{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T23:51:56Z","timestamp":1781653916228,"version":"3.54.5"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T00:00:00Z","timestamp":1776816000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T00:00:00Z","timestamp":1781654400000},"content-version":"vor","delay-in-days":56,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["82371098"],"award-info":[{"award-number":["82371098"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Chongqing medical scientific research project","award":["2024ZDXM033"],"award-info":[{"award-number":["2024ZDXM033"]}]},{"DOI":"10.13039\/501100018543","name":"the Natural Science Foundation of Tibet Autonomous Region","doi-asserted-by":"crossref","award":["XZ22025ZR-ZY080(Z)"],"award-info":[{"award-number":["XZ22025ZR-ZY080(Z)"]}],"id":[{"id":"10.13039\/501100018543","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-42117-7","type":"journal-article","created":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T14:55:20Z","timestamp":1776869720000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of a swept-source optical coherence tomograph device (MT9000) to a partial coherence interferometry-based biometer (IOLMaster 500) in a high-altitude environment"],"prefix":"10.1038","volume":"16","author":[{"given":"Yonglin","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rong","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongguo","family":"Xiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liang","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan","family":"Kang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuren","family":"Pan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ke","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shijie","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,22]]},"reference":[{"key":"42117_CR1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm13154400","author":"W Stopyra","year":"2024","unstructured":"Stopyra, W. & Grzybowski, A. Intraocular lens power calculation formulas in children-a systematic review. J. Clin. Med. https:\/\/doi.org\/10.3390\/jcm13154400 (2024).","journal-title":"J. Clin. Med."},{"issue":"3","key":"42117_CR2","doi-asserted-by":"publisher","first-page":"201","DOI":"10.4274\/tjo.galenos.2021.83704","volume":"52","author":"W Stopyra","year":"2022","unstructured":"Stopyra, W. Effectiveness, sensitivity, and specificity of intraocular lens power calculation formulas for short eyes. Turk. J. Ophthalmol. 52 (3), 201\u2013207. https:\/\/doi.org\/10.4274\/tjo.galenos.2021.83704 (2022).","journal-title":"Turk. J. Ophthalmol."},{"issue":"1","key":"42117_CR3","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-025-03543-0","volume":"45","author":"DY Xu","year":"2025","unstructured":"Xu, D. Y. & Wang, J. Factors affecting the refractive error after cataract surgery. Int. Ophthalmol. 45 (1), 163. https:\/\/doi.org\/10.1007\/s10792-025-03543-0 (2025).","journal-title":"Int. Ophthalmol."},{"key":"42117_CR4","doi-asserted-by":"publisher","DOI":"10.3390\/life15010045","author":"W Stopyra","year":"2025","unstructured":"Stopyra, W., Voytsekhivskyy, O. & Grzybowski, A. Prediction of seven artificial intelligence-based intraocular lens power calculation formulas in medium-long Caucasian eyes. Life https:\/\/doi.org\/10.3390\/life15010045 (2025).","journal-title":"Life"},{"issue":"7","key":"42117_CR5","doi-asserted-by":"publisher","first-page":"972","DOI":"10.1016\/j.ophtha.2018.01.021","volume":"125","author":"V Kansal","year":"2018","unstructured":"Kansal, V., Schlenker, M. & Ahmed, I. I. K. Interocular axial length and corneal power differences as predictors of postoperative refractive outcomes after cataract surgery. Ophthalmology 125 (7), 972\u2013981. https:\/\/doi.org\/10.1016\/j.ophtha.2018.01.021 (2018).","journal-title":"Ophthalmology"},{"issue":"9","key":"42117_CR6","doi-asserted-by":"publisher","first-page":"1236","DOI":"10.1097\/j.jcrs.0000000000000235","volume":"46","author":"JX Kane","year":"2020","unstructured":"Kane, J. X. & Melles, R. B. Intraocular lens formula comparison in axial hyperopia with a high-power intraocular lens of 30 or more diopters. J. Cataract Refract. Surg. 46 (9), 1236\u20131239. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000235 (2020).","journal-title":"J. Cataract Refract. Surg."