{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T22:16:31Z","timestamp":1779142591471,"version":"3.51.4"},"reference-count":56,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T00:00:00Z","timestamp":1779062400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T00:00:00Z","timestamp":1779062400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Misr University for Science & Technology"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Differential current relays are the primary protection for detecting fault disturbances within the protection zone of three-phase synchronous generator stator windings. This paper presents a numerical backup protection scheme, based on the alienation algorithm, which serves as a redundant protection when the main differential current relay fails to isolate stator winding faults. The proposed method quantifies a set of alienation indices derived from fifteen Pearson correlation coefficients, calculated for the three-phase voltages and currents measured at the load terminals of the generator stator windings. A novel set of tripping characteristic curves, formulated from the alienation indices, enables the implementation of secondary protection functions. The method effectively detects fault disturbances and voltage\/current imbalance conditions in the three-phase generator signals. The experimental validation is performed using a motor\u2013generator set equipped with voltage and current transformers installed at the generator load terminals. The system hardware is emulated through a DAC and personal computer, while the alienation algorithm is implemented and processed using the LABVIEW software environment. Extensive experimental investigations were carried out to validate the proposed method under various fault scenarios affecting the generator. The results demonstrate the alienation algorithm\u2019s notable simplicity, effectiveness, reliability, and efficiency. Quantitatively, the protection scheme achieved security and dependability levels exceeding 99.80%, while its reliability and accuracy surpassed 99.60%. Moreover, the proposed scheme reduces the protection malfunction rate to only 0.37%. Compared to the coherence-based alienation method for analyzing voltage and current signals, the correlation-based alienation method provides superior response speed, improved performance metrics, greater accuracy, and a more reliable assessment of asymmetry and disturbance levels. An alienation tripping-time curve is created for the backup protection scheme, enabling time-delayed tripping under fault conditions, and its operating speed can be flexibly adjusted to meet specific protection requirements.<\/jats:p>","DOI":"10.1038\/s41598-026-51239-x","type":"journal-article","created":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T21:35:44Z","timestamp":1779140144000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Numerical backup protection scheme based on alienation indices of voltage and current measurements practically applied to synchronous generators"],"prefix":"10.1038","volume":"16","author":[{"given":"R. A.","family":"Mahmoud","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed Adel Esmaeel","family":"Salama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,5,18]]},"reference":[{"key":"51239_CR1","doi-asserted-by":"crossref","unstructured":"Mahmoud, R. A. & Elwakil, E. S. Experimental results and technique evaluation based on correlation function for a backup protection of synchronous generator stator windings. IET J. Eng. 12, 1190\u20131207 (2022).","DOI":"10.1049\/tje2.12198"},{"key":"51239_CR2","doi-asserted-by":"crossref","unstructured":"Mahmoud, R. A. Digital protection scheme based on Durbin Watson and Pearson similarity indices for current signals practically applied to power transformers. Int. J. Sci. Rep. 15, 12214 (2025).","DOI":"10.1038\/s41598-025-91491-1"},{"key":"51239_CR3","doi-asserted-by":"crossref","unstructured":"Khaled, A. J, Hamid, A. & Toliyat, G. Performance analysis of synchronous generators under stator windings ground faults near the star point-experimental verification. IEEE Trans. Energy Convers. 