{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,16]],"date-time":"2026-08-16T23:24:41Z","timestamp":1786922681803,"version":"build-2736575974"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T00:00:00Z","timestamp":1779321600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T00:00:00Z","timestamp":1786924800000},"content-version":"vor","delay-in-days":88,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"the Longgang District Science, Technology and Innovation Bureau, ShenzhenProject","award":["LGWJ2023-132"],"award-info":[{"award-number":["LGWJ2023-132"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-50759-w","type":"journal-article","created":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T21:05:40Z","timestamp":1779397540000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Finite element analysis of force-multiplying bridge structure applied in screw internal fixation for distal radius type C fractures"],"prefix":"10.1038","volume":"16","author":[{"given":"Xie","family":"Huo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yixuan","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sun","family":"Ke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,21]]},"reference":[{"issue":"8","key":"50759_CR1","doi-asserted-by":"crossref","first-page":"04020105","DOI":"10.1061\/(ASCE)ST.1943-541X.0002700","volume":"146","author":"Y Chen","year":"2020","unstructured":"Chen, Y. & Liu, J. Mechanical characteristics and engineering applications of BaileyBridge truss structure. J. Struct. Eng. 146 (8), 04020105 (2020).","journal-title":"J. Struct. Eng."},{"key":"50759_CR2","first-page":"102","volume":"64","author":"L Wang","year":"2019","unstructured":"Wang, L., Zhang, H. & Li, M. Biomechanical analysis of stress concentration in eccentric fixation for distal radius fractures. Clin. Biomech. Elsevier Ltd. 64, 102\u2013108 (2019).","journal-title":"Clin. Biomech. Elsevier Ltd"},{"issue":"12","key":"50759_CR3","first-page":"2165","volume":"109","author":"P Zhang","year":"2021","unstructured":"Zhang, P. et al. Load distribution and stress optimization in minimally invasive screw fixation for orthopaedic fractures. J. Biomedical Mater. Res. Part. B: Appl. Biomaterials. 109 (12), 2165\u20132173 (2021).","journal-title":"J. Biomedical Mater. Res. Part. B: Appl. Biomaterials"},{"key":"50759_CR4","first-page":"189","volume":"106","author":"SH Kim","year":"2018","unstructured":"Kim, S. H., Lee, J. E. & Park, J. H. Optimal thin-slice CT scanning parameters for three-dimensional reconstruction of the radius. Eur. J. Radiol. 106, 189\u2013194 (2018).","journal-title":"Eur. J. Radiol."},{"key":"50759_CR5","unstructured":"Materialise, N.V. Mimics 21.0 Official user manual: 3D modeling of bone tissue [Software Manual]. Materialise NV, Leuven, Belgium. (2020)."},{"issue":"Suppl 1","key":"50759_CR6","first-page":"S2","volume":"33","author":"TP R\u00fcedi","year":"2019","unstructured":"R\u00fcedi, T. P., Murphy, D. A. & Jupiter, J. B. The AO\/OTA classification of distal radius fractures: An update. J. Orthop. Trauma. 33 (Suppl 1), S2\u2013S10 (2019).","journal-title":"J. Orthop. Trauma"},{"issue":"5","key":"50759_CR7","doi-asserted-by":"publisher","first-page":"051006","DOI":"10.1115\/1.4068156","volume":"144","author":"S Yang","year":"2022","unstructured":"Yang, S. et al. Friction coefficient determination for screw-bone and screw-screw interfaces in orthopaedic internal fixation. J. Biomech. Eng. 144 (5), 051006 (2022).","journal-title":"J. Biomech. Eng."},{"issue":"6","key":"50759_CR8","first-page":"1623","volume":"51","author":"X Li","year":"2020","unstructured":"Li, X., Wang, Q. & Zhao, Y. Biomechanical properties of frictional contact at fracture surfaces of distal radius fractures. Injury 51 (6), 1623\u20131629 (2020).","journal-title":"Injury"},{"key":"50759_CR9","unstructured":"ANSYS Inc. ANSYS 17.0 User Guide: Tetrahedral Mesh Generation for Solid Models [Software Manual]. ANSYS Inc., Canonsburg, PA, USA. (2017)."},{"key":"50759_CR10","unstructured":"Hinton, E., & Owen, D. R. Finite Element Mesh Convergence Analysis: Principles and Practice. (CRC Press, Boca Raton, FL, 2017)."},{"key":"50759_CR11","unstructured":"Zienkiewicz, O. C., Taylor, R. L., & Zhu, J. Z. The finite element method: Its basis and fundamentals (7th ed.). Butterworth-Heinemann, Oxford, UK. (2013)."},{"key":"50759_CR12","unstructured":"Gibson, L. J., & Ashby, M. F. Cellular Solids: Structure and Properties. (2nd ed.). (Cambridge University Press, 2010)."},{"issue":"15","key":"50759_CR13","first-page":"3268","volume":"49","author":"RA Brand","year":"2016","unstructured":"Brand, R. A. & Crowninshield, R. D. Physiological loading conditions of the human wrist during daily activities. J. Biomech. 