{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T21:31:17Z","timestamp":1792791077351,"version":"4.5.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,3]],"date-time":"2026-03-03T00:00:00Z","timestamp":1772496000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"vor","delay-in-days":37,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100004829","name":"Science and Technology Department of Sichuan Province","doi-asserted-by":"publisher","award":["2024YFFK0046"],"award-info":[{"award-number":["2024YFFK0046"]}],"id":[{"id":"10.13039\/501100004829","id-type":"DOI","asserted-by":"publisher"}]},{"name":"1\u22193\u22195 Project for Disciplines of Excellence-Clinical Research Incubation Project, West China Hospital of Sichuan University","award":["2023HXFH002"],"award-info":[{"award-number":["2023HXFH002"]}],"id":[{"id":"https:\/\/ror.org\/007mrxy13","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-42503-1","type":"journal-article","created":{"date-parts":[[2026,3,3]],"date-time":"2026-03-03T08:59:52Z","timestamp":1772528392000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Impact of contact parameters on lesion dimensions during circular Pulsed-Field ablation in ex vivo and in vivo models"],"prefix":"10.1038","volume":"16","author":[{"given":"Xianjin","family":"Hu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenjie","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bangjiaxin","family":"Ren","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fanghui","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aobo","family":"Gong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xianzhao","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luyang","family":"Xie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zexi","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rui","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,3]]},"reference":[{"key":"42503_CR1","doi-asserted-by":"publisher","first-page":"2008","DOI":"10.1016\/j.jacep.2023.03.014","volume":"9","author":"C Tabaja","year":"2023","unstructured":"Tabaja, C. et al. Catheter-Based Electroporation: A Novel Technique for Catheter Ablation of Cardiac Arrhythmias. JACC Clin. Electrophysiol. 9, 2008\u20132023. https:\/\/doi.org\/10.1016\/j.jacep.2023.03.014 (2023).","journal-title":"JACC Clin. Electrophysiol."},{"key":"42503_CR2","doi-asserted-by":"publisher","first-page":"4383","DOI":"10.1093\/eurheartj\/ehae618","volume":"45","author":"A Natale","year":"2024","unstructured":"Natale, A. et al. Catheter ablation for atrial fibrillation: indications and future perspective. Eur. Heart J. 45, 4383\u20134398. https:\/\/doi.org\/10.1093\/eurheartj\/ehae618 (2024).","journal-title":"Eur. Heart J."},{"key":"42503_CR3","doi-asserted-by":"publisher","first-page":"1660","DOI":"10.1056\/NEJMoa2307291","volume":"389","author":"VY Reddy","year":"2023","unstructured":"Reddy, V. Y. et al. Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation. N Engl. J. Med. 389, 1660\u20131671. https:\/\/doi.org\/10.1056\/NEJMoa2307291 (2023).","journal-title":"N Engl. J. Med."},{"key":"42503_CR4","doi-asserted-by":"publisher","first-page":"1422","DOI":"10.1161\/circulationaha.123.063988","volume":"147","author":"A Verma","year":"2023","unstructured":"Verma, A. et al. Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial. Circulation 147, 1422\u20131432. https:\/\/doi.org\/10.1161\/circulationaha.123.063988 (2023).","journal-title":"Circulation"},{"key":"42503_CR5","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1016\/j.tcm.2016.12.002","volume":"27","author":"B Reissmann","year":"2017","unstructured":"Reissmann, B., Metzner, A. & Kuck, K. H. Cryoballoon ablation versus radiofrequency ablation for atrial fibrillation. Trends Cardiovasc. Med. 27, 271\u2013277. https:\/\/doi.org\/10.1016\/j.tcm.2016.12.002 (2017).","journal-title":"Trends Cardiovasc. Med."