},{"key":"42117_CR7","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1016\/j.ajo.2023.09.009","volume":"257","author":"Y Ma","year":"2024","unstructured":"Ma, Y. et al. Network meta-analysis of intraocular lens power calculation formula accuracy in 1016 eyes with long axial length. Am. J. Ophthalmol. 257, 178\u2013186. https:\/\/doi.org\/10.1016\/j.ajo.2023.09.009 (2024).","journal-title":"Am. J. Ophthalmol."},{"issue":"1","key":"42117_CR8","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-93999-8","volume":"11","author":"TCY Chan","year":"2021","unstructured":"Chan, T. C. Y. et al. Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer. Sci. Rep. 11 (1), 14853. https:\/\/doi.org\/10.1038\/s41598-021-93999-8 (2021).","journal-title":"Sci. Rep."},{"issue":"11","key":"42117_CR9","doi-asserted-by":"publisher","first-page":"2387","DOI":"10.1016\/j.jcrs.2015.05.028","volume":"41","author":"S Goebels","year":"2015","unstructured":"Goebels, S. et al. Comparison of 3 biometry devices in cataract patients. J. Cataract Refract. Surg. 41 (11), 2387\u20132393. https:\/\/doi.org\/10.1016\/j.jcrs.2015.05.028 (2015).","journal-title":"J. Cataract Refract. Surg."},{"issue":"4","key":"42117_CR10","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1016\/j.jcrs.2013.09.015","volume":"40","author":"G Kaswin","year":"2014","unstructured":"Kaswin, G., Rousseau, A., Mgarrech, M., Barreau, E. & Labetoulle, M. Biometry and intraocular lens power calculation results with a new optical biometry device: Comparison with the gold standard. J. Cataract Refract. Surg. 40 (4), 593\u2013600. https:\/\/doi.org\/10.1016\/j.jcrs.2013.09.015 (2014).","journal-title":"J. Cataract Refract. Surg."},{"issue":"7","key":"42117_CR11","doi-asserted-by":"publisher","first-page":"1244","DOI":"10.1038\/s41433-018-0063-x","volume":"32","author":"O Reitblat","year":"2018","unstructured":"Reitblat, O., Levy, A., Kleinmann, G. & Assia, E. I. Accuracy of intraocular lens power calculation using three optical biometry measurement devices: the OA-2000, Lenstar-LS900 and IOLMaster-500. Eye (Lond.) 32 (7), 1244\u20131252. https:\/\/doi.org\/10.1038\/s41433-018-0063-x (2018).","journal-title":"Eye (Lond.)"},{"issue":"Pt B","key":"42117_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.envres.2022.113214","volume":"212","author":"P Song","year":"2022","unstructured":"Song, P. et al. High altitude relieves transmission risks of COVID-19 through meteorological and environmental factors: Evidence from China. Environ. Res. 212 (Pt B), 113214. https:\/\/doi.org\/10.1016\/j.envres.2022.113214 (2022).","journal-title":"Environ. Res."},{"issue":"2","key":"42117_CR13","doi-asserted-by":"publisher","first-page":"237","DOI":"10.3980\/j.issn.2222-3959.2013.02.24","volume":"6","author":"GQ Wang","year":"2013","unstructured":"Wang, G. Q. et al. Prevalence and risk factors for eye diseases, blindness, and low vision in Lhasa, Tibet. Int. J. Ophthalmol. 6 (2), 237\u2013241. https:\/\/doi.org\/10.3980\/j.issn.2222-3959.2013.02.24 (2013).","journal-title":"Int. J. Ophthalmol."},{"issue":"4","key":"42117_CR14","doi-asserted-by":"publisher","first-page":"1483","DOI":"10.4103\/ijo.Ijo_2657_22","volume":"71","author":"Z Li","year":"2023","unstructured":"Li, Z., Wan, W., Ji, Y., Zheng, S. & Hu, K. Functional and morphological evaluation of the meibomian glands and ocular surface assessment at high altitude. Indian J. Ophthalmol. 71 (4), 1483\u20131487. https:\/\/doi.org\/10.4103\/ijo.Ijo_2657_22 (2023).","journal-title":"Indian J. Ophthalmol."},{"issue":"4","key":"42117_CR15","doi-asserted-by":"publisher","first-page":"610","DOI":"10.18240\/ijo.2016.04.23","volume":"9","author":"JM Yu","year":"2016","unstructured":"Yu, J. M. et al. Prevalence and risk factors of lens opacities in rural populations living at two different altitudes in China. Int. J. Ophthalmol. 9 (4), 610\u2013616. https:\/\/doi.org\/10.18240\/ijo.2016.04.23 (2016).","journal-title":"Int. J. Ophthalmol."},{"key":"42117_CR16","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2025.1565740","volume":"12","author":"X Zhang","year":"2025","unstructured":"Zhang, X. et al. Reproducibility and accuracy of corneal curvature measurements in patients with and without dry eye: A device-based study. Front. Med. 12, 1565740. https:\/\/doi.org\/10.3389\/fmed.2025.1565740 (2025).","journal-title":"Front. Med."