{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T23:12:44Z","timestamp":1770333164898,"version":"3.49.0"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T00:00:00Z","timestamp":1768176000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T00:00:00Z","timestamp":1770249600000},"content-version":"vor","delay-in-days":24,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-35975-8","type":"journal-article","created":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T20:45:25Z","timestamp":1768250725000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of apparent and three-dimensional pupillary diameter measurements in cataract patients and their impact on multifocal intraocular lens selection"],"prefix":"10.1038","volume":"16","author":[{"given":"Bin","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huafeng","family":"Ma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lin","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zaihong","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,1,12]]},"reference":[{"issue":"1","key":"35975_CR1","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1097\/ICU.0000000000001092","volume":"36","author":"H Hashemi","year":"2025","unstructured":"Hashemi, H., Fayaz, F., Hashemi, A. & Khabazkhoob, M. Global prevalence of cataract surgery. Curr. Opin. Ophthalmol. 36 (1), 10\u201317. https:\/\/doi.org\/10.1097\/ICU.0000000000001092 (2025).","journal-title":"Curr. Opin. Ophthalmol."},{"issue":"11","key":"35975_CR2","doi-asserted-by":"publisher","first-page":"1331","DOI":"10.1097\/j.jcrs.0000000000000947","volume":"48","author":"P Wu","year":"2022","unstructured":"Wu, P. et al. Influence of ocular biometric parameters such as effective lens position, keratometry, and axial length on near add power of multifocal intraocular lens. J. Cataract Refract. Surg. 48 (11), 1331\u20131334. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000947 (2022).","journal-title":"J. Cataract Refract. Surg."},{"issue":"11","key":"35975_CR3","doi-asserted-by":"publisher","first-page":"E164","DOI":"10.1016\/j.ophtha.2020.09.026","volume":"128","author":"R Rampat","year":"2021","unstructured":"Rampat, R. & Gatinel, D. Multifocal and extended depth-of-focus intraocular lenses in 2020. Ophthalmology 128 (11), E164\u2013E185. https:\/\/doi.org\/10.1016\/j.ophtha.2020.09.026 (2021).","journal-title":"Ophthalmology"},{"key":"35975_CR4","doi-asserted-by":"publisher","first-page":"11686","DOI":"10.1038\/s41598-018-30141-1","volume":"8","author":"M Ouchi","year":"2018","unstructured":"Ouchi, M. & Shiba, T. Diffractive multifocal intraocular lens implantation in eyes with a small-diameter pupil. Sci. Rep. 8, 11686. https:\/\/doi.org\/10.1038\/s41598-018-30141-1 (2018).","journal-title":"Sci. Rep."},{"issue":"SUPPL 5","key":"35975_CR5","doi-asserted-by":"publisher","first-page":"S831","DOI":"10.4103\/IJO.IJO_544_24","volume":"72","author":"U Camellin","year":"2024","unstructured":"Camellin, U. et al. Estimation of pupil size at Iris plane and its magnification after cataract surgery. Indian J. Ophthalmol. 72 (SUPPL 5), S831\u2013S837. https:\/\/doi.org\/10.4103\/IJO.IJO_544_24 (2024).","journal-title":"Indian J. Ophthalmol."},{"issue":"4","key":"35975_CR6","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1038\/eye.2009.170","volume":"24","author":"K Kamiya","year":"2010","unstructured":"Kamiya, K., Shimizu, K., Igarashi, A. & Ishikawa, H. Evaluation of pupil diameter after posterior chamber Phakic intraocular lens implantation. Eye 24 (4), 588\u2013594. https:\/\/doi.org\/10.1038\/eye.2009.170 (2010).","journal-title":"Eye"},{"issue":"3","key":"35975_CR7","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1055\/s-2008-1034693","volume":"215","author":"A Langenbucher","year":"1999","unstructured":"Langenbucher, A., Neumann, J., Kus, M. M. & Seitz, B. Calculation of pupil localization and dimension in keratoconus using exact Raytracing of corneal topography height data. Klin. Monatsbl. Augenheilkd. 215 (3), 163\u2013168. https:\/\/doi.org\/10.1055\/s-2008-1034693 (1999).","journal-title":"Klin. Monatsbl. Augenheilkd."},{"issue":"10","key":"35975_CR8","doi-asserted-by":"publisher","first-page":"1924","DOI":"10.1016\/S0886-3350(03)00214-1","volume":"29","author":"KA Freedman","year":"2003","unstructured":"Freedman, K. A., Brown, S. M., Mathews, S. M. & Young, R. S. L. Pupil size and the ablation zone in laser refractive surgery: considerations based on geometric optics. J. Cataract Refract. Surg. 29 (10), 1924\u20131931. https:\/\/doi.org\/10.1016\/S0886-3350(03)00214-1 (2003).","journal-title":"J. Cataract Refract. Surg."},{"key":"35975_CR9","unstructured":"OCULUS & Pentacam AXL Instruction Manual. Article no. G\/70020\/EN, Rev. 08. Wetzlar: OCULUS Optikger\u00e4te GmbH. https:\/\/documents.oculus.de\/G-70100-EN-04.pdf (2022)."},{"issue":"6","key":"35975_CR10","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1097\/j.jcrs.0000000000001432","volume":"50","author":"P Davidova","year":"2024","unstructured":"Davidova, P., Biller, M., Ademmer, V. & Kohnen, T. Pupil size measurements with a multifunctional aberrometer\/coherence interferometer\/tomographer and two infrared-based pupillometers. J. Cataract Refract. Surg. 50 (6), 631\u2013636. