{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T01:51:47Z","timestamp":1793325107248,"version":"4.5.0"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T00:00:00Z","timestamp":1773878400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T00:00:00Z","timestamp":1777939200000},"content-version":"vor","delay-in-days":47,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Industrial activities rely on centrifugal pumps for fluid movement in numerous processes, including water treatment plants and chemical processing plants. These pumps must be used to precisely transfer the specific fluid level in tanks in order for operations to be stable and effective. Nevertheless, typical Proportional Integral Derivative (PID) controllers have the potential to deal with these types of problems, and the feedback measurement is based on sensors. Also, in industrial process control systems, where exact information is vital for maintaining stability and performance across applications, sensor faults are a significant challenge to address. Any issue with the level-measuring sensor could cause unnecessary downtime and incorrect production, which could have a big impact on the control loop. For such systems, this paper suggests a Fault-Tolerant Control (FTC) approach that actively estimates faulty sensor data in real-time using a Fault Detection and Isolation (FDI) estimator. The FDI unit of system estimates a value based on data from other operating sensors in the case of one sensor fault. The results show that the suggested strategy is an effective approach to keep the pump running even if the sensor fails. The control loop is based on an estimate from the FDI unit; thus, it continues to operate even if a sensor fails. Given the numerous industrial applications for centrifugal pumps, the suggested approach guarantees improved efficiency and fault tolerance.<\/jats:p>","DOI":"10.1038\/s41598-026-42361-x","type":"journal-article","created":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T08:57:05Z","timestamp":1773910625000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Design of a fault-tolerant control system for a centrifugal pump-based level control system for sensor faults"],"prefix":"10.1038","volume":"16","author":[{"given":"Muhammad","family":"Irfan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arslan Ahmed","family":"Amin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saba","family":"Waseem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saifur","family":"Rahman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hatim","family":"Alwadie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saleh","family":"Al Dawsari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,19]]},"reference":[{"issue":"1","key":"42361_CR1","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.arcontrol.2012.03.005","volume":"36","author":"J Jiang","year":"2012","unstructured":"Jiang, J. & Yu, X. Fault-tolerant control systems: A comparative study between active and passive approaches. Annu. Rev. Control. 36(1), 60\u201372. https:\/\/doi.org\/10.1016\/j.arcontrol.2012.03.005 (2012).","journal-title":"Annu. Rev. Control."},{"issue":"1\u20132","key":"42361_CR2","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1177\/0020294018754714","volume":"51","author":"M Pawlak","year":"2018","unstructured":"Pawlak, M. Active fault tolerant control system for the measurement circuit in a drum boiler feed-water control system. Meas. Control. 51(1\u20132), 4\u201315. https:\/\/doi.org\/10.1177\/0020294018754714 (2018).","journal-title":"Meas. Control."},{"issue":"3","key":"42361_CR3","first-page":"339","volume":"6","author":"Y Wang","year":"2008","unstructured":"Wang, Y., Zhou, D., Qin, S. J. & Wang, H. Active fault-tolerant control for a class of nonlinear systems with sensor faults. Int. J. Control. Autom. Syst. 6(3), 339\u2013350 (2008).","journal-title":"Int. J. Control. Autom. Syst."