{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T23:47:52Z","timestamp":1776383272020,"version":"3.51.2"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T00:00:00Z","timestamp":1772928000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T00:00:00Z","timestamp":1776384000000},"content-version":"vor","delay-in-days":40,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-42451-w","type":"journal-article","created":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T17:23:12Z","timestamp":1772990592000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Ocular biometry agreement among ZW-30, IOLMaster 700, and sirius in cataract patients"],"prefix":"10.1038","volume":"16","author":[{"given":"Junjie","family":"Yang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nijuan","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuying","family":"Xiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rui","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xuan","family":"Yu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ling","family":"Jin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yukan","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,3,8]]},"reference":[{"key":"42451_CR1","doi-asserted-by":"publisher","unstructured":"Huang, J. et al. Reliability of a new swept-source optical coherence tomography biometer in healthy children, adults, and cataract patients. J. Ophthalmol. 2020, 8946364.  https:\/\/doi.org\/10.1155\/2020\/8946364 (2020).","DOI":"10.1155\/2020\/8946364"},{"key":"42451_CR2","doi-asserted-by":"publisher","first-page":"1302","DOI":"10.1097\/j.jcrs.0000000000000633","volume":"47","author":"AD Fi\u015fu\u015f","year":"2021","unstructured":"Fi\u015fu\u015f, A. D. et al. Repeatability of 2 swept-source OCT biometers and 1 optical low-coherence reflectometry biometer. J. Cataract Refract. Surg. 47, 1302\u20131307. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000633 (2021).","journal-title":"J. Cataract Refract. Surg."},{"key":"42451_CR3","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1007\/s00417-018-3909-9","volume":"256","author":"JA Calvo-Sanz","year":"2018","unstructured":"Calvo-Sanz, J. A., Portero-Benito, A. & Arias-Puente, A. Efficiency and measurements agreement between swept-source OCT and low -coherence interferometry biometry systems. Graefes Arch. Clin. Exp. Ophthalmol. 256, 559\u2013566. https:\/\/doi.org\/10.1007\/s00417-018-3909-9 (2018).","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"42451_CR4","doi-asserted-by":"publisher","first-page":"1191","DOI":"10.2147\/OPTH.S464538","volume":"18","author":"M Pathak","year":"2024","unstructured":"Pathak, M., Sahu, V., Kumar, A., Kaur, K. & Gurnani, B. Current concepts and recent updates of optical biometry- a comprehensive review. Clin. Ophthalmol. 18, 1191\u20131206. https:\/\/doi.org\/10.2147\/OPTH.S464538 (2024).","journal-title":"Clin. Ophthalmol."},{"key":"42451_CR5","doi-asserted-by":"publisher","first-page":"1222","DOI":"10.1097\/j.jcrs.0000000000000237","volume":"46","author":"MA Henriquez","year":"2020","unstructured":"Henriquez, M. A. et al. Effectiveness and agreement of 3 optical biometers in measuring axial length in the eyes of patients with mature cataracts. J. Cataract Refract. Surg. 46, 1222\u20131228. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000237 (2020).","journal-title":"J. Cataract Refract. Surg."},{"key":"42451_CR6","doi-asserted-by":"publisher","first-page":"9236006","DOI":"10.1155\/2022\/9236006","volume":"2022","author":"X Li","year":"2022","unstructured":"Li, X., Cao, X. & Bao, Y. Comparison of total corneal astigmatism between IOLMaster and pentacam. Biomed. Res. Int. 2022, 9236006. https:\/\/doi.org\/10.1155\/2022\/9236006 (2022).","journal-title":"Biomed. Res. Int."