{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T00:34:56Z","timestamp":1777250096106,"version":"3.51.4"},"reference-count":44,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T00:00:00Z","timestamp":1773446400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T00:00:00Z","timestamp":1777248000000},"content-version":"vor","delay-in-days":44,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Agricultural and Social Development Science and Technology Project of Yinzhou District","award":["2020AS0034"],"award-info":[{"award-number":["2020AS0034"]}]},{"name":"Ningbo No.6 Hospital Science and Technology Program","award":["2023002"],"award-info":[{"award-number":["2023002"]}]},{"name":"Ningbo Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation","award":["2024L004"],"award-info":[{"award-number":["2024L004"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-43182-8","type":"journal-article","created":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T09:24:13Z","timestamp":1773480253000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Biomechanical evaluation of X-ray permeable CF\/PEEK composite versus conventional titanium alloy for tibial external fixation plates: a finite element analysis"],"prefix":"10.1038","volume":"16","author":[{"given":"Shuaiyi","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zuodong","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lin","family":"An","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ning","family":"Ni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jingwei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qing","family":"Yan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianming","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,3,14]]},"reference":[{"key":"43182_CR1","doi-asserted-by":"crossref","unstructured":"Court-Brown, C. M. & Caesar, B. Epidemiology of adult fractures: A review. Injury [Internet]. 2006 Aug 1 [cited 2025 Jul 31];37(8), 691\u20137 (2025). Available from: https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0020138306003238?via%3Dihub","DOI":"10.1016\/j.injury.2006.04.130"},{"issue":"1","key":"43182_CR2","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-025-08586-z","volume":"26","author":"B Cong","year":"2025","unstructured":"Cong, B. & Zhang, H. Acute compartment syndrome in tibial fractures: A meta-analysis. BMC Musculoskelet Disord. 26(1), 329. https:\/\/doi.org\/10.1186\/s12891-025-08586-z (2025).","journal-title":"BMC Musculoskelet Disord."},{"issue":"6","key":"43182_CR3","doi-asserted-by":"publisher","first-page":"854","DOI":"10.4055\/cios24058","volume":"16","author":"YC Yoon","year":"2024","unstructured":"Yoon, Y. C. et al. Staged Fixation with Respect to Soft Tissue in Tibial Plateau Fractures with Acute Compartment Syndrome: Correlation Analysis of Complications. Clin. Orthop. Surg. 16(6), 854\u2013862 (2024).","journal-title":"Clin Orthop Surg."},{"key":"43182_CR4","doi-asserted-by":"crossref","unstructured":"Gaudinez, R. F., Mallik, A. R. & Szporn, M. Hybrid External Fixation of Comminuted Tibial Plateau Fractures. Clin. Orthop. Relat. Res. [Internet]. 328, 203\u2013210. (1996). Available from: https:\/\/journals.lww.com\/clinorthop\/fulltext\/1996\/07000\/hybrid_external_fixation_of_comminuted_tibial.32.aspx","DOI":"10.1097\/00003086-199607000-00032"},{"issue":"5","key":"43182_CR5","doi-asserted-by":"publisher","first-page":"444","DOI":"10.5152\/j.aott.2021.20350","volume":"55","author":"SK Tripathy","year":"2021","unstructured":"Tripathy, S. K. et al. External fixation versus open reduction and internal fixation in the treatment of Complex Tibial Plateau Fractures: A systematic review and meta-analysis. Acta. Orthop. Traumatol.Turc. 55(5), 444\u2013456 (2021).","journal-title":"Acta Orthop Traumatol Turc."