35, 1402\u20131410 (2020).","DOI":"10.1109\/TEC.2020.2980619"},{"key":"51239_CR4","doi-asserted-by":"crossref","unstructured":"Huijie, C. et al. Transient angle stability of paralleled synchronous and virtual synchronous generators in islanded micro-grids. IEEE Trans. Power Electron. 35, 8751\u20138765 (2020).","DOI":"10.1109\/TPEL.2020.2965152"},{"key":"51239_CR5","doi-asserted-by":"crossref","unstructured":"Edson, L. et al. Parameter estimation of a synchronous generator model under unbalanced operating conditions. Electric Power Syst. Res.  187, 1402\u20131410 (2020).","DOI":"10.1016\/j.epsr.2020.106487"},{"key":"51239_CR6","doi-asserted-by":"crossref","unstructured":"Gao, H. & Xu, B. Principle and implementation of current differential protection in distribution networks with high penetration of DGs. IEEE Trans. Power Deliv. 32 (Issue 1), 565\u2013574 (2017).","DOI":"10.1109\/TPWRD.2016.2628777"},{"key":"51239_CR7","doi-asserted-by":"crossref","unstructured":"Mahmoud, A. et al. Adaptive optimum coordination of overcurrent relays for deregulated distribution system considering parallel feeders. Electr. Eng. 103, 2 (2021).","DOI":"10.1007\/s00202-020-01187-0"},{"key":"51239_CR8","doi-asserted-by":"crossref","unstructured":"Mahmoud, A., Elsadd, W., Yousef, Almoataz, Y. & Abdelaziz, K. New adaptive coordination approach between generator-transformer unit overall differential protection and generator capability curves. Electr. power Energy Syst. 118, 1\u201315 (2020).","DOI":"10.1016\/j.ijepes.2019.105788"},{"key":"51239_CR9","doi-asserted-by":"crossref","unstructured":"Guo, L., Lei, Y., Xing, S., Yan, T. & Li, N. Deep convolutional transfer learning network: a new method for intelligent fault diagnosis of machines with unlabeled data. IEEE Trans. Ind. Electron. 66, 7316\u20137325 (2019).","DOI":"10.1109\/TIE.2018.2877090"},{"issue":"Issue 2","key":"51239_CR10","first-page":"205","volume":"49","author":"M Fayazi","year":"2017","unstructured":"Fayazi, M. & Haghjoo, F. Synchronous generator stator protection using a fuzzy logic-based voltage\u2010controlled overcurrent protection scheme. AUT J. Electr. Eng. 49 (Issue 2), 205\u2013214 (2017).","journal-title":"AUT J. Electr. Eng."},{"key":"51239_CR11","doi-asserted-by":"crossref","unstructured":"Vahdati, P. M., Seyedi, H. & Arjmandi, A. Synchronous generator stator protection using a fuzzy logic-based voltage\u2010controlled overcurrent protection scheme. Int. Trans. Electr. Energy Syst. 25, 326\u2013347 (2015).","DOI":"10.1002\/etep.1844"},{"key":"51239_CR12","doi-asserted-by":"crossref","unstructured":"Shweta, N. et al. Identification of coherency and critical generators set in real-time signal. Transm. Distrib. 11, 4456\u20134464 (2017).","DOI":"10.1049\/iet-gtd.2017.0327"},{"key":"51239_CR13","doi-asserted-by":"crossref","unstructured":"Allah, R. A. & Generation, I. E. T. Correlation-based synchro-check relay for power systems. Transm. Distrib. 12, 1109\u20131120 (2018).","DOI":"10.1049\/iet-gtd.2017.0448"},{"key":"51239_CR14","doi-asserted-by":"crossref","unstructured":"El-Saadawi, M. & Hatata, A. A novel protection scheme for synchronous generator stator windings based on SVM. J. Protect. Control Modern Power Syst. 2, 1\u201312 (2017).","DOI":"10.1186\/s41601-017-0057-x"},{"key":"51239_CR15","doi-asserted-by":"crossref","unstructured":"Gopinath, R., Santhosh Kumar, C., Upendranath, V. & Sai Kiran, P. V. R. Intelligent fault diagnosis of synchronous generators. J. Expert Syst. Appl. 45, 142\u2013149 (2016).","DOI":"10.1016\/j.eswa.2015.09.043"},{"key":"51239_CR16","doi-asserted-by":"crossref","unstructured":"Yadaiah, N. & Ravi, N. Fault detection in synchronous generators based on independent component analysis, In Proceedings of the International Conference on Frontiers of Intelligent Computing: Theory and Applications (FICTA), vol. 199 285\u2013292 (Springer, 2013).","DOI":"10.1007\/978-3-642-35314-7_33"},{"key":"51239_CR17","doi-asserted-by":"crossref","unstructured":"Javadian, S. A. M., Haghifam, H. R., Firoozabad, M. F. & Bathaee, S. M. T. Analysis of protection system\u2019s risk in distribution networks with DG. Electr. Power Energy Syst. 44 (Issue 1), 688\u2013695 (2013).","DOI":"10.1016\/j.ijepes.2012.08.034"},{"key":"51239_CR18","doi-asserted-by":"crossref","unstructured":"Coffele, F., Booth, C. & Dysko, A. An adaptive overcurrent protection scheme for distribution networks. IEEE Trans. Power Delivery. 