},{"key":"42361_CR4","first-page":"663","volume-title":"Control Systems Engineering","author":"NS Nise","year":"2012","unstructured":"Nise, N. S. Design via state space. In Control Systems Engineering 6th ed 663\u2013710 (Wiley-Blackwell, 2012).","edition":"6th ed"},{"issue":"2","key":"42361_CR5","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.arcontrol.2008.03.008","volume":"32","author":"Y Zhang","year":"2008","unstructured":"Zhang, Y. & Jiang, J. Bibliographical review on reconfigurable fault-tolerant control systems. Annu. Rev. Control. 32(2), 229\u2013252. https:\/\/doi.org\/10.1016\/j.arcontrol.2008.03.008 (2008).","journal-title":"Annu. Rev. Control."},{"issue":"5","key":"42361_CR6","doi-asserted-by":"publisher","first-page":"359","DOI":"10.3166\/ejc.14.359-386","volume":"14","author":"J Lunze","year":"2008","unstructured":"Lunze, J. & Richter, J. H. Reconfigurable fault-tolerant control: A tutorial introduction. Eur. J. Control. 14(5), 359\u2013386. https:\/\/doi.org\/10.3166\/ejc.14.359-386 (2008).","journal-title":"Eur. J. Control."},{"issue":"9\u201310","key":"42361_CR7","doi-asserted-by":"publisher","first-page":"1179","DOI":"10.1177\/0020294018823031","volume":"52","author":"AA Amin","year":"2019","unstructured":"Amin, A. A. & Mahmood-ul-Hasan, K. Robust active fault-tolerant control for internal combustion gas engine for air\u2013fuel ratio control with statistical regression-based observer model. Meas. Control. 52(9\u201310), 1179\u20131194. https:\/\/doi.org\/10.1177\/0020294018823031 (2019).","journal-title":"Meas. Control."},{"issue":"1","key":"42361_CR8","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/567672","volume":"2014","author":"T Li","year":"2014","unstructured":"Li, T., Zhang, B., Feng, Z. & Zheng, B. Robust control with engineering applications. Math. Probl. Eng. 2014(1), 567672. https:\/\/doi.org\/10.1155\/2014\/567672 (2014).","journal-title":"Math. Probl. Eng."},{"issue":"5\u20136","key":"42361_CR9","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1177\/0020294019842593","volume":"52","author":"AA Amin","year":"2019","unstructured":"Amin, A. A. & Mahmood-ul-Hasan, K. Hybrid fault tolerant control for air\u2013fuel ratio control of internal combustion gasoline engine using Kalman filters with advanced redundancy. Meas. Control. 52(5\u20136), 473\u2013492. https:\/\/doi.org\/10.1177\/0020294019842593 (2019).","journal-title":"Meas. Control."},{"issue":"3","key":"42361_CR10","doi-asserted-by":"publisher","first-page":"1947","DOI":"10.1007\/s42835-021-00965-5","volume":"17","author":"AA Amin","year":"2022","unstructured":"Amin, A. A. & Mahmood-ul-Hasan, K. Unified fault-tolerant control for air-fuel ratio control of internal combustion engines with advanced analytical and hardware redundancies. J. Electr. Eng. Technol. 17(3), 1947\u20131959. https:\/\/doi.org\/10.1007\/s42835-021-00965-5 (2022).","journal-title":"J. Electr. Eng. Technol."},{"key":"42361_CR11","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.measurement.2019.04.083","volume":"143","author":"AA Amin","year":"2019","unstructured":"Amin, A. A. & Hasan, K. M. A review of fault tolerant control systems: Advancements and applications. Measurement 143, 58\u201368. https:\/\/doi.org\/10.1016\/j.measurement.2019.04.083 (2019).","journal-title":"Measurement"},{"key":"42361_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2023.e19557","author":"T Alsuwian","year":"2023","unstructured":"Alsuwian, T., Amin, A. A., Iqbal, M. S. & Maqsood, M. T. A review of anti-surge control systems of compressors and advanced fault-tolerant control techniques for integration perspective. Heliyon