},{"issue":"11","key":"43182_CR6","doi-asserted-by":"publisher","first-page":"3201","DOI":"10.1007\/s00402-021-04104-7","volume":"142","author":"SJ Janssen","year":"2022","unstructured":"Janssen, S. J. & Kloen, P. Supercutaneous locking compression plate in the treatment of infected non-union and open fracture of the leg. Arch. Orthop. Trauma. Surg. 142(11), 3201\u20133211. https:\/\/doi.org\/10.1007\/s00402-021-04104-7 (2022).","journal-title":"Arch Orthop Trauma Surg."},{"issue":"2","key":"43182_CR7","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1007\/s10439-023-03363-2","volume":"52","author":"FA Bologna","year":"2024","unstructured":"Bologna, F. A., Audenino, A. L. & Terzini, M. Bone plates runout prediction through tensile strength and geometric properties for regulatory mechanical testing. Ann. Biomed. Eng. 52(2), 239\u2013249. https:\/\/doi.org\/10.1007\/s10439-023-03363-2 (2024).","journal-title":"Ann Biomed Eng."},{"key":"43182_CR8","doi-asserted-by":"crossref","unstructured":"Egol, K. A., Kubiak, E. N., Fulkerson, E., Kummer, F. J. & Koval, K. J. Biomechanics of Locked Plates and Screws. J. Orthop. Trauma. [Internet]. 18(8), (2004). Available from: https:\/\/journals.lww.com\/jorthotrauma\/fulltext\/2004\/09000\/biomechanics_of_locked_plates_and_screws.3.aspx","DOI":"10.1097\/00005131-200409000-00003"},{"issue":"9","key":"43182_CR9","doi-asserted-by":"publisher","first-page":"1253","DOI":"10.1177\/09544119221108540","volume":"236","author":"S Zhang","year":"2022","unstructured":"Zhang, S. et al. Experimental testing of fracture fixation plates: A review. Proc. Inst. Mech. Eng. H. 236(9), 1253\u20131272. https:\/\/doi.org\/10.1177\/09544119221108540 (2022).","journal-title":"Proc Inst Mech Eng H."},{"key":"43182_CR10","doi-asserted-by":"crossref","unstructured":"Stoffel, K., Dieter, U., Stachowiak, G., G\u00e4chter, A. &  Kuster, M. S. Biomechanical testing of the LCP \u2013 how can stability in locked internal fixators be controlled? Injury [Internet]. 2003 Nov 1 [cited 2025 Jul 31];34(SUPPL. 2), 11\u20139 (2009). Available from: https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0020138303003796?via%3Dihub","DOI":"10.1016\/j.injury.2003.09.021"},{"key":"43182_CR11","doi-asserted-by":"crossref","unstructured":"Kurtz, S. M. & Devine, J. N. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials [Internet]. 2007 Nov 1 [cited 2025 Jul 31];28(32), 4845\u201369 (2007). Available from: https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0142961207005467?via%3Dihub","DOI":"10.1016\/j.biomaterials.2007.07.013"},{"key":"43182_CR12","doi-asserted-by":"crossref","unstructured":"Hu, Z., He, J., Chen, W., Liu, W., Ding, J. & He, C. et al. High-performance carbon fiber reinforced polyether-ether-ketone composite pellets 3D-Printed via screw-extrusion additive manufacturing. Compos. Sci. Technol. [Internet]. 2024 Feb 8 [cited 2025 Jul 31];246, 110362 (2024). Available from: https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0266353823004566?via%3Dihub","DOI":"10.1016\/j.compscitech.2023.110362"},{"key":"43182_CR13","doi-asserted-by":"publisher","DOI":"10.1115\/1.4068226","author":"AF Bologna","year":"2025","unstructured":"Bologna, A. F. et al. In silico evaluation of the primary stability of acetabular revision cups: Standard versus locking screws. J. Biomech. Eng. https:\/\/doi.org\/10.1115\/1.4068226 (2025).","journal-title":"J. Biomech. Eng."