},{"key":"42451_CR7","doi-asserted-by":"publisher","unstructured":"Jin, Y. et al. Sirius Scheimpflug-Placido versus ultrasound pachymetry for central corneal thickness: meta-analysis. Eye Vis. (Lond)  8, 5. https:\/\/doi.org\/10.1186\/s40662-021-00227-5 (2021).","DOI":"10.1186\/s40662-021-00227-5"},{"key":"42451_CR8","doi-asserted-by":"publisher","first-page":"1392","DOI":"10.1097\/ICO.0000000000002964","volume":"41","author":"S Namkung","year":"2022","unstructured":"Namkung, S. et al. Repeatability and agreement of horizontal corneal diameter measurements between scanning-slit topography, dual rotating scheimpflug camera with placido disc tomography, placido disc topography, and optical cohe rence tomography. Cornea 41, 1392\u20131397. https:\/\/doi.org\/10.1097\/ICO.0000000000002964 (2022).","journal-title":"Cornea"},{"key":"42451_CR9","doi-asserted-by":"publisher","first-page":"2016","DOI":"10.1038\/s41433-020-01213-2","volume":"35","author":"Y Busool Abu-Eta","year":"2021","unstructured":"Busool Abu-Eta, Y. et al. Outcomes of photorefractive keratectomy in patients with posterior cor neal steepening. Eye (Lond). 35, 2016\u20132023. https:\/\/doi.org\/10.1038\/s41433-020-01213-2 (2021).","journal-title":"Eye (Lond)"},{"key":"42451_CR10","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1007\/s00417-024-06661-0","volume":"263","author":"MV de Rojas Silva","year":"2025","unstructured":"de Rojas Silva, M. V., Tob\u00edo Ruibal, A., Suanzes Hern\u00e1ndez, J. & Darriba Folgar, H. Assessing the predictability of five intraocular lens calculation methods in eyes with prior myopic keratorefractive lenticule extraction. Graefes Arch. Clin. Exp. Ophthalmol. 263, 873\u2013881. https:\/\/doi.org\/10.1007\/s00417-024-06661-0 (2025).","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"42451_CR11","doi-asserted-by":"publisher","first-page":"e142","DOI":"10.1016\/j.ophtha.2020.11.016","volume":"128","author":"S Goto","year":"2021","unstructured":"Goto, S. & Maeda, N. Corneal topography for intraocular lens selection in refractive cataract surgery. Ophthalmology 128, e142\u2013e. https:\/\/doi.org\/10.1016\/j.ophtha.2020.11.016 (2021).","journal-title":"Ophthalmology"},{"key":"42451_CR12","doi-asserted-by":"publisher","first-page":"104302","DOI":"10.1016\/j.pdpdt.2024.104302","volume":"49","author":"H Song","year":"2024","unstructured":"Song, H., Liu, C., Yang, W., Yang, C. & Cheng, X. Comparison of central corneal thickness measured in myopic eyes by Pentacam, Sirius and IOLMaster 700. Photodiagnosis Photodyn. Ther. 49, 104302. https:\/\/doi.org\/10.1016\/j.pdpdt.2024.104302 (2024).","journal-title":"Photodiagnosis Photodyn. Ther."},{"key":"42451_CR13","doi-asserted-by":"publisher","first-page":"104471","DOI":"10.1016\/j.pdpdt.2025.104471","volume":"51","author":"H Song","year":"2025","unstructured":"Song, H., Yang, W., Yang, C. & Sun, Q. Comparison of anterior chamber depth measured by three different anter ior segment analysis systems. Photodiagnosis Photodyn. Ther. 51, 104471. https:\/\/doi.org\/10.1016\/j.pdpdt.2025.104471 (2025).","journal-title":"Photodiagnosis Photodyn. Ther."},{"key":"42451_CR14","doi-asserted-by":"publisher","first-page":"e0290417","DOI":"10.1371\/journal.pone.0290417","volume":"18","author":"A Saad","year":"2023","unstructured":"Saad, A., Steinberg, J. & Frings, A. Repeatability of pupil diameter measurements using three different topography devices. PLoS One. 18, e0290417. https:\/\/doi.org\/10.1371\/journal.pone.0290417 (2023).","journal-title":"PLoS One"},{"key":"42451_CR15","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1007\/s10792-024-03394-1","volume":"45","author":"C Yu","year":"2025","unstructured":"Yu, C. et al. Analysis of differences between keratometric astigmatism and total corneal astigmatism measured by IOLMaster 700. Int. Ophthalmol. 45, 66. https:\/\/doi.org\/10.1007\/s10792-024-03394-1 (2025).","journal-title":"Int. Ophthalmol."},{"key":"42451_CR16","doi-asserted-by":"publisher","first-page":"381","DOI":"10.3928\/1081597X-20230426-01","volume":"39","author":"JX Kane","year":"2023","unstructured":"Kane, J. X., LaHood, B. R. & Goggin, M. Analysis of posterior corneal surgically induced astigmatism following cataract surgery with a 1.8-mm temporal clear corneal incision. J. Refract. Surg. 39, 381\u2013386. https:\/\/doi.org\/10.3928\/1081597X-20230426-01 (2023).","journal-title":"J. Refract. Surg."