https:\/\/doi.org\/10.1016\/j.heliyon.2023.e19557 (2023).","journal-title":"Heliyon"},{"key":"42361_CR13","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1016\/j.apenergy.2016.08.070","volume":"181","author":"VKA Shankar","year":"2016","unstructured":"Shankar, V. K. A., Umashankar, S., Paramasivam, S. & Hanigovszki, N. A comprehensive review on energy efficiency enhancement initiatives in centrifugal pumping system. Appl. Energy 181, 495\u2013513. https:\/\/doi.org\/10.1016\/j.apenergy.2016.08.070 (2016).","journal-title":"Appl. Energy"},{"key":"42361_CR14","unstructured":"Waide, P. & Brunner, C. Energy-Efficiency Policy Opportunities for Electric Motor-Driven Systems (2011)."},{"issue":"3","key":"42361_CR15","doi-asserted-by":"publisher","first-page":"5:1","DOI":"10.1147\/JRD.2009.5429018","volume":"53","author":"SM Bunn","year":"2009","unstructured":"Bunn, S. M. & Reynolds, L. The energy-efficiency benefits of pump-scheduling optimization for potable water supplies. IBM J. Res. Dev. 53(3), 5:1-5:13. https:\/\/doi.org\/10.1147\/JRD.2009.5429018 (2009).","journal-title":"IBM J. Res. Dev."},{"key":"42361_CR16","doi-asserted-by":"publisher","unstructured":"Tamminen, J. et al. Component selection tool to maximize overall energy conversion efficiency in a pumping system. in 2013 15th European Conference on Power Electronics and Applications (EPE) 1\u20139 (IEEE, 2013). https:\/\/doi.org\/10.1109\/EPE.2013.6631839.","DOI":"10.1109\/EPE.2013.6631839"},{"issue":"1","key":"42361_CR17","doi-asserted-by":"publisher","first-page":"100","DOI":"10.3390\/w11010100","volume":"11","author":"Y Zhou","year":"2019","unstructured":"Zhou, Y., Mui, K. & Wong, L. Evaluation of Design Flow Rate of Water Supply Systems with Low Flow Showering Appliances. Water 11(1), 100. https:\/\/doi.org\/10.3390\/w11010100 (2019).","journal-title":"Water"},{"issue":"4","key":"42361_CR18","doi-asserted-by":"publisher","first-page":"2085","DOI":"10.3390\/app12042085","volume":"12","author":"L Li","year":"2022","unstructured":"Li, L., Yuan, Y., Zhang, X., Wu, S. & Zhang, T. Fault-tolerant control scheme for the sensor fault in the acceleration process of variable cycle engine. Appl. Sci. 12(4), 2085. https:\/\/doi.org\/10.3390\/app12042085 (2022).","journal-title":"Appl. Sci."},{"issue":"12","key":"42361_CR19","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0279101","volume":"17","author":"T Alsuwian","year":"2022","unstructured":"Alsuwian, T. et al. Design of active fault-tolerant control system for air-fuel ratio control of internal combustion engine using nonlinear regression-based observer model. PLoS ONE 17(12), e0279101. https:\/\/doi.org\/10.1371\/journal.pone.0279101 (2022).","journal-title":"PLoS ONE"},{"issue":"3","key":"42361_CR20","first-page":"138","volume":"3","author":"K Poomani","year":"2015","unstructured":"Poomani, K. & Rameswari, R. Enhanced PID control strategy: Application to spherical tank system. Int. J. Res. Appl. Sci. Eng. Technol. 3(3), 138\u2013141 (2015).","journal-title":"Int. J. Res. Appl. Sci. Eng. Technol."},{"key":"42361_CR21","doi-asserted-by":"publisher","first-page":"25673","DOI":"10.1109\/ACCESS.2019.2897992","volume":"7","author":"S Razvarz","year":"2019","unstructured":"Razvarz, S., Vargas-Jarillo, C., Jafari, R. & Gegov, A. Flow control of fluid in pipelines using PID controller. IEEE Access 7, 25673\u201325680. https:\/\/doi.org\/10.1109\/ACCESS.2019.2897992 (2019).","journal-title":"IEEE Access"},{"issue":"23","key":"42361_CR22","first-page":"11223","volume":"11","author":"BN Getu","year":"2016","unstructured":"Getu, B. N. Water level controlling system using PID controller. Int. J. Appl. Eng. Res. 11(23), 11223\u201311227 (2016).","journal-title":"Int. J. Appl. Eng. Res."