{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T19:49:01Z","timestamp":1791402541411,"version":"4.3.3"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T00:00:00Z","timestamp":1770595200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T00:00:00Z","timestamp":1770681600000},"content-version":"vor","delay-in-days":1,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-37204-8","type":"journal-article","created":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T15:55:00Z","timestamp":1770652500000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Time stability of Intensive Care Infection Score (ICIS) as a cellular hematology biomarker for infection in critically ill patients"],"prefix":"10.1038","volume":"16","author":[{"given":"Noelle","family":"Nacke","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mascha","family":"Zuther","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"H\u00f6nemann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathias","family":"Zimmermann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bastian","family":"Bl\u00f6mer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefanie","family":"Klatte","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jens-Christian","family":"Schewe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6678-7297","authenticated-orcid":false,"given":"Marie-Luise","family":"R\u00fcbsam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,9]]},"reference":[{"key":"37204_CR1","doi-asserted-by":"publisher","first-page":"109","DOI":"10.2174\/187152812800392841","volume":"11","author":"A Nierhaus","year":"2012","unstructured":"Nierhaus, A., Linssen, J., Wichmann, D., Braune, S. & Kluge, S. Use of a weighted, automated analysis of the differential blood count to differentiate sepsis from non-infectious systemic inflammation. Inflamm. Allergy Drug Targets. 11, 109\u2013115 (2012).","journal-title":"Inflamm. Allergy Drug Targets"},{"key":"37204_CR2","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1177\/0300060514557711","volume":"43","author":"K Weimann","year":"2015","unstructured":"Weimann, K. et al. Intensive care infection Score\u2013A new approach to distinguish between infectious and noninfectious processes in intensive care and medicosurgical patients. J. Int. Med. Res. 43, 435\u2013451 (2015).","journal-title":"J. Int. Med. Res."},{"key":"37204_CR3","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1186\/s13054-016-1366-6","volume":"20","author":"PJ van der Geest","year":"2016","unstructured":"van der Geest, P. J. et al. The intensive care infection score - a novel marker for the prediction of infection and its severity. Crit. Care Lond. Engl. 20, 180. https:\/\/doi.org\/10.1186\/s13054-016-1366-6 (2016).","journal-title":"Crit. Care Lond. Engl."},{"key":"37204_CR4","doi-asserted-by":"crossref","unstructured":"Kaeslin, M., Brunner, S., Raths, J. & Huber, A. Improvement in detecting bacterial infection in lower respiratory tract infections using the Intensive Care Infection Score (ICIS). LaboratoriumsMedizin 40, 175\u2013182 (2016).","DOI":"10.1515\/labmed-2016-0021"},{"key":"37204_CR5","doi-asserted-by":"publisher","first-page":"e02004","DOI":"10.1213\/XAA.0000000000002004","volume":"19","author":"N Nacke","year":"2025","unstructured":"Nacke, N., R\u00fcbsam, M. L., Fischer, D. & H\u00f6nemann, C. Exploring the potential of the intensive care infection score in antimicrobial stewardship: A case report. AA Pract. 19, e02004. https:\/\/doi.org\/10.1213\/XAA.0000000000002004 (2025).","journal-title":"AA Pract."},{"key":"37204_CR6","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/j.ebiom.2017.09.024","volume":"24","author":"D Wu","year":"2017","unstructured":"Wu, D., Li, Y. & Wang, F. How long can we store blood samples: A systematic review and Meta-Analysis. EBioMedicine 24, 277\u2013285 (2017).","journal-title":"EBioMedicine"},{"key":"37204_CR7","doi-asserted-by":"publisher","first-page":"5","DOI":"10.11613\/BM.2007.001","volume":"17","author":"M Plebani","year":"2007","unstructured":"Plebani, M. Laboratory errors: how to improve pre- and post-analytical phases? Biochem. Med. 17, 5\u20139 (2007).","journal-title":"Biochem. Med."