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001432 (2024).","journal-title":"J. Cataract Refract. Surg."},{"key":"35975_CR11","doi-asserted-by":"publisher","DOI":"10.1093\/postmj\/qgae181","author":"B Wen","year":"2024","unstructured":"Wen, B. et al. The 2024 revision of the declaration of helsinki: A modern ethical framework for medical research. Postgrad. Med. J. https:\/\/doi.org\/10.1093\/postmj\/qgae181 (2024). (Early Access)).","journal-title":"Postgrad. Med. J."},{"issue":"16","key":"35975_CR12","doi-asserted-by":"publisher","first-page":"e33223","DOI":"10.1097\/MD.0000000000033223","volume":"102","author":"A Simsek","year":"2023","unstructured":"Simsek, A. & Toptan, M. The evaluation of pupil diameter by using Sirius before and after phacoemulsification in healthy, diabetic and hypertension patients. Medicine 102 (16), e33223. https:\/\/doi.org\/10.1097\/MD.0000000000033223 (2023).","journal-title":"Medicine"},{"issue":"1","key":"35975_CR13","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.jcrs.2007.09.013","volume":"34","author":"H Shankar","year":"2008","unstructured":"Shankar, H., Taranath, D., Santhirathelagan, C. T. & Pesudovs, K. Anterior segment biometry with the pentacam: comprehensive assessment of repeatability of automated measurements. J. Cataract Refract. Surg. 34 (1), 103\u2013113. https:\/\/doi.org\/10.1016\/j.jcrs.2007.09.013 (2008).","journal-title":"J. Cataract Refract. Surg."},{"issue":"12","key":"35975_CR14","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1097\/OPX.0000000000002091","volume":"100","author":"B Redondo","year":"2023","unstructured":"Redondo, B. et al. Diurnal variation in accommodation, binocular vergence, and pupil size. Optom. Vis. Sci. 100 (12), 847\u2013854. https:\/\/doi.org\/10.1097\/OPX.0000000000002091 (2023).","journal-title":"Optom. Vis. Sci."},{"issue":"11","key":"35975_CR15","doi-asserted-by":"publisher","first-page":"4632","DOI":"10.1167\/iovs.17-22171","volume":"58","author":"CD Lu","year":"2017","unstructured":"Lu, C. D. et al. Photoreceptor layer thickness changes during dark adaptation observed with ultrahigh-resolution optical coherence tomography. Investig. Ophthalmol. Vis. Sci. 58 (11), 4632\u20134643. https:\/\/doi.org\/10.1167\/iovs.17-22171 (2017).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"issue":"8","key":"35975_CR16","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1136\/bjophthalmol-2019-314947","volume":"104","author":"C Bunce","year":"2020","unstructured":"Bunce, C. et al. Ophthalmic statistics note 14: method agreement studies in ophthalmology: the intraclass correlation coefficient? Br. J. Ophthalmol. 104 (8), 1033\u20131035. https:\/\/doi.org\/10.1136\/bjophthalmol-2019-314947 (2020).","journal-title":"Br. J. Ophthalmol."},{"issue":"3","key":"35975_CR17","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1177\/1536867X231196488","volume":"23","author":"MD Chatfield","year":"2023","unstructured":"Chatfield, M. D. et al. Blandaltman: A command to create variants of bland-altman plots. Stata J. 23 (3), 851\u2013874. https:\/\/doi.org\/10.1177\/1536867X231196488 (2023).","journal-title":"Stata J."},{"issue":"6","key":"35975_CR18","doi-asserted-by":"publisher","first-page":"904","DOI":"10.5301\/ejo.5000150","volume":"22","author":"C Altan","year":"2012","unstructured":"Altan, C. et al. Comparison of 3 pupillometers for determining scotopic pupil diameter. Eur. J. Ophthalmol. 22 (6), 904\u2013910. https:\/\/doi.org\/10.5301\/ejo.5000150 (2012).","journal-title":"Eur. J. Ophthalmol."},{"key":"35975_CR19","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.ajo.2023.05.002","volume":"253","author":"V Romano","year":"2023","unstructured":"Romano, V. et al. Recommendation for presbyopia-correcting intraocular lenses: A Delphi consensus statement by the Esaso study group. Am. J. Ophthalmol. 253, 169\u2013180. https:\/\/doi.org\/10.1016\/j.ajo.2023.05.002 (2023).","journal-title":"Am. J. Ophthalmol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-35975-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-35975-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-35975-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T10:38:57Z","timestamp":1770287937000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-35975-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,12]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["35975"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-35975-8","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,12]]},"assertion":[{"value":"9 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This study was approved by the Ethics Committee of Chongqing Emergency Medical Center(IRB No. 2025-16). All participants provided informed consent and signed consent forms prior to their participation in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical statement"}}],"article-number":"5064"}}