{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T15:04:27Z","timestamp":1786115067993,"version":"build-2736575974"},"reference-count":60,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T00:00:00Z","timestamp":1779840000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T00:00:00Z","timestamp":1785974400000},"content-version":"vor","delay-in-days":71,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This Monte Carlo (MC) study investigated theoretically achievable detection limits of gold nanoparticles (GNPs) present within a small-animal-sized phantom during benchtop x-ray fluorescence (XRF) computed tomography (XFCT) imaging based on the detection of gold K-shell XRF photons emitted from GNPs. The MC model was based on our experimental benchtop cone-beam XFCT system, reflecting an anticipated upgrade adopting a larger field-of-view pixelated cadmium-telluride detector that fully covers a 3\u00a0cm-diameter PMMA phantom including three 6\u00a0mm-diameter cylindrical holes filled with various concentrations of GNPs. It was validated by comparing the MC results with experimental data acquired under identical conditions using a 1.8\u00a0mm-Sn-filtered 125 kVp beam. The MC simulations were then extended to investigate GNP detection limits across a range of x-ray doses, GNP concentrations, and incident x-ray beam spectra. Assuming an ideal detector, the GNP detection limits of 104\u2013140 ppm at 1.775\u00a0cGy and 69\u201388 ppm at 3.55\u00a0cGy were achievable with the 1.8\u00a0mm Sn-filtered 125 kVp beam. When hypothetical monochromatic beams with their energy above the gold K-edge were employed, the GNP detection limits were improved by up to three-folds at a given dose (e.g., 34\u201370 ppm at 1.775\u00a0cGy with the 85\u00a0keV beam).<\/jats:p>","DOI":"10.1038\/s41598-026-54278-6","type":"journal-article","created":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T15:14:11Z","timestamp":1779894851000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Monte carlo study of detection limit for gold nanoparticles within small animal sized object during benchtop X-ray fluorescence computed tomography"],"prefix":"10.1038","volume":"16","author":[{"given":"Neerajan","family":"Nepal","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandun","family":"Jayarathna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang Hyun","family":"Cho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,27]]},"reference":[{"key":"54278_CR1","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1016\/0168-9002(89)90802-4","volume":"277","author":"R Cesareo","year":"1989","unstructured":"Cesareo, R. & Mascarenhas, S. A new tomographic device based on the detection of fluorescent x-rays. Nucl. Instrum. Methods Phys. Res. A. 277, 669\u2013672 (1989).","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"54278_CR2","doi-asserted-by":"publisher","first-page":"2736","DOI":"10.1109\/23.901180","volume":"47","author":"A Simionovici","year":"2000","unstructured":"Simionovici, A. et al. High-resolution X-ray fluorescence microtomography of homogeneous samples. IEEE Trans. Nucl. Sci. 47, 2736\u20132740 (2000).","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"54278_CR3","doi-asserted-by":"publisher","first-page":"1318","DOI":"10.1016\/S0168-9002(01)00654-4","volume":"467\u2013468","author":"T Takeda","year":"2001","unstructured":"Takeda, T. et al. Iodine imaging in thyroid by fluorescent X-ray CT with 0.05\u00a0mm spatial resolution. Nucl. Instrum. Methods Phys. Res. A. 467\u2013468, 1318\u20131321 (2001).","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"54278_CR4","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1107\/S0909049508031853","volume":"16","author":"T Takeda","year":"2009","unstructured":"Takeda, T. et al. X-ray fluorescent CT imaging of cerebral uptake of stable-iodine perfusion agent iodoamphetamine analog IMP in mice. J. Synchrotron Radiat. 16, 57\u201362 (2009).","journal-title":"J. Synchrotron Radiat."