43465-023-01017-y","volume":"57","author":"Y Kuwahara","year":"2023","unstructured":"Kuwahara, Y. et al. Locked tension band wiring: A modified technique for olecranon Fractures-A multicenter study comparing clinical outcomes and complications with conventional methods. INDIAN J. Orthop. 57, 2024\u20132030. https:\/\/doi.org\/10.1007\/s43465-023-01017-y (2023).","journal-title":"INDIAN J. Orthop."},{"key":"35057_CR23","doi-asserted-by":"publisher","first-page":"1907","DOI":"10.2106\/JBJS.24.01461","volume":"107","author":"KS Midtgaard","year":"2025","unstructured":"Midtgaard, K. S. et al. Tension band wiring versus precontoured plate fixation for 2-Part and multifragmented olecranon fractures: A prospective randomized trial. J. Bone Joint Surg. Am. 107, 1907\u20131917. https:\/\/doi.org\/10.2106\/JBJS.24.01461 (2025).","journal-title":"J. Bone Joint Surg. Am."},{"key":"35057_CR24","doi-asserted-by":"publisher","first-page":"9999","DOI":"10.1038\/s41598-024-60264-7","volume":"14","author":"Y Zhao","year":"2024","unstructured":"Zhao, Y. et al. The effect of ding\u2019s screws and tension band wiring for treatment of olecranon fractures: a Biomechanical study. Sci. Rep. 14, 9999. https:\/\/doi.org\/10.1038\/s41598-024-60264-7 (2024).","journal-title":"Sci. Rep."},{"key":"35057_CR25","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1016\/j.jhsa.2021.12.009","volume":"47","author":"JN Steadman","year":"2022","unstructured":"Steadman, J. N., Stephens, A. R., Zhang, C., Presson, A. P. & Kazmers, N. H. Cost assessment of plating versus tension band wiring constructs for treating Mayo type 2A olecranon fractures. J. Hand Surg. Am. 47, 311\u2013319. https:\/\/doi.org\/10.1016\/j.jhsa.2021.12.009 (2022).","journal-title":"J. Hand Surg. Am."},{"key":"35057_CR26","doi-asserted-by":"publisher","first-page":"2347","DOI":"10.1016\/j.jse.2020.05.035","volume":"29","author":"BYJ Tan","year":"2020","unstructured":"Tan, B. Y. J., Pereira, M. J., Ng, J. W. & Kwek, E. B. K. The ideal implant for Mayo 2A olecranon fractures? An economic evaluation. J. Shoulder Elb. Surg. 29, 2347\u20132352. https:\/\/doi.org\/10.1016\/j.jse.2020.05.035 (2020).","journal-title":"J. Shoulder Elb. Surg."},{"key":"35057_CR27","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1007\/s00590-015-1724-0","volume":"26","author":"EM DelSole","year":"2015","unstructured":"DelSole, E. M., Pean, C. A., Tejwani, N. C. & Egol, K. A. Outcome after olecranon fracture repair: does construct type matter? Eur. J. Orthop. Surg. Traumatol. 26, 153\u2013159. https:\/\/doi.org\/10.1007\/s00590-015-1724-0 (2015).","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"key":"35057_CR28","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1016\/j.jse.2011.07.022","volume":"21","author":"SC van der Linden","year":"2011","unstructured":"van der Linden, S. C., van Kampen, A. & Jaarsma, R. L. K-wire position in tension-band wiring technique affects stability of wires and long-term outcome in surgical treatment of olecranon fractures. J. Shoulder Elb. Surg. 21, 405\u2013411. https:\/\/doi.org\/10.1016\/j.jse.2011.07.022 (2011).","journal-title":"J. Shoulder Elb. Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-35057-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-35057-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-35057-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T09:21:47Z","timestamp":1770283307000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-35057-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,9]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["35057"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-35057-9","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-7153724\/v1","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,9]]},"assertion":[{"value":"18 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"4947"}}