{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T03:51:35Z","timestamp":1770695495928,"version":"3.49.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T00:00:00Z","timestamp":1768694400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T00:00:00Z","timestamp":1770595200000},"content-version":"vor","delay-in-days":22,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-35172-7","type":"journal-article","created":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T16:35:22Z","timestamp":1768754122000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Intramedullary nail design for Thais with novel multi-femur shape optimization approach"],"prefix":"10.1038","volume":"16","author":[{"given":"Duangkamon","family":"Sayabut","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chanyaphan","family":"Virulsri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pairat","family":"Tangpornprasert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,1,18]]},"reference":[{"key":"35172_CR1","doi-asserted-by":"publisher","first-page":"12734","DOI":"10.1038\/s41598-023-40087-8","volume":"13","author":"N Walter","year":"2023","unstructured":"Walter, N. et al. Epidemiology and treatment of proximal femoral fractures in the elderly US population. Sci. Rep. 13, 12734. https:\/\/doi.org\/10.1038\/s41598-023-40087-8 (2023).","journal-title":"Sci. Rep."},{"key":"35172_CR2","first-page":"11860","volume":"13","author":"A Tuxun","year":"2021","unstructured":"Tuxun, A. et al. Effects of intramedullary nailing fixation on quality of life and joint function in patients with femoral neck fractures. Am. J. Transl. Res. 13, 11860 (2021).","journal-title":"Am. J. Transl. Res."},{"key":"35172_CR3","first-page":"324","volume":"4","author":"C Burnei","year":"2011","unstructured":"Burnei, C., Popescu, G., Barbu, D. & Capraru, F. Intramedullary osteosynthesis versus plate osteosynthesis in subtrochanteric fractures. J. Med. Life 4, 324 (2011).","journal-title":"J. Med. Life"},{"key":"35172_CR4","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1302\/0301-620X.87B1.15295","volume":"87","author":"R Miedel","year":"2005","unstructured":"Miedel, R., Ponzer, S., T\u00f6rnkvist, H., S\u00f6derqvist, A. & Tidermark, J. The standard Gamma nail or the Medoff sliding plate for unstable trochanteric and subtrochanteric fractures: A randomised, controlled trial. J. Bone Joint Surg. Br. 87, 68\u201375 (2005).","journal-title":"J. Bone Joint Surg. Br."},{"key":"35172_CR5","doi-asserted-by":"publisher","first-page":"639","DOI":"10.5152\/j.aott.2020.19216","volume":"54","author":"J Wang","year":"2020","unstructured":"Wang, J., Li, H., Jia, H. & Ma, X. Intramedullary versus extramedullary fixation in the treatment of subtrochanteric femur fractures: A comprehensive systematic review and meta-analysis. Acta Orthop. Traumatol. Turc. 54, 639. https:\/\/doi.org\/10.5152\/j.aott.2020.19216 (2020).","journal-title":"Acta Orthop. Traumatol. Turc."},{"key":"35172_CR6","unstructured":"Synthes, D. PFNA. Proximal Femoral Nail Antirotation Surgical Technique. (2015)."},{"key":"35172_CR7","unstructured":"Stryker. Gamma3 Long Nail R1.5 and R2.0 Operative technique. (2014)."},{"key":"35172_CR8","unstructured":"Nephew, S. TRIGEN INTERTAN Intertrochanteric Antegrade Nail."},{"key":"35172_CR9","first-page":"1377","volume":"91","author":"N Chantarapanich","year":"2011","unstructured":"Chantarapanich, N., Sitthiseripratip, K., Mahaisavariya, B., Wongcumchang, M. & Siribodhi, P. 3D geometrical assessment of femoral curvature: a reverse engineering technique. J. Med. Assoc. Thai. 91, 1377 (2011).","journal-title":"J. Med. Assoc. Thai."},{"key":"35172_CR10","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/730538","author":"H-J Cho","year":"2015","unstructured":"Cho, H.-J., Kwak, D.-S. & Kim, I.-B. Morphometric evaluation of Korean femurs by geometric computation: comparisons of the sex and the population. BioMed Res. Int. https:\/\/doi.org\/10.1155\/2015\/730538 (2015).","journal-title":"BioMed Res. Int."},{"key":"35172_CR11","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/318391","author":"X-Y Su","year":"2015","unstructured":"Su, X.-Y. et al. Three-dimensional analysis of the curvature of the femoral canal in 426 Chinese femurs. BioMed Res. Int. https:\/\/doi.org\/10.1155\/2015\/318391 (2015).","journal-title":"BioMed Res. Int."},{"key":"35172_CR12","unstructured":"BIOMET, Z. Zimmer Natural Nail System, Cephalomedullary Asia Nail, Surgical Technique. 3 edn, (2016)."