},{"key":"42451_CR17","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/s40662-024-00377-2","volume":"11","author":"J Yu","year":"2024","unstructured":"Yu, J. et al. Evaluation of a new dynamic real-time visualization 25\u00a0kHz swept-source optical coherence tomography based biometer. Eye Vis. (Lond.) 11, 9. https:\/\/doi.org\/10.1186\/s40662-024-00377-2 (2024).","journal-title":"Eye Vis. (Lond.)"},{"key":"42451_CR18","doi-asserted-by":"publisher","first-page":"e413","DOI":"10.3928\/1081597X-20250317-03","volume":"41","author":"CS Lei","year":"2025","unstructured":"Lei, C. S. et al. Comparison of anterior segment measurements with a new swept-source op tical coherence tomography biometer and a Scheimpflug-Placido Topographer. J. Refract. Surg. 41, e413\u2013e420. https:\/\/doi.org\/10.3928\/1081597X-20250317-03 (2025).","journal-title":"J. Refract. Surg."},{"key":"42451_CR19","doi-asserted-by":"publisher","first-page":"1437","DOI":"10.18240\/ijo.2024.08.08","volume":"17","author":"S Ma","year":"2024","unstructured":"Ma, S. et al. Comparison of ocular biometric parameters between two swept-source optical coherence tomography devices and Scheimpflug tomography in patients with cataract. Int. J. Ophthalmol. 17, 1437\u20131446. https:\/\/doi.org\/10.18240\/ijo.2024.08.08 (2024).","journal-title":"Int. J. Ophthalmol."},{"key":"42451_CR20","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.ajo.2025.03.026","volume":"275","author":"X Fang","year":"2025","unstructured":"Fang, X. et al. Comparison of corneal power assessment methods for true corneal power after myopic small-incision lenticule extractio. Am. J. Ophthalmol. 275, 156\u2013163. https:\/\/doi.org\/10.1016\/j.ajo.2025.03.026 (2025).","journal-title":"Am. J. Ophthalmol."},{"key":"42451_CR21","doi-asserted-by":"publisher","first-page":"928027","DOI":"10.3389\/fmed.2022.928027","volume":"9","author":"Z Wang","year":"2022","unstructured":"Wang, Z. et al. Comparing standard keratometry and total keratometry before and after myopic corneal refractive surgery with a swept-source OCT biometer. Front. Med. (Lausanne). 9, 928027. https:\/\/doi.org\/10.3389\/fmed.2022.928027 (2022).","journal-title":"Front. Med. (Lausanne)"},{"key":"42451_CR22","doi-asserted-by":"publisher","first-page":"6921","DOI":"10.3390\/jcm11236921","volume":"11","author":"M Muzyka-Wo\u017aniak","year":"2022","unstructured":"Muzyka-Wo\u017aniak, M., Oleszko, A. & Grzybowski, A. Measurements of anterior and posterior corneal curvatures with OCT and Scheimpflug biometers in patients with low total corneal astigmatism. J. Clin. Med. 11, 6921. https:\/\/doi.org\/10.3390\/jcm11236921 (2022).","journal-title":"J. Clin. Med."},{"key":"42451_CR23","doi-asserted-by":"publisher","first-page":"1490674","DOI":"10.3389\/fmed.2024.1490674","volume":"11","author":"J Ning","year":"2024","unstructured":"Ning, J. & Zhang, L. Comparison of Scheimpflug tomography, Placido disc, and combined Placido Scheimpflug in the measurement of pupil offset in myopic population. Front. Med. (Lausanne). 11, 1490674. https:\/\/doi.org\/10.3389\/fmed.2024.1490674 (2024).","journal-title":"Front. Med. (Lausanne)"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42451-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42451-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42451-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T22:58:00Z","timestamp":1776380280000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42451-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,8]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["42451"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-42451-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,8]]},"assertion":[{"value":"17 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This study was approved by the Human Ethics Committee of Wuhan Union Hospital, Tongji Medical College, Huazhong University of Science and Technology. The patients\/participants provided their written informed consent to participate in this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}],"article-number":"12618"}}