},{"key":"42503_CR6","doi-asserted-by":"publisher","first-page":"1242","DOI":"10.1016\/j.hrthm.2024.03.1763","volume":"21","author":"TF Deering","year":"2024","unstructured":"Deering, T. F. et al. Pulsed field ablation: A promise with future broad-based applicability or a pause needing further analysis-Is catheter ablation at a crossroads? A critical appraisal of the new challenger-pulsed field ablation. Heart rhythm. 21, 1242\u20131244. https:\/\/doi.org\/10.1016\/j.hrthm.2024.03.1763 (2024).","journal-title":"Heart rhythm"},{"key":"42503_CR7","doi-asserted-by":"publisher","first-page":"1497","DOI":"10.1056\/NEJMoa2502280","volume":"392","author":"T Reichlin","year":"2025","unstructured":"Reichlin, T. et al. Pulsed Field or Cryoballoon Ablation for Paroxysmal Atrial Fibrillation. N Engl. J. Med. 392, 1497\u20131507. https:\/\/doi.org\/10.1056\/NEJMoa2502280 (2025).","journal-title":"N Engl. J. Med."},{"key":"42503_CR8","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.jacep.2024.09.025","volume":"11","author":"R Scacciavillani","year":"2025","unstructured":"Scacciavillani, R. et al. Safety and Feasibility of Pulsed-Field Ablation in Patients With Mechanical Prosthetic Valves. JACC Clin. Electrophysiol. 11, 98\u2013106. https:\/\/doi.org\/10.1016\/j.jacep.2024.09.025 (2025).","journal-title":"JACC Clin. Electrophysiol."},{"key":"42503_CR9","doi-asserted-by":"publisher","unstructured":"Reddy, V. Y. et al. Pulsed Field Ablation of Persistent Atrial Fibrillation With Continuous ECG Monitoring Follow-Up: ADVANTAGE AF-Phase 2. Circulation (2025). https:\/\/doi.org\/10.1161\/circulationaha.125.074485","DOI":"10.1161\/circulationaha.125.074485"},{"key":"42503_CR10","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.jacep.2022.10.037","volume":"9","author":"WH Sauer","year":"2023","unstructured":"Sauer, W. H. & Kreidieh, O. Precision Medicine and Ablation of Ventricular Arrhythmias: The Difficulty of Estimating Lesion Size and Durability. JACC Clin. Electrophysiol. 9, 341\u2013344. https:\/\/doi.org\/10.1016\/j.jacep.2022.10.037 (2023).","journal-title":"JACC Clin. Electrophysiol."},{"key":"42503_CR11","doi-asserted-by":"publisher","first-page":"874","DOI":"10.1093\/europace\/euab279","volume":"24","author":"MJ Mulder","year":"2022","unstructured":"Mulder, M. J., Kemme, M. J. B. & Allaart, C. P. Radiofrequency ablation to achieve durable pulmonary vein isolation. Europace: Eur. pacing Arrhythm. cardiac Electrophysiol. : J. working groups cardiac pacing Arrhythm. cardiac Cell. Electrophysiol. Eur. Soc. Cardiol. 24, 874\u2013886. https:\/\/doi.org\/10.1093\/europace\/euab279 (2022).","journal-title":"Europace: Eur. pacing Arrhythm. cardiac Electrophysiol. : J. working groups cardiac pacing Arrhythm. cardiac Cell. Electrophysiol. Eur. Soc. Cardiol."},{"key":"42503_CR12","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1016\/j.jacep.2020.09.011","volume":"7","author":"PC Qian","year":"2021","unstructured":"Qian, P. C. et al. Optimizing Impedance Change Measurement During Radiofrequency Ablation Enables More Accurate Characterization of Lesion Formation. JACC Clin. Electrophysiol. 7, 471\u2013481. https:\/\/doi.org\/10.1016\/j.jacep.2020.09.011 (2021).","journal-title":"JACC Clin. Electrophysiol."},{"key":"42503_CR13","doi-asserted-by":"publisher","first-page":"1738","DOI":"10.1016\/j.hrthm.2024.03.042","volume":"21","author":"N Steiger","year":"2024","unstructured":"Steiger, N. et al. Relative contribution of contact force to lesion depth using high-power short-duration radiofrequency applications. Heart rhythm. 