},{"key":"35172_CR13","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1016\/j.jcot.2017.12.006","volume":"10","author":"A Shetty","year":"2019","unstructured":"Shetty, A., Shenoy, P. & Swaminathan, R. Mismatch of long Gamma intramedullary nail with bow of the femur: Does radius of curvature of the nail increase risk of distal femoral complications?. J. Clin. Orthop. Trauma 10, 302\u2013304. https:\/\/doi.org\/10.1016\/j.jcot.2017.12.006 (2019).","journal-title":"J. Clin. Orthop. Trauma"},{"key":"35172_CR14","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.jor.2014.04.010","volume":"11","author":"AJ Kanawati","year":"2014","unstructured":"Kanawati, A. J., Jang, B., McGee, R. & Sungaran, J. The influence of entry point and radius of curvature on femoral intramedullary nail position in the distal femur. J. Orthop. 11, 68\u201371. https:\/\/doi.org\/10.1016\/j.jor.2014.04.010 (2014).","journal-title":"J. Orthop."},{"key":"35172_CR15","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1097\/01.bot.0000154481.46693.69","volume":"19","author":"RF Ostrum","year":"2005","unstructured":"Ostrum, R. F. & Levy, M. S. Penetration of the distal femoral anterior cortex during intramedullary nailing for subtrochanteric fractures: A report of three cases. J. Orthop. Trauma 19, 656\u2013660. https:\/\/doi.org\/10.1097\/01.bot.0000154481.46693.69 (2005).","journal-title":"J. Orthop. Trauma"},{"key":"35172_CR16","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1097\/00005131-200408000-00003","volume":"18","author":"KA Egol","year":"2004","unstructured":"Egol, K. A., Chang, E. Y., Cvitkovic, J., Kummer, F. J. & Koval, K. J. Mismatch of current intramedullary nails with the anterior bow of the femur. J. Orthop. Trauma 18, 410\u2013415. https:\/\/doi.org\/10.1097\/00005131-200408000-00003 (2004).","journal-title":"J. Orthop. Trauma"},{"key":"35172_CR17","doi-asserted-by":"publisher","unstructured":"Akman, A., Demirkan, A. F. & Akkoyunlu, N. S. Three-dimensional geometrical modelling of the femoral intramedullary cavity using ring cyclide model. Joint diseases and related surgery 31, 14 (2020). https:\/\/doi.org\/10.5606\/ehc.2020.65258","DOI":"10.5606\/ehc.2020.65258"},{"key":"35172_CR18","doi-asserted-by":"publisher","DOI":"10.1097\/md.0000000000015073","author":"D Ren","year":"2019","unstructured":"Ren, D. et al. An innovative method for measuring the femoral arch. Medicine https:\/\/doi.org\/10.1097\/md.0000000000015073 (2019).","journal-title":"Medicine"},{"key":"35172_CR19","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.injury.2020.09.028","volume":"52","author":"JC Arnone","year":"2021","unstructured":"Arnone, J. C. et al. Variability of human femoral geometry and its implications on nail design. Injury 52, 109\u2013116. https:\/\/doi.org\/10.1016\/j.injury.2020.09.028 (2021).","journal-title":"Injury"},{"key":"35172_CR20","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1007\/s00276-005-0019-2","volume":"27","author":"A Harma","year":"2005","unstructured":"Harma, A., Germen, B., Karakas, H. M., Elmali, N. & Inan, M. The comparison of femoral curves and curves of contemporary intramedullary nails. Surg. Radiol. Anat. 27, 502\u2013506. https:\/\/doi.org\/10.1007\/s00276-005-0019-2 (2005).","journal-title":"Surg. Radiol. Anat."},{"key":"35172_CR21","doi-asserted-by":"publisher","unstructured":"Abdelaal, A. H. K. et al. Radiological assessment of the femoral bowing in Japanese population. https:\/\/doi.org\/10.1051\/sicotj\/2015037 (2016).","DOI":"10.1051\/sicotj\/2015037"},{"key":"35172_CR22","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.orthres.2004.06.013","volume":"23","author":"W Tang","year":"2005","unstructured":"Tang, W., Chiu, K., Kwan, M., Ng, T. & Yau, W. Sagittal bowing of the distal femur in Chinese patients who require total knee arthroplasty. J. Orthop. Res. 23, 41\u201345. https:\/\/doi.org\/10.1016\/j.orthres.2004.06.013 (2005).","journal-title":"J. Orthop. Res."},{"key":"35172_CR23","doi-asserted-by":"publisher","first-page":"034502","DOI":"10.1115\/1.4029061","volume":"137","author":"S Chanda","year":"2015","unstructured":"Chanda, S., Gupta, S. & Kumar Pratihar, D. A genetic algorithm based multi-objective shape optimization scheme for cementless femoral implant. J. Biomech. Eng. 137, 034502. https:\/\/doi.org\/10.1115\/1.4029061 (2015).","journal-title":"J. Biomech. Eng."