{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T21:53:23Z","timestamp":1781646803286,"version":"3.54.5"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,28]],"date-time":"2026-03-28T00:00:00Z","timestamp":1774656000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T00:00:00Z","timestamp":1774915200000},"content-version":"vor","delay-in-days":3,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Fujian Clinical Research Center for Digestive System Tumors and Upper Gastrointestinal Diseases"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Non-compliant final rinse water (microbial culture results exceeding 10\u00a0cfu\/100 mL) is an under-recognized risk factor for failure of flexible gastrointestinal (GI) endoscope reprocessing, since it is an important step following disinfection during the reprocessing of flexible endoscopes. Opportunistic premise plumbing pathogens (OPPPs) may colonize terminal segments of the water distribution system and compromise rinse water quality. This study investigated the cause of recurrent final rinse water non-compliance in a GI endoscopy unit and evaluated an engineering intervention to prevent it. During August 2024, samples were collected from 34 reprocessed flexible gastrointestinal endoscopes (102 post-reprocessing samples) and various points within the water delivery system, including purified water and final rinse water from automated endoscope reprocessors and manual washing tanks. All samples were subsequently cultured for microbial analysis. After contaminated connecting tubes were identified as a potential OPPPs reservoir, 10 tubes between the circulation loop and the reprocessing equipment were replaced, and surveillance cultures were repeated at the same sampling sites. Initial assessments revealed low compliance rates of 32 water samples (37.5%, 12\/32), according to infection control standards (\u2264\u200910\u00a0cfu\/100 mL). Water samples collected before connecting tubes showed 100% compliance (12\/12 samples). Water collected through connecting tubes and final rinse taps all showed 0% compliance (0\/10 samples), except for the water sample from AER 6, which had a bacterial count of 75\u00a0cfu\/100mL, all other samples contained too numerous bacteria and could not be counted. The dominant bacteria is\n                    <jats:italic>Sphingomonas paucimobilis<\/jats:italic>\n                    , which was found in 14 samples, with a composition ratio is 43.75% (14\/32). Others are\n                    <jats:italic>Methylobacterium oryzae<\/jats:italic>\n                    (8\/32, 25%),\n                    <jats:italic>Chryseobacterium indologenes<\/jats:italic>\n                    (6\/32, 18.75%), and\n                    <jats:italic>Herbaspirillum huttiense<\/jats:italic>\n                    (2\/32, 6.25%). After replacing the connecting tubes, the compliance rate of water samples developed significantly to 100% (32\/32) (\n                    <jats:italic>P<\/jats:italic>\n                    \u2009=\u20096.9\u2009\u00d7\u200910\n                    <jats:sup>\u2212\u20098<\/jats:sup>\n                    ). The primary reason for non-compliance of final rinse water is the contamination of connecting tube by the OPPPs. These findings emphasize the need for shortening the connecting tube length and thorough cleaning and disinfecting of connecting tube between circulating tube and endoscope reprocessor, which are generally neglected in routine maintenance.\n                  <\/jats:p>","DOI":"10.1038\/s41598-026-46256-9","type":"journal-article","created":{"date-parts":[[2026,3,28]],"date-time":"2026-03-28T15:48:43Z","timestamp":1774712923000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Investigation of microbiological non-compliance of endoscopic final rinse water associated with opportunistic premise plumbing pathogens contamination in connecting tube"],"prefix":"10.1038","volume":"16","author":[{"given":"Miao","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingqing","family":"Zu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Linwen","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lirong","family":"Wen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shanshan","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuli","family":"Nie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fenglin","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiaoyu","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,28]]},"reference":[{"key":"46256_CR1","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.gie.2020.09.048","volume":"93","author":"LW Day","year":"2021","unstructured":"Day, L. W. et al. Multisociety guideline on reprocessing flexible GI endoscopes and accessories. Gastrointest. Endosc. 93, 11\u201333e6 (2021).","journal-title":"Gastrointest. Endosc."