},{"issue":"Suppl 3","key":"42117_CR17","doi-asserted-by":"publisher","first-page":"S398","DOI":"10.4103\/ijo.Ijo_907_23","volume":"72","author":"O Albis-Donado","year":"2024","unstructured":"Albis-Donado, O., Ramirez-Neria, P., Rios-Acosta, N. & Stalmans, I. The influence of altitude on the differences between Goldmann tonometry and Pascal dynamic contour tonometry: an ecological meta-analysis. Indian J. Ophthalmol. 72 (Suppl 3), S398-s403. https:\/\/doi.org\/10.4103\/ijo.Ijo_907_23 (2024).","journal-title":"Indian J. Ophthalmol."},{"issue":"2","key":"42117_CR18","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo, T. K. & Li, M. Y. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 15 (2), 155\u2013163. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012 (2016).","journal-title":"J. Chiropr. Med."},{"issue":"1","key":"42117_CR19","doi-asserted-by":"publisher","DOI":"10.1186\/s41747-024-00474-w","volume":"8","author":"CB Monti","year":"2024","unstructured":"Monti, C. B., Ambrogi, F. & Sardanelli, F. Sample size calculation for data reliability and diagnostic performance: a go-to review. Eur. Radiol. Exp. 8 (1), 79. https:\/\/doi.org\/10.1186\/s41747-024-00474-w (2024).","journal-title":"Eur. Radiol. Exp."},{"issue":"1","key":"42117_CR20","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1002\/(sici)1097-0258(19980115)17:1<101::aid-sim727>3.0.co;2-e","volume":"17","author":"SD Walter","year":"1998","unstructured":"Walter, S. D., Eliasziw, M. & Donner, A. Sample size and optimal designs for reliability studies. Stat. Med. 17 (1), 101\u2013110. https:\/\/doi.org\/10.1002\/(sici)1097-0258(19980115)17:1%3c101::aid-sim727%3e3.0.co;2-e (1998).","journal-title":"Stat. Med."},{"issue":"9","key":"42117_CR21","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1136\/bjophthalmol-2015-307779","volume":"100","author":"A Akman","year":"2016","unstructured":"Akman, A., Asena, L. & G\u00fcng\u00f6r, S. G. Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500. Br. J. Ophthalmol. 100 (9), 1201\u20131205. https:\/\/doi.org\/10.1136\/bjophthalmol-2015-307779 (2016).","journal-title":"Br. J. Ophthalmol."},{"issue":"7","key":"42117_CR22","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.18240\/ijo.2021.07.08","volume":"14","author":"Q Shi","year":"2021","unstructured":"Shi, Q., Wang, G. Y., Cheng, Y. H. & Pei, C. Comparison of IOL-Master 700 and IOL-Master 500 biometers in ocular biological parameters of adolescents. Int. J. Ophthalmol. 14 (7), 1013\u20131017. https:\/\/doi.org\/10.18240\/ijo.2021.07.08 (2021).","journal-title":"Int. J. Ophthalmol."},{"key":"42117_CR23","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1016\/j.ajo.2016.09.019","volume":"173","author":"C McAlinden","year":"2017","unstructured":"McAlinden, C. et al. Axial length measurement failure rates with biometers using swept-source optical coherence tomography compared to partial-coherence interferometry and optical low-coherence interferometry. Am. J. Ophthalmol. 173, 64\u201369. https:\/\/doi.org\/10.1016\/j.ajo.2016.09.019 (2017).","journal-title":"Am. J. Ophthalmol."},{"issue":"1","key":"42117_CR24","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-023-02926-0","volume":"23","author":"P Kanclerz","year":"2023","unstructured":"Kanclerz, P., Hecht, I. & Tuuminen, R. Technical failure rates for biometry between swept-source and older-generation optical coherence methods: a review and meta-analysis. BMC Ophthalmol. 23 (1), 182. https:\/\/doi.org\/10.1186\/s12886-023-02926-0 (2023).","journal-title":"BMC Ophthalmol."},{"key":"42117_CR25","unstructured":"Arifin, W. N. Sample size calculator (web). http:\/\/wnarifin.github.io\/ (2025)."},{"key":"42117_CR26","doi-asserted-by":"publisher","DOI":"10.3390\/jcm11030710","author":"T Hiraoka","year":"2022","unstructured":"Hiraoka, T. et al. Influence of dry eye disease on the measurement repeatability of corneal curvature radius and axial length in patients with cataract. J. Clin. Med. https:\/\/doi.org\/10.3390\/jcm11030710 (2022).","journal-title":"J. Clin. Med."