{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T22:26:05Z","timestamp":1783463165958,"version":"3.55.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T00:00:00Z","timestamp":1778112000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T00:00:00Z","timestamp":1783468800000},"content-version":"vor","delay-in-days":62,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100019912","name":"ELSO","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100019912","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Capnometry is a cost-efficient method of monitoring carbon dioxide (CO\n                    <jats:sub>2<\/jats:sub>\n                    ) in healthcare settings, especially during mechanical ventilation and cardiopulmonary bypass. However, the utility of capnometers for studying CO\n                    <jats:sub>2<\/jats:sub>\n                    elimination in a longer-duration, clinical extracorporeal membrane oxygenation (ECMO) has been poorly characterized. This report presents data from 10 venovenous ECMO patients at Vanderbilt University Medical Center between April and June 2021. Exhaust CO\n                    <jats:sub>2<\/jats:sub>\n                    was intermittently measured from a membrane oxygenator\u2019s gas outlet, and arterial blood samples were simultaneously drawn from the patient. Clinical variables including ECMO and ventilator management, patient demographics, and outcomes were recorded. Exhaust CO\n                    <jats:sub>2<\/jats:sub>\n                    and other study variables were recorded at 233 discrete time points from the 10 patients. The median duration of ECMO support was 9\u00a0days. Sweep gas flow rate demonstrated a strong, negative correlation with exhaust CO\n                    <jats:sub>2<\/jats:sub>\n                    concentration, from both univariate and multivariate regression analyses (adjusted \u03b2\u2009=\u2009\u2212\u20095.556 for sweep\u2009&lt;\u20094\u00a0L\/min,\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.001). Blood flow, oxygenator duration of use, and arterial CO\n                    <jats:sub>2<\/jats:sub>\n                    demonstrated weaker relationships with exhaust CO\n                    <jats:sub>2<\/jats:sub>\n                    (adjusted \u03b2\u2009=\u20092.341, \u2212\u20090.258, 0.175, respectively), which agrees with the clinical understanding about CO\n                    <jats:sub>2<\/jats:sub>\n                    management during ECMO. This descriptive study provides foundation for future research to precisely define the clinical role of ECMO exhaust capnometry in the management of the sweep gas flow and the overall therapy.\n                  <\/jats:p>","DOI":"10.1038\/s41598-026-51104-x","type":"journal-article","created":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T10:25:10Z","timestamp":1778149510000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Clinical characterization of membrane oxygenator exhaust capnometry during venovenous extracorporeal membrane oxygenation"],"prefix":"10.1038","volume":"16","author":[{"given":"John W.","family":"Stokes","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Whitney D.","family":"Gannon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Simonds","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ioannis A.","family":"Ziogas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W. Kelly","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yatrik J.","family":"Patel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sean A.","family":"Francois","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caitlin T.","family":"Demarest","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"Bacchetta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rei","family":"Ukita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,7]]},"reference":[{"issue":"14","key":"51104_CR1","doi-asserted-by":"publisher","first-page":"1711","DOI":"10.2169\/internalmedicine.3320-19","volume":"59","author":"T Jo","year":"2020","unstructured":"Jo, T. et al. Usefulness of measurement of end-tidal CO2 using a portable capnometer in patients with chronic respiratory failure receiving long-term oxygen therapy. Intern. Med. 59(14), 1711\u20131720 (2020).","journal-title":"Intern. Med."},{"issue":"2","key":"51104_CR2","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1378\/chest.15-1369","volume":"149","author":"BS Nassar","year":"2016","unstructured":"Nassar, B. S. & Schmidt, G. A. Capnography during critical illness. Chest 149(2), 576\u2013585 (2016).","journal-title":"Chest"},{"issue":"4","key":"51104_CR3","doi-asserted-by":"publisher","first-page":"332","DOI":"10.4103\/0974-2700.142778","volume":"7","author":"BS Kodali","year":"2014","unstructured":"Kodali, B. S. & Urman, R. D. Capnography during cardiopulmonary resuscitation: Current evidence and future directions. J. Emerg. Trauma Shock. 