},{"issue":"11","key":"43182_CR14","doi-asserted-by":"publisher","first-page":"576","DOI":"10.3390\/jcs9110576","volume":"9","author":"M Ceddia","year":"2025","unstructured":"Ceddia, M., Pesare, E., Solarino, G., Lamberti, L. & Trentadue, B. Biomechanical Comparison of Titanium and CFR-PEEK Intramedullary Nails Using Finite Element Analysis. J. Compos. Sci. 9(11), 576 (2025).","journal-title":"J. Compos. Sci."},{"issue":"10","key":"43182_CR15","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1080\/10255842.2020.1867114","volume":"24","author":"S Beirami","year":"2021","unstructured":"Beirami, S., Nikkhoo, M., Hassani, K. & Karimi, A. A comparative finite element simulation of locking compression plate materials for tibial fracture treatment. Comput. Methods Biomech. Biomed. Eng. 24(10), 1064\u20131072. https:\/\/doi.org\/10.1080\/10255842.2020.1867114 (2021).","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"issue":"6","key":"43182_CR16","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1007\/s00590-015-1604-7","volume":"25","author":"J Zhang","year":"2015","unstructured":"Zhang, J. et al. External fixation using locking plate in distal tibial fracture: A finite element analysis. Eur. J. Orthop. Surg. Traumatol. 25(6), 1099\u20131104. https:\/\/doi.org\/10.1007\/s00590-015-1604-7 (2015).","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"issue":"1","key":"43182_CR17","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-025-97090-4","volume":"15","author":"BW Ng","year":"2025","unstructured":"Ng, B. W. et al. Finite element analysis and clinical evaluation of cross locking external fixator configuration for distal third tibia fracture. Sci. Rep. 15(1), 13310. https:\/\/doi.org\/10.1038\/s41598-025-97090-4 (2025).","journal-title":"Sci. Rep."},{"issue":"1","key":"43182_CR18","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-025-08530-1","volume":"26","author":"X Ye","year":"2025","unstructured":"Ye, X., Luo, J., Chen, P., Wei, X. & Liu, S. Finite element analysis of the stability of tibiofibular fractures treated with various combinations of external fixators. BMC. Musculoskelet. Disord. 26(1), 304. https:\/\/doi.org\/10.1186\/s12891-025-08530-1 (2025).","journal-title":"BMC. Musculoskelet. Disord."},{"issue":"1","key":"43182_CR19","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-020-01904-2","volume":"15","author":"R Tian","year":"2020","unstructured":"Tian, R. et al. Prevalence and influencing factors of nonunion in patients with tibial fracture: Systematic review and meta-analysis. J. Orthop. Surg. Res. 15(1), 377. https:\/\/doi.org\/10.1186\/s13018-020-01904-2 (2020).","journal-title":"J. Orthop. Surg. Res."},{"issue":"1","key":"43182_CR20","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-021-02814-7","volume":"16","author":"Z Ye","year":"2021","unstructured":"Ye, Z. et al. Study on the relationship between the timing of conversion from external fixation to internal fixation and infection in the treatment of open fractures of extremities. J. Orthop. Surg. Res. 16(1), 662. https:\/\/doi.org\/10.1186\/s13018-021-02814-7 (2021).","journal-title":"J. Orthop. Surg. Res."},{"key":"43182_CR21","doi-asserted-by":"crossref","unstructured":"Schmidt, A. H. The Impact of Compartment Syndrome on Hospital Length of Stay and Charges Among Adult Patients Admitted With a Fracture of the Tibia. J. Orthop. Trauma. [Internet]. 