},{"key":"54278_CR5","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1109\/23.659557","volume":"45","author":"GF Rust","year":"1998","unstructured":"Rust, G. F. & Weigelt, J. X-ray fluorescent computer tomography with synchrotron radiation. IEEE Trans. Nucl. Sci. 45, 75\u201388 (1998).","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"54278_CR6","doi-asserted-by":"publisher","first-page":"49912","DOI":"10.1109\/ACCESS.2021.3069368","volume":"9","author":"S Jayarathna","year":"2021","unstructured":"Jayarathna, S. et al. Characterization of a pixelated cadmium telluride detector system using a polychromatic X-ray source and gold nanoparticle-loaded phantoms for benchtop X-ray fluorescence imaging. IEEE Access. 9, 49912\u201349919 (2021).","journal-title":"IEEE Access."},{"key":"54278_CR7","doi-asserted-by":"publisher","first-page":"105074","DOI":"10.1109\/ACCESS.2022.3210590","volume":"10","author":"S Jayarathna","year":"2022","unstructured":"Jayarathna, S., Moktan, H. & Cho, S. H. Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography. IEEE Access. 10, 105074\u2013105083 (2022).","journal-title":"IEEE Access."},{"key":"54278_CR8","doi-asserted-by":"crossref","unstructured":"Manohar, N., Reynoso, F. J., Diagaradjane, P., Krishnan, S. & Cho, S. H. Quantitative imaging of gold nanoparticle distribution in a tumor-bearing mouse using benchtop x-ray fluorescence computed tomography. Sci. Rep. 6, 22079 (2016).","DOI":"10.1038\/srep22079"},{"key":"54278_CR9","doi-asserted-by":"crossref","unstructured":"Gr\u00fcner, F. et al. Localising functionalised gold-nanoparticles in murine spinal cords by X-ray fluorescence imaging and background-reduction through spatial filtering for human-sized objects. Sci. Rep. 8, 16561 (2018).","DOI":"10.1038\/s41598-018-34925-3"},{"key":"54278_CR10","doi-asserted-by":"crossref","unstructured":"K\u00f6rnig, C. et al. In-situ x-ray fluorescence imaging of the endogenous iodine distribution in murine thyroids. Sci. Rep. 12, 2903 (2022).","DOI":"10.1038\/s41598-022-06786-4"},{"key":"54278_CR11","doi-asserted-by":"crossref","unstructured":"Staufer, T. et al. Enabling X-ray fluorescence imaging for in vivo immune cell tracking. Sci. Rep. 13, 11505 (2023).","DOI":"10.1038\/s41598-023-38536-5"},{"key":"54278_CR12","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1088\/0031-9155\/55\/3\/007","volume":"55","author":"SK Cheong","year":"2010","unstructured":"Cheong, S. K. et al. X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp x-rays. Phys. Med. Biol. 55, 647\u2013662 (2010).","journal-title":"Phys. Med. Biol."},{"key":"54278_CR13","doi-asserted-by":"publisher","first-page":"526","DOI":"10.1109\/TMI.2019.2932014","volume":"39","author":"S Jung","year":"2020","unstructured":"Jung, S. et al. Dynamic in Vivo X-ray Fluorescence Imaging of Gold in Living Mice Exposed to Gold Nanoparticles. IEEE Trans. Med. Imaging. 39, 526\u2013533 (2020).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"54278_CR14","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1016\/j.ijrobp.2021.04.032","volume":"111","author":"D Hara","year":"2021","unstructured":"Hara, D. et al. Prostate Cancer Targeted X-Ray Fluorescence Imaging via Gold Nanoparticles Functionalized With Prostate-Specific Membrane Antigen (PSMA). Int. J. Radiat. Oncol. Biol. Phys. 111, 220\u2013232 (2021).","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"54278_CR15","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1002\/mp.16070","volume":"50","author":"T Kim","year":"2023","unstructured":"Kim, T. et al. Dual imaging modality of fluorescence and transmission X-rays for gold nanoparticle-injected living mice. Med. Phys. 50, 529\u2013539 (2023).","journal-title":"Med. Phys."