{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T00:47:05Z","timestamp":1782089225505,"version":"3.54.5"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T00:00:00Z","timestamp":1777248000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T00:00:00Z","timestamp":1782086400000},"content-version":"vor","delay-in-days":56,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Reyon Pharmaceutical Co., Ltd. (Seoul, Republic of Korea) , the Korea Medical Device Development Fund grant funded by the Korean government"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    To evaluate the image quality and diagnostic performance of a newly developed three-dimensional automated breast ultrasound (ABUS) system, MammouS-N, characterized by mammography-like geometry.  In this prospective study of 121 women with 139 breast lesions, MammouS-N images were obtained in three different projections and reviewed in consensus by two breast radiologists blinded to prior imaging and pathology. Image quality was rated for six parameters. Lesion detectability and BI-RADS categories were compared between MammouS-N and hand-held ultrasound (HHUS), and their concordance was assessed using \u03ba statistics. Diagnostic performance was assessed using the receiver operating characteristic (ROC) analysis with pathology as the reference standard. MammouS-N achieved diagnostically acceptable image quality (score\u2009\u2265\u20094) in over 90% of cases and near-complete coverage in 98.6% of breasts. Of 139 lesions, 131 (94.2%) were visualized, including 88 of 92 malignant lesions (95.7%). The area under the ROC curve for malignancy detection was 0.893 for MammouS-N (95% CI, 0.844\u20130.943) and 0.923 (95% CI, 0.885\u20130.962) for HHUS, without a significant difference (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009=\u20090.207). BI-RADS concordance between MammouS-N and HHUS showed moderate-to-substantial agreement (Cohen\u2019s \u03ba\u2009=\u20090.45; weighted \u03ba\u2009=\u20090.65), with a mild benign-leaning tendency, as downgrades exceeded upgrades (2.1% of benign and 12.0% of malignant lesions were downgraded relative to HHUS.  MammouS-N demonstrated high image quality, excellent lesion detectability, and comparable diagnostic concordance with HHUS. Its mammography-aligned geometry facilitates spatial correspondence across modalities, supporting its potential as a complementary imaging tool for breast cancer screening.\n                  <\/jats:p>","DOI":"10.1038\/s41598-026-48519-x","type":"journal-article","created":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T05:53:13Z","timestamp":1777269193000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of breast lesions using a newly developed 3D breast ultrasound imaging device: a preliminary study on efficacy and validity"],"prefix":"10.1038","volume":"16","author":[{"given":"Miribi","family":"Rho","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyunghwa","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min Jung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,27]]},"reference":[{"key":"48519_CR1","doi-asserted-by":"crossref","unstructured":"Kim, J. et al. Global patterns and trends in breast cancer incidence and mortality across 185 countries. Nat.  Med. (2025).","DOI":"10.1038\/s41591-025-03502-3"},{"key":"48519_CR2","doi-asserted-by":"crossref","unstructured":"G\u00f8tzsche, P. C. & J\u00f8rgensen, K. J. Screening for breast cancer with mammography. Cochrane Database Syst. Rev. 2013, Cd001877, (2013).","DOI":"10.1002\/14651858.CD001877.pub5"},{"key":"48519_CR3","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1148\/radiol.2251011667","volume":"225","author":"TM Kolb","year":"2002","unstructured":"Kolb, T. M., Lichy, J. & Newhouse, J. H. Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations. Radiology 225, 165\u2013175 (2002).","journal-title":"Radiology"},{"key":"48519_CR4","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1056\/NEJMoa062790","volume":"356","author":"NF Boyd","year":"2007","unstructured":"Boyd, N. F. et al. Mammographic density and the risk and detection of breast cancer. N Engl. J. Med. 356, 227\u2013236 (2007).","journal-title":"N Engl. J. Med."},{"key":"48519_CR5","doi-asserted-by":"publisher","first-page":"2151","DOI":"10.1001\/jama.299.18.2151","volume":"299","author":"WA Berg","year":"2008","unstructured":"Berg, W. A. et al. Combined screening with ultrasound and mammography vs mammography alone in women at elevated risk of breast cancer. Jama 299, 2151\u20132163 (2008).","journal-title":"Jama"},{"key":"48519_CR6","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1148\/radiol.2412051710","volume":"241","author":"WA Berg","year":"2006","unstructured":"Berg, W. A., Blume, J. D., Cormack, J. B. & Mendelson, E. B. Operator dependence of physician-performed whole-breast US: lesion detection and characterization. Radiology 241, 355\u2013365 (2006).","journal-title":"Radiology"},{"key":"48519_CR7","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1007\/s00330-009-1588-y","volume":"20","author":"KM Kelly","year":"2010","unstructured":"Kelly, K. M., Dean, J., Comulada, W. S. & Lee, S. J. Breast cancer detection using automated whole breast ultrasound and mammography in radiographically dense breasts. Eur. Radiol. 20, 734\u2013742 (2010).","journal-title":"Eur. Radiol."},{"key":"48519_CR8","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1016\/j.ejrad.2011.02.038","volume":"81","author":"X Lin","year":"2012","unstructured":"Lin, X., Wang, J., Han, F., Fu, J. & Li, A. Analysis of eighty-one cases with breast lesions using automated breast volume scanner and comparison with handheld ultrasound. Eur. J. Radiol. 81, 873\u2013878 (2012).","journal-title":"Eur. J. Radiol."},{"key":"48519_CR9","doi-asserted-by":"publisher","first-page":"3712","DOI":"10.1007\/s00330-020-07573-3","volume":"31","author":"B Sch\u00e4fgen","year":"2021","unstructured":"Sch\u00e4fgen, B. et al. Evaluation of the FUSION-X-US-II prototype to combine automated breast ultrasound and tomosynthesis. Eur. Radiol. 31, 3712\u20133720 (2021).","journal-title":"Eur. Radiol."},{"key":"48519_CR10","doi-asserted-by":"publisher","first-page":"2499","DOI":"10.1007\/s00330-017-5235-8","volume":"28","author":"B Schaefgen","year":"2018","unstructured":"Schaefgen, B. et al. Initial results of the FUSION-X-US prototype combining 3D automated breast ultrasound and digital breast tomosynthesis. Eur. Radiol. 28, 2499\u20132506 (2018).","journal-title":"Eur. Radiol."},{"key":"48519_CR11","unstructured":"D\u2019Orsi, C. J., Sickles, E. A., Mendelson, E. B. & Morris, E. A. ACR BI-RADS Atlas: Breast Imaging Reporting and Data System (American College of Radiology, 2013)."},{"key":"48519_CR12","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1016\/j.rcl.2014.01.002","volume":"52","author":"SS Kaplan","year":"2014","unstructured":"Kaplan, S. S. Automated Whole Breast Ultrasound. Radiol. Clin. North Am. 52, 539\u2013546 (2014).","journal-title":"Radiol. Clin. North Am."},{"key":"48519_CR13","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1007\/s00404-021-06081-z","volume":"304","author":"B Schaefgen","year":"2021","unstructured":"Schaefgen, B. et al. First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers. Arch. Gynecol. Obstet. 304, 559\u2013566 (2021).","journal-title":"Arch. Gynecol. Obstet."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-48519-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-48519-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-48519-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,21]],"date-time":"2026-06-21T23:47:05Z","timestamp":1782085625000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-48519-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,27]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["48519"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-48519-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,27]]},"assertion":[{"value":"28 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"19298"}}