},{"key":"37204_CR8","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1001\/jama.2016.0287","volume":"315","author":"M Singer","year":"2016","unstructured":"Singer, M. et al. The third international consensus definitions for sepsis and septic shock (Sepsis-3). JAMA 315, 801. https:\/\/doi.org\/10.1001\/jama.2016.0287 (2016).","journal-title":"JAMA"},{"key":"37204_CR9","doi-asserted-by":"publisher","unstructured":"Zuther, M., R\u00fcbsam, M. L., Zimmermann, M., Zarbock, A. & H\u00f6nemann, C. Improved diagnosis of iron deficiency anemia in the critically ill via fluorescence flowcytometric hemoglobin biomarkers. Cells 12, 140. https:\/\/doi.org\/10.3390\/cells12010140 (2022).","DOI":"10.3390\/cells12010140"},{"key":"37204_CR10","doi-asserted-by":"publisher","first-page":"247","DOI":"10.3109\/00365513.2014.1000370","volume":"75","author":"\u00c5A Sudmann-Day","year":"2015","unstructured":"Sudmann-Day, \u00c5. A., Piehler, A., Klingenberg, O. & Urdal, P. Six-day stability of erythrocyte and reticulocyte parameters in-vitro: A comparison of blood samples from healthy, iron-deficient, and thalassemic individuals. Scand. J. Clin. Lab. Invest. 75, 247\u2013253 (2015).","journal-title":"Scand. J. Clin. Lab. Invest."},{"key":"37204_CR11","first-page":"147","volume":"38","author":"SB Hong","year":"2006","unstructured":"Hong, S. B., Kim, J. S. & Shin, K. S. The effect of the storage duration and temperature of EDTA specimen for CBC and WBC differential count in SE-9000 automated cell counter. Korean J. Clin. Lab. Sci. 38, 147\u2013151 (2006).","journal-title":"Korean J. Clin. Lab. Sci."},{"key":"37204_CR12","first-page":"276","volume":"13","author":"M Daves","year":"2015","unstructured":"Daves, M. et al. Sample stability for complete blood cell count using the sysmex XN haematological analyser. Blood Transfus. 13, 276\u2013282 (2015).","journal-title":"Blood Transfus."},{"key":"37204_CR13","doi-asserted-by":"publisher","first-page":"252","DOI":"10.5937\/jomb0-27945","volume":"40","author":"O Unalli","year":"2021","unstructured":"Unalli, O. & Ozarda, Y. Stability of hematological analytes during 48 hours storage at three temperatures using Cell-Dyn hematology analyzer. J. Med. Biochem. 40, 252\u2013260 (2021).","journal-title":"J. Med. Biochem."},{"key":"37204_CR14","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1111\/ijlh.12389","volume":"37","author":"A Joshi","year":"2015","unstructured":"Joshi, A. et al. Determining the stability of complete blood count parameters in stored blood samples using the SYSMEX XE -5000 automated haematology analyser. Int. J. Lab. Hematol. 37, 705\u2013714 (2015).","journal-title":"Int. J. Lab. Hematol."},{"key":"37204_CR15","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1111\/ijlh.12170","volume":"36","author":"J Vives-Corrons","year":"2014","unstructured":"Vives-Corrons, J. et al. Effect of EDTA \u2010anticoagulated whole blood storage on cell morphology examination. A need for standardization. Int. J. Lab. Hematol. 36, 222\u2013226 (2014).","journal-title":"Int. J. Lab. Hematol."},{"key":"37204_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/vox.12130","volume":"107","author":"JR Hess","year":"2014","unstructured":"Hess, J. R. Measures of stored red blood cell quality. Vox Sang. 107, 1\u20139 (2014).","journal-title":"Vox Sang"},{"key":"37204_CR17","doi-asserted-by":"publisher","first-page":"161","DOI":"10.3233\/CH-131682","volume":"56","author":"SA Reinhart","year":"2014","unstructured":"Reinhart, S. A., Schulzki, T., Bonetti, P. O. & Reinhart, W. H. Studies on metabolically depleted erythrocytes. Clin. Hemorheol Microcirc. 56, 161\u2013173 (2014).","journal-title":"Clin. Hemorheol Microcirc"},{"key":"37204_CR18","doi-asserted-by":"publisher","first-page":"288","DOI":"10.3389\/fphys.2016.00288","volume":"7","author":"A Makhro","year":"2016","unstructured":"Makhro, A. et al. Red cell properties after different modes of blood transportation. Front. Physiol. 7, 288. https:\/\/doi.org\/10.3389\/fphys.2016.00288 (2016).","journal-title":"Front. Physiol."},{"key":"37204_CR19","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.cccn.2004.02.038","volume":"346","author":"M Buttarello","year":"2004","unstructured":"Buttarello, M. Quality specification in haematology: the automated blood cell count. Clin. Chim. Acta. 346, 45\u201354 (2004).","journal-title":"Clin. Chim. Acta"},{"key":"37204_CR20","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1532\/LH96.08005","volume":"14","author":"SC Voss","year":"2008","unstructured":"Voss, S. C., Flenker, U., Majer, B. & Sch\u00e4nzer, W. Stability tests for hematological parameters in antidoping analyses. Lab. Hematol. 