},{"key":"54278_CR16","doi-asserted-by":"crossref","unstructured":"Zhang, S. et al. Quantitative imaging of gd nanoparticles in mice using benchtop cone-beam X-ray fluorescence computed tomography system. Int J. Mol. Sci 20, 2315 (2019).","DOI":"10.3390\/ijms20092315"},{"key":"54278_CR17","doi-asserted-by":"crossref","unstructured":"Li, L., Zhang, S., Zhang, W. & Lu, H. Full-field in vivo imaging of nanoparticles using benchtop cone-beam XFCT system with pixelated photon counting detector. Phys. Med. Biol. 68, 035020 (2023).","DOI":"10.1088\/1361-6560\/acb3aa"},{"key":"54278_CR18","doi-asserted-by":"crossref","unstructured":"Larsson, J. C. et al. High-spatial-resolution x-ray fluorescence tomography with spectrally matched nanoparticles. Phys. Med. Biol. 63, 164001 (2018).","DOI":"10.1088\/1361-6560\/aad51e"},{"key":"54278_CR19","doi-asserted-by":"publisher","first-page":"3910","DOI":"10.1109\/TMI.2020.3007165","volume":"39","author":"K Shaker","year":"2020","unstructured":"Shaker, K. et al. Longitudinal In-Vivo X-Ray Fluorescence Computed Tomography with Molybdenum Nanoparticles. IEEE Trans. Med. Imaging. 39, 3910\u20133919 (2020).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"54278_CR20","doi-asserted-by":"publisher","first-page":"17404","DOI":"10.1039\/D4NR02793K","volume":"16","author":"GM Saladino","year":"2024","unstructured":"Saladino, G. M., Chao, P. H., Brodin, B., Li, S. D. & Hertz, H. M. Liposome biodistribution mapping with in vivo X-ray fluorescence imaging. Nanoscale 16, 17404\u201317411 (2024).","journal-title":"Nanoscale"},{"key":"54278_CR21","unstructured":"Sokolov, K. et al. Real-Time Vital Optical Imaging of Precancer Using Anti-Epidermal Growth Factor Receptor Antibodies Conjugated to Gold Nanoparticles. Cancer Res. 63, 1999 (1999)."},{"key":"54278_CR22","doi-asserted-by":"crossref","unstructured":"Hirsch, L. R. et al. Nanoshell-mediated near-infrared thermal therapy of tumors under magnetic resonance guidance. In Proceedings of the National Academy of Sciences Vol. 100, 13549\u201313554 (2003).","DOI":"10.1073\/pnas.2232479100"},{"key":"54278_CR23","doi-asserted-by":"crossref","unstructured":"Hainfeld, J. F., Slatkin, D. N. & Smilowitz, H. M. The use of gold nanoparticles to enhance radiotherapy in mice. Phys. Med. Biol. 49, N309 (2004).","DOI":"10.1088\/0031-9155\/49\/18\/N03"},{"key":"54278_CR24","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.mibio.2004.06.002","volume":"6","author":"JA Copland","year":"2004","unstructured":"Copland, J. A. et al. Bioconjugated gold nanoparticles as a molecular based contrast agent: implications for imaging of deep tumors using optoacoustic tomography. Mol. Imaging Biol. 6, 341\u2013349 (2004).","journal-title":"Mol. Imaging Biol."},{"key":"54278_CR25","doi-asserted-by":"crossref","unstructured":"Cho, S. H. Estimation of tumour dose enhancement due to gold nanoparticles during typical radiation treatments: A preliminary Monte Carlo study. Phys. Med. Biol. 50, N163 (2005).","DOI":"10.1088\/0031-9155\/50\/15\/N01"},{"key":"54278_CR26","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1021\/nl050074e","volume":"5","author":"IH El-Sayed","year":"2005","unstructured":"El-Sayed, I. H., Huang, X. & El-Sayed, M. A. Surface Plasmon Resonance Scattering and Absorption of anti-EGFR Antibody Conjugated Gold Nanoparticles in Cancer Diagnostics: Applications in Oral Cancer. Nano Lett. 5, 829\u2013834 (2005).","journal-title":"Nano Lett."},{"key":"54278_CR27","doi-asserted-by":"crossref","unstructured":"Thakor, A. S., Jokerst, J., Zavaleta, C., Massoud, T. F. & Gambhir, S. S. Gold nanoparticles: A revival in precious metal administration to patients. Nano Lett. 11, 4029\u20134036 (2011).","DOI":"10.1021\/nl202559p"},{"key":"54278_CR28","doi-asserted-by":"crossref","unstructured":"Schuemann, J. et al. Roadmap to clinical use of gold nanoparticles for radiation sensitization. Int. J. Radiat. Oncol. Biol. Phys. 94, 189\u2013205 (2016).","DOI":"10.1016\/j.ijrobp.2015.09.032"},{"key":"54278_CR29","doi-asserted-by":"crossref","unstructured":"Liu, C. H. & Grodzinski, P. Nanotechnology for cancer imaging: Advances, challenges, and clinical opportunities. Radiol. Imaging Cancer 3, e200052 (2021).","DOI":"10.1148\/rycan.2021200052"},{"key":"54278_CR30","doi-asserted-by":"crossref","unstructured":"Schuemann, J. et al. Roadmap for metal nanoparticles in radiation therapy: Current status, translational challenges, and future directions. Phys. Med. Biol. 65, 21RM02 (2020).","DOI":"10.1088\/1361-6560\/ab9159"},{"key":"54278_CR31","doi-asserted-by":"publisher","first-page":"4652","DOI":"10.1002\/mp.13138","volume":"45","author":"N Manohar","year":"2018","unstructured":"Manohar, N., Reynoso, F. J., Cho, S. H. & Technical Note A benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system with a high-power x-ray source and transmission CT imaging capability. Med. Phys. 45, 4652\u20134659 (2018).","journal-title":"Med. Phys."