},{"key":"46256_CR2","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.1016\/j.ajic.2013.04.022","volume":"41","author":"AM Dirlam Langlay","year":"2013","unstructured":"Dirlam Langlay, A. M. et al. Reported gastrointestinal endoscope reprocessing lapses: the tip of the iceberg. Am. J. Infect. Control. 41, 1188\u20131194 (2013).","journal-title":"Am. J. Infect. Control"},{"key":"46256_CR3","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/j.jhin.2022.09.024","volume":"131","author":"B Casini","year":"2023","unstructured":"Casini, B. et al. Microbiological surveillance post-reprocessing of flexible endoscopes used in digestive endoscopy: a national study. J. Hosp. Infect. 131, 139\u2013147 (2023).","journal-title":"J. Hosp. Infect."},{"key":"46256_CR4","doi-asserted-by":"publisher","first-page":"930","DOI":"10.1016\/j.gie.2024.05.026","volume":"100","author":"B Jin","year":"2024","unstructured":"Jin, B. et al. Investigation of failure of flexible GI endoscope disinfection because of Burkholderia cepacia contamination in irrigation tubing. Gastrointest. Endosc. 100, 930\u2013934 (2024).","journal-title":"Gastrointest. Endosc."},{"key":"46256_CR5","doi-asserted-by":"crossref","unstructured":"Falkinham, J. O. Living with Legionella and other waterborne pathogens. Microorganisms 8, 2026\u20132036 (2020).","DOI":"10.3390\/microorganisms8122026"},{"key":"46256_CR6","doi-asserted-by":"crossref","unstructured":"Masaka, E. et al. Opportunistic premise plumbing pathogens. A potential health risk in water mist systems used as a cooling intervention. Pathogens 10, 462\u2013479 (2021).","DOI":"10.3390\/pathogens10040462"},{"key":"46256_CR7","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.jhin.2012.10.016","volume":"83","author":"O Bajolet","year":"2013","unstructured":"Bajolet, O. et al. Gastroscopy-associated transmission of extended-spectrum beta-lactamase-producing Pseudomonas aeruginosa. J. Hosp. Infect. 83, 341\u2013343 (2013).","journal-title":"J. Hosp. Infect."},{"key":"46256_CR8","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.jhin.2004.12.020","volume":"61","author":"JC C\u00eatre","year":"2005","unstructured":"C\u00eatre, J. C. et al. Outbreaks of contaminated broncho-alveolar lavage related to intrinsically defective bronchoscopes. J. Hosp. Infect. 61, 39\u201345 (2005).","journal-title":"J. Hosp. Infect."},{"key":"46256_CR9","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.jhin.2013.06.010","volume":"85","author":"CL Chang","year":"2013","unstructured":"Chang, C. L. et al. Outbreak of ertapenem-resistant Enterobacter cloacae urinary tract infections due to a contaminated ureteroscope. J. Hosp. Infect. 85, 118\u2013124 (2013).","journal-title":"J. Hosp. Infect."},{"key":"46256_CR10","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1016\/j.ajic.2019.11.019","volume":"48","author":"S Campos-Guti\u00e9rrez","year":"2020","unstructured":"Campos-Guti\u00e9rrez, S. et al. Pseudo-outbreak of Mycobacterium fortuitum in a hospital bronchoscopy unit. Am. J. Infect. Control. 48, 765\u2013769 (2020).","journal-title":"Am. J. Infect. Control"},{"key":"46256_CR11","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1086\/502263","volume":"24","author":"PY Levy","year":"2003","unstructured":"Levy, P. Y. et al. A nosocomial outbreak of Legionella pneumophila caused by contaminated transesophageal echocardiography probes. Infect. Control Hosp. Epidemiol. 24, 619\u2013622 (2003).","journal-title":"Infect. Control Hosp. Epidemiol."},{"key":"46256_CR12","doi-asserted-by":"publisher","first-page":"4533","DOI":"10.3390\/ijerph120504533","volume":"12","author":"J Falkinham","year":"2015","unstructured":"Falkinham, J. Common Features of Opportunistic Premise Plumbing Pathogens. Int. J. Environ. Res. Public Health. 12, 4533\u20134545 (2015).","journal-title":"Int. J. Environ. Res. Public Health"},{"key":"46256_CR13","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.ajic.2019.06.013","volume":"48","author":"Y Zhang","year":"2020","unstructured":"Zhang, Y. et al. Bronchoscope-related Pseudomonas aeruginosa pseudo-outbreak attributed to contaminated rinse water. Am. J. Infect. Control. 48, 26\u201332 (2020).","journal-title":"Am. J. Infect. Control"},{"key":"46256_CR14","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.1080\/03639040600920614","volume":"32","author":"M Florjanic","year":"2006","unstructured":"Florjanic, M. & Kristl, J. Microbiological quality assurance of purified water by ozonization of storage and distribution system. Drug Dev. Ind. Pharm. 32, 1113\u20131121 (2006).","journal-title":"Drug Dev. Ind. Pharm."},{"key":"46256_CR15","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1289\/ehp.1408692","volume":"123","author":"JO Falkinham","year":"2015","unstructured":"Falkinham, J. O. et al. Epidemiology and Ecology of Opportunistic Premise Plumbing Pathogens: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa. Environ. Health Perspect. 123, 749\u2013758 (2015).","journal-title":"Environ. Health Perspect."