{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T00:01:12Z","timestamp":1784678472612,"version":"3.55.0"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T00:00:00Z","timestamp":1779235200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T00:00:00Z","timestamp":1784678400000},"content-version":"vor","delay-in-days":63,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Manipal Academy of Higher Education, Manipal"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Improving overall health and preventing complications is crucial for timely and effective treatment of diabetes patients. In this direction, accurate measurement and detection of glucose concentration in blood is essential. The aim of this study is to develop an affordable, reliable and accurate Point-of-Care (POC) diagnostic platform for glucose concentration detection using microfluidic and colorimetric principles. A microfluidic chip is fabricated which provides the base for efficient colorimetric reaction. The proposed system requires only\u2009~\u200920 \u00b5L of sample per microwell, with a colorimetric reaction time of 3\u20134\u00a0min. The chip is positioned inside a compact, USB-powered, 3D printed image capture device affixed with a high-resolution camera so that variables such as camera position, focal distance and lighting conditions can be controlled. The analysis workflow is adaptable for integration with embedded systems or laptops, making it suitable for real-time deployment in Point-of-Care settings without the need for smartphones or calibration tools. The images captured inside the device (1280 in total, corresponding to 16 glucose concentration levels ranging from 50 to 200\u00a0mg\/dL) were labeled based on known concentration levels and subjected to standardized preprocessing. Key preprocessing steps included Region of Interest (ROI) extraction using a fixed box detection algorithm, normalization of pixel values, image resizing to 128\u2009\u00d7\u2009128 pixels, and standardization using ImageNet parameters. These ensured uniformity and robustness prior to feature extraction and machine learning classification. The classifiers used are Decision Tree (DT), Random Forest (RF), Support Vector Machine (SVM), Neural Networks (NN), and K-Nearest Neighbours (KNN). The RF machine learning classifier achieved the highest cross-validation accuracy of 87.47% and precision of 89.14%, demonstrating its ability to effectively distinguish between different glucose concentration levels. The confusion matrix and ROC curve analysis further validated the model\u2019s robustness, with minimal misclassifications and a high mean AUC value of 0.9509. The results thus highlight the potential of image-based glucose concentration estimation as a cost-effective and scalable solution for real-time monitoring in biomedical applications.<\/jats:p>","DOI":"10.1038\/s41598-026-54054-6","type":"journal-article","created":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T02:56:27Z","timestamp":1779245787000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Development of colorimetric and machine learning based accurate glucose detection platform for point of care applications"],"prefix":"10.1038","volume":"16","author":[{"given":"Mithun","family":"Kanchan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pragna","family":"Harish","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tushit","family":"Chatterjee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omkar S","family":"Powar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,20]]},"reference":[{"issue":"21","key":"54054_CR1","doi-asserted-by":"publisher","first-page":"9002","DOI":"10.1021\/ac302506k","volume":"84","author":"FR de Souza","year":"2012","unstructured":"de Souza, F. R., Alves, G. L. & Coltro, W. K. T. Capillary-driven toner-based microfluidic devices for clinical diagnostics with colorimetric detection. Anal. Chem. 84(21), 9002\u20139007 (2012).","journal-title":"Anal. Chem."