{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T21:38:01Z","timestamp":1783114681365,"version":"3.54.6"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T00:00:00Z","timestamp":1778630400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T00:00:00Z","timestamp":1778630400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100007653","name":"Universit\u00e4tsklinikum Jena","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100007653","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Measuring the electrically evoked stapedius reflex threshold (eSRT) with electromyography (EMG) of the stapedius muscle (SM) may offer an objective approach for cochlear implant (CI) fitting. During unilateral CI surgery in 14 adult patients with single-sided deafness, a retrofacial or anterior approach were used to evaluate the feasibility of SM-EMG during acoustically and electrically elicited stapedius reflex (SR). No adverse events occurred. This neurophysiology-based method was compared with visual detection of the SR. Intraoperatively, the belly of the SM was accessed via the retrofacial approach in 11 patients and via an anterior approach in 3 patients. Objective SR determination using electrical stimulation through the CI combined with SM-EMG was feasible in 7 patients using the retrofacial approach, but in only 1 patient using the anterior approach. Overall, electrical stimulation elicited SM-EMG responses in 8 patients, whereas acoustic stimulation elicited responses in only 3 patients. When eSRT measurement via SM-EMG was possible, stimulation thresholds were equal or slightly lower than thresholds identified visually in 85% of all SR measurements. SM-EMG-based eSRT appears to be a viable approach to estimate the eSRT intraoperatively in CI users as it shows similar performance as current clinical intraoperative standard. Further investigation is needed to investigate the relationship between intraoperative SM-EMG-based eSRT and patients\u2019 comfort levels, establish correction factors, and potentially enable integration into future closed-loop smart CI devices.<\/jats:p>","DOI":"10.1038\/s41598-026-53093-3","type":"journal-article","created":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T21:14:41Z","timestamp":1778706881000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Electromyography of the stapedius muscle via a retrofacial approach and electrically evoked stapedius reflex during cochlear implant surgery: a prospective bicentric study"],"prefix":"10.1038","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9671-0784","authenticated-orcid":false,"given":"Orlando","family":"Guntinas-Lichius","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dirk","family":"Arnold","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerd Fabian","family":"Volk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniela","family":"Korth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Richter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rene","family":"Aschenbach","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fritz","family":"Schneider","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thore","family":"Schade-Mann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Gamerdinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jose Luis","family":"Vargas Luna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anke","family":"Tropitzsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hubert","family":"L\u00f6wenheim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,13]]},"reference":[{"key":"53093_CR1","unstructured":"Deafness and hearing loss. Vol. (World Health Organization, (2024). https:\/\/www.who.int\/news-room\/fact-sheets\/detail\/deafness-and-hearing-loss, 2024)."},{"key":"53093_CR2","doi-asserted-by":"crossref","unstructured":"Vaerenberg, B. et al. Cochlear implant programming: a global survey on the state of the art. Sci. World J. 1, 501738 (2014).","DOI":"10.1155\/2014\/501738"},{"key":"53093_CR3","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1007\/978-981-19-0452-3_22","volume-title":"Cochlear Implants: New and Future Directions","author":"C Psarros","year":"2022","unstructured":"Psarros, C. & Abrahams, Y. Recent Trends in Cochlear Implant Programming and (Re)habilitation. in Cochlear Implants: New and Future Directions (Sandra DeSaSouza ed). 