25(6), 355\u2013357 (2011). Available from: https:\/\/journals.lww.com\/jorthotrauma\/fulltext\/2011\/06000\/the_impact_of_compartment_syndrome_on_hospital.7.aspx","DOI":"10.1097\/BOT.0b013e3181f18ad8"},{"key":"43182_CR22","doi-asserted-by":"crossref","unstructured":"Ahmad, M. A., Sivaraman, A., Zia, A., Rai, A. & Patel, A. D. Percutaneous locking plates for fractures of the distal tibia: Our experience and a review of the literature. J. Trauma. Acute. Care. Surg. [Internet]. 72(2) (2012). Available from: https:\/\/journals.lww.com\/jtrauma\/fulltext\/2012\/02000\/percutaneous_locking_plates_for_fractures_of_the.53.aspx","DOI":"10.1097\/TA.0b013e3181f140b3"},{"key":"43182_CR23","doi-asserted-by":"crossref","unstructured":"Zhang, J., Ebraheim, N. A., Li, M., He, X., Liu, J. & Zhu, L. et al. External Fixation Using a Locking Plate: A Reliable Way in Treating Distal Tibial Fractures. J. Orthop. Trauma. [Internet]. 29(11), (2015). Available from: https:\/\/journals.lww.com\/jorthotrauma\/fulltext\/2015\/11000\/external_fixation_using_a_locking_plate__a.15.aspx","DOI":"10.1097\/BOT.0000000000000377"},{"key":"43182_CR24","doi-asserted-by":"publisher","unstructured":"Su, H., Zhong, S., Ma, T., Wu, W., Lu, Y. & Wang, D. Biomechanical study of the stiffness of the femoral locking compression plate of an external fixator for lower tibial fractures. BMC Musculoskelet Disord [Internet].  24(1), 39 (2023). Available from: https:\/\/doi.org\/10.1186\/s12891-023-06150-1","DOI":"10.1186\/s12891-023-06150-1"},{"issue":"4","key":"43182_CR25","doi-asserted-by":"publisher","first-page":"1600","DOI":"10.3390\/jcm12041600","volume":"12","author":"B Makelov","year":"2023","unstructured":"Makelov, B. et al. Single-Stage Externalized Locked Plating for Treatment of Unstable Meta-Diaphyseal Tibial Fractures. J. Clin. Med. 12(4), 1600 (2023).","journal-title":"J Clin Med."},{"issue":"1","key":"43182_CR26","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1186\/s13018-021-02907-3","volume":"17","author":"D Bla\u017eevi\u0107","year":"2022","unstructured":"Bla\u017eevi\u0107, D. et al. Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis. J. Orthop. Surg. Res. 17(1), 16 (2022).","journal-title":"J Orthop Surg Res."},{"issue":"1","key":"43182_CR27","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1186\/s13018-023-04307-1","volume":"18","author":"S Fang","year":"2023","unstructured":"Fang, S. et al. Finite element analysis comparison of Type 42A2 fracture fixed with external titanium alloy locking plate and traditional external fixation frame. J. Orthop. Surg. Res. 18(1), 815 (2023).","journal-title":"J Orthop Surg Res."},{"issue":"1","key":"43182_CR28","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1186\/s13018-025-05681-8","volume":"20","author":"S Liu","year":"2025","unstructured":"Liu, S. et al. A novel external fixation for treating tibial fractures: a finite element and biomechanical study. J. Orthop. Surg. Res. 20(1), 319 (2025).","journal-title":"J Orthop Surg Res."},{"issue":"3","key":"43182_CR29","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1007\/s00256-018-3051-0","volume":"48","author":"JS Fisher","year":"2019","unstructured":"Fisher, J. S., Kazam, J. J., Fufa, D. & Bartolotta, R. J. Radiologic evaluation of fracture healing. Skeletal. Radiol. 48(3), 349\u201361. https:\/\/doi.org\/10.1007\/s00256-018-3051-0 (2019).","journal-title":"Skeletal Radiol."},{"key":"43182_CR30","doi-asserted-by":"crossref","unstructured":"Govaert, G. A. M., Kuehl, R., Atkins, B. L., Trampuz, A., Morgenstern, M. & Obremskey, W. T. et al. Diagnosing Fracture-Related Infection: Current Concepts and Recommendations. J. Orthop. Trauma. [Internet]. 