{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T11:09:09Z","timestamp":1784286549163,"version":"3.55.0"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T00:00:00Z","timestamp":1779062400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T00:00:00Z","timestamp":1784246400000},"content-version":"vor","delay-in-days":60,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100018542","name":"Natural Science Foundation of Sichuan Province","doi-asserted-by":"publisher","award":["2025ZNSFSC1786"],"award-info":[{"award-number":["2025ZNSFSC1786"]}],"id":[{"id":"10.13039\/501100018542","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-51154-1","type":"journal-article","created":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T09:43:04Z","timestamp":1779097384000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Biomechanical comparison of two-screw and four-screw zero-profile fusion devices in anterior cervical discectomy and fusion using finite element analysis"],"prefix":"10.1038","volume":"16","author":[{"given":"Xingjin","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minghe","family":"Yao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chengyi","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tingkui","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kangkang","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hao","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beiyu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,18]]},"reference":[{"key":"51154_CR1","doi-asserted-by":"publisher","first-page":"1342","DOI":"10.1016\/j.spinee.2024.02.016","volume":"24","author":"M Singh","year":"2024","unstructured":"Singh, M. et al. Anterior cervical discectomy and fusion versus cervical disc arthroplasty: An epidemiological review of 433,660 surgical patients from 2011 to 2021. Spine J. 24, 1342\u20131351. https:\/\/doi.org\/10.1016\/j.spinee.2024.02.016 (2024).","journal-title":"Spine J."},{"key":"51154_CR2","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-015-0546-x","volume":"16","author":"E Chong","year":"2015","unstructured":"Chong, E., Pelletier, M. H., Mobbs, R. J. & Walsh, W. R. The design evolution of interbody cages in anterior cervical discectomy and fusion: A systematic review. BMC Musculoskelet. Disord. 16, 99. https:\/\/doi.org\/10.1186\/s12891-015-0546-x (2015).","journal-title":"BMC Musculoskelet. Disord."},{"key":"51154_CR3","doi-asserted-by":"publisher","first-page":"666","DOI":"10.1007\/s11999-010-1597-9","volume":"469","author":"M Scholz","year":"2011","unstructured":"Scholz, M., Schnake, K. J., Pingel, A., Hoffmann, R. & Kandziora, F. A new zero-profile implant for stand-alone anterior cervical interbody fusion. Clin. Orthop. Relat. Res. 469, 666\u2013673. https:\/\/doi.org\/10.1007\/s11999-010-1597-9 (2011).","journal-title":"Clin. Orthop. Relat. Res."},{"key":"51154_CR4","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-022-03400-1","volume":"17","author":"Z Liu","year":"2022","unstructured":"Liu, Z. et al. Changes in cervical alignment of Zero-profile device versus conventional cage-plate construct after anterior cervical discectomy and fusion: A meta-analysis. J. Orthop. Surg. Res. 17, 510. https:\/\/doi.org\/10.1186\/s13018-022-03400-1 (2022).","journal-title":"J. Orthop. Surg. Res."},{"key":"51154_CR5","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-022-02940-w","volume":"17","author":"T Zhang","year":"2022","unstructured":"Zhang, T. et al. Comparison of outcomes between Zero-p implant and anterior cervical plate interbody fusion systems for anterior cervical decompression and fusion: A systematic review and meta-analysis of randomized controlled trials. J. Orthop. Surg. Res. 17, 47. https:\/\/doi.org\/10.1186\/s13018-022-02940-w (2022).","journal-title":"J. Orthop. Surg. Res."},{"key":"51154_CR6","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-024-04729-5","volume":"19","author":"P Zhang","year":"2024","unstructured":"Zhang, P., Zheng, H., Luo, J. & Xu, J. Comparative efficacy of Zero-profile implant and conventional cage-plate implant in the treatment of single-level degenerative cervical spondylosis: A systematic review and meta-analysis. J. Orthop. Surg. Res. 19, 364. https:\/\/doi.org\/10.1186\/s13018-024-04729-5 (2024).","journal-title":"J. Orthop. Surg. Res."