},{"key":"46256_CR16","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1016\/j.jhin.2017.07.012","volume":"97","author":"J Kovaleva","year":"2017","unstructured":"Kovaleva, J. Endoscope drying and its pitfalls. J. Hosp. Infect. 97, 319\u2013328 (2017).","journal-title":"J. Hosp. Infect."},{"key":"46256_CR17","doi-asserted-by":"publisher","first-page":"2147","DOI":"10.1111\/j.1572-0241.2006.00712.x","volume":"101","author":"LF Muscarella","year":"2006","unstructured":"Muscarella, L. F. Inconsistencies in endoscope-reprocessing and infection-control guidelines: the importance of endoscope drying. Am. J. Gastroenterol. 101, 2147\u20132154 (2006).","journal-title":"Am. J. Gastroenterol."},{"key":"46256_CR18","doi-asserted-by":"publisher","first-page":"e43","DOI":"10.1016\/j.ajic.2018.04.216","volume":"46","author":"XY Ji","year":"2018","unstructured":"Ji, X. Y. et al. Microbiologic assessment of flexible gastrointestinal endoscope reprocessing using a pump-assisted sampling technique: an investigation involving all endoscopy units in Tianjin, China. Am. J. Infect. Control. 46, e43\u2013e8 (2018).","journal-title":"Am. J. Infect. Control"},{"key":"46256_CR19","doi-asserted-by":"crossref","unstructured":"Petersen, B. T., Cohen, J. & Hambrick, R. D. 3 rd et al. Multisociety guideline on reprocessing flexible GI endoscopes: 2016 update. Gastrointest. Endosc. 85, 282\u2013294.e1 (2017).","DOI":"10.1016\/j.gie.2016.10.002"},{"key":"46256_CR20","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1186\/s13756-025-01560-3","volume":"14","author":"Z Li","year":"2025","unstructured":"Li, Z. et al. Management and microbial monitoring of final rinse water for flexible endoscopes in 290 hospitals in Jiangsu Province, China: a multicenter cross-sectional study. Antimicrob. Resist. Infect. Control. 14, 40 (2025).","journal-title":"Antimicrob. Resist. Infect. Control"},{"key":"46256_CR21","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1017\/ice.2018.298","volume":"40","author":"JL Seidelman","year":"2019","unstructured":"Seidelman, J. L. et al. Mycobacterium avium pseudo-outbreak associated with an outpatient bronchoscopy clinic: Lessons for reprocessing. Infect. Control Hosp. Epidemiol. 40, 106\u2013108 (2019).","journal-title":"Infect. Control Hosp. Epidemiol."},{"key":"46256_CR22","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1086\/591451","volume":"29","author":"A Chroneou","year":"2008","unstructured":"Chroneou, A. et al. Molecular typing of Mycobacterium chelonae isolates from a pseudo-outbreak involving an automated bronchoscope washer. Infect. Control Hosp. Epidemiol. 29, 1088\u20131090 (2008).","journal-title":"Infect. Control Hosp. Epidemiol."},{"key":"46256_CR23","doi-asserted-by":"publisher","first-page":"e221","DOI":"10.1016\/j.ajic.2016.06.019","volume":"44","author":"T Guimar\u00e3es","year":"2016","unstructured":"Guimar\u00e3es, T. et al. Pseudooutbreak of rapidly growing mycobacteria due to Mycobacterium abscessus subsp bolletii in a digestive and respiratory endoscopy unit caused by the same clone as that of a countrywide outbreak. Am. J. Infect. Control. 44, e221\u2013e6 (2016).","journal-title":"Am. J. Infect. Control"},{"key":"46256_CR24","doi-asserted-by":"publisher","first-page":"769","DOI":"10.1086\/653611","volume":"31","author":"D Rosengarten","year":"2010","unstructured":"Rosengarten, D. et al. Cluster of pseudoinfections with Burkholderia cepacia associated with a contaminated washer-disinfector in a bronchoscopy unit. Infect. Control Hosp. Epidemiol. 31, 769\u2013771 (2010).","journal-title":"Infect. Control Hosp. Epidemiol."},{"key":"46256_CR25","doi-asserted-by":"publisher","first-page":"144248","DOI":"10.1016\/j.chemosphere.2025.144248","volume":"376","author":"M Cazals","year":"2025","unstructured":"Cazals, M. et al. What happens in your water system? Impact of materials, temperature, stagnation and chlorination on water quality and biofilm formation. Chemosphere 376, 144248 (2025).","journal-title":"Chemosphere"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-46256-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-46256-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-46256-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T21:05:05Z","timestamp":1781643905000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-46256-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,28]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["46256"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-46256-9","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,28]]},"assertion":[{"value":"5 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was conducted in vitro and did not involve human subjects. Written informed consent was not required, as per the guidelines of the institutional ethics, biosecurity, and research committees, since the bacterial strains used were sourced from clinical environment in hospitals.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All the authors read and approved the final manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10783"}}