441\u2013471 (Springer Nature Singapore, Singapore, (2022)."},{"key":"53093_CR4","doi-asserted-by":"publisher","first-page":"292","DOI":"10.3766\/jaaa.16117","volume":"29","author":"KCL de Andrade","year":"2018","unstructured":"de Andrade, K. C. L. et al. The Value of Electrically Evoked Stapedius Reflex in Determining the Maximum Comfort Level of a Cochlear Implant. J. Am. Acad. Audiol. 29, 292\u2013299 (2018).","journal-title":"J. Am. Acad. Audiol."},{"key":"53093_CR5","first-page":"S118","volume":"18","author":"B Lindstr\u00f6m","year":"1997","unstructured":"Lindstr\u00f6m, B. & Bredberg, G. Intraoperative electrical stimulation of the stapedius reflex in children. Am. J. Otol. 18, S118\u2013119 (1997).","journal-title":"Am. J. Otol"},{"key":"53093_CR6","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1097\/00003446-199404000-00008","volume":"15","author":"LG Spivak","year":"1994","unstructured":"Spivak, L. G. & Chute, P. M. The relationship between electrical acoustic reflex thresholds and behavioral comfort levels in children and adult cochlear implant patients. Ear Hear. 15, 184\u2013192 (1994).","journal-title":"Ear Hear."},{"key":"53093_CR7","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1001\/archotol.127.8.963","volume":"127","author":"M Bresnihan","year":"2001","unstructured":"Bresnihan, M., Norman, G., Scott, F. & Viani, L. Measurement of comfort levels by means of electrical stapedial reflex in children. Arch. Otolaryngol. Head Neck Surg. 127, 963\u2013966 (2001).","journal-title":"Arch. Otolaryngol. Head Neck Surg."},{"key":"53093_CR8","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1097\/01.aud.0000146178.84065.b3","volume":"25","author":"KA Gordon","year":"2004","unstructured":"Gordon, K. A., Papsin, B. C. & Harrison, R. V. Toward a battery of behavioral and objective measures to achieve optimal cochlear implant stimulation levels in children. Ear Hear. 25, 447\u2013463 (2004).","journal-title":"Ear Hear."},{"key":"53093_CR9","first-page":"70","volume":"5","author":"J Kosaner","year":"2009","unstructured":"Kosaner, J., Anderson, I., Turan, Z. & Deibl, M. The use of ESRT in fitting children with cochlear implants. J. Int. Adv. Otology. 5, 70\u201379 (2009).","journal-title":"J. Int. Adv. Otology"},{"key":"53093_CR10","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1097\/00003446-198802000-00010","volume":"9","author":"J Jerger","year":"1988","unstructured":"Jerger, J., Oliver, T. A. & Chmiel, R. A. Prediction of dynamic range from stapedius reflex in cochlear implant patients. Ear Hear. 9, 4\u20138 (1988).","journal-title":"Ear Hear."},{"key":"53093_CR11","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1177\/039139889201500712","volume":"15","author":"K Stephan","year":"1992","unstructured":"Stephan, K. & Welzl-M\u00fcller, K. Stapedius reflex in patients with an inner ear prosthesis. Int. J. Artif. Organs. 15, 436\u2013439 (1992).","journal-title":"Int. J. Artif. Organs"},{"issue":"Suppl 1","key":"53093_CR12","doi-asserted-by":"publisher","first-page":"43s","DOI":"10.1097\/AUD.0b013e31829c70d9","volume":"34","author":"KS Schairer","year":"2013","unstructured":"Schairer, K. S., Feeney, M. P. & Sanford, C. A. Acoustic reflex measurement. Ear Hear. 34 (Suppl 1), 43s\u201347s (2013).","journal-title":"Ear Hear."},{"key":"53093_CR13","doi-asserted-by":"publisher","first-page":"112","DOI":"10.17712\/1658-3183.1403","volume":"11","author":"C Kopuz","year":"2006","unstructured":"Kopuz, C., Turgut, S., Kale, A. & Aydin, M. E. Absence of both stapedius tendon and muscle. Neurosciences (Riyadh). 11, 112\u2013114 (2006).","journal-title":"Neurosciences (Riyadh)"},{"key":"53093_CR14","doi-asserted-by":"publisher","first-page":"e174","DOI":"10.1097\/MAO.0000000000003413","volume":"43","author":"D Arnold","year":"2022","unstructured":"Arnold, D. et al. Accessing the Stapedius Muscle Via Novel Surgical Retrofacial Approach: A Cadaveric Feasibility Study. Otol Neurotol. 