{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T23:50:14Z","timestamp":1782172214289,"version":"3.54.5"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T00:00:00Z","timestamp":1777248000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T00:00:00Z","timestamp":1782172800000},"content-version":"vor","delay-in-days":57,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100020595","name":"National Science and Technology Council","doi-asserted-by":"publisher","award":["NSTC 113-2221-E-039 -002 -MY3"],"award-info":[{"award-number":["NSTC 113-2221-E-039 -002 -MY3"]}],"id":[{"id":"10.13039\/100020595","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012544","name":"China Medical University, Taiwan","doi-asserted-by":"publisher","award":["CMU113-MF-65"],"award-info":[{"award-number":["CMU113-MF-65"]}],"id":[{"id":"10.13039\/501100012544","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Segmental mandibular reconstruction is challenging. This in-vitro study compared the biomechanics of two 3D-printed porous Ti-6Al-4\u00a0V implants (Quad-diametral-cross, Hex-vase) versus a solid implant using a dual-material 3D-printed mandibular model and strain gauges. A 100\u00a0N static load was applied. Under eccentric loading, the solid implant generated extremely high tensile strain (871.67 \u00b5\u03b5), while porous designs reduced peak strains. The Hex-vase design transmitted the highest compressive strain (-795.85 \u00b5\u03b5), 65% greater in magnitude than the solid, suggesting improved mechanical stimulus transfer to peri-implant bone. The QDC design provided a moderate environment, suitable for compromised bone. Porous implants are biomechanically superior, offering customizable solutions to mitigate stress shielding.<\/jats:p>","DOI":"10.1038\/s41598-026-50741-6","type":"journal-article","created":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T16:37:20Z","timestamp":1777307840000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Biomechanical evaluation of 3D-printed porous lattice versus solid mandibular implants: an in vitro study"],"prefix":"10.1038","volume":"16","author":[{"given":"Hao","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jui-Ting","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lih-Jyh","family":"Fuh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heng-Li","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,27]]},"reference":[{"key":"50741_CR1","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.oraloncology.2009.11.006","volume":"46","author":"M Bak","year":"2010","unstructured":"Bak, M., Jacobson, A. S., Buchbinder, D. & Urken, M. L. Contemporary reconstruction of the mandible. Oral Oncol. 46, 71\u201376 (2010).","journal-title":"Oral Oncol."},{"key":"50741_CR2","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1002\/hed.25452","volume":"41","author":"I Petrovic","year":"2019","unstructured":"Petrovic, I. et al. A systematic review of validated tools assessing functional and aesthetic outcomes following fibula free flap reconstruction of the mandible. Head neck. 41, 248\u2013255 (2019).","journal-title":"Head neck"},{"key":"50741_CR3","doi-asserted-by":"publisher","first-page":"1314","DOI":"10.1097\/00006534-199910000-00011","volume":"104","author":"PG Cordeiro","year":"1999","unstructured":"Cordeiro, P. G., Disa, J. J., Hidalgo, D. A. & Hu, Q. Y. Reconstruction of the mandible with osseous free flaps: a 10-year experience with 150 consecutive patients. Plast. Reconstr. Surg. 104, 1314\u20131320 (1999).","journal-title":"Plast. Reconstr. Surg."},{"key":"50741_CR4","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1001\/archotol.124.1.46","volume":"124","author":"ML Urken","year":"1998","unstructured":"Urken, M. L. et al. Oromandibular reconstruction using microvascular composite flaps: report of 210 cases. Arch. Otolaryngol.\u2013Head Neck Surg. 124, 46\u201355 (1998).","journal-title":"Arch. Otolaryngol.\u2013Head Neck Surg."},{"key":"50741_CR5","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.oraloncology.2017.12.020","volume":"77","author":"K Kakarala","year":"2018","unstructured":"Kakarala, K., Shnayder, Y., Tsue, T. T. & Girod, D. A. Mandibular reconstruction. Oral Oncol. 77, 111\u2013117 (2018).","journal-title":"Oral Oncol."},{"key":"50741_CR6","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1016\/j.joms.2018.10.016","volume":"77","author":"R Di Giuli","year":"2019","unstructured":"Di Giuli, R. et al. Donor-site morbidity after osteocutaneous free fibula transfer: longitudinal analysis of gait performance. J. Oral Maxillofac. Surg. 77, 648\u2013657 (2019).","journal-title":"J. Oral Maxillofac. Surg."