21, 1738\u20131740. https:\/\/doi.org\/10.1016\/j.hrthm.2024.03.042 (2024).","journal-title":"Heart rhythm"},{"key":"42503_CR14","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1016\/j.hrthm.2016.11.013","volume":"14","author":"G Rozen","year":"2017","unstructured":"Rozen, G. et al. Prediction of radiofrequency ablation lesion formation using a novel temperature sensing technology incorporated in a force sensing catheter. Heart rhythm. 14, 248\u2013254. https:\/\/doi.org\/10.1016\/j.hrthm.2016.11.013 (2017).","journal-title":"Heart rhythm"},{"key":"42503_CR15","doi-asserted-by":"publisher","first-page":"e012814","DOI":"10.1161\/circep.124.012814","volume":"17","author":"H Nakagawa","year":"2024","unstructured":"Nakagawa, H. et al. Evaluation of Ablation Parameters to Predict Irreversible Lesion Size During Pulsed Field Ablation. Circ. Arrhythm. Electrophys. 17, e012814. https:\/\/doi.org\/10.1161\/circep.124.012814 (2024).","journal-title":"Circ. Arrhythm. Electrophys."},{"key":"42503_CR16","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1016\/j.hrthm.2024.09.061","volume":"22","author":"Y Okumura","year":"2025","unstructured":"Okumura, Y. et al. In vivo assessment of catheter-tissue contact using tissue proximity indication and its impact on cardiac lesion formation in pulsed field ablation. Heart rhythm. 22, 952\u2013960. https:\/\/doi.org\/10.1016\/j.hrthm.2024.09.061 (2025).","journal-title":"Heart rhythm"},{"key":"42503_CR17","doi-asserted-by":"publisher","first-page":"1789","DOI":"10.1016\/j.hrthm.2012.07.016","volume":"9","author":"VY Reddy","year":"2012","unstructured":"Reddy, V. Y. et al. The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart rhythm. 9, 1789\u20131795. https:\/\/doi.org\/10.1016\/j.hrthm.2012.07.016 (2012).","journal-title":"Heart rhythm"},{"key":"42503_CR18","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1016\/j.jacep.2018.03.014","volume":"4","author":"N Ariyarathna","year":"2018","unstructured":"Ariyarathna, N., Kumar, S., Thomas, S. P., Stevenson, W. G. & Michaud, G. F. Role of Contact Force Sensing in Catheter Ablation of Cardiac Arrhythmias: Evolution or History Repeating Itself? JACC Clin. Electrophysiol. 4, 707\u2013723. https:\/\/doi.org\/10.1016\/j.jacep.2018.03.014 (2018).","journal-title":"JACC Clin. Electrophysiol."},{"key":"42503_CR19","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2025.01.022","author":"Y Saito","year":"2025","unstructured":"Saito, Y. et al. Clinical importance of tissue proximity indication during pulsed field ablation for atrial fibrillation: insights from initial experience. Heart rhythm. https:\/\/doi.org\/10.1016\/j.hrthm.2025.01.022 (2025).","journal-title":"Heart rhythm"},{"key":"42503_CR20","doi-asserted-by":"publisher","first-page":"1412","DOI":"10.1016\/j.hroo.2025.05.026","volume":"2 6","author":"MHA Groen","year":"2025","unstructured":"Groen, M. H. A., Fish, J. M., Loh, P. & van Es, R. Impact of electrode\u2013tissue proximity on formation of pulsed field ablation lesions: Using multi-electrode impedance measurements. Heart rhythm O. 2 6, 1412\u20131418. https:\/\/doi.org\/10.1016\/j.hroo.2025.05.026 (2025).","journal-title":"Heart rhythm O"},{"key":"42503_CR21","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euae220","author":"L Di Biase","year":"2024","unstructured":"Di Biase, L. et al. Application Repetition and Electrode-Tissue-Contact Results in Deeper Lesions Using a Pulsed-Field Ablation Circular Variable Loop Catheter. Europace: Eur. pacing Arrhythm. cardiac Electrophysiol. : J. working groups cardiac pacing Arrhythm. cardiac Cell. Electrophysiol. Eur. Soc. Cardiol. https:\/\/doi.org\/10.1093\/europace\/euae220 (2024).","journal-title":"Europace: Eur. pacing Arrhythm. cardiac Electrophysiol. : J. working groups cardiac pacing Arrhythm. cardiac Cell. Electrophysiol. Eur. Soc. Cardiol."