},{"issue":"14","key":"54054_CR2","doi-asserted-by":"publisher","first-page":"4995","DOI":"10.1039\/C4AY00260A","volume":"6","author":"KA Oliveira","year":"2014","unstructured":"Oliveira, K. A., e Silva, P. B. M., de Souza, F. R., Martins, F. T. & Coltro, W. K. T. Kinetic study of glucose oxidase on microfluidic toner-based analytical devices for clinical diagnostics with image-based detection. Anal. Methods. 6(14), 4995\u20135000 (2014).","journal-title":"Anal. Methods"},{"key":"54054_CR3","first-page":"197","volume":"28","author":"P Silva","year":"2017","unstructured":"Silva, P., Oliveira, K. A. & Coltro, W. K. Colorimetric detection of glucose in biological fluids using toner-based microzone plates. J. Braz. Chem. Soc. 28, 197\u2013201 (2017).","journal-title":"J. Braz. Chem. Soc."},{"issue":"11","key":"54054_CR4","doi-asserted-by":"publisher","first-page":"2280","DOI":"10.1016\/j.jbiomech.2015.11.031","volume":"49","author":"V Faustino","year":"2016","unstructured":"Faustino, V., Catarino, S. O., Lima, R. & Minas, G. Biomedical microfluidic devices by using low-cost fabrication techniques: A review. J. Biomech. 49(11), 2280\u20132292 (2016).","journal-title":"J. Biomech."},{"issue":"1","key":"54054_CR5","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1021\/acs.analchem.5b04005","volume":"88","author":"Y Lin","year":"2016","unstructured":"Lin, Y. et al. Magnetic graphene nanosheet-based microfluidic device for homogeneous real-time electronic monitoring of pyrophosphatase activity using enzymatic hydrolysate-induced release of copper ion. Anal. Chem. 88(1), 1030\u20131038 (2016).","journal-title":"Anal. Chem."},{"key":"54054_CR6","doi-asserted-by":"publisher","first-page":"134768","DOI":"10.1016\/j.foodchem.2022.134768","volume":"404","author":"T Zhao","year":"2023","unstructured":"Zhao, T. et al. Smartphone-based colorimetric sensor array using gold nanoparticles for rapid distinguishment of multiple pesticides in real samples. Food Chem. 404, 134768 (2023).","journal-title":"Food Chem."},{"issue":"71","key":"54054_CR7","doi-asserted-by":"publisher","first-page":"37637","DOI":"10.1039\/C4RA07112C","volume":"4","author":"T de Garcia","year":"2014","unstructured":"de Garcia, T., Cardoso, P., Garcia, T. M. G., Carrilho, C. D., Coltro, W. K. T. & E., & A handheld stamping process to fabricate microfluidic paper-based analytical devices with chemically modified surface for clinical assays. RSC Adv. 4(71), 37637\u201337644 (2014).","journal-title":"RSC Adv."},{"issue":"21","key":"54054_CR8","doi-asserted-by":"publisher","first-page":"5560","DOI":"10.1039\/C4AN01147C","volume":"139","author":"E Evans","year":"2014","unstructured":"Evans, E., Gabriel, E. F. M., Benavidez, T. E., Coltro, W. K. T. & Garcia, C. D. Modification of microfluidic paper-based devices with silica nanoparticles. Analyst 139(21), 5560\u20135567 (2014).","journal-title":"Analyst"},{"key":"54054_CR9","doi-asserted-by":"crossref","unstructured":"Liu, S., Su, W. & Ding, X. A review on microfluidic paper-based analytical devices for glucose detection. Sensors 16(12), 2086 (2016).","DOI":"10.3390\/s16122086"},{"key":"54054_CR10","doi-asserted-by":"publisher","first-page":"774","DOI":"10.1016\/j.bios.2015.10.032","volume":"77","author":"Y Xia","year":"2016","unstructured":"Xia, Y., Si, J. & Li, Z. Fabrication techniques for microfluidic paper-based analytical devices and their applications for biological testing: A review. Biosens. Bioelectron. 77, 774\u2013789 (2016).","journal-title":"Biosens. Bioelectron."