},{"key":"51154_CR7","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-023-04134-4","volume":"18","author":"Y Zhang","year":"2023","unstructured":"Zhang, Y., Ju, J. & Wu, J. Zero-profile anchored spacer versus conventional plate-cage construct in bilevel anterior cervical discectomy and fusion: A systematic review and meta-analysis. J. Orthop. Surg. Res. 18, 644. https:\/\/doi.org\/10.1186\/s13018-023-04134-4 (2023).","journal-title":"J. Orthop. Surg. Res."},{"key":"51154_CR8","doi-asserted-by":"publisher","first-page":"2355","DOI":"10.1111\/os.14139","volume":"16","author":"Z Peng","year":"2024","unstructured":"Peng, Z. et al. Does screw number of Zero-profile implants in fusion segment influence intervertebral stability?. Orthop. Surg. 16, 2355\u20132363. https:\/\/doi.org\/10.1111\/os.14139 (2024).","journal-title":"Orthop. Surg."},{"key":"51154_CR9","doi-asserted-by":"publisher","first-page":"E375","DOI":"10.1097\/brs.0000000000000768","volume":"40","author":"M Scholz","year":"2015","unstructured":"Scholz, M., Schleicher, P., Pabst, S. & Kandziora, F. A zero-profile anchored spacer in multilevel cervical anterior interbody fusion: Biomechanical comparison to established fixation techniques. Spine (Phila Pa 1976) 40, E375-380. https:\/\/doi.org\/10.1097\/brs.0000000000000768 (2015).","journal-title":"Spine (Phila Pa 1976)"},{"key":"51154_CR10","doi-asserted-by":"publisher","first-page":"762","DOI":"10.1111\/os.14322","volume":"17","author":"XJ Wang","year":"2025","unstructured":"Wang, X. J. et al. The influence of Zero-profile implant selection on the outcomes of anterior cervical discectomy and fusion. Orthop. Surg. 17, 762\u2013772. https:\/\/doi.org\/10.1111\/os.14322 (2025).","journal-title":"Orthop. Surg."},{"key":"51154_CR11","doi-asserted-by":"publisher","DOI":"10.1097\/brs.0000000000005334","author":"CY Huang","year":"2025","unstructured":"Huang, C. Y. et al. Comparison of two-screw versus four-screw internal fixation on fusion speed in anterior cervical discectomy and fusion: A prospective randomized controlled trial. Spine (Phila Pa 1976) https:\/\/doi.org\/10.1097\/brs.0000000000005334 (2025).","journal-title":"Spine (Phila Pa 1976)"},{"key":"51154_CR12","doi-asserted-by":"publisher","first-page":"E1069","DOI":"10.1097\/BRS.0000000000002644","volume":"43","author":"JM Peterson","year":"2018","unstructured":"Peterson, J. M. et al. Stiffness matters: Part II-The effects of plate stiffness on load-sharing and the progression of fusion following anterior cervical discectomy and fusion in vivo. Spine (Phila Pa 1976) 43, E1069\u2013E1076. https:\/\/doi.org\/10.1097\/BRS.0000000000002644 (2018).","journal-title":"Spine (Phila Pa 1976)"},{"key":"51154_CR13","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-024-04539-9","volume":"19","author":"HH Zhao","year":"2024","unstructured":"Zhao, H. H., Xu, H. W., Wang, S. J., Hu, T. & Wu, D. S. Anterior cervical discectomy and fusion with a Zero-profile VA spacer device: A clinical and radiological study with two-year follow-up. J. Orthop. Surg. Res. 19, 51. https:\/\/doi.org\/10.1186\/s13018-024-04539-9 (2024).","journal-title":"J. Orthop. Surg. Res."},{"key":"51154_CR14","doi-asserted-by":"publisher","first-page":"1926","DOI":"10.1016\/j.spinee.2017.07.009","volume":"17","author":"X Rong","year":"2017","unstructured":"Rong, X. et al. The biomechanical impact of facet tropism on the intervertebral disc and facet joints in the cervical spine. Spine J. 17, 1926\u20131931. https:\/\/doi.org\/10.1016\/j.spinee.2017.07.009 (2017).","journal-title":"Spine J."},{"key":"51154_CR15","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.1016\/j.spinee.2019.02.004","volume":"19","author":"TK Wu","year":"2019","unstructured":"Wu, T. K. et al. Biomechanical effects on the intermediate segment of noncontiguous hybrid surgery with cervical disc arthroplasty and anterior cervical discectomy and fusion: A finite element analysis. Spine J. 19, 1254\u20131263. https:\/\/doi.org\/10.1016\/j.spinee.2019.02.004 (2019).","journal-title":"Spine J."},{"key":"51154_CR16","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2022.842382","volume":"10","author":"YW Shen","year":"2022","unstructured":"Shen, Y. W. et al. Biomechanical evaluation of intervertebral fusion process after anterior cervical discectomy and fusion: A finite element study. Front. Bioeng. Biotechnol. 