},{"key":"42503_CR22","doi-asserted-by":"publisher","first-page":"e012723","DOI":"10.1161\/circep.123.012723","volume":"17","author":"A Younis","year":"2024","unstructured":"Younis, A. et al. Impact of Contact Force on Pulsed Field Ablation Outcomes Using Focal Point Catheter. Circ. Arrhythm. Electrophys. 17, e012723. https:\/\/doi.org\/10.1161\/circep.123.012723 (2024).","journal-title":"Circ. Arrhythm. Electrophys."},{"key":"42503_CR23","doi-asserted-by":"publisher","first-page":"e012026","DOI":"10.1161\/circep.123.012026","volume":"17","author":"H Nakagawa","year":"2024","unstructured":"Nakagawa, H. et al. Effects of Contact Force on Lesion Size During Pulsed Field Catheter Ablation: Histochemical Characterization of Ventricular Lesion Boundaries. Circ. Arrhythm. Electrophys. 17, e012026. https:\/\/doi.org\/10.1161\/circep.123.012026 (2024).","journal-title":"Circ. Arrhythm. Electrophys."},{"key":"42503_CR24","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1111\/jce.15813","volume":"34","author":"L Mattison","year":"2023","unstructured":"Mattison, L. et al. Effect of contact force on pulsed field ablation lesions in porcine cardiac tissue. J. Cardiovasc. Electrophys. 34, 693\u2013699. https:\/\/doi.org\/10.1111\/jce.15813 (2023).","journal-title":"J. Cardiovasc. Electrophys."},{"key":"42503_CR25","doi-asserted-by":"publisher","unstructured":"Gasperetti, A. et al. Determinants of acute irreversible electroporation lesion characteristics after pulsed field ablation: the role of voltage, contact, and adipose interference. Europace: Eur. pacing Arrhythm. cardiac Electrophysiol. : J. working groups cardiac pacing Arrhythm. cardiac Cell. Electrophysiol. Eur. Soc. Cardiol. 25 https:\/\/doi.org\/10.1093\/europace\/euad257 (2023).","DOI":"10.1093\/europace\/euad257"},{"key":"42503_CR26","doi-asserted-by":"publisher","first-page":"642","DOI":"10.1111\/jce.16581","volume":"36","author":"T Koya","year":"2025","unstructured":"Koya, T. et al. Effects of In Vivo Contact Force on Pulsed-Field Ablation Efficacy in Porcine Ventricles. J. Cardiovasc. Electrophys. 36, 642\u2013649. https:\/\/doi.org\/10.1111\/jce.16581 (2025).","journal-title":"J. Cardiovasc. Electrophys."},{"key":"42503_CR27","doi-asserted-by":"publisher","first-page":"e012717","DOI":"10.1161\/circep.123.012717","volume":"17","author":"L Di Biase","year":"2024","unstructured":"Di Biase, L. et al. Pulsed Field Ablation Index-Guided Ablation for Lesion Formation: Impact of Contact Force and Number of Applications in the Ventricular Model. Circ. Arrhythm. Electrophys. 17, e012717. https:\/\/doi.org\/10.1161\/circep.123.012717 (2024).","journal-title":"Circ. Arrhythm. Electrophys."},{"key":"42503_CR28","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1111\/jce.16515","volume":"36","author":"DA Gomes","year":"2024","unstructured":"Gomes, D. A. et al. Left Atrial Wall Thickness Measured by a Machine Learning Method Predicts AF Recurrence After Pulmonary Vein Isolation. J. Cardiovasc. Electrophys. 36, 323\u2013330. https:\/\/doi.org\/10.1111\/jce.16515 (2024).","journal-title":"J. Cardiovasc. Electrophys."},{"key":"42503_CR29","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1093\/europace\/euab216","volume":"24","author":"C Teres","year":"2022","unstructured":"Teres, C. et al. Personalized paroxysmal atrial fibrillation ablation by tailoring ablation index to the left atrial wall thickness: the \u2018Ablate by-LAW\u2019 single-centre study\u2014a pilot study. EP Europace. 