7(4), 332\u2013340 (2014).","journal-title":"J. Emerg. Trauma Shock."},{"issue":"1","key":"51104_CR4","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1186\/s13054-018-2121-y","volume":"22","author":"C Newell","year":"2018","unstructured":"Newell, C., Grier, S. & Soar, J. Airway and ventilation management during cardiopulmonary resuscitation and after successful resuscitation. Crit. Care. 22(1), 190 (2018).","journal-title":"Crit. Care."},{"issue":"3","key":"51104_CR5","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1177\/0310057X9101900320","volume":"19","author":"DA Pybus","year":"1991","unstructured":"Pybus, D. A., Lyon, M., Hamilton, J. & Henderson, M. Measuring the efficiency of an artificial lung: 1. Carbon dioxide transfer. Anaesth. Intensive Care 19(3), 421\u2013425 (1991).","journal-title":"Anaesth. Intensive Care"},{"issue":"1","key":"51104_CR6","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/S0022-5223(19)40929-X","volume":"76","author":"JM Nelems","year":"1978","unstructured":"Nelems, J. M. et al. Extracorporeal membrane oxygenator support for human lung transplantation. J. Thorac. Cardiovasc. Surg. 76(1), 28\u201332 (1978).","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"7","key":"51104_CR7","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1177\/0267659119833233","volume":"34","author":"A Montalti","year":"2019","unstructured":"Montalti, A. et al. Continuous monitoring of membrane lung carbon dioxide removal during ECMO: Experimental testing of a new volumetric capnometer. Perfusion 34(7), 538\u2013543 (2019).","journal-title":"Perfusion"},{"issue":"4","key":"51104_CR8","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1177\/0267659117736379","volume":"33","author":"L Sun","year":"2018","unstructured":"Sun, L. et al. CO2 clearance by membrane lungs. Perfusion 33(4), 249\u2013253 (2018).","journal-title":"Perfusion"},{"issue":"Suppl 5","key":"51104_CR9","doi-asserted-by":"publisher","first-page":"S596","DOI":"10.21037\/jtd.2017.10.05","volume":"10","author":"F Epis","year":"2018","unstructured":"Epis, F. & Belliato, M. Oxygenator performance and artificial-native lung interaction. J. Thorac. Dis. 10(Suppl 5), S596\u2013S605 (2018).","journal-title":"J. Thorac. Dis."},{"issue":"2","key":"51104_CR10","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1111\/aor.13343","volume":"43","author":"A Kaesler","year":"2019","unstructured":"Kaesler, A. et al. Technical indicators to evaluate the degree of large clot formation inside the membrane fiber bundle of an oxygenator in an in vitro setup. Artif. Organs 43(2), 159\u2013166 (2019).","journal-title":"Artif. Organs"},{"issue":"5","key":"51104_CR11","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1177\/0267659119896531","volume":"35","author":"NA Barrett","year":"2020","unstructured":"Barrett, N. A., Hart, N. & Camporota, L. In vivo carbon dioxide clearance of a low-flow extracorporeal carbon dioxide removal circuit in patients with acute exacerbations of chronic obstructive pulmonary disease. Perfusion 35(5), 436\u2013441 (2020).","journal-title":"Perfusion"},{"issue":"2","key":"51104_CR12","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1051\/ject\/200537192","volume":"37","author":"A Baraka","year":"2005","unstructured":"Baraka, A. et al. Oxygenator exhaust capnography for prediction of arterial carbon dioxide tension during hypothermic cardiopulmonary bypass. J. Extra Corpor. Technol. 37(2), 192\u2013195 (2005).","journal-title":"J. Extra Corpor. Technol."},{"issue":"5","key":"51104_CR13","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1111\/aor.13618","volume":"44","author":"RG Conway","year":"2020","unstructured":"Conway, R. G. et al. Evaluation of an autoregulatory ECMO system for total respiratory support in an acute ovine model. Artif. Organs 44(5), 478\u2013487 (2020).","journal-title":"Artif. Organs"},{"key":"51104_CR14","unstructured":"Medical S. The Quantum Ventilation System, accessed 9 June 2025; https:\/\/www.spectrummedical.com\/en-us\/quantum-perfusion-technologies\/quantum-perfusion-modules-us\/quantum-ventilation-system-or-us. (2025)."