14, 24\u201329 (2008).","journal-title":"Lab. Hematol."},{"key":"37204_CR21","doi-asserted-by":"publisher","first-page":"e0301845","DOI":"10.1371\/journal.pone.0301845","volume":"19","author":"A \u00c5strand","year":"2024","unstructured":"\u00c5strand, A. et al. A comparative study of blood cell count in four automated hematology analyzers: an evaluation of the impact of preanalytical factors. PLOS ONE. 19, e0301845. https:\/\/doi.org\/10.1371\/journal.pone.0301845 (2024).","journal-title":"PLOS ONE"},{"key":"37204_CR22","first-page":"14","volume":"18","author":"M Mahmoodi","year":"2006","unstructured":"Mahmoodi, M. et al. Survey of changes in complete blood count and red cell indices of whole blood incubated in vitro at different temperatures up to 48 hours. J. Ayub Med. Coll. Abbottabad JAMC. 18, 14\u201316 (2006).","journal-title":"J. Ayub Med. Coll. Abbottabad JAMC"},{"key":"37204_CR23","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1038\/labinvest.3780267","volume":"81","author":"E Maurer-Spurej","year":"2001","unstructured":"Maurer-Spurej, E. et al. Room temperature activates human blood platelets. Lab. Invest. 81, 581\u2013592 (2001).","journal-title":"Lab. Invest."},{"key":"37204_CR24","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1515\/labmed-2020-0037","volume":"44","author":"S Mannu\u00df","year":"2020","unstructured":"Mannu\u00df, S. Influence of different methods and anticoagulants on platelet parameter measurement. J. Lab. Med. 44, 255\u2013272 (2020).","journal-title":"J. Lab. Med."},{"key":"37204_CR25","doi-asserted-by":"publisher","first-page":"1000220","DOI":"10.4172\/2157-7013.1000220","volume":"06","author":"A Tendulkar","year":"2015","unstructured":"Tendulkar, A. et al. Stability of selected hematological parameters in stored blood samples. J. Cell. Sci. Ther. 06, 1000220. https:\/\/doi.org\/10.4172\/2157-7013.1000220 (2015).","journal-title":"J. Cell. Sci. Ther."},{"key":"37204_CR26","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1111\/ijlh.12181","volume":"36","author":"G Zini","year":"2014","unstructured":"Zini, G. & International Council for Standardization in Haematology (ICSH). Stability of complete blood count parameters with storage: toward defined specifications for different diagnostic applications. Int. J. Lab. Hematol. 36, 111\u2013113 (2014).","journal-title":"Int. J. Lab. Hematol."},{"key":"37204_CR27","doi-asserted-by":"publisher","first-page":"336","DOI":"10.5858\/2002-126-0336-CIACBC","volume":"126","author":"GL Gulati","year":"2002","unstructured":"Gulati, G. L., Hyland, L. J., Kocher, W. & Schwarting, R. Changes in automated complete blood cell count and differential leukocyte count results induced by storage of blood at room temperature. Arch. Pathol. Lab. Med. 126, 336\u2013342 (2002).","journal-title":"Arch. Pathol. Lab. Med."},{"key":"37204_CR28","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/S1537-1891(02)00298-7","volume":"39","author":"SA Vogelaar","year":"2002","unstructured":"Vogelaar, S. A., Posthuma, D., Boomsma, D. & Kluft, C. Blood sample stability at room temperature for counting red and white blood cells and platelets. Vascul Pharmacol. 39, 123\u2013125 (2002).","journal-title":"Vascul Pharmacol."},{"key":"37204_CR29","unstructured":"Sysmex Corporation. Automated Hematology Analyzer XN Series (XN-2000). (2024). https:\/\/www.sysmex.de\/produkte\/details\/xn-2000\/"},{"key":"37204_CR30","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1016\/j.bjhh.2016.05.010","volume":"38","author":"S Buoro","year":"2016","unstructured":"Buoro, S. et al. Assessment of blood sample stability for complete blood count using the sysmex XN-9000 and mindray BC-6800 analyzers. Rev. Bras. Hematol. E Hemoter. 38, 225\u2013239 (2016).","journal-title":"Rev. Bras. Hematol. E Hemoter"},{"key":"37204_CR31","doi-asserted-by":"publisher","first-page":"112616","DOI":"10.1016\/j.jim.2019.06.007","volume":"475","author":"AM Diks","year":"2019","unstructured":"Diks, A. M. et al. Impact of blood storage and sample handling on quality of high dimensional flow cytometric data in multicenter clinical research. J. Immunol. Methods. 