24, 390\u2013399. https:\/\/doi.org\/10.1093\/europace\/euab216 (2022).","journal-title":"EP Europace"},{"key":"42503_CR30","doi-asserted-by":"publisher","unstructured":"Falasconi, G. et al. Personalized pulmonary vein antrum isolation guided by left atrial wall thickness for persistent atrial fibrillation. Europace: European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 25 (2023). https:\/\/doi.org\/10.1093\/europace\/euad118","DOI":"10.1093\/europace\/euad118"},{"key":"42503_CR31","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1161\/circep.123.012344","volume":"16","author":"L Di Biase","year":"2023","unstructured":"Di Biase, L. et al. Point-by-Point Pulsed Field Ablation Using a Multimodality Generator and a Contact Force-Sensing Ablation Catheter: Comparison With Radiofrequency Ablation in a Remapped Chronic Swine Heart. Circ. Arrhythm. Electrophys. 16, 663\u2013671. https:\/\/doi.org\/10.1161\/circep.123.012344 (2023).","journal-title":"Circ. Arrhythm. Electrophys."},{"key":"42503_CR32","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2025.02.017","author":"T Kueffer","year":"2025","unstructured":"Kueffer, T. et al. Dose-dependent ventricular lesion formation using a novel large-area pulsed field ablation catheter: A preclinical feasibility study. Heart rhythm. https:\/\/doi.org\/10.1016\/j.hrthm.2025.02.017 (2025).","journal-title":"Heart rhythm"},{"key":"42503_CR33","doi-asserted-by":"publisher","unstructured":"Verma, A., Maffre, J., Sharma, T. & Farshchi-Heydari, S. Effect of Sequential, Colocalized Radiofrequency and Pulsed Field Ablation on Cardiac Lesion Size and Histology. Circulation: Arrhythmia Electrophysiol. 18 https:\/\/doi.org\/10.1161\/circep.124.013143 (2025).","DOI":"10.1161\/circep.124.013143"},{"key":"42503_CR34","doi-asserted-by":"publisher","first-page":"1478","DOI":"10.1016\/j.jacep.2025.03.014","volume":"11","author":"MTK Tam","year":"2025","unstructured":"Tam, M. T. K. et al. Effect of Pulsed-Field Ablation on Human Coronary Arteries: A Longitudinal Study With Intracoronary Imaging. JACC Clin. Electrophysiol. 11, 1478\u20131488. https:\/\/doi.org\/10.1016\/j.jacep.2025.03.014 (2025).","journal-title":"JACC Clin. Electrophysiol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42503-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42503-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42503-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T10:22:08Z","timestamp":1775730128000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-42503-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,3]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["42503"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-42503-1","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,3]]},"assertion":[{"value":"15 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Xianzhao Zhu and Luyang Xie are employees of Sichuan Jinjiang Electronic Medical Device Technology Co., Ltd. Their roles in the study were limited to: (1) Technical assistance in configuring and calibrating the PFA equipment during experiments. (2) Operational support for the 3D Electroanatomic Mapping System. (3) Data collection and preliminary organization of raw experimental outputs. It is important to note that these two authors were not involved in the design of the experimental protocol, data analysis\/interpretation, manuscript preparation, or any decision-making processes related to the study outcomes. Their participation was strictly confined to technical execution under the supervision of the independent research team. All remaining authors have declared no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Xianzhao Zhu and Luyang Xie are employees of Sichuan Jinjiang Electronic Medical Device Technology Co., Ltd. All remaining authors have declared no conflicts of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"11811"}}