},{"issue":"15","key":"54054_CR11","doi-asserted-by":"publisher","first-page":"4749","DOI":"10.1039\/C6AN00430J","volume":"141","author":"EF Gabriel","year":"2016","unstructured":"Gabriel, E. F. et al. Highly sensitive colorimetric detection of glucose and uric acid in biological fluids using chitosan-modified paper microfluidic devices. Analyst 141(15), 4749\u20134756 (2016).","journal-title":"Analyst"},{"issue":"4","key":"54054_CR12","doi-asserted-by":"publisher","first-page":"104","DOI":"10.3390\/mi8040104","volume":"8","author":"EFM Gabriel","year":"2017","unstructured":"Gabriel, E. F. M., Garcia, P. T., Lopes, F. M., Coltro, W. K. & T Based colorimetric biosensor for tear glucose measurements. Micromachines 8(4), 104 (2017).","journal-title":"Micromachines"},{"key":"54054_CR13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.aca.2017.03.037","volume":"970","author":"GG Morbioli","year":"2017","unstructured":"Morbioli, G. G., Mazzu-Nascimento, T., Stockton, A. M. & Carrilho, E. Technical aspects and challenges of colorimetric detection with microfluidic paper-based analytical devices (\u00b5PADs)-A review. Anal. Chim. Acta. 970, 1\u201322 (2017).","journal-title":"Anal. Chim. Acta"},{"key":"54054_CR14","doi-asserted-by":"crossref","unstructured":"de Freitas, S. V., de Souza, F. R., Rodrigues Neto, J. C., Vasconcelos, G. A., Abdelnur,P. V., Vaz, B. G. et al. Uncovering the formation of color gradients for glucose colorimetric assays on microfluidic paper-based analytical devices by mass spectrometry imaging. Anal. Chem. 90(20), 11949\u201311954 (2018).","DOI":"10.1021\/acs.analchem.8b02384"},{"key":"54054_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00604-017-2575-7","volume":"185","author":"I Ortiz-G\u00f3mez","year":"2018","unstructured":"Ortiz-G\u00f3mez, I. et al. Microfluidic paper-based device for colorimetric determination of glucose based on a metal-organic framework acting as peroxidase mimetic. Microchim. Acta. 185, 1\u20138 (2018).","journal-title":"Microchim. Acta"},{"key":"54054_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10544-019-0388-7","volume":"21","author":"H Zhang","year":"2019","unstructured":"Zhang, H., Smith, E., Zhang, W. & Zhou, A. Inkjet printed microfluidic paper-based analytical device (\u00b5PAD) for glucose colorimetric detection in artificial urine. Biomed. Microdevices. 21, 1\u201310 (2019).","journal-title":"Biomed. Microdevices"},{"issue":"6","key":"54054_CR17","doi-asserted-by":"publisher","first-page":"1364","DOI":"10.1109\/JMEMS.2005.859087","volume":"14","author":"DA Bartholomeusz","year":"2005","unstructured":"Bartholomeusz, D. A., Boutt\u00e9, R. W. & Andrade, J. D. Xurography: Rapid prototyping of microstructures using a cutting plotter. J. Microelectromech. Syst. 14(6), 1364\u20131374 (2005).","journal-title":"J. Microelectromech. Syst."},{"issue":"3","key":"54054_CR18","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1039\/B918089C","volume":"10","author":"PK Yuen","year":"2010","unstructured":"Yuen, P. K. & Goral, V. N. Low-cost rapid prototyping of flexible microfluidic devices using a desktop digital craft cutter. Lab. Chip. 10(3), 384\u2013387 (2010).","journal-title":"Lab. Chip"},{"key":"54054_CR19","doi-asserted-by":"crossref","unstructured":"Moreira, N. S., Chagas, C. L., Oliveira, K. A., Duarte-Junior, G. F., de Souza, F.R., Santhiago, M. et al. Fabrication of microwell plates and microfluidic devices in polyester films using a cutting printer. Anal. Chim. Acta 1119, 1\u201310 (2020).","DOI":"10.1016\/j.aca.2020.04.047"},{"key":"54054_CR20","doi-asserted-by":"crossref","unstructured":"Stallcop, L. E., \u00c1lvarez-Garc\u00eda, Y. R., Reyes-Ramos, A. M., Ramos-Cruz, K. P., Morgan,M. M., Shi, Y. et al. Razor-printed sticker microdevices for cell-based applications. Lab Chip 18(3), 451\u2013462 (2018).","DOI":"10.1039\/C7LC00724H"},{"key":"54054_CR21","doi-asserted-by":"crossref","unstructured":"Delgado, P., Luna, C. A., Dissanayaka, A., Oshinowo, O., Waggoner, J. J., Schley, S. et al. An economical in-class sticker microfluidic activity develops student expertise in microscale physics and device manufacturing. Lab Chip 24(8), 2176\u20132192 (2024).","DOI":"10.1039\/D3LC00912B"},{"issue":"6","key":"54054_CR22","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1039\/C5LC01524C","volume":"16","author":"K Yang","year":"2016","unstructured":"Yang, K., Peretz-Soroka, H., Liu, Y. & Lin, F. Novel