{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T22:34:02Z","timestamp":1792794842669,"version":"4.5.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T00:00:00Z","timestamp":1776988800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T00:00:00Z","timestamp":1781740800000},"content-version":"vor","delay-in-days":55,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003399","name":"Shanghai Science and Technology Commission","doi-asserted-by":"crossref","award":["25SF1904300"],"award-info":[{"award-number":["25SF1904300"]}],"id":[{"id":"10.13039\/501100003399","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Investigating the impact of coil embolization rate on hemodynamic parameters within the aneurysm sac after treating anterior circulation small and medium-sized aneurysms with the Tubridge (TB) flow diverter. Twenty-six patients with 29 intracranial aneurysms were collected between September 2020 and December 2022. The finite element method simulated preoperative conditions, after TB deployment alone, and with TB plus different coil embolization rates. Different hemodynamic parameters were analyzed under these treatment scenarios. Variance analysis and multiple comparisons were conducted to find an appropriate embolization rate. Twenty-nine aneurysms from 26 patients showed, with increasing TB deployment and coil embolization rates, a continuous improvement in the aneurysm sac\u2019s Qinflow, Va, WSS, and normalized and ratio residual blood volume (nRFV and rRFV) under different thresholds (0.1\u00a0m\/s, 0.15\u00a0m\/s). Quantitative analysis indicated the impact on hemodynamics was not significant (\n                    <jats:italic>P<\/jats:italic>\n                    \u2009&gt;\u20090.05) when the coil embolization rate reached 5% and beyond for Qinflow, Va, WSS, and RFV under different thresholds (0.1\u00a0m\/s, 0.15\u00a0m\/s). Adjunctive embolization can improve the hemodynamic environment within the small and medium-sized aneurysm sac when using the Tubridge flow diverter. However, once the embolization rate within the sac reaches 5%, the hemodynamic environment tends to stabilize, making dense embolization unnecessary.\n                  <\/jats:p>","DOI":"10.1038\/s41598-026-49706-6","type":"journal-article","created":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T06:44:25Z","timestamp":1777013065000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Hemodynamic effect of coil packing density after tubridge flow diverter for anterior circulation small and medium-sized aneurysms"],"prefix":"10.1038","volume":"16","author":[{"given":"Yeqing","family":"Jiang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ligang","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qimin","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guanghu","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Long","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinzhuo","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaolong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Wan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shengzhang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,24]]},"reference":[{"key":"49706_CR1","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1148\/radiol.13130796","volume":"270","author":"R Kadirvel","year":"2014","unstructured":"Kadirvel, R. et al. Cellular mechanisms of aneurysm occlusion after treatment with a flow diverter. Radiology 270, 394\u2013399 (2014).","journal-title":"Radiology"},{"key":"49706_CR2","doi-asserted-by":"publisher","first-page":"858","DOI":"10.1148\/radiol.13120099","volume":"267","author":"T Becske","year":"2013","unstructured":"Becske, T. et al. Pipeline for uncoilable or failed aneurysms: Results from a multicenter clinical trial. Radiology 267, 858\u2013868 (2013).","journal-title":"Radiology"},{"key":"49706_CR3","doi-asserted-by":"publisher","first-page":"807","DOI":"10.3174\/ajnr.A5619","volume":"39","author":"JM Liu","year":"2018","unstructured":"Liu, J. M. et al. Parent artery reconstruction for large or giant cerebral aneurysms using the tubridge flow diverter: A multicenter, randomized, controlled clinical trial (PARAT). AJNR Am J Neuroradiol 39, 807\u2013816 (2018).","journal-title":"AJNR Am J Neuroradiol"},{"key":"49706_CR4","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1136\/neurintsurg-2019-015091","volume":"12","author":"RA Hanel","year":"2020","unstructured":"Hanel, R. A. et al. Prospective study on embolization of intracranial aneurysms with the pipeline device: The PREMIER study 1 year results. J Neurointerv Surg 12, 62\u201366 (2020).","journal-title":"J Neurointerv Surg"},{"key":"49706_CR5","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1136\/neurintsurg-2021-018361","volume":"15","author":"M Zhang","year":"2023","unstructured":"Zhang, M. et al. How to perform intra-aneurysmal coil embolization after Pipeline deployment: A study from a hemodynamic viewpoint. J