10, 842382. https:\/\/doi.org\/10.3389\/fbioe.2022.842382 (2022).","journal-title":"Front. Bioeng. Biotechnol."},{"key":"51154_CR17","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1016\/j.jbiomech.2004.07.039","volume":"39","author":"G Denozi\u00e8re","year":"2006","unstructured":"Denozi\u00e8re, G. & Ku, D. N. Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral disc. J. Biomech. 39, 766\u2013775. https:\/\/doi.org\/10.1016\/j.jbiomech.2004.07.039 (2006).","journal-title":"J. Biomech."},{"key":"51154_CR18","doi-asserted-by":"publisher","first-page":"1172","DOI":"10.1111\/os.14374","volume":"17","author":"CY Huang","year":"2025","unstructured":"Huang, C. Y. et al. Biomechanical effects of Zero-P height on anterior cervical discectomy and fusion: A finite element study. Orthop. Surg. 17, 1172\u20131180. https:\/\/doi.org\/10.1111\/os.14374 (2025).","journal-title":"Orthop. Surg."},{"key":"51154_CR19","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1097\/00007632-200201010-00011","volume":"27","author":"T Miura","year":"2002","unstructured":"Miura, T., Panjabi, M. M. & Cripton, P. A. A method to simulate in vivo cervical spine kinematics using in vitro compressive preload. Spine 27, 43\u201348 (2002).","journal-title":"Spine"},{"key":"51154_CR20","doi-asserted-by":"publisher","first-page":"2692","DOI":"10.1097\/00007632-200112150-00012","volume":"26","author":"MM Panjabi","year":"2001","unstructured":"Panjabi, M. M. et al. Mechanical properties of the human cervical spine as shown by three-dimensional load-displacement curves. Spine (Phila Pa 1976) 26, 2692\u20132700. https:\/\/doi.org\/10.1097\/00007632-200112150-00012 (2001).","journal-title":"Spine (Phila Pa 1976)"},{"key":"51154_CR21","doi-asserted-by":"publisher","first-page":"E893","DOI":"10.1097\/BRS.0000000000001468","volume":"41","author":"JH Lee","year":"2016","unstructured":"Lee, J. H., Park, W. M., Kim, Y. H. & Jahng, T. A. A biomechanical analysis of an artificial disc with a shock-absorbing core property by using whole-cervical spine finite element analysis. Spine (Phila Pa 1976) 41, E893\u2013E901. https:\/\/doi.org\/10.1097\/BRS.0000000000001468 (2016).","journal-title":"Spine (Phila Pa 1976)"},{"key":"51154_CR22","unstructured":"Zahaf, S. et al. Biomechanical comparison of three total artificial discs: SB-CHARITE III \u00ae , PRODISC-L \u00ae AND MAVERICK \u00ae REINFORCED by a posterior fixation system in the spinal column: A three-dimensional finite element analysis Biomehani\u010dko Pore\u0111enje tri Ve\u0161ta\u010dka Diska: SB-CHARITE III \u00ae , PRODISC-L \u00ae I MAVERICK \u00ae OJA\u010cANI Stra\u017enjim Fiksacionim Sistemom u Ki\u010dmenom Stubu: Trodimenzionalna Analiza Metodom Kona\u010dnih Elemenata. 21, 65\u201383 (2021)."},{"key":"51154_CR23","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1016\/j.spinee.2006.10.024","volume":"7","author":"D Mourning","year":"2007","unstructured":"Mourning, D., Reitman, C. A., Heggeness, M. H., Esses, S. I. & Hipp, J. A. Initial intervertebral stability after anterior cervical discectomy and fusion with plating. Spine J. 7, 643\u2013646. https:\/\/doi.org\/10.1016\/j.spinee.2006.10.024 (2007).","journal-title":"Spine J."},{"issue":"Suppl 1","key":"51154_CR24","doi-asserted-by":"publisher","first-page":"S41","DOI":"10.1007\/s00590-013-1244-8","volume":"23","author":"H Li","year":"2013","unstructured":"Li, H., Min, J., Zhang, Q., Yuan, Y. & Wang, D. Dynamic cervical plate versus static cervical plate in the anterior cervical discectomy and fusion: A systematic review. Eur J Orthop Surg Traumatol. 23(Suppl 1), S41-46. https:\/\/doi.org\/10.1007\/s00590-013-1244-8 (2013).","journal-title":"Eur J Orthop Surg Traumatol."},{"issue":"Suppl 3","key":"51154_CR25","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1227\/NEU.0000000000000351","volume":"10","author":"MT Reis","year":"2014","unstructured":"Reis, M. T., Reyes, P. M. & Crawford, N. R. Biomechanical assessment of anchored cervical interbody cages: Comparison of 2-screw and 4-screw designs. Neurosurgery 10(Suppl 3), 412\u2013417. https:\/\/doi.org\/10.1227\/NEU.0000000000000351 (2014).","journal-title":"Neurosurgery"},{"key":"51154_CR26","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-90142-5","volume":"11","author":"N Kohli","year":"2021","unstructured":"Kohli, N., Stoddart, J. C. & van Arkel, R. J. The limit of tolerable micromotion for implant osseointegration: A systematic review. Sci Rep. 11, 10797. https:\/\/doi.org\/10.1038\/s41598-021-90142-5 (2021).","journal-title":"Sci Rep."