},{"key":"50741_CR7","doi-asserted-by":"publisher","first-page":"714","DOI":"10.1097\/PRS.0b013e318221dc2a","volume":"128","author":"AO Momoh","year":"2011","unstructured":"Momoh, A. O. et al. A prospective cohort study of fibula free flap donor-site morbidity in 157 consecutive patients. Plast. Reconstr. Surg. 128, 714\u2013720 (2011).","journal-title":"Plast. Reconstr. Surg."},{"key":"50741_CR8","doi-asserted-by":"publisher","first-page":"2408","DOI":"10.1016\/j.joms.2015.04.019","volume":"73","author":"E Farr\u00e9-Guasch","year":"2015","unstructured":"Farr\u00e9-Guasch, E. et al. Application of additive manufacturing in oral and maxillofacial surgery. J. Oral Maxillofac. Surg. 73, 2408\u20132418 (2015).","journal-title":"J. Oral Maxillofac. Surg."},{"key":"50741_CR9","doi-asserted-by":"publisher","first-page":"1877","DOI":"10.1016\/j.jcms.2014.07.006","volume":"42","author":"AL Jardini","year":"2014","unstructured":"Jardini, A. L. et al. Cranial reconstruction: 3D biomodel and custom-built implant created using additive manufacturing. J. Cranio-Maxillofac. Surg. 42, 1877\u20131884 (2014).","journal-title":"J. Cranio-Maxillofac. Surg."},{"key":"50741_CR10","volume-title":"Introduction to Biomaterials: Basic Theory with Engineering Applications","author":"J Ong","year":"2014","unstructured":"Ong, J., Appleford, M. R. & Mani, G. Introduction to Biomaterials: Basic Theory with Engineering Applications (Cambridge University Press, 2014)."},{"key":"50741_CR11","doi-asserted-by":"publisher","first-page":"487","DOI":"10.3390\/coatings11050487","volume":"11","author":"P Bocchetta","year":"2021","unstructured":"Bocchetta, P. et al. Passive layers and corrosion resistance of biomedical Ti-6Al-4V and \u03b2-Ti alloys. Coatings 11, 487 (2021).","journal-title":"Coatings"},{"key":"50741_CR12","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s13036-021-00255-8","volume":"15","author":"F Deng","year":"2021","unstructured":"Deng, F., Liu, L., Li, Z. & Liu J. 3D printed Ti6Al4V bone scaffolds with different pore structure effects on bone ingrowth. J. Biol. Eng. 15, 4 (2021).","journal-title":"J. Biol. Eng."},{"key":"50741_CR13","doi-asserted-by":"publisher","first-page":"253","DOI":"10.3390\/coatings14030253","volume":"14","author":"S He","year":"2024","unstructured":"He, S. et al. Effect of 3D-printed porous titanium alloy pore structure on bone regeneration: A review. Coatings 14, 253 (2024).","journal-title":"Coatings"},{"key":"50741_CR14","doi-asserted-by":"publisher","first-page":"1700648","DOI":"10.1002\/adem.201700648","volume":"20","author":"K Pa\u0142ka","year":"2018","unstructured":"Pa\u0142ka, K. & Pokrowiecki, R. Porous titanium implants: a review. Adv. Eng. Mater. 20, 1700648 (2018).","journal-title":"Adv. Eng. Mater."},{"key":"50741_CR15","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1186\/s13018-022-03492-9","volume":"18","author":"S Safavi","year":"2023","unstructured":"Safavi, S. et al. Additively manufactured controlled porous orthopedic joint replacement designs to reduce bone stress shielding: a systematic review. J. Orthop. Surg, Res. 18, 42 (2023).","journal-title":"J. Orthop. Surg, Res."},{"key":"50741_CR16","first-page":"111","volume":"10","author":"F Matassi","year":"2013","unstructured":"Matassi, F., Botti, A., Sirleo, L., Carulli, C. & Innocenti, M. Porous metal for orthopedics implants. Clin. Cases Miner. Bone Metab. 10, 111 (2013).","journal-title":"Clin. Cases Miner. Bone Metab."},{"key":"50741_CR17","doi-asserted-by":"publisher","first-page":"3943","DOI":"10.36922\/ijb.3943","volume":"10","author":"H Zhang","year":"2024","unstructured":"Zhang, H., Fuh, L. J., Hsu, J. T., Lim, Z. M. & Huang, H. L. Biomechanical analysis of partial mandibular implants with various lattice designs of different material properties: In vitro study and finite element analysis. Int. J. Bioprinting. 10, 3943 (2024).","journal-title":"Int. J. Bioprinting"},{"key":"50741_CR18","doi-asserted-by":"publisher","first-page":"425","DOI":"10.4103\/0970-9290.70813","volume":"21","author":"A Srirekha","year":"2010","unstructured":"Srirekha, A. & Bashetty, K. Infinite to finite: An overview of finite element analysis. Indian J. Dent. Res. 21, 425\u2013432 (2010).","journal-title":"Indian J. Dent. Res."},{"key":"50741_CR19","doi-asserted-by":"publisher","first-page":"1774","DOI":"10.1002\/jor.23445","volume":"35","author":"S Arabnejad","year":"2017","unstructured":"Arabnejad, S., Johnston, B., Tanzer, M. & Pasini, D. Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty. J. Orthop. Res. 35, 1774\u20131783 (2017).","journal-title":"J. Orthop. Res."