34(1), (2020). Available from: https:\/\/journals.lww.com\/jorthotrauma\/fulltext\/2020\/01000\/diagnosing_fracture_related_infection__current.3.aspx","DOI":"10.1097\/BOT.0000000000001614"},{"key":"43182_CR31","doi-asserted-by":"publisher","first-page":"750","DOI":"10.3390\/bioengineering9120750","volume":"9","author":"DW Flowers","year":"2022","unstructured":"Flowers, D. W., McCallister, E., Christopherson, R. & Ware, E. The Safety and Effectiveness of Early, Progressive Weight Bearing and Implant Choice after Traumatic Lower Extremity Fracture: A Systematic Review. Bioengineering. 9, 750 (2022).","journal-title":"Bioengineering."},{"key":"43182_CR32","doi-asserted-by":"publisher","unstructured":"Panayotov, I. V., Orti, V., Cuisinier, F. & Yachouh, J. Polyetheretherketone (PEEK) for medical applications. J. Mater. Sci. Mater. Med. [Internet]. 27(7), 118 (2016). Available from: https:\/\/doi.org\/10.1007\/s10856-016-5731-4","DOI":"10.1007\/s10856-016-5731-4"},{"issue":"4","key":"43182_CR33","doi-asserted-by":"publisher","first-page":"2163","DOI":"10.1007\/s10143-020-01384-2","volume":"44","author":"T Kr\u00e4tzig","year":"2021","unstructured":"Kr\u00e4tzig, T. et al. Carbon fiber\u2013reinforced PEEK versus titanium implants: An in vitro comparison of susceptibility artifacts in CT and MR imaging. Neurosurg. Rev. 44(4), 2163\u20132170. https:\/\/doi.org\/10.1007\/s10143-020-01384-2 (2021).","journal-title":"Neurosurg. Rev."},{"key":"43182_CR34","doi-asserted-by":"crossref","unstructured":"Yu, W., Li, X., Ma, X. & Xu, X. Biomechanical analysis of inclined and cantilever design with different implant framework materials in mandibular complete-arch implant restorations. J. Prosthet. Dent. [Internet]. 2022 May 1 [cited 2025 Jul 31];127(5), 783.e1\u2013783.e10 (2022). Available from: https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0022391322001433?via%3Dihub","DOI":"10.1016\/j.prosdent.2022.02.018"},{"key":"43182_CR35","doi-asserted-by":"crossref","unstructured":"M\u00fcther, M., L\u00fcthge, S., Gerwing, M., Stummer, W. & Schwake, M. Management of Spinal Dumbbell Tumors via a Minimally Invasive Posterolateral Approach and Carbon Fiber\u2013Reinforced Polyether Ether Ketone Instrumentation: Technical Note and Surgical Case Series. World Neurosurg. [Internet]. 2021 Jul 1 [cited 2025 Jul 31];151, 277\u2013283.e1 (2021). Available from: https:\/\/www.sciencedirect.com\/science\/article\/pii\/S1878875021006094?via%3Dihub","DOI":"10.1016\/j.wneu.2021.04.068"},{"key":"43182_CR36","doi-asserted-by":"crossref","unstructured":"Guo, Y., Chen, C., Zhang, S., Ren, L., Zhao, Y. & Guo, W. Mediation of mechanically adapted TiCu\/TiCuN\/CFR-PEEK implants in vascular regeneration to promote bone repair in vitro and in vivo. J. Orthop. Translat. [Internet]. 2022 Mar 1 [cited 2025 Jul 31];33, 107\u201319 (2025). Available from: https:\/\/www.sciencedirect.com\/science\/article\/pii\/S2214031X22000122?via%3Dihub","DOI":"10.1016\/j.jot.2022.02.008"},{"key":"43182_CR37","doi-asserted-by":"crossref","unstructured":"Yang, Z., Guo, W., Yang, W., Song, J., Hu, W. & Wang, K. Polyetheretherketone biomaterials and their current progress, modification-based biomedical applications and future challenges. Mater. Des. [Internet]. 