},{"issue":"3","key":"42361_CR23","first-page":"436","volume":"5","author":"MA Fellani","year":"2015","unstructured":"Fellani, M. A. & Gabaj, A. M. PID controller design for two tanks liquid level control system using Matlab. Int. J. Electr. Comput. Eng. 5(3), 436 (2015).","journal-title":"Int. J. Electr. Comput. Eng."},{"key":"42361_CR24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2021\/8856571","volume":"2021","author":"M Amor","year":"2021","unstructured":"Amor, M., Ladhari, T., Said, S. H. & M\u2019Sahli, F. Fault-tolerant control for three-tank system in case of sensor faults. Math. Probl. Eng. 2021, 1\u201313. https:\/\/doi.org\/10.1155\/2021\/8856571 (2021).","journal-title":"Math. Probl. Eng."},{"key":"42361_CR25","doi-asserted-by":"publisher","DOI":"10.36001\/phmconf.2024.v16i1.4137","author":"J Ortega","year":"2024","unstructured":"Ortega, J. et al. Unsupervised fault detection in a controlled conical tank. PHM CONF. https:\/\/doi.org\/10.36001\/phmconf.2024.v16i1.4137 (2024).","journal-title":"PHM CONF."},{"issue":"6","key":"42361_CR26","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.3390\/pr12061218","volume":"12","author":"P Kazemi","year":"2024","unstructured":"Kazemi, P., Masoumian, A. & Martin, P. Fault Detection and Isolation for Time-Varying Processes Using Neural-Based Principal Component Analysis. Processes 12(6), 1218. https:\/\/doi.org\/10.3390\/pr12061218 (2024).","journal-title":"Processes"},{"issue":"2","key":"42361_CR27","doi-asserted-by":"publisher","DOI":"10.1002\/adc2.70011","volume":"7","author":"H Workneh","year":"2025","unstructured":"Workneh, H. & Raptis, I. A comprehensive experimental liquid-level control system for advancing fault diagnosis research innovation: Data, models, and procedures. Adv. Control Appl. 7(2), e70011. https:\/\/doi.org\/10.1002\/adc2.70011 (2025).","journal-title":"Adv. Control Appl."},{"issue":"4","key":"42361_CR28","doi-asserted-by":"publisher","first-page":"132","DOI":"10.3390\/act9040132","volume":"9","author":"HA Trinh","year":"2020","unstructured":"Trinh, H. A., Truong, H. V. A. & Ahn, K. K. Fault estimation and fault-tolerant control for the pump-controlled electrohydraulic system. Actuators 9(4), 132. https:\/\/doi.org\/10.3390\/act9040132 (2020).","journal-title":"Actuators"},{"issue":"5","key":"42361_CR29","doi-asserted-by":"publisher","first-page":"2846","DOI":"10.1080\/03772063.2021.1906767","volume":"69","author":"AA Amin","year":"2023","unstructured":"Amin, A. A. & Mahmood-ul-Hasan, K. Robust passive fault tolerant control for air fuel ratio control of internal combustion gasoline engine for sensor and actuator faults. IETE J. Res. 69(5), 2846\u20132861. https:\/\/doi.org\/10.1080\/03772063.2021.1906767 (2023).","journal-title":"IETE J. Res."},{"key":"42361_CR30","doi-asserted-by":"publisher","DOI":"10.1016\/j.measurement.2025.116728","volume":"246","author":"AA Amin","year":"2025","unstructured":"Amin, A. A., Mubarak, A. & Waseem, S. Application of physics-informed neural networks in fault diagnosis and fault-tolerant control design for electric vehicles: A review. Measurement 246, 116728. https:\/\/doi.org\/10.1016\/j.measurement.2025.116728 (2025).","journal-title":"Measurement"},{"key":"42361_CR31","doi-asserted-by":"publisher","DOI":"10.1016\/j.eswa.2023.121956","volume":"238","author":"AA Amin","year":"2024","unstructured":"Amin, A. A., Iqbal, M. S. & Shahbaz, M. H. Development of intelligent fault-tolerant control systems with machine learning, deep learning, and transfer learning algorithms: A review. Expert Syst. Appl. 238, 121956. https:\/\/doi.org\/10.1016\/j.eswa.2023.121956 (2024).","journal-title":"Expert Syst. Appl."},{"key":"42361_CR32","unstructured":"Well with Jet Pump. https:\/\/www.mathworks.com\/help\/hydro\/ug\/well-with-jet-pump.html"},{"key":"42361_CR33","unstructured":"Fox, R. W., Pritchard, P. J. & McDonald, A. T. Introdu\u00e7\u00e3o \u00c0 Mec\u00e2nica Dos Fluidos (Grupo Gen-LTC, 2000)."