{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T10:18:48Z","timestamp":1783073928530,"version":"3.54.6"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T00:00:00Z","timestamp":1780358400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T00:00:00Z","timestamp":1780444800000},"content-version":"vor","delay-in-days":1,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002839","name":"Charit\u00e9 - Universit\u00e4tsmedizin Berlin","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100002839","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Automated segmentation of cardiac magnetic resonance (CMR) imaging is integrated into clinical workflows, yet comparative performance across vendor AI solutions remains insufficiently characterized. This study assessed three models (two commercial, one research) for short-axis cine segmentation in a diverse cohort of 346 cases, including dilated cardiomyopathy (DCM), left ventricular hypertrophy (LVH), healthy volunteers, and other cardiac diseases. Clinical parameter agreement between AI-derived and expert-derived ventricular volumes and left ventricular mass (LVM) was evaluated using correlations and mean differences, segmentation agreement with Dice coefficient, and slice detection was characterized with false positive and negative rates (FPR\/FNR). Papillary muscle (PM) inclusion was examined with subgroup analyses. AI-derived clinical parameters agreed strongly with expert measurements (r\u2009&gt;\u20090.8). Nevertheless, inter-model biases included differing ventricular volume estimates. Midventricular segmentation was reliable (Dice\u2009&gt;\u200980%), whereas apical slices were poor (Dice\u2009&lt;\u200965%) with minor area impact (&lt;\u20091cm\n                    <jats:sup>2<\/jats:sup>\n                    ). Basal slice detection varied substantially, with AI1 and AI2 over- and AI3 under-detecting slices (e.g. RV FPR: AI1 24%, AI2 14%, AI3 FNR: 32%), producing large area differences. Due to PM exclusion AI2 overestimated volumes and underestimated LVM \u2013 particularly LVH-cases. While AI-expert agreement is high, AI solutions are not interchangeable and produce clinically relevant differences to experts across cardiac regions and disease groups.\n                  <\/jats:p>","DOI":"10.1038\/s41598-026-54182-z","type":"journal-article","created":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T14:26:54Z","timestamp":1780410414000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A comparison of vendor artificial intelligence solutions for automated post-processing of short-axis cine images in cardiovascular magnetic resonance imaging"],"prefix":"10.1038","volume":"16","author":[{"given":"Thomas","family":"Hadler","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clemens","family":"Ammann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hadil","family":"Saad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yashraj","family":"Bhoyroo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jana","family":"Veit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Teodora","family":"Chitiboi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jens","family":"Wetzl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Geppert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeanette","family":"Schulz-Menger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,2]]},"reference":[{"key":"54182_CR1","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1186\/s12968-020-00610-6","volume":"22","author":"J Schulz-Menger","year":"2020","unstructured":"Schulz-Menger, J. et al. Standardized image interpretation and post-processing in cardiovascular magnetic resonance - 2020 update\u202f: Society for Cardiovascular Magnetic Resonance (SCMR): Board of Trustees Task Force on Standardized Post-Processing. J Cardiovasc Magn Reson 22, 19 (2020).","journal-title":"J Cardiovasc Magn Reson"},{"key":"54182_CR2","doi-asserted-by":"publisher","DOI":"10.1186\/s12968-017-0385-z","volume":"19","author":"F von Knobelsdorff-Brenkenhoff","year":"2017","unstructured":"von Knobelsdorff-Brenkenhoff, F., Pilz, G. & Schulz-Menger, J. Representation of cardiovascular magnetic resonance in the AHA \/ ACC guidelines. J. Cardiovasc. Magn. Reson. 19, 70 (2017).","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"54182_CR3","doi-asserted-by":"publisher","DOI":"10.1186\/s12968-015-0170-9","volume":"17","author":"A Suinesiaputra","year":"2015","unstructured":"Suinesiaputra, A. et al. Quantification of LV function and mass by cardiovascular magnetic resonance: Multi-center variability and consensus contours. J. Cardiovasc. Magn. Reson. 17, 63 (2015).","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"54182_CR4","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2020.00025","volume":"7","author":"C Chen","year":"2020","unstructured":"Chen, C. et al. Deep learning for cardiac image segmentation: A review. Front. Cardiovasc. Med. 7, 25 (2020).","journal-title":"Front. Cardiovasc. Med."