2025 Apr 1 [cited 2025 Jul 31];252, 113716 (2025). Available from: https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0264127525001364?via%3Dihub","DOI":"10.1016\/j.matdes.2025.113716"},{"key":"43182_CR38","doi-asserted-by":"crossref","unstructured":"Theivendran, K., Arshad, F., Hanif, U. K., Reito, A., Griffin, X. & Foote, C. J. Carbon fibre reinforced PEEK versus traditional metallic implants for orthopaedic trauma surgery: A systematic review. J. Clin. Orthop. Trauma. [Internet]. 2021 Dec 1 [cited 2025 Jul 31];23, 101674 (2025). Available from: https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0976566221005580?via%3Dihub","DOI":"10.1016\/j.jcot.2021.101674"},{"issue":"1","key":"43182_CR39","doi-asserted-by":"publisher","DOI":"10.1186\/s12957-018-1545-9","volume":"16","author":"CJ Laux","year":"2018","unstructured":"Laux, C. J., Hodel, S. M., Farshad, M. & M\u00fcller, D. A. Carbon fibre\/polyether ether ketone (CF\/PEEK) implants in orthopaedic oncology. World J. Surg. Oncol. 16(1), 241. https:\/\/doi.org\/10.1186\/s12957-018-1545-9 (2018).","journal-title":"World J. Surg. Oncol."},{"key":"43182_CR40","unstructured":"Perren, S. M. Current concepts of internal fixation of fractures. Manual Inter. Fix. 63\u201377 (1980)."},{"key":"43182_CR41","doi-asserted-by":"crossref","unstructured":"Torstrick, F. B., Safranski, D. L., Burkus, J. K., Chappuis, J. L., Lee, C. S.D. & Guldberg, R. E. et al. Getting PEEK to Stick to Bone: The Development of Porous PEEK for Interbody Fusion Devices. Tech. Orthop. [Internet].  32(3), (2017). Available from: https:\/\/journals.lww.com\/techortho\/fulltext\/2017\/09000\/getting_peek_to_stick_to_bone__the_development_of.5.aspx","DOI":"10.1097\/BTO.0000000000000242"},{"issue":"1","key":"43182_CR42","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1186\/s40824-023-00407-5","volume":"27","author":"Z Chen","year":"2023","unstructured":"Chen, Z. et al. Polyetheretherketone implants with hierarchical porous structure for boosted osseointegration. Biomater. Res. 27(1), 61. https:\/\/doi.org\/10.1186\/s40824-023-00407-5 (2023).","journal-title":"Biomater Res."},{"issue":"4","key":"43182_CR43","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/s10195-014-0311-1","volume":"15","author":"L Tarallo","year":"2014","unstructured":"Tarallo, L., Mugnai, R., Adani, R., Zambianchi, F. & Catani, F. A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: Analysis of 40 cases. J. Orthop. Traumatol. 15(4), 277\u2013283. https:\/\/doi.org\/10.1007\/s10195-014-0311-1 (2014).","journal-title":"J. Orthop. Traumatol."},{"issue":"11","key":"43182_CR44","doi-asserted-by":"publisher","DOI":"10.1002\/advs.202105499","volume":"9","author":"X Hu","year":"2022","unstructured":"Hu, X. et al. Laser direct-write sensors on carbon-fiber-reinforced poly-ether\u2013ether\u2013ketone for smart orthopedic implants. Adv. Sci. 9(11), 2105499. https:\/\/doi.org\/10.1002\/advs.202105499 (2022).","journal-title":"Adv. Sci."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-43182-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-43182-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-43182-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,26]],"date-time":"2026-04-26T23:45:44Z","timestamp":1777247144000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-43182-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,14]]},"references-count":44,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["43182"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-43182-8","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,14]]},"assertion":[{"value":"12 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declartions"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"13506"}}