},{"issue":"1","key":"51104_CR15","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1186\/s13054-020-03388-2","volume":"24","author":"B Zakhary","year":"2020","unstructured":"Zakhary, B. et al. How I approach membrane lung dysfunction in patients receiving ECMO. Crit. Care 24(1), 671 (2020).","journal-title":"Crit. Care"},{"issue":"1_suppl","key":"51104_CR16","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1177\/0267659120906767","volume":"35","author":"B Zakhary","year":"2020","unstructured":"Zakhary, B., Sheldrake, J. & Pellegrino, V. Extracorporeal membrane oxygenation and V\/Q ratios: An ex vivo analysis of CO2 clearance within the Maquet Quadrox-iD oxygenator. Perfusion 35(1_suppl), 29\u201333 (2020).","journal-title":"Perfusion"},{"issue":"12","key":"51104_CR17","doi-asserted-by":"publisher","first-page":"1870","DOI":"10.1007\/s00134-014-3489-z","volume":"40","author":"K Lehle","year":"2014","unstructured":"Lehle, K. et al. Efficiency of gas transfer in venovenous extracorporeal membrane oxygenation: Analysis of 317 cases with four different ECMO systems. Intensive Care Med. 40(12), 1870\u20131877 (2014).","journal-title":"Intensive Care Med."},{"key":"51104_CR18","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.2000.06465.x","author":"MS Hout","year":"2000","unstructured":"Hout, M. S., Hattler, B. G. & Federspiel, W. J. Validation of a model for flow\u2010dependent carbon dioxide exchange in artificial lungs. Artif. Organs https:\/\/doi.org\/10.1046\/j.1525-1594.2000.06465.x (2000).","journal-title":"Artif. Organs"},{"key":"51104_CR19","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.1996.tb04593.x","author":"WJ Federspiel","year":"1996","unstructured":"Federspiel, W. J. & Hattler, B. G. Sweep gas flowrate and CO2 exchange in artificial lungs. Artif. Organs https:\/\/doi.org\/10.1111\/j.1525-1594.1996.tb04593.x (1996).","journal-title":"Artif. Organs"},{"issue":"4","key":"51104_CR20","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1177\/0885066616641383","volume":"32","author":"RH Bartlett","year":"2017","unstructured":"Bartlett, R. H. Physiology of gas exchange during ECMO for respiratory failure. J. Intensive Care Med. 32(4), 243\u2013248 (2017).","journal-title":"J. Intensive Care Med."},{"issue":"5","key":"51104_CR21","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1007\/s00134-012-2785-8","volume":"39","author":"M Schmidt","year":"2013","unstructured":"Schmidt, M. et al. Blood oxygenation and decarboxylation determinants during venovenous ECMO for respiratory failure in adults. Intensive Care Med. 39(5), 838\u2013846 (2013).","journal-title":"Intensive Care Med."},{"issue":"1","key":"51104_CR22","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1186\/s40635-019-0244-3","volume":"7","author":"S Strassmann","year":"2019","unstructured":"Strassmann, S. et al. Impact of sweep gas flow on extracorporeal CO2 removal (ECCO2R). Intensive Care Med. Exp. 7(1), 17 (2019).","journal-title":"Intensive Care Med. Exp."},{"issue":"4","key":"51104_CR23","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1177\/0310057X0503300406","volume":"33","author":"JM Graham","year":"2005","unstructured":"Graham, J. M., Gibbs, N. M., Weightman, W. M. & Sheminant, M. R. The relationship between oxygenator exhaust P(CO2) and arterial P(CO2) during hypothermic cardiopulmonary bypass. Anaesth. Intensive Care 33(4), 457\u2013461 (2005).","journal-title":"Anaesth. Intensive Care"},{"key":"51104_CR24","doi-asserted-by":"publisher","DOI":"10.3390\/s20133613","author":"M Bellancini","year":"2020","unstructured":"Bellancini, M., Cercenelli, L., Severi, S., Comai, G. & Marcelli, E. Development of a CO2 sensor for extracorporeal life support applications. Sensors https:\/\/doi.org\/10.3390\/s20133613 (2020).","journal-title":"Sensors"},{"issue":"21","key":"51104_CR25","doi-asserted-by":"publisher","first-page":"1965","DOI":"10.1056\/NEJMoa1800385","volume":"378","author":"A Combes","year":"2018","unstructured":"Combes, A. et al. Extracorporeal membrane oxygenation for severe acute respiratory distress syndrome. N Engl J Med. 378(21), 1965\u20131975 (2018).","journal-title":"N Engl J Med."},{"issue":"10","key":"51104_CR26","doi-asserted-by":"publisher","first-page":"1296","DOI":"10.1111\/aas.12564","volume":"59","author":"E De Waele","year":"2015","unstructured":"De Waele, E. et al. Measuring resting energy expenditure during extracorporeal membrane oxygenation: preliminary clinical experience with a proposed theoretical model. Acta Anaesthesiol. Scand. 59(10), 1296\u20131302 (2015).","journal-title":"Acta Anaesthesiol. Scand."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-51104-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-51104-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-51104-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T22:11:51Z","timestamp":1783462311000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-51104-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,7]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["51104"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-51104-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,7]]},"assertion":[{"value":"9 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"21017"}}