},{"key":"54182_CR5","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1007\/s12471-016-0805-y","volume":"24","author":"DHF Gommans","year":"2016","unstructured":"Gommans, D. H. F. et al. Impact of the papillary muscles on cardiac magnetic resonance image analysis of important left ventricular parameters in hypertrophic cardiomyopathy. Neth Heart J 24, 326\u2013331 (2016).","journal-title":"Neth Heart J"},{"key":"54182_CR6","doi-asserted-by":"crossref","unstructured":"Long, J., Shelhamer, E. & Darrell, T. Fully Convolutional Networks for Semantic Segmentation. Preprint at http:\/\/arxiv.org\/abs\/1411.4038 (2015).","DOI":"10.1109\/CVPR.2015.7298965"},{"key":"54182_CR7","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1186\/s12968-018-0471-x","volume":"20","author":"W Bai","year":"2018","unstructured":"Bai, W. et al. Automated cardiovascular magnetic resonance image analysis with fully convolutional networks. J. Cardiovasc. Magn. Reson. 20, 65 (2018).","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"54182_CR8","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1186\/s12968-019-0575-y","volume":"21","author":"T Leiner","year":"2019","unstructured":"Leiner, T. et al. Machine learning in cardiovascular magnetic resonance: basic concepts and applications. J Cardiovasc Magn Reson 21, 61 (2019).","journal-title":"J Cardiovasc Magn Reson"},{"key":"54182_CR9","doi-asserted-by":"publisher","first-page":"3541","DOI":"10.1109\/JBHI.2021.3064353","volume":"25","author":"W Xue","year":"2021","unstructured":"Xue, W. et al. Left Ventricle Quantification Challenge: A Comprehensive Comparison and Evaluation of Segmentation and Regression for Mid-ventricular Short-axis Cardiac MR Data. IEEE J Biomed Health Inform 25, 3541\u20133553 (2021).","journal-title":"IEEE J Biomed Health Inform"},{"key":"54182_CR10","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.media.2014.10.004","volume":"19","author":"C Petitjean","year":"2015","unstructured":"Petitjean, C. et al. Right ventricle segmentation from cardiac MRI: A collation study. Med. Image Anal. 19, 187\u2013202 (2015).","journal-title":"Med. Image Anal."},{"key":"54182_CR11","doi-asserted-by":"publisher","first-page":"2514","DOI":"10.1109\/TMI.2018.2837502","volume":"37","author":"O Bernard","year":"2018","unstructured":"Bernard, O. et al. Deep learning techniques for automatic MRI cardiac multi-structures segmentation and diagnosis: Is the problem solved?. IEEE Trans. Med. Imaging. 37, 2514\u20132525 (2018).","journal-title":"IEEE Trans. Med. Imaging."},{"key":"54182_CR12","doi-asserted-by":"publisher","first-page":"3543","DOI":"10.1109\/TMI.2021.3090082","volume":"40","author":"VM Campello","year":"2021","unstructured":"Campello, V. M. et al. Multi-Centre, Multi-Vendor and Multi-Disease Cardiac Segmentation: The M&Ms Challenge. IEEE Trans. Med. Imaging 40, 3543\u20133554 (2021).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"54182_CR13","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2023.1118499","author":"C Ammann","year":"2023","unstructured":"Ammann, C., Hadler, T., Gr\u00f6schel, J., Kolbitsch, C. & Schulz-Menger, J. Multilevel comparison of deep learning models for function quantification in cardiovascular magnetic resonance: On the redundancy of architectural variations. Front. Cardiovasc. Med. https:\/\/doi.org\/10.3389\/fcvm.2023.1118499 (2023).","journal-title":"Front. Cardiovasc. Med."},{"key":"54182_CR14","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1007\/978-3-030-68107-4_24","volume-title":"Statistical Atlases and Computational Models of the Heart. M&Ms and EMIDEC Challenges","author":"PM Full","year":"2021","unstructured":"Full, P. M. et al. Studying robustness of semantic segmentation under domain shift in cardiac MRI. In Statistical Atlases and Computational Models of the Heart. M&Ms and EMIDEC Challenges Vol. 12592 (ed. Puyol Anton, E.) 238\u2013249 (Springer International Publishing, 2021)."},{"key":"54182_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2023.107912","volume":"170","author":"S Kumari","year":"2024","unstructured":"Kumari, S. & Singh, P. Deep learning for unsupervised domain adaptation in medical imaging: Recent advancements and future perspectives. Comput. Biol. Med. 170, 107912 (2024).","journal-title":"Comput. Biol. Med."},{"key":"54182_CR16","unstructured":"Ammann, C. et al. Cardiometry: Open-Source, Precise and Efficient Computation of Quantitative Parameters in Cardiovascular Magnetic Resonance. (2025)."},{"key":"54182_CR17","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-10464-w","volume":"12","author":"T Hadler","year":"2022","unstructured":"Hadler, T. et al. Introduction of Lazy Luna an automatic software-driven multilevel comparison of ventricular function quantification in cardiovascular magnetic resonance imaging. Sci Rep 12, 6629 (2022).","journal-title":"Sci Rep"},{"key":"54182_CR18","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2023.107615","volume":"238","author":"T Hadler","year":"2023","unstructured":"Hadler, T. et al. Lazy Luna: Extendible software for multilevel reader comparison in cardiovascular magnetic resonance imaging. Comput. Methods Programs Biomed. 