475, 112616. https:\/\/doi.org\/10.1016\/j.jim.2019.06.007 (2019).","journal-title":"J. Immunol. Methods"},{"key":"37204_CR32","doi-asserted-by":"publisher","first-page":"21","DOI":"10.19186\/BC_2016.021","volume":"40","author":"T Mecca","year":"2016","unstructured":"Mecca, T. et al. Valutazione analitica Della Misura Di Nuovi parametri emocitometrici Su analizzatore sysmex XN-9000. Biochim. Clin. 40, 21. https:\/\/doi.org\/10.19186\/BC_2016.021 (2016).","journal-title":"Biochim. Clin."},{"key":"37204_CR33","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1309\/TVGKD5TVB7W9HHC7","volume":"128","author":"B Fernandes","year":"2007","unstructured":"Fernandes, B. & Hamaguchi, Y. Automated enumeration of immature granulocytes. Am. J. Clin. Pathol. 128, 454\u2013463 (2007).","journal-title":"Am. J. Clin. Pathol."},{"key":"37204_CR34","first-page":"117","volume":"9","author":"C Briggs","year":"2003","unstructured":"Briggs, C. et al. Evaluation of immature granulocyte counts by the XE-IG master: upgraded software for the XE-2100 automated hematology analyzer. Lab. Hematol. Off Publ Int. Soc. Lab. Hematol. 9, 117\u2013124 (2003).","journal-title":"Lab. Hematol. Off Publ Int. Soc. Lab. Hematol."},{"key":"37204_CR35","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.jim.2008.10.019","volume":"341","author":"KC McKenna","year":"2009","unstructured":"McKenna, K. C., Beatty, K. M., Miguel, V., Bilonick, R. A. & R. & Delayed processing of blood increases the frequency of activated CD11b\u2009+\u2009CD15\u2009+\u2009granulocytes which inhibit T cell function. J. Immunol. Methods. 341, 68\u201375 (2009).","journal-title":"J. Immunol. Methods"},{"key":"37204_CR36","doi-asserted-by":"publisher","unstructured":"Chang, S. T. et al. Age-dependent immune profile in healthy individuals: an original study, systematic review and meta-analysis. Immun. Ageing. 21, 75. https:\/\/doi.org\/10.1186\/s12979-024-00480-x (2024).","DOI":"10.1186\/s12979-024-00480-x"},{"key":"37204_CR37","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1186\/s12891-016-1135-3","volume":"17","author":"DL Fleishaker","year":"2016","unstructured":"Fleishaker, D. L., Mukherjee, A., Whaley, F. S., Daniel, S. & Zeiher, B. G. Safety and pharmacodynamic dose response of short-term prednisone in healthy adult subjects: a dose ranging, randomized, placebo-controlled, crossover study. BMC Musculoskelet. Disord. 17, 293. https:\/\/doi.org\/10.1186\/s12891-016-1135-3 (2016).","journal-title":"BMC Musculoskelet. Disord"},{"key":"37204_CR38","doi-asserted-by":"publisher","first-page":"1224","DOI":"10.1210\/jcem-64-6-1224","volume":"64","author":"R Hiramatsu","year":"1987","unstructured":"Hiramatsu, R. & Nisula, B. C. Erythrocyte-Associated cortisol: Measurement, kinetics of Dissociation, and potential physiological significance. J. Clin. Endocrinol. Metab. 64, 1224\u20131232 (1987).","journal-title":"J. Clin. Endocrinol. Metab."},{"key":"37204_CR39","doi-asserted-by":"publisher","first-page":"5347","DOI":"10.1182\/blood-2010-04-277319","volume":"116","author":"F Vallelian","year":"2010","unstructured":"Vallelian, F. et al. Glucocorticoid treatment skews human monocyte differentiation into a hemoglobin-clearance phenotype with enhanced heme-iron recycling and antioxidant capacity. Blood 116, 5347\u20135356 (2010).","journal-title":"Blood"},{"key":"37204_CR40","doi-asserted-by":"publisher","first-page":"e31067","DOI":"10.7759\/cureus.31067","volume":"14","author":"J Hassan","year":"2022","unstructured":"Hassan, J. et al. Role of procalcitonin and C-reactive protein as predictors of sepsis and in managing sepsis in postoperative patients: A systematic review. Cureus 14, e31067. https:\/\/doi.org\/10.7759\/cureus.31067 (2022).","journal-title":"Cureus"},{"key":"37204_CR41","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1007\/s00134-022-06956-y","volume":"49","author":"P P\u00f3voa","year":"2023","unstructured":"P\u00f3voa, P. et al. How to use biomarkers of infection or sepsis at the bedside: guide to clinicians. Intensive Care Med. 49, 142\u2013153 (2023).","journal-title":"Intensive Care Med."},{"key":"37204_CR42","doi-asserted-by":"publisher","first-page":"603","DOI":"10.3109\/00365513.2014.928940","volume":"74","author":"LO Henriksen","year":"2014","unstructured":"Henriksen, L. O., Faber, N. R., Moller, M. F., Nexo, E. & Hansen, A. B. Stability of 35 biochemical and immunological routine tests after 10 hours storage and transport of human whole blood at 21\u00b0C. Scand. J. Clin. Lab. Invest. 