},{"key":"51154_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2020.103760","volume":"120","author":"W Hua","year":"2020","unstructured":"Hua, W. et al. Adjacent segment biomechanical changes after one- or two-level anterior cervical discectomy and fusion using either a zero-profile device or cage plus plate: A finite element analysis. Comput Biol Med. 120, 103760. https:\/\/doi.org\/10.1016\/j.compbiomed.2020.103760 (2020).","journal-title":"Comput Biol Med."},{"key":"51154_CR28","doi-asserted-by":"publisher","first-page":"901","DOI":"10.1111\/vsu.12536","volume":"45","author":"EJ Morrison","year":"2016","unstructured":"Morrison, E. J., Litsky, A. S., Allen, M. J., Fosgate, G. T. & Hettlich, B. F. Evaluation of three human cervical fusion implants for use in the canine cervical vertebral column. Vet. Surg. 45, 901\u2013908. https:\/\/doi.org\/10.1111\/vsu.12536 (2016).","journal-title":"Vet. Surg."},{"key":"51154_CR29","doi-asserted-by":"publisher","first-page":"1752","DOI":"10.1016\/j.spinee.2020.07.002","volume":"20","author":"NJ Lee","year":"2020","unstructured":"Lee, N. J. et al. Does screw length for primary two-level ACDF influence pseudarthrosis risk?. Spine J. 20, 1752\u20131760. https:\/\/doi.org\/10.1016\/j.spinee.2020.07.002 (2020).","journal-title":"Spine J."},{"key":"51154_CR30","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-43086-x","volume":"13","author":"CH Ahn","year":"2023","unstructured":"Ahn, C. H. et al. Comparing zero-profile and conventional cage and plate in anterior cervical discectomy and fusion using finite-element modeling. Sci. Rep. 13, 15766. https:\/\/doi.org\/10.1038\/s41598-023-43086-x (2023).","journal-title":"Sci. Rep."},{"key":"51154_CR31","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1007\/s00586-012-2446-1","volume":"22","author":"B Wojewnik","year":"2013","unstructured":"Wojewnik, B. et al. Biomechanical evaluation of a low profile, anchored cervical interbody spacer device in the setting of progressive flexion-distraction injury of the cervical spine. Eur. Spine J. 22, 135\u2013141. https:\/\/doi.org\/10.1007\/s00586-012-2446-1 (2013).","journal-title":"Eur. Spine J."},{"key":"51154_CR32","doi-asserted-by":"publisher","first-page":"574","DOI":"10.3340\/jkns.2018.0090","volume":"61","author":"TH Kim","year":"2018","unstructured":"Kim, T. H. et al. Can the Zero-Profile Implant be used for anterior cervical discectomy and fusion in traumatic subaxial disc injury? A preliminary, retrospective study. J. Korean Neurosurg. Soc. 61, 574\u2013581. https:\/\/doi.org\/10.3340\/jkns.2018.0090 (2018).","journal-title":"J. Korean Neurosurg. Soc."},{"key":"51154_CR33","doi-asserted-by":"publisher","first-page":"1041 e1041","DOI":"10.1016\/j.wneu.2017.06.150","volume":"105","author":"R Feng","year":"2017","unstructured":"Feng, R., Loewenstern, J. & Caridi, J. Cervical burst fracture in a patient with contiguous 2-level cervical stand-alone cages. World Neurosurg. 105, 1041 e1041-1041 e1045. https:\/\/doi.org\/10.1016\/j.wneu.2017.06.150 (2017).","journal-title":"World Neurosurg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-51154-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-51154-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-51154-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T11:02:33Z","timestamp":1784286153000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-51154-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,18]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["51154"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-51154-1","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,18]]},"assertion":[{"value":"7 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the medical ethics committee of West China Hospital of Sichuan University (No.2019-946). Written informed consent was obtained from the participant. All procedures performed in studies involving human specimens were in accordance with the ethical standards of the institutional research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"22436"}}