developments in mobile sensing based on the integration of microfluidic devices and smartphones. Lab. Chip. 16(6), 943\u2013958 (2016).","journal-title":"Lab. Chip"},{"issue":"7","key":"54054_CR23","doi-asserted-by":"publisher","first-page":"1206","DOI":"10.1039\/C6LC01577H","volume":"17","author":"K Yamada","year":"2017","unstructured":"Yamada, K., Shibata, H., Suzuki, K. & Citterio, D. Toward practical application of paper-based microfluidics for medical diagnostics: State-of-the-art and challenges. Lab. Chip. 17(7), 1206\u20131249 (2017).","journal-title":"Lab. Chip"},{"issue":"48","key":"54054_CR24","doi-asserted-by":"publisher","first-page":"27091","DOI":"10.1039\/C8RA04006K","volume":"8","author":"A Motalebizadeh","year":"2018","unstructured":"Motalebizadeh, A., Bagheri, H., Asiaei, S., Fekrat, N. & Afkhami, A. New portable smartphone-based PDMS microfluidic kit for the simultaneous colorimetric detection of arsenic and mercury. RSC Adv. 8(48), 27091\u201327100 (2018).","journal-title":"RSC Adv."},{"key":"54054_CR25","doi-asserted-by":"crossref","unstructured":"Xia, Y., Chen, Y., Tang, Y., Cheng, G., Yu, X., He, H. et al. Smartphone-based point-of-care microfluidic platform fabricated with a ZnO nanorod template for colorimetric virus detection. ACS Sens. 4(12), 3298\u20133307 (2019).","DOI":"10.1021\/acssensors.9b01927"},{"key":"54054_CR26","doi-asserted-by":"crossref","unstructured":"Potluri, V., Kathiresan, P. S., Kandula, H., Thirumalaraju, P., Kanakasabapathy, M.K., Pavan, S. K. S. et al. An inexpensive smartphone-based device for point-of-care ovulation testing. Lab Chip 19(1), 59\u201367 (2019).","DOI":"10.1039\/C8LC00792F"},{"key":"54054_CR27","doi-asserted-by":"crossref","unstructured":"Luo, W., Deng, J., He, J., Han, Z., Huang, C., Li, Y. et al. A smartphone-based multi-wavelength photometer for on-site detection of the liquid colorimetric assays for clinical biochemical analyses. Sens. Actuat. B Chem. 329, 129266 (2021).","DOI":"10.1016\/j.snb.2020.129266"},{"issue":"16","key":"54054_CR28","doi-asserted-by":"publisher","first-page":"6394","DOI":"10.1021\/acs.analchem.0c05387","volume":"93","author":"MJ Uddin","year":"2021","unstructured":"Uddin, M. J., Bhuiyan, N. H., Hong, J. H. & Shim, J. S. Smartphone-based fully automated optofluidic device with laser irradiation-induced image whitening. Anal. Chem. 93(16), 6394\u20136402 (2021).","journal-title":"Anal. Chem."},{"issue":"9","key":"54054_CR29","doi-asserted-by":"publisher","first-page":"2101690","DOI":"10.1002\/admt.202101690","volume":"7","author":"NH Bhuiyan","year":"2022","unstructured":"Bhuiyan, N. H., Uddin, M. J., Lee, J., Hong, J. H. & Shim, J. S. An internet-of\u2010disease system for COVID\u201019 testing using saliva by an AI\u2010controlled microfluidic ELISA device. Adv. Mater. Technol. 7(9), 2101690 (2022b).","journal-title":"Adv. Mater. Technol."},{"key":"54054_CR30","doi-asserted-by":"publisher","first-page":"131336","DOI":"10.1016\/j.snb.2021.131336","volume":"355","author":"MM Rahman","year":"2022","unstructured":"Rahman, M. M., Uddin, M. J., Hong, J. H., Bhuiyan, N. H. & Shim, J. S. Lab-in-a-Cup (LiC): An autonomous fluidic device for daily urinalysis using smartphone. Sens. Actuat. B 355, 131336 (2022).","journal-title":"Sens. Actuat. B"},{"issue":"23","key":"54054_CR31","doi-asserted-by":"publisher","first-page":"4666","DOI":"10.1039\/D2LC00824F","volume":"22","author":"SK Biswas","year":"2022","unstructured":"Biswas, S. K. et al. Instrument-free single-step direct estimation of the plasma glucose level from one drop of blood using smartphone-interfaced analytics on a paper strip. Lab. Chip. 22(23), 4666\u20134679 (2022).","journal-title":"Lab. Chip"},{"key":"54054_CR32","doi-asserted-by":"publisher","first-page":"129037","DOI":"10.1016\/j.snb.2020.129037","volume":"329","author":"\u00d6B Mercan","year":"2021","unstructured":"Mercan, \u00d6. B., K\u0131l\u0131\u00e7, V. & \u015een, M. Machine learning-based