43, e174\u2013e180 (2022).","journal-title":"Otol Neurotol"},{"key":"53093_CR15","doi-asserted-by":"publisher","first-page":"e0272943","DOI":"10.1371\/journal.pone.0272943","volume":"17","author":"O Guntinas-Lichius","year":"2022","unstructured":"Guntinas-Lichius, O. et al. Accessing the stapedius muscle via novel surgical retrofacial approach during cochlear implantation surgery: Intraoperative results on feasibility and safety. PLoS One. 17, e0272943 (2022).","journal-title":"PLoS One"},{"key":"53093_CR16","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1007\/s00405-019-05773-2","volume":"277","author":"GF Volk","year":"2020","unstructured":"Volk, G. F. et al. Dyna-CT of the temporal bone for case-specific three-dimensional rendering of the stapedial muscle for planning of electrically evoked stapedius reflex threshold determination during cochlear implantation directly from the stapedius muscle via a retrofacial approach: a pilot study. Eur. Arch. Otorhinolaryngol. 277, 975\u2013985 (2020).","journal-title":"Eur. Arch. Otorhinolaryngol."},{"key":"53093_CR17","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1007\/s11548-020-02288-8","volume":"16","author":"P Marquez","year":"2021","unstructured":"Marquez, P. et al. The use of a surgical planning tool for evaluating the optimal surgical accessibility to the stapedius muscle via a retrofacial approach during cochlear implant surgery: a feasibility study. Int. J. Comput. Assist. Radiol. Surg. 16, 331\u2013343 (2021).","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"53093_CR18","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1179\/1754762814Y.0000000064","volume":"15","author":"S Raghunandhan","year":"2014","unstructured":"Raghunandhan, S., Ravikumar, A., Kameswaran, M., Mandke, K. & Ranjith, R. A clinical study of electrophysiological correlates of behavioural comfort levels in cochlear implantees. Cochlear Implants Int. 15, 145\u2013160 (2014).","journal-title":"Cochlear Implants Int."},{"key":"53093_CR19","doi-asserted-by":"crossref","unstructured":"Mishra, R. & Nandurkar, A. Correlation between behaviorally measured comfort (c) levels and electrically evoked stapedius reflex thresholds (ESRT) in children with unilateral cochlear implant. Journal Otolaryngology-ENT Research 11, 201-6 (2019).","DOI":"10.15406\/joentr.2019.11.00435"},{"key":"53093_CR20","first-page":"59","volume":"104","author":"D Djeri\u0107","year":"1987","unstructured":"Djeri\u0107, D. & Savi\u0107, D. [Anatomical variations and anomalies of the musculus stapedius tendon. Study by scanning electron microscopy]. Ann. Otolaryngol. Chir. Cervicofac. 104, 59\u201363 (1987).","journal-title":"Ann. Otolaryngol. Chir. Cervicofac."},{"key":"53093_CR21","doi-asserted-by":"publisher","first-page":"e550","DOI":"10.1097\/MAO.0000000000001878","volume":"39","author":"R Yilmazer","year":"2018","unstructured":"Yilmazer, R. et al. The Feasibility of Retrofacial Approach for Cochlear Implantation. Otol Neurotol. 39, e550\u2013e556 (2018).","journal-title":"Otol Neurotol"},{"key":"53093_CR22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/MAO.0b013e31818a0898","volume":"30","author":"HW Pau","year":"2009","unstructured":"Pau, H. W. et al. Electromyographical recording of the electrically elicited stapedius reflex via a bipolar hook electrode. Otol Neurotol. 30, 1\u20136 (2009).","journal-title":"Otol Neurotol"},{"key":"53093_CR23","doi-asserted-by":"publisher","first-page":"146","DOI":"10.3109\/00206090009073067","volume":"39","author":"B Almqvist","year":"2000","unstructured":"Almqvist, B., Harris, S. & Shallop, J. K. Objective intraoperative method to record averaged electromyographic stapedius muscle reflexes in cochlear implant patients. Audiology 39, 146\u2013152 (2000).","journal-title":"Audiology"},{"key":"53093_CR24","doi-asserted-by":"publisher","first-page":"108290","DOI":"10.1016\/j.heares.2021.108290","volume":"408","author":"A Zarowski","year":"2021","unstructured":"Zarowski, A. et al. Intraoperative recordings of electromyogenic responses from the human stapedius muscle. Hear. Res. 408, 108290 (2021).","journal-title":"Hear. Res."