},{"key":"42361_CR34","doi-asserted-by":"publisher","DOI":"10.1016\/j.petrol.2021.108582","volume":"203","author":"RM Perissinotto","year":"2021","unstructured":"Perissinotto, R. M. et al. Flow visualization in centrifugal pumps: A review of methods and experimental studies. J. Pet. Sci. Eng. 203, 108582. https:\/\/doi.org\/10.1016\/j.petrol.2021.108582 (2021).","journal-title":"J. Pet. Sci. Eng."},{"key":"42361_CR35","doi-asserted-by":"publisher","unstructured":"Operation of centrifugal pumps. in Centrifugal Pumps 639\u2013688 (Springer Berlin Heidelberg, 2008). https:\/\/doi.org\/10.1007\/978-3-540-73695-0_11.","DOI":"10.1007\/978-3-540-73695-0_11"},{"issue":"5","key":"42361_CR36","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1016\/S0734-743X(01)00153-1","volume":"27","author":"SB Segletes","year":"2002","unstructured":"Segletes, S. B. & Walters, W. P. A note on the application of the extended Bernoulli equation. Int. J. Impact Eng. 27(5), 561\u2013576. https:\/\/doi.org\/10.1016\/S0734-743X(01)00153-1 (2002).","journal-title":"Int. J. Impact Eng."},{"key":"42361_CR37","unstructured":"Montgomery, D. C., Peck, E. A. & Vining, G. G. Simple linear regression. Introduction to Linear Regression Analysis 12\u201366 (2012)."},{"key":"42361_CR38","first-page":"31","volume-title":"Generalized Linear Models with Examples in R","author":"PK Dunn","year":"2018","unstructured":"Dunn, P. K., Smyth, G. K., Dunn, P. K. & Smyth, G. K. Chapter 2: Linear regression models. In Generalized Linear Models with Examples in R 31\u201391 (2018)."},{"issue":"1","key":"42361_CR39","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1197\/j.aem.2003.09.006","volume":"11","author":"KA Marill","year":"2004","unstructured":"Marill, K. A. Advanced statistics: Linear regression, Part II: Multiple linear regression. Acad. Emerg. Med. 11(1), 94\u2013102. https:\/\/doi.org\/10.1197\/j.aem.2003.09.006 (2004).","journal-title":"Acad. Emerg. Med."},{"issue":"8","key":"42361_CR40","doi-asserted-by":"publisher","DOI":"10.3390\/pr12081620","volume":"12","author":"MC Dippenaar","year":"2024","unstructured":"Dippenaar, M. C., Van Schoor, G., Uren, K. R. & Van Niekerk, W. M. K. Fault detection and isolation in transient conditions on a heated two-tank system: A multiway principal component analysis approach. Processes 12(8), 1620. https:\/\/doi.org\/10.3390\/pr12081620 (2024).","journal-title":"Processes"},{"key":"42361_CR41","doi-asserted-by":"publisher","DOI":"10.1016\/j.ifacsc.2022.100197","volume":"21","author":"R Rammal","year":"2022","unstructured":"Rammal, R., Airimitoaie, T.-B., Melchior, P. & Cazaurang, F. Nonlinear three-tank system fault detection and isolation using differential flatness. IFAC J. Syst. Control 21, 100197. https:\/\/doi.org\/10.1016\/j.ifacsc.2022.100197 (2022).","journal-title":"IFAC J. Syst. Control"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42361-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42361-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42361-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T20:28:33Z","timestamp":1781641713000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42361-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,19]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["42361"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-42361-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,19]]},"assertion":[{"value":"4 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The Grammarly Professional Version tool was used to assist language refinement, grammarcorrection, and paraphrasing.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"AI Declaration Statement"}}],"article-number":"14189"}}