colorimetric determination of glucose in artificial saliva with different reagents using a smartphone coupled \u00b5PAD. Sens. Actuat. B. 329, 129037 (2021).","journal-title":"Sens. Actuat. B"},{"key":"54054_CR33","doi-asserted-by":"crossref","unstructured":"Lee, T., Lee, H. T., Hong, J., Roh, S., Lee, K., Choi, Y. et al. A regression-based machine learning approach for pH and glucose detection with redox-sensitive colorimetric paper sensors. Anal. Methods 14(46), 4749\u20134755 (2022).","DOI":"10.1039\/D2AY01329K"},{"issue":"2","key":"54054_CR34","doi-asserted-by":"publisher","first-page":"347","DOI":"10.2116\/analsci.21P253","volume":"38","author":"V K\u0131l\u0131\u00e7","year":"2022","unstructured":"K\u0131l\u0131\u00e7, V., Mercan, \u00d6. B., Tetik, M., Kap, \u00d6. & Horzum, N. Non-enzymatic colorimetric glucose detection based on Au\/Ag nanoparticles using smartphone and machine learning. Anal. Sci. 38(2), 347\u2013358 (2022).","journal-title":"Anal. Sci."},{"key":"54054_CR35","doi-asserted-by":"publisher","first-page":"134835","DOI":"10.1016\/j.snb.2023.134835","volume":"400","author":"S Ghateii","year":"2024","unstructured":"Ghateii, S. & Jahanshahi, A. Colorimetric detection of glucose with smartphone-coupled \u00b5PADs: Harnessing machine learning algorithms in variable lighting environments. Sens. Actuat. B. 400, 134835 (2024).","journal-title":"Sens. Actuat. B"},{"key":"54054_CR36","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.matpr.2022.09.443","volume":"73","author":"A Poddar","year":"2023","unstructured":"Poddar, A., Rangwani, N., Palekar, S. & Kalambe, J. Glucose monitoring system using machine learning. Mater. Today Proc. 73, 100\u2013107 (2023).","journal-title":"Mater. Today Proc."},{"issue":"1","key":"54054_CR37","doi-asserted-by":"publisher","first-page":"28377","DOI":"10.1038\/s41598-024-79581-y","volume":"14","author":"M Kanchan","year":"2024","unstructured":"Kanchan, M., Tambe, P. K., Bharati, S. & Powar, O. S. Convolutional neural network for colorimetric glucose detection using a smartphone and novel multilayer polyvinyl film microfluidic device. Sci. Rep. 14(1), 28377 (2024).","journal-title":"Sci. Rep."},{"key":"54054_CR38","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1007\/s42452-025-06859-9","volume":"7","author":"M Kanchan","year":"2025","unstructured":"Kanchan, M., Arun, P. A. H. & Chutke, S. R. Pilot study: A low-cost, point-of-care microfluidic chip for smartphone-integrated colorimetric detection using convolutional neural networks. Discover Appl. Sci. 7, 829. https:\/\/doi.org\/10.1007\/s42452-025-06859-9 (2025).","journal-title":"Discover Appl. Sci."},{"issue":"5","key":"54054_CR39","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1007\/s00604-025-07136-7","volume":"192","author":"GY Choi","year":"2025","unstructured":"Choi, G. Y. et al. Transfer learning and data augmentation for glucose concentration prediction from colorimetric biosensor images. Microchim. Acta. 192(5), 287 (2025).","journal-title":"Microchim. Acta"},{"key":"54054_CR40","doi-asserted-by":"crossref","unstructured":"Lee, T., Yu, J., Lee, S. W., Oh, S. H., Kang, D., Son, H. et al. Machine learning-integrated biomimetic electronic noses: Future perspectives. Microchem. J. 213, 113638 (2025).","DOI":"10.1016\/j.microc.2025.113638"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54054-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54054-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54054-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T23:07:11Z","timestamp":1784675231000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54054-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,20]]},"references-count":40,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["54054"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-54054-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,20]]},"assertion":[{"value":"29 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"22885"}}