},{"key":"53093_CR25","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1017\/S0022215110002392","volume":"125","author":"HW Pau","year":"2011","unstructured":"Pau, H. W., Ehrt, K., Just, T., Sievert, U. & Dahl, R. How reliable is visual assessment of the electrically elicited stapedius reflex threshold during cochlear implant surgery, compared with tympanometry? J. Laryngol Otol. 125, 271\u2013273 (2011).","journal-title":"J. Laryngol Otol"},{"key":"53093_CR26","doi-asserted-by":"crossref","unstructured":"Weiss, B. G. et al., An Objective Method to Determine the Electrically Evoked Stapedius Reflex Threshold During Cochlea Implantation. Otology & Neurotology 39, e5-e11 (2018).","DOI":"10.1097\/MAO.0000000000001611"},{"key":"53093_CR27","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1179\/1754762810Y.0000000001","volume":"13","author":"T Van Den Abbeele","year":"2012","unstructured":"Van Den Abbeele, T. et al. Multicentre investigation on electrically evoked compound action potential and stapedius reflex: how do these objective measures relate to implant programming parameters? Cochlear Implants Int. 13, 26\u201334 (2012).","journal-title":"Cochlear Implants Int."},{"key":"53093_CR28","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1055\/s-2007-997095","volume":"73","author":"D Gnadeberg","year":"1994","unstructured":"Gnadeberg, D. et al. [Effect of anesthesia on the intraoperative elicited stapedius reflex]. Laryngorhinootologie 73, 132\u2013135 (1994).","journal-title":"Laryngorhinootologie"},{"key":"53093_CR29","first-page":"598","volume":"19","author":"MJ Makhdoum","year":"1998","unstructured":"Makhdoum, M. J., Snik, A. F., Stollman, M. H., de Grood, P. M. & van den Broek, P. The influence of the concentration of volatile anesthetics on the stapedius reflex determined intraoperatively during cochlear implantation in children. Am. J. Otol. 19, 598\u2013603 (1998).","journal-title":"Am. J. Otol"},{"key":"53093_CR30","doi-asserted-by":"publisher","first-page":"1050","DOI":"10.1177\/000348940311201210","volume":"112","author":"A Schultz","year":"2003","unstructured":"Schultz, A. et al. Intraoperative electrically elicited stapedius reflex threshold is related to the dosage of hypnotic drugs in general anesthesia. Ann. Otol Rhinol Laryngol. 112, 1050\u20131055 (2003).","journal-title":"Ann. Otol Rhinol Laryngol"},{"key":"53093_CR31","doi-asserted-by":"publisher","first-page":"1480","DOI":"10.1213\/ane.0b013e31819bdfd5","volume":"108","author":"MW Crawford","year":"2009","unstructured":"Crawford, M. W. et al. Dose-dependent suppression of the electrically elicited stapedius reflex by general anesthetics in children undergoing cochlear implant surgery. Anesth. Analg. 108, 1480\u20131487 (2009).","journal-title":"Anesth. Analg"},{"key":"53093_CR32","doi-asserted-by":"publisher","first-page":"68","DOI":"10.5935\/1808-8694.20140014","volume":"80","author":"KC Andrade","year":"2014","unstructured":"Andrade, K. C. et al. The importance of electrically evoked stapedial reflex in cochlear implant. Braz J. Otorhinolaryngol. 80, 68\u201377 (2014).","journal-title":"Braz J. Otorhinolaryngol."},{"key":"53093_CR33","doi-asserted-by":"crossref","unstructured":"Yathiraj, A., Manjula, P., Geetha, C., Jawahar Antony, P. & Megha Comparison of electrically evoked stapedial reflexes in patients with cochlear implants surgically implanted using Veria and posterior tympanotomy approaches. The J. Laryngology & Otology, 138, 858\u2013863 (2024).","DOI":"10.1017\/S0022215124000227"},{"key":"53093_CR34","unstructured":"Hodges, A., Butts, S. & King, J. Cochlear Implants Objective Measures 81\u201396 (Whurr publishers Los Angeles, 2003)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-53093-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-53093-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-53093-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T21:29:20Z","timestamp":1778707760000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-53093-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,13]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["53093"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-53093-3","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,13]]},"assertion":[{"value":"20 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors have indicated that they have no conflict of interest.J.L.V.L. is an employee of MED-EL Elektromedizinische Ger\u00e4te GmbH, Innsbruck, Austria.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The study was conducted in accordance with the Declaration of Helsinki and approved by both local ethics committees. Patients gave written informed consent for inclusion in this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}],"article-number":"15065"}}