},{"key":"35172_CR24","doi-asserted-by":"publisher","first-page":"2326","DOI":"10.3390\/ma12142326","volume":"12","author":"N Korunovic","year":"2019","unstructured":"Korunovic, N. et al. In silico optimization of femoral fixator position and configuration by parametric CAD model. Materials 12, 2326. https:\/\/doi.org\/10.3390\/ma12142326 (2019).","journal-title":"Materials"},{"key":"35172_CR25","unstructured":"Carbofix. Trochanteric (PF) Nailing System, Surgical Technique. 9.1.2019 edn, (2019)."},{"key":"35172_CR26","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1016\/j.jos.2017.02.003","volume":"22","author":"N Chantarapanich","year":"2017","unstructured":"Chantarapanich, N. et al. 3D CAD\/reverse engineering technique for assessment of Thai morphology: Proximal femur and acetabulum. J. Orthop. Sci. 22, 703\u2013709. https:\/\/doi.org\/10.1016\/j.jos.2017.02.003 (2017).","journal-title":"J. Orthop. Sci."},{"key":"35172_CR27","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1016\/j.patrec.2009.09.011","volume":"31","author":"AK Jain","year":"2010","unstructured":"Jain, A. K. Data clustering: 50 years beyond K-means. Pattern Recognit. Lett. 31, 651\u2013666. https:\/\/doi.org\/10.1016\/j.patrec.2009.09.011 (2010).","journal-title":"Pattern Recognit. Lett."},{"key":"35172_CR28","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1016\/j.neucom.2017.06.053","volume":"267","author":"A Saxena","year":"2017","unstructured":"Saxena, A. et al. A review of clustering techniques and developments. Neurocomputing 267, 664\u2013681. https:\/\/doi.org\/10.1016\/j.neucom.2017.06.053 (2017).","journal-title":"Neurocomputing"},{"key":"35172_CR29","unstructured":"Chougule, V., Mulay, A. & Ahuja, B. Clinical case study: spine modeling for minimum invasive spine surgeries (MISS) using rapid prototyping. Bone (CT) 226, 3071 (2018)."},{"key":"35172_CR30","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4939-3305-1","volume-title":"Handbook of biomaterial properties","author":"W Murphy","year":"2016","unstructured":"Murphy, W., Black, J. & Hastings, G. W. Handbook of biomaterial properties Vol. 676 (Springer, 2016)."},{"key":"35172_CR31","doi-asserted-by":"publisher","first-page":"1883","DOI":"10.1016\/j.injury.2019.08.014","volume":"50","author":"C-Y Jang","year":"2019","unstructured":"Jang, C.-Y. et al. Effect of fracture levels on the strength of bone-implant constructs in subtrochanteric fracture models fixed using short cephalomedullary nails: A finite element analysis. Injury 50, 1883\u20131888. https:\/\/doi.org\/10.1016\/j.injury.2019.08.014 (2019).","journal-title":"Injury"},{"key":"35172_CR32","volume-title":"In Breakthroughs in Statistics: Foundations and Basic Theory 342\u2013357","author":"A Wald","year":"1950","unstructured":"Wald, A. In Breakthroughs in Statistics: Foundations and Basic Theory 342\u2013357 (Springer, 1950)."},{"key":"35172_CR33","doi-asserted-by":"publisher","first-page":"1110","DOI":"10.3390\/bioengineering11111110","volume":"11","author":"W Xie","year":"2024","unstructured":"Xie, W. et al. Comparison of three internal fixation constructs for AO\/OTA 33\u2013A3 distal femoral fractures: A biomechanical study. Bioengineering 11, 1110. https:\/\/doi.org\/10.3390\/bioengineering11111110 (2024).","journal-title":"Bioengineering"},{"key":"35172_CR34","doi-asserted-by":"publisher","first-page":"803","DOI":"10.1016\/j.clinbiomech.2014.05.010","volume":"29","author":"S Samiezadeh","year":"2014","unstructured":"Samiezadeh, S., Avval, P. T., Fawaz, Z. & Bougherara, H. Biomechanical assessment of composite versus metallic intramedullary nailing system in femoral shaft fractures: a finite element study. Clin. Biomech. 29, 803\u2013810. https:\/\/doi.org\/10.1016\/j.clinbiomech.2014.05.010 (2014).","journal-title":"Clin. Biomech."},{"key":"35172_CR35","volume-title":"In Essential Biomechanics for Orthopedic Trauma: A Case-Based Guide 221\u2013235","author":"JC Woods","year":"2020","unstructured":"Woods, J. C. & Della Rocca, G. J. In Essential Biomechanics for Orthopedic Trauma: A Case-Based Guide 221\u2013235 (Springer, 2020)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-35172-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-35172-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-35172-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T10:53:33Z","timestamp":1770634413000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-35172-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,18]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["35172"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-35172-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,18]]},"assertion":[{"value":"26 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"5488"}}