49 (15), 3268\u20133274 (2016).","journal-title":"J. Biomech."},{"issue":"8","key":"50759_CR14","first-page":"987","volume":"21","author":"KW Ng","year":"2018","unstructured":"Ng, K. W. & Yang, J. Finite element modeling of distal radius fractures: Boundary condition setting for proximal radius fixation. Comput. Biomech. Biomedical Eng. 21 (8), 987\u2013995 (2018).","journal-title":"Comput. Biomech. Biomedical Eng."},{"key":"50759_CR15","unstructured":"Bathe, K. J. Finite element procedures (2nd ed.). Prentice-Hall, Upper Saddle River, NJ. (2014)."},{"key":"50759_CR16","first-page":"45","volume":"98","author":"X Zhang","year":"2022","unstructured":"Zhang, X., Liu, Y. & Zhao, J. Standardized finite element modeling method for distal radius fractures. Med. Eng. Phys. 98, 45\u201352 (2022).","journal-title":"Med. Eng. Phys."},{"issue":"11","key":"50759_CR17","first-page":"3012","volume":"51","author":"J Prasil","year":"2020","unstructured":"Prasil, J., Nov\u00e1k, M. & Svoboda, M. Torsional performance of locked plate fixation for distal radius fractures: Effect of screw arrangement. Injury 51 (11), 3012\u20133018 (2020).","journal-title":"Injury"},{"key":"50759_CR18","unstructured":"Koval, K. J., & Zuckerman, J. D. Load concentration mechanism of locked plate fixation in fracture treatment. J. Orthopaedic Trauma, 31 (7), 389\u2013393. (2017)."},{"key":"50759_CR19","unstructured":"Smith, A. J., & Jones, T. R. Truss structure-based load sharing in minimally invasive orthopaedic internal fixation. J. Biomed. Mater. Res. Part A 107 (8), 1567\u20131575. (2019)."},{"key":"50759_CR20","unstructured":"British Standards Institution (BSI). BS EN 1993-1-1:2021 Eurocode 3: Design of steel structures - General rules and rules for buildings [Standard]. BSI, London, UK. (2021)."},{"key":"50759_CR21","unstructured":"Cook, S. D., & Thomas, K. A. Stress concentration at the screw-bone interface: A primary cause of fixation loosening in fracture treatment. Clin. Orthopaedics Relat. Res. 476 (11), 2643\u20132651. (2018)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-50759-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-50759-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-50759-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,16]],"date-time":"2026-08-16T22:32:35Z","timestamp":1786919555000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-50759-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,21]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["50759"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-50759-w","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-8612025\/v1","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,21]]},"assertion":[{"value":"15 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study (Research Title: Finite Element Analysis of Force-Multiplying Bridge Structure Applied in Screw Internal Fixation for Distal Radius Type C Fractures) is a finite element numerical analysis study in orthopedics, aiming to explore issues related to the optimization of fracture fixation schemes through biomechanical modeling methods. Throughout the study, we have strictly adhered to the \u201cDeclaration of Helsinki of the World Medical Assembly\u201d, the \u201cInternational Ethical Guidelines for Biomedical Research Involving Human Subjects\u201d, and relevant regulations on medical research ethics in China, and abided by the principles of research integrity and protection of participants\u2019 rights and interests. If the study is based on human imaging data (CT thin-slice scan data): The study protocol has been reviewed and approved by the Medical Ethics Committee of the Fourth People\u2019s Hospital of Longgang District, Shenzhen. The approval number is 202307, and the approval date is October 15, 2023. The study design, data collection and processing procedures are all in line with the requirements of the Ethics Committee. If the study involves secondary use of data (such as reuse of previous clinical imaging data), additional special approval from the Ethics Committee for data reuse has been obtained.","order":2,"name":"Ethics","label":"Ethical review and approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The volunteer has obtained a comprehensive understanding of the study details, signed the informed consent form, voluntarily participated in the experiment, and consented to the publication of the research findings.","order":3,"name":"Ethics","label":"Informed consent","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"25534"}}