Neurointerv Surg 15, 157\u2013162 (2023).","journal-title":"J Neurointerv Surg"},{"key":"49706_CR6","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2021.651465","volume":"12","author":"Q Zhang","year":"2021","unstructured":"Zhang, Q. et al. Safety and efficacy of coils in conjunction with the pipeline flex embolization device for the treatment of cerebral aneurysms. Front Neurol 12, 651465 (2021).","journal-title":"Front Neurol"},{"key":"49706_CR7","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2019.00522","volume":"10","author":"W Li","year":"2019","unstructured":"Li, W. et al. Efficacy of LVIS vs. Enterprise stent for endovascular treatment of medium-sized intracranial aneurysms: A hemodynamic comparison study. Front Neurol 10, 522 (2019).","journal-title":"Front Neurol"},{"key":"49706_CR8","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1136\/neurintsurg-2014-011171","volume":"7","author":"I Larrabide","year":"2015","unstructured":"Larrabide, I. et al. Effect of aneurysm and ICA morphology on hemodynamics before and after flow diverter treatment. J Neurointerv Surg 7, 272\u2013280 (2015).","journal-title":"J Neurointerv Surg"},{"key":"49706_CR9","doi-asserted-by":"publisher","first-page":"1936","DOI":"10.1161\/STROKEAHA.113.001202","volume":"44","author":"Q Huang","year":"2013","unstructured":"Huang, Q. et al. Hemodynamic changes by flow diverters in rabbit aneurysm models: a computational fluid dynamic study based on micro-computed tomography reconstruction. Stroke 44, 1936\u20131941 (2013).","journal-title":"Stroke"},{"key":"49706_CR10","doi-asserted-by":"publisher","first-page":"1567","DOI":"10.3174\/ajnr.A3913","volume":"35","author":"JR Cebral","year":"2014","unstructured":"Cebral, J. R. et al. Analysis of hemodynamics and aneurysm occlusion after flow-diverting treatment in rabbit models. AJNR Am. J. Neuroradiol. 35, 1567\u20131573 (2014).","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"49706_CR11","doi-asserted-by":"crossref","unstructured":"CHUNG B. et al. Hemodynamic analysis of fast and slow aneurysm occlusions by flow diversion in rabbits. J Neurointerv Surg 7, 931\u2013935 (2015).","DOI":"10.1136\/neurintsurg-2014-011412"},{"key":"49706_CR12","doi-asserted-by":"crossref","unstructured":"Paliwal, N. et al. Association between hemodynamic modifications and clinical outcome of intracranial aneurysms treated using flow diverters. Proc SPIE Int. Soc. Opt. Eng 10135 (2017).","DOI":"10.1117\/12.2254584"},{"key":"49706_CR13","doi-asserted-by":"publisher","DOI":"10.3171\/2018.8.FOCUS18332","volume":"45","author":"N Paliwal","year":"2018","unstructured":"Paliwal, N. et al. Outcome prediction of intracranial aneurysm treatment by flow diverters using machine learning. Neurosurg. Focus 45, E7 (2018).","journal-title":"Neurosurg. Focus"},{"key":"49706_CR14","doi-asserted-by":"publisher","first-page":"136","DOI":"10.3174\/ajnr.A3790","volume":"35","author":"W Chong","year":"2014","unstructured":"Chong, W. et al. Computational hemodynamics analysis of intracranial aneurysms treated with flow diverters: correlation with clinical outcomes. AJNR Am. J. Neuroradiol. 35, 136\u2013142 (2014).","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"49706_CR15","doi-asserted-by":"publisher","first-page":"98","DOI":"10.14366\/usg.14063","volume":"34","author":"AC Tsang","year":"2015","unstructured":"Tsang, A. C. et al. Blood flow in intracranial aneurysms treated with Pipeline embolization devices: Computational simulation and verification with Doppler ultrasonography on phantom models. Ultrasonography 34, 98\u2013108 (2015).","journal-title":"Ultrasonography"},{"key":"49706_CR16","doi-asserted-by":"publisher","first-page":"814","DOI":"10.1136\/neurintsurg-2019-015696","volume":"12","author":"NM Cancelliere","year":"2020","unstructured":"Cancelliere, N. M. et al. Comparison of intra-aneurysmal flow modification using optical flow imaging to evaluate the performance of Evolve and Pipeline flow diverting stents. J. Neurointerv. Surg. 12, 814\u2013817 (2020).","journal-title":"J. Neurointerv. Surg."},{"key":"49706_CR17","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1177\/0954411916673674","volume":"231","author":"T Peach","year":"2017","unstructured":"Peach, T., Spranger, K. & Ventikos, Y. Virtual flow-diverter treatment planning: The effect of device placement on bifurcation aneurysm haemodynamics. Proc. Inst. Mech. Eng. H. 231, 432\u2013443 (2017).","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"49706_CR18","doi-asserted-by":"publisher","first-page":"1827","DOI":"10.1007\/s00701-012-1482-2","volume":"154","author":"Z Kulcs\u00e1r","year":"2012","unstructured":"Kulcs\u00e1r, Z. et al. Flow diversion treatment: intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosis. Acta Neurochir. (Wien). 