30 (Issue 2), 561\u2013568 (2015).","DOI":"10.1109\/TPWRD.2013.2294879"},{"key":"51239_CR19","doi-asserted-by":"crossref","unstructured":"By, L. C., Khodayar, M. E. & Shahidehpour, M. Adaptive protection system for microgrids: protection practices of a functional microgrid system. IEEE Electrif. Mag. 2 (Issue 1), 66\u201380 (2014).","DOI":"10.1109\/MELE.2013.2297031"},{"key":"51239_CR20","doi-asserted-by":"crossref","unstructured":"Allah, R. A. Adaptive busbar differential relaying scheme during saturation period of current transformers based on alienation concept. IET Gener. Transm. Distrib. 10, 3803\u20133815 (2016).","DOI":"10.1049\/iet-gtd.2016.0239"},{"key":"51239_CR21","doi-asserted-by":"crossref","unstructured":"Ustun, T. S., Ozansoy, C. & Ustun, A. Fault current coefficient and time delay assignment for microgrid protection system with central protection unit. IEEE Trans. Power Syst. 28 (Issue 2), 598\u2013606 (2013).","DOI":"10.1109\/TPWRS.2012.2214489"},{"key":"51239_CR22","doi-asserted-by":"crossref","unstructured":"Haroun, S., Seghir, A. N. & Touati, S. Multiple features extraction and selection for detection and classification of stator winding faults. IET Electr. Power Appl. 12, 339\u2013346 (2018).","DOI":"10.1049\/iet-epa.2017.0457"},{"key":"51239_CR23","doi-asserted-by":"crossref","unstructured":"Ghanbari, T. Autocorrelation function-based technique for stator turn-fault detection of induction motor. IET Sci. Meas. Technol. 10, 100\u2013110 (2016).","DOI":"10.1049\/iet-smt.2015.0118"},{"key":"51239_CR24","doi-asserted-by":"crossref","unstructured":"Yaghobi, H. Fast predictive technique for reverse power detection in synchronous generator. IET Electric Power Appl. 12, 508\u2013517 (2018).","DOI":"10.1049\/iet-epa.2017.0491"},{"key":"51239_CR25","doi-asserted-by":"crossref","unstructured":"Wadie, F., Ebrahim, M. & Abd-Allah, M. An integrated fault detection algorithm for transmission, distribution and microgrid networks. IET Energy Syst. Integr. 1 (Issue 2), 104\u2013113 (2019).","DOI":"10.1049\/iet-esi.2019.0002"},{"key":"51239_CR26","doi-asserted-by":"crossref","unstructured":"Rahnama, M., Vahedi, A., Alikhani, A. M. & Montazeri, A. Machine-learning approach for fault detection in brushless synchronous generator using vibration signals. IET Sci. Meas. Technol. 13, 852\u2013861 (2019).","DOI":"10.1049\/iet-smt.2018.5523"},{"key":"51239_CR27","doi-asserted-by":"crossref","unstructured":"Mohamed, M. A. et al. Diagnostic modelling for induction motor faults via ANFIS algorithm and DWT-based feature extraction. Appl. Sci. 11, 9115 (2021).","DOI":"10.3390\/app11199115"},{"key":"51239_CR28","doi-asserted-by":"crossref","unstructured":"Ahmed, S. M., Abu-Rub, H. & Refaat, S. S. Diagnosis of stator turn-to-turn fault and stator voltage unbalance fault using ANFIS. Int. J. Electr. Comput. Eng. (IJECE) 3, 129\u2013135 (2013).","DOI":"10.11591\/ijece.v3i1.1854"},{"issue":"Issue 11","key":"51239_CR29","doi-asserted-by":"publisher","first-page":"2105","DOI":"10.3390\/en12112105","volume":"12","author":"P Esakimuthu","year":"2019","unstructured":"Esakimuthu, P., Shrinathan, Y. M. & Hisahide, N. A comparative study between machine learning algorithm and artificial intelligence neural network in detecting minor bearing fault of induction motors. Energies 12 (Issue 11), 2105 (2019). June 2019.","journal-title":"Energies"},{"key":"51239_CR30","doi-asserted-by":"crossref","unstructured":"Abd Allah, R. & Generation, I. E. T. Adaptive busbar differential relaying scheme during saturation period of current transformers based on alienation concept. Transm. Distrib. 