238, 107615 (2023).","journal-title":"Comput. Methods Programs Biomed."},{"key":"54182_CR19","doi-asserted-by":"publisher","DOI":"10.1007\/s10278-025-01437-2","author":"P Reisdorf","year":"2025","unstructured":"Reisdorf, P. et al. Lumos: Software for multi-level multi-reader comparison of cardiovascular magnetic resonance Late Gadolinium Enhancement scar quantification. J Digit Imaging. Inform. med. https:\/\/doi.org\/10.1007\/s10278-025-01437-2 (2025).","journal-title":"J Digit Imaging. Inform. med."},{"key":"54182_CR20","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0323371","volume":"20","author":"T Hadler","year":"2025","unstructured":"Hadler, T. et al. Verity plots: A novel method of visualizing reliability assessments of artificial intelligence methods in quantitative cardiovascular magnetic resonance. PLoS ONE 20, e0323371 (2025).","journal-title":"PLoS ONE"},{"key":"54182_CR21","doi-asserted-by":"crossref","unstructured":"Marterer, R., Tschauner, S., Grangl, G., Kalmar, P. & Sorantin, E. Impact of Basal Plane Selection on the Evaluation of Cardiac Performance Parameters with Cardiac Magnetic Resonance Imaging in Patients with Corrected Tetralogy of Fallot: A Systematic Approach. https:\/\/brieflands.com\/articles\/ijradiology-74219#abstract (2019).","DOI":"10.5812\/iranjradiol.74219"},{"key":"54182_CR22","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1016\/j.acra.2012.03.022","volume":"19","author":"J Caudron","year":"2012","unstructured":"Caudron, J. et al. Cardiac MRI assessment of right ventricular function in acquired heart disease: Factors of variability. Acad Radiol 19, 991\u20131002 (2012).","journal-title":"Acad Radiol"},{"key":"54182_CR23","doi-asserted-by":"publisher","first-page":"105","DOI":"10.3389\/fcvm.2020.00105","volume":"7","author":"C Chen","year":"2020","unstructured":"Chen, C. et al. Improving the Generalizability of Convolutional Neural Network-Based Segmentation on CMR Images. Front Cardiovasc Med 7, 105 (2020).","journal-title":"Front Cardiovasc Med"},{"key":"54182_CR24","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.3.3.034004","volume":"3","author":"M Paknezhad","year":"2016","unstructured":"Paknezhad, M., Marchesseau, S. & Brown, M. S. Automatic basal slice detection for cardiac analysis. Journal of Medical Imaging 3, 034004 (2016).","journal-title":"Journal of Medical Imaging"},{"key":"54182_CR25","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1007\/s10554-009-9501-y","volume":"26","author":"SE Luijnenburg","year":"2010","unstructured":"Luijnenburg, S. E. et al. Intra-observer and interobserver variability of biventricular function, volumes and mass in patients with congenital heart disease measured by CMR imaging. Int J Cardiovasc Imaging 26, 57\u201364 (2010).","journal-title":"Int J Cardiovasc Imaging"},{"key":"54182_CR26","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1007\/s00392-018-1371-7","volume":"108","author":"JH Riffel","year":"2019","unstructured":"Riffel, J. H. et al. Cardiovascular magnetic resonance of cardiac morphology and function: Impact of different strategies of contour drawing and indexing. Clin Res Cardiol 108, 411\u2013429 (2019).","journal-title":"Clin Res Cardiol"},{"key":"54182_CR27","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-54164-z","volume":"14","author":"M Schilling","year":"2024","unstructured":"Schilling, M., Unterberg-Buchwald, C., Lotz, J. & Uecker, M. Assessment of deep learning segmentation for real-time free-breathing cardiac magnetic resonance imaging at rest and under exercise stress. Sci. Rep. 14, 3754 (2024).","journal-title":"Sci. Rep."},{"key":"54182_CR28","doi-asserted-by":"publisher","DOI":"10.1186\/1532-429X-13-40","volume":"13","author":"H Childs","year":"2011","unstructured":"Childs, H. et al. Comparison of long and short axis quantification of left ventricular volume parameters by cardiovascular magnetic resonance, with ex-vivo validation. J. Cardiovasc. Magn. Reson. 13, 40 (2011).","journal-title":"J. Cardiovasc. Magn. Reson."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54182-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54182-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54182-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T09:45:07Z","timestamp":1783071907000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54182-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,2]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["54182"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-54182-z","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,2]]},"assertion":[{"value":"14 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"TC, JW, and CG were employees of Siemens Healthineers at the time of the study and contributed to study design but were not involved in data analysis or interpretation. Apart from these affiliations, the authors declare no other competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"17154"}}