74, 603\u2013610 (2014).","journal-title":"Scand. J. Clin. Lab. Invest."},{"key":"37204_CR43","doi-asserted-by":"publisher","first-page":"020708","DOI":"10.11613\/BM.2019.020708","volume":"29","author":"RA Abraham","year":"2019","unstructured":"Abraham, R. A. et al. Effect of temperature and time delay in centrifugation on stability of select biomarkers of nutrition and non-communicable diseases in blood samples. Biochem. Med. 29, 020708. https:\/\/doi.org\/10.11613\/BM.2019.020708 (2019).","journal-title":"Biochem. Med."},{"key":"37204_CR44","first-page":"911","volume":"52","author":"KM Goode","year":"2014","unstructured":"Goode, K. M., Nicholls, R., Pellicori, P., Clark, A. L. & Cleland, J. G. F. The in vitro stability of novel cardiovascular and sepsis biomarkers at ambient temperature. Clin. Chem. Lab. Med. CCLM. 52, 911\u2013918 (2014).","journal-title":"Clin. Chem. Lab. Med. CCLM"},{"key":"37204_CR45","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1186\/s13054-019-2511-9","volume":"23","author":"NS Whitehead","year":"2019","unstructured":"Whitehead, N. S. et al. Interventions to prevent iatrogenic anemia: a laboratory medicine best practices systematic review. Crit. Care. 23, 278. https:\/\/doi.org\/10.1186\/s13054-019-2511-9 (2019).","journal-title":"Crit. Care"},{"key":"37204_CR46","unstructured":"Cohen, J. & Effect size in Statistical Power Analysis for the Behavioral Sciences (eb. Cohen, J) 4\u201318L. Erlbaum Associates, (1988)."},{"key":"37204_CR47","first-page":"1161","volume":"53","author":"R Haeckel","year":"2015","unstructured":"Haeckel, R., Wosniok, W., Gurr, E. & Peil, B. Permissible limits for uncertainty of measurement in laboratory medicine. Clin. Chem. Lab. Med. CCLM. 53, 1161\u20131171 (2015).","journal-title":"Clin. Chem. Lab. Med. CCLM"},{"key":"37204_CR48","unstructured":"Deutsche Gesellschaft f\u00fcr Klinische Chemie und Laboratoriumsmedizin e.V. Zul\u00e4ssige Impr\u00e4zision (pCVA) und kombinierte Messunsicherheit (pU%) f\u00fcr einen bestimmten Messwert (xi). Vergleich des aktuellen Vorschlags mit den Angaben der RiliB\u00c4K. (2021). https:\/\/dgkl.de\/die-dgkl\/kompetenzfelder\/entscheidungsgrenzen-und-richtgrenzen\/"},{"key":"37204_CR49","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1515\/cclm-2022-0094","volume":"60","author":"L Van Pelt","year":"2022","unstructured":"Van Pelt, L. Reference intervals for sysmex XN hematological parameters as assessed in the Dutch lifelines cohort. Clin. Chem. Lab. Med. CCLM. 60, 907\u2013920 (2022).","journal-title":"Clin. Chem. Lab. Med. CCLM"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-37204-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-37204-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-37204-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T22:06:27Z","timestamp":1770761187000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-37204-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,9]]},"references-count":49,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["37204"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-37204-8","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,9]]},"assertion":[{"value":"8 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was conducted in accordance with the ethical principles decreed by the Declaration of Helsinki and its later amendments and in compliance with International Conference on Harmonization Good Clinical Practice Guidelines. The institutional ethics committee of the Medical Association of Lower Saxony, Germany, reviewed and approved the study protocol and the informed consent document (Ref: Bo\/08\/2021, 06.04.2021).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from all patients or their legal authorized representative prior to the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Financial interests: Noelle Nacke, Mascha Zuther, Christian H\u00f6nemann, Mathias Zimmermann, and Marie-Luise R\u00fcbsam have received speaker honorarium from Sysmex Deutschland GmbH. Christian H\u00f6nemann has received speaker honorarium from CSL Vifor Germany. Stefanie Klatte receives salary from Sysmex Europe SE. Non-financial interests: none.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"5620"}}