},{"key":"50741_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.compstruct.2023.117262","volume":"321","author":"M Shahzamanian","year":"2023","unstructured":"Shahzamanian, M., Banerjee, R., Dahotre, N. B., Srinivasa, A. R. & Reddy, J. Analysis of stress shielding reduction in bone fracture fixation implant using functionally graded materials. Compos. Struct. 321, 117262 (2023).","journal-title":"Compos. Struct."},{"key":"50741_CR21","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2023.1092361","volume":"11","author":"SA Naghavi","year":"2023","unstructured":"Naghavi, S. A. et al. A novel hybrid design and modelling of a customised graded Ti-6Al-4V porous hip implant to reduce stress-shielding: An experimental and numerical analysis. Front. Bioeng. Biotechnol. 11, 1092361 (2023).","journal-title":"Front. Bioeng. Biotechnol."},{"key":"50741_CR22","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijmecsci.2021.106331","volume":"197","author":"L Zhang","year":"2021","unstructured":"Zhang, L., Song, B., Choi, S.-K. & Shi, Y. A topology strategy to reduce stress shielding of additively manufactured porous metallic biomaterials. Int. J. Mech. Sci. 197, 106331 (2021).","journal-title":"Int. J. Mech. Sci."},{"key":"50741_CR23","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1111\/j.1600-0501.2004.01067.x","volume":"16","author":"Y Kim","year":"2005","unstructured":"Kim, Y., Oh, T. J., Misch, C. E. & Wang, H. L. Occlusal considerations in implant therapy: Clinical guidelines with biomechanical rationale. Clin. Oral Implants Res. 16, 26\u201335 (2005).","journal-title":"Clin. Oral Implants Res."},{"key":"50741_CR24","first-page":"473","volume":"20","author":"R Chapman","year":"1989","unstructured":"Chapman, R. Principles of occlusion for implant prostheses: Guidelines for position, timing, and force of occlusal contacts. Quintessence Int. 20, 473\u2013480 (1989).","journal-title":"Quintessence Int."},{"key":"50741_CR25","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1007\/s007740070001","volume":"18","author":"HM Frost","year":"2000","unstructured":"Frost, H. M. The Utah paradigm of skeletal physiology: An overview of its insights for bone, cartilage and collagenous tissue organs. J. Bone Miner. Metab. 18, 305\u2013316 (2000).","journal-title":"J. Bone Miner. Metab."},{"key":"50741_CR26","doi-asserted-by":"publisher","first-page":"612","DOI":"10.3390\/pr10030612","volume":"10","author":"D Savio","year":"2022","unstructured":"Savio, D. & Bagno, A. When the total hip replacement fails: A review on the stress-shielding effect. Processes 10, 612 (2022).","journal-title":"Processes"},{"key":"50741_CR27","first-page":"202","volume":"274","author":"DR Sumner","year":"1992","unstructured":"Sumner, D. R. & Galante, J. O. Determinants of stress shielding: Design versus materials versus interface. Clin. Orthop. Relat. Res. (1976\u20132007) 274, 202\u2013212 (1992).","journal-title":"Clin. Orthop. Relat. Res. (1976\u20132007)"},{"key":"50741_CR28","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-025-03959-9","volume":"15","author":"O Daqiq","year":"2025","unstructured":"Daqiq, O. et al. Finite element analysis of the human mandible: A systematic review with meta-analysis of the essential input parameters. Sci. Rep. 15, 19582 (2025).","journal-title":"Sci. Rep."},{"key":"50741_CR29","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2024.106538","volume":"155","author":"S Lemaire","year":"2024","unstructured":"Lemaire, S., Bouby, C., Thiebaud, F. & Berry-Kromer, V. Prosthetic framework improvement using lattice structure: A comparative finite element study of a mandibular implant-supported prosthesis. J. Mech. Behav. Biomed. Mater. 155, 106538 (2024).","journal-title":"J. Mech. Behav. Biomed. Mater."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-50741-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-50741-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-50741-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T23:39:59Z","timestamp":1782171599000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-50741-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,27]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["50741"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-50741-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,27]]},"assertion":[{"value":"1 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Institutional Review Board of China Medical University Hospital (protocol code: CMUH110-REC2-247).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}],"article-number":"19463"}}