10, 3803\u20133815 (2016).","DOI":"10.1049\/iet-gtd.2016.0239"},{"key":"51239_CR31","doi-asserted-by":"crossref","unstructured":"Mahmoud, R. A., Elwakil, E. S. & Generation, I. E. T. Experimental investigations using quadratic-tripping characteristics based on alienation\/coherence coefficients of voltage and current signals for synchronous generators protection. Transm. Distrib. 15, 2978\u20133000 (2021).","DOI":"10.1049\/gtd2.12235"},{"key":"51239_CR32","doi-asserted-by":"crossref","unstructured":"Mahmoud, R. A. Detection and assessment scheme of voltage and current unbalance for three phase synchronous generators using dual numerical techniques based on correlation and deviation percentage concepts. ET J. Eng. 9, 477\u2013495 (2021).","DOI":"10.1049\/tje2.12051"},{"issue":"Issue 4","key":"51239_CR33","first-page":"435","volume":"3","author":"H Bai","year":"2020","unstructured":"Bai, H. \u2018AI in arcing-HIF detection: a brief review\u2019. IET Smart Grid. 3 (Issue 4), 435\u2013444 (2020).","journal-title":"IET Smart Grid"},{"key":"51239_CR34","doi-asserted-by":"crossref","unstructured":"Stephen, K. & Ian, J. Application of machine learning in power grid fault detection and maintenance, Olojede et al. Energy Inf. 8, 2025 (2025).","DOI":"10.1186\/s42162-025-00574-w"},{"key":"51239_CR35","doi-asserted-by":"crossref","unstructured":"Sarajcev, P. & Lovric, D. Machine learning classifier for supporting generator\u2019s impedance-based relay protection functions. Energies 17, 1820 (2024).","DOI":"10.3390\/en17081820"},{"key":"51239_CR36","doi-asserted-by":"crossref","unstructured":"Lin, H., Sun, K., Juan, C. & Generation, I. E. T. Adaptive protection combined with machine learning for microgrids. Transm. Distrib. 13, 770\u2013779 (2019).","DOI":"10.1049\/iet-gtd.2018.6230"},{"key":"51239_CR37","doi-asserted-by":"crossref","unstructured":"Najar, A., Kazemi Karegar, H. & Esmaeilbeigi, S. Multi-agent protection scheme for microgrid using deep learning. IET Renew. Power Gener.  18, 663\u2013678 (2024).","DOI":"10.1049\/rpg2.12929"},{"key":"51239_CR38","doi-asserted-by":"crossref","unstructured":"Wang, J., Jing, S., Yao, Y., Wang, K. & Li, B. A state evaluation and fault diagnosis strategy for substation relay protection system integrating multiple intelligent algorithms. J. Eng. 2024, 12 (2024).","DOI":"10.1049\/tje2.70013"},{"key":"51239_CR39","doi-asserted-by":"crossref","unstructured":"Mahmoud, R. A. Experimental performance verification of an intelligent detection and assessment scheme for disturbances and imbalances of three-phase synchronous machine output using coherence estimators. Int. J. Sci. Rep. 14, 26278 (2024).","DOI":"10.1038\/s41598-024-76343-8"},{"key":"51239_CR40","doi-asserted-by":"crossref","unstructured":"Mahmoud, R. A. Experimental evaluation of differential voltage protection scheme based on a coherence function applied to AC machine stator windings. Int. J. Sci. Rep. 15, 12399 (2025).","DOI":"10.1038\/s41598-025-93210-2"},{"key":"51239_CR41","doi-asserted-by":"crossref","unstructured":"Mahmoud, R. A., Elwakil, E. S. & Generation, I. E. T. Experimental investigations using quadratic-tripping characteristics based on alienation\/coherence coefficients of voltage and current signals for synchronous generators protection. Transm. Distrib. 15, 2978\u20133000 (2021).","DOI":"10.1049\/gtd2.12235"},{"key":"51239_CR42","doi-asserted-by":"crossref","unstructured":"Mahmoud, R. A. Experimental performance examination of a coherence technique-based numerical differential current relay for AC machine stator windings protection. Int. J. Sci. Rep. 15, 7751 (2025).","DOI":"10.1038\/s41598-025-89092-z"},{"key":"51239_CR43","unstructured":"IEEE Standard Dictionary of Electrical and Electronics Terms, IEEE Std. 100\u20132021 (2021)."},{"key":"51239_CR44","unstructured":"IEEE Standard Test. Procedure for Polyphase Induction Motors and Generators. IEEE Std 112\u20132017 (2017)."