154, 1827\u20131834 (2012).","journal-title":"Acta Neurochir. (Wien)"},{"key":"49706_CR19","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1002\/cnm.2663","volume":"30","author":"TW Peach","year":"2014","unstructured":"Peach, T. W. et al. Personalizing flow-diverter intervention for cerebral aneurysms: from computational hemodynamics to biochemical modeling. Int J Numer Method Biomed Eng 30, 1387\u20131407 (2014).","journal-title":"Int J Numer Method Biomed Eng"},{"key":"49706_CR20","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2021.651465","volume":"12","author":"Q Zhang","year":"2021","unstructured":"Zhang, Q. et al. Safety and efficacy of coils in conjunction with the pipeline flex embolization device for the treatment of cerebral aneurysms. Front Neurol 12, 651465 (2021).","journal-title":"Front Neurol"},{"key":"49706_CR21","doi-asserted-by":"publisher","DOI":"10.1177\/1756286420967828","volume":"13","author":"B Luo","year":"2020","unstructured":"Luo, B. et al. Pipeline Embolization device for intracranial aneurysms in a large Chinese cohort: factors related to aneurysm occlusion. Ther Adv Neurol Disord 13, 1279189396 (2020).","journal-title":"Ther Adv Neurol Disord"},{"key":"49706_CR22","doi-asserted-by":"publisher","first-page":"3332","DOI":"10.1016\/j.jbiomech.2015.06.018","volume":"48","author":"RJ Damiano","year":"2015","unstructured":"Damiano, R. J. et al. Finite element modeling of endovascular coiling and flow diversion enables hemodynamic prediction of complex treatment strategies for intracranial aneurysm. J Biomech 48, 3332\u20133340 (2015).","journal-title":"J Biomech"},{"key":"49706_CR23","doi-asserted-by":"publisher","first-page":"1501","DOI":"10.1161\/STROKEAHA.107.504670","volume":"39","author":"L Elijovich","year":"2008","unstructured":"Elijovich, L. et al. Predictors and outcomes of intraprocedural rupture in patients treated for ruptured intracranial aneurysms: the CARAT study. Stroke 39, 1501\u20131506 (2008).","journal-title":"Stroke"},{"key":"49706_CR24","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1136\/neurintsurg-2017-013156","volume":"10","author":"S Kawabata","year":"2018","unstructured":"Kawabata, S. et al. Risk factors for and outcomes of intraprocedural rupture during endovascular treatment of unruptured intracranial aneurysms. J Neurointerv Surg 10, 362\u2013366 (2018).","journal-title":"J Neurointerv Surg"},{"key":"49706_CR25","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1136\/jnis-2023-020173","volume":"16","author":"C Wang","year":"2024","unstructured":"Wang, C. et al. Pipeline embolization device versus Atlas stent assisted coiling for intracranial aneurysm treatment: a retrospective, propensity score matched study with a focus on midterm outcomes and hospital costs. J Neurointerv Surg 16, 379\u2013384 (2024).","journal-title":"J Neurointerv Surg"},{"key":"49706_CR26","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2020.598412","volume":"11","author":"H Wan","year":"2020","unstructured":"Wan, H. et al. Hemodynamic effect of the last finishing coils in packing the aneurysm neck. Front Neurol 11, 598412 (2020).","journal-title":"Front Neurol"},{"key":"49706_CR27","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1016\/j.jbiomech.2011.12.016","volume":"45","author":"MH Babiker","year":"2012","unstructured":"Babiker, M. H. et al. Influence of stent configuration on cerebral aneurysm fluid dynamics. J. Biomech. 45, 440\u20137 (2012).","journal-title":"J. Biomech."},{"key":"49706_CR28","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2022.927135","volume":"13","author":"Y Jiang","year":"2022","unstructured":"Jiang, Y. et al. Hemodynamic comparison of treatment strategies for intracranial vertebral artery fusiform aneurysms. Front. Neurol. 13, 927135 (2022).","journal-title":"Front. Neurol."},{"key":"49706_CR29","doi-asserted-by":"publisher","DOI":"10.1186\/s12967-018-1573-9","volume":"16","author":"X Leng","year":"2018","unstructured":"Leng, X. et al. Numerical simulation of patient-specific endovascular stenting and coiling for intracranial aneurysm surgical planning. J. Transl. Med. 16, 208 (2018).","journal-title":"J. Transl. Med."},{"key":"49706_CR30","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1161\/STROKEAHA.110.592923","volume":"42","author":"J Xiang","year":"2011","unstructured":"Xiang, J. et al. Hemodynamic-morphologic discriminants for intracranial aneurysm rupture. Stroke 42, 144\u201352 (2011).","journal-title":"Stroke"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-49706-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-49706-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-49706-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T11:03:58Z","timestamp":1781780638000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-49706-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,24]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["49706"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-49706-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,24]]},"assertion":[{"value":"11 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"18892"}}