},{"issue":"2","key":"42117_CR27","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.aopr.2025.02.001","volume":"5","author":"Y Jiang","year":"2025","unstructured":"Jiang, Y. et al. Impact of tear film stability on corneal refractive power measurement and surgical planning for cataract. Adv. Ophthalmol. Pract. Res. 5 (2), 100\u2013106. https:\/\/doi.org\/10.1016\/j.aopr.2025.02.001 (2025).","journal-title":"Adv. Ophthalmol. Pract. Res."},{"issue":"8","key":"42117_CR28","doi-asserted-by":"publisher","first-page":"557","DOI":"10.3928\/1081597x-20200612-03","volume":"36","author":"SA Vasavada","year":"2020","unstructured":"Vasavada, S. A. et al. Comparison of optical low-coherence reflectometry and swept-source OCT-based biometry devices in dense cataracts. J. Refract. Surg. 36 (8), 557\u2013564. https:\/\/doi.org\/10.3928\/1081597x-20200612-03 (2020).","journal-title":"J. Refract. Surg."},{"issue":"2","key":"42117_CR29","doi-asserted-by":"publisher","first-page":"115","DOI":"10.3928\/1081597x-20190109-01","volume":"35","author":"J Huang","year":"2019","unstructured":"Huang, J. et al. Comprehensive comparison of axial length measurement with three swept-source OCT-based biometers and partial coherence interferometry. J. Refract. Surg. 35 (2), 115\u2013120. https:\/\/doi.org\/10.3928\/1081597x-20190109-01 (2019).","journal-title":"J. Refract. Surg."},{"issue":"3","key":"42117_CR30","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1007\/s00417-018-3909-9","volume":"256","author":"JA Calvo-Sanz","year":"2018","unstructured":"Calvo-Sanz, J. A., Portero-Benito, A. & Arias-Puente, A. Efficiency and measurements agreement between swept-source OCT and low-coherence interferometry biometry systems. Graefes Arch. Clin. Exp. Ophthalmol. 256 (3), 559\u2013566. https:\/\/doi.org\/10.1007\/s00417-018-3909-9 (2018).","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"issue":"5","key":"42117_CR31","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1111\/j.1600-0420.2007.00879.x","volume":"85","author":"T Olsen","year":"2007","unstructured":"Olsen, T. Calculation of intraocular lens power: a review. Acta Ophthalmol. Scand. 85 (5), 472\u2013485. https:\/\/doi.org\/10.1111\/j.1600-0420.2007.00879.x (2007).","journal-title":"Acta Ophthalmol. Scand."},{"issue":"10","key":"42117_CR32","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0223114","volume":"14","author":"CM Yang","year":"2019","unstructured":"Yang, C. M., Lim, D. H., Kim, H. J. & Chung, T. Y. Comparison of two swept-source optical coherence tomography biometers and a partial coherence interferometer. PLoS ONE 14 (10), e0223114. https:\/\/doi.org\/10.1371\/journal.pone.0223114 (2019).","journal-title":"PLoS ONE"},{"issue":"3","key":"42117_CR33","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.jcrs.2007.10.031","volume":"34","author":"S Norrby","year":"2008","unstructured":"Norrby, S. Sources of error in intraocular lens power calculation. J. Cataract Refract. Surg. 34 (3), 368\u2013376. https:\/\/doi.org\/10.1016\/j.jcrs.2007.10.031 (2008).","journal-title":"J. Cataract Refract. Surg."},{"issue":"1","key":"42117_CR34","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-021-02129-5","volume":"21","author":"J Kim","year":"2021","unstructured":"Kim, J., Kim, M. K., Ha, Y., Paik, H. J. & Kim, D. H. Improved accuracy of intraocular lens power calculation by preoperative management of dry eye disease. BMC Ophthalmol. 21 (1), 364. https:\/\/doi.org\/10.1186\/s12886-021-02129-5 (2021).","journal-title":"BMC Ophthalmol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42117-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42117-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42117-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T22:55:04Z","timestamp":1781650504000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42117-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,22]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["42117"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-42117-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,22]]},"assertion":[{"value":"28 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The study adhered to the Declaration of Helsinki or relevant guidelines and regulations and was approved by the Ethics Committee of the People\u2019s Hospital of Qamdo, Tibet (No. 2025007). Written informed consent to participate in this study was provided by the participants\/next of kin.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}],"article-number":"18756"}}