},{"key":"51239_CR45","unstructured":"NEMA Standards Publication no. NEMA MG1-2021, Motors and Generators (National Electrical Manufacturers Association, 2021)."},{"key":"51239_CR46","doi-asserted-by":"crossref","unstructured":"Bollen, M. Definitions of voltage unbalance. IEEE Power Eng. Rev. 22, 49\u201350 (2002).","DOI":"10.1109\/MPER.2002.1045567"},{"key":"51239_CR47","unstructured":"IEC Standard 61000 -4-27:2020. Electromagnetic Compatibility (EMC)\u2013Part 4\u201327: Testing and Measurement Techniques \u2013 Unbalance, Immunity Test (International Electrotechnical Commission, 2020)."},{"key":"51239_CR48","doi-asserted-by":"crossref","unstructured":"Singh, S., Singh, A. & Thakur, P. Accurate performance assessment of IM with approximate current unbalance factor for NEMA definition. In 2014 16th International Conference on Harmonics and Quality of Power (ICHQP) . 674\u2013678 (2014).","DOI":"10.1109\/ICHQP.2014.6842805"},{"key":"51239_CR49","doi-asserted-by":"crossref","unstructured":"Ribeiro, E. G. et al. Real-time system for automatic detection and classification of single and multiple power quality disturbances. Measurement 128, 276\u2013283 (2018).","DOI":"10.1016\/j.measurement.2018.06.059"},{"key":"51239_CR50","doi-asserted-by":"crossref","unstructured":"Singh, U. & Singh, S. N. Application of Fractional Fourier Transform for classification of power quality disturbances. IET Sci. Meas. Technol. 11 (Issue 1), 67 (2017).","DOI":"10.1049\/iet-smt.2016.0194"},{"key":"51239_CR51","doi-asserted-by":"crossref","unstructured":"De, S. & Debnath, S. Real-time cross-correlation-based technique for detection and classification of power quality disturbances. IET Gener. Transm. Distrib. 12 (Issue 3), 688\u2013695 (2018).","DOI":"10.1049\/iet-gtd.2017.0507"},{"issue":"Issue 4","key":"51239_CR52","doi-asserted-by":"publisher","first-page":"3443","DOI":"10.1109\/TIA.2016.2536665","volume":"52","author":"R Kumar","year":"2016","unstructured":"Kumar, R., Singh, B. & Shahani, D. T. Symmetrical components-based modified technique for power-quality disturbances detection and classification. IEEE Trans. Ind. Appl. 52 (Issue 4), 3443\u20133450 (2016).","journal-title":"IEEE Trans. Ind. Appl."},{"key":"51239_CR53","doi-asserted-by":"crossref","unstructured":"Ibrahim, I., Al-Naimi, J. A., Ghaeb, M. J. & Baniyounis, M. A. Fast detection technique for voltage unbalance in three-phase power system. Int. J. Power Electron. Drive Syst. (IJPEDS) 12, 2230\u2009~\u20092242 (2021).","DOI":"10.11591\/ijpeds.v12.i4.pp2230-2242"},{"key":"51239_CR54","doi-asserted-by":"crossref","unstructured":"Mahmoud, R. A. Coherence-based integrated detection and assessment algorithm for voltages and currents unbalance\/disturbance in three-phase synchronous generators: a validation of simulation results. IET J. Eng. 5, e12272 (2023).","DOI":"10.1049\/tje2.12272"},{"key":"51239_CR55","doi-asserted-by":"crossref","unstructured":"Khadse, C. B., Chaudhari, M. A. & Borghate, V. B. Conjugate gradient back propagation based artificial neural network for real time power quality assessment. Int. J. Electr. Power Energy Syst. 82, 197\u2013206 (2016).","DOI":"10.1016\/j.ijepes.2016.03.020"},{"key":"51239_CR56","unstructured":"Abd Allah, R. Unbalance current detection for synchronous generator using alienation concept. Int. J. Eng. Adv. Technol. (IJEAT) 5 (Issue 3), 152\u2013162 (2016)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-51239-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-51239-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-51239-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T21:53:54Z","timestamp":1779141234000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-51239-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,18]]},"references-count":56,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["51239"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-51239-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,18]]},"assertion":[{"value":"22 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"15355"}}