},{"key":"54278_CR32","doi-asserted-by":"crossref","unstructured":"Jones, B. L., Manohar, N., Reynoso, F., Karellas, A. & Cho, S. H. Experimental demonstration of benchtop x-ray fluorescence computed tomography (XFCT) of gold nanoparticle-loaded objects using lead- and tin-filtered polychromatic cone-beams. Phys. Med. Biol. 57, N457-N467 (2012).","DOI":"10.1088\/0031-9155\/57\/23\/N457"},{"key":"54278_CR33","doi-asserted-by":"publisher","first-page":"2483","DOI":"10.1109\/TMI.2018.2836973","volume":"37","author":"MF Ahmed","year":"2018","unstructured":"Ahmed, M. F., Yasar, S. & Cho, S. H. A Monte Carlo Model of a Benchtop X-Ray Fluorescence Computed Tomography System and Its Application to Validate a Deconvolution-Based X-Ray Fluorescence Signal Extraction Method. IEEE Trans. Med. Imaging. 37, 2483\u20132492 (2018).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"54278_CR34","doi-asserted-by":"crossref","unstructured":"Jowitt, L. et al. HEXITEC 2 2 tiled hard X-ray spectroscopic imaging detector system. J. Instrum. 17, P01012 (2022).","DOI":"10.1088\/1748-0221\/17\/01\/P01012"},{"key":"54278_CR35","unstructured":"Jayarathna, S., Moktan, H. & Cho, S. H. Comment on \u2018Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography\u2019. https:\/\/ieeexplore.ieee.org\/document\/9905602#comment-6651181644"},{"key":"54278_CR36","doi-asserted-by":"crossref","unstructured":"Manohar, N., Jones, B. L. & Cho, S. H. Improving x-ray fluorescence signal for benchtop polychromatic cone-beam x-ray fluorescence computed tomography by incident x-ray spectrum optimization: A Monte Carlo study. Med. Phys. 41, 101906 (2014).","DOI":"10.1118\/1.4895004"},{"key":"54278_CR37","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1109\/TMI.2014.2305101","volume":"33","author":"M Ahmad","year":"2014","unstructured":"Ahmad, M., Bazalova, M., Xiang, L. & Xing, L. Order of magnitude sensitivity increase in X-ray fluorescence computed tomography (XFCT) imaging with an optimized spectro-spatial detector configuration: Theory and simulation. IEEE Trans. Med. Imaging. 33, 1119\u20131128 (2014).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"54278_CR38","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/S0168-9002(03)01368-8","volume":"506","author":"S Agostinelli","year":"2003","unstructured":"Agostinelli, S. et al. GEANT4 - A simulation toolkit. Nucl. Instrum. Methods Phys. Res. A. 506, 250\u2013303 (2003).","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"54278_CR39","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1109\/TNS.2006.869826","volume":"53","author":"J Allison","year":"2006","unstructured":"Allison, J. et al. Geant4 developments and applications. IEEE Trans. Nucl. Sci. 53, 270\u2013278 (2006).","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"54278_CR40","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/j.anucene.2014.08.021","volume":"82","author":"M Asai","year":"2015","unstructured":"Asai, M., Dotti, A., Verderi, M. & Wright, D. H. Recent developments in Geant4. Ann. Nucl. Energy. 82, 19\u201328 (2015).","journal-title":"Ann. Nucl. Energy"},{"key":"54278_CR41","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/j.nima.2016.06.125","volume":"835","author":"J Allison","year":"2016","unstructured":"Allison, J. et al. Recent developments in GEANT4. Nucl. Instrum. Methods Phys. Res. A. 835, 186\u2013225 (2016).","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"54278_CR42","doi-asserted-by":"crossref","unstructured":"Seller, P. et al. Pixellated Cd(Zn)Te high-energy X-ray instrument. J. Instrum. 6, C12009 (2011).","DOI":"10.1088\/1748-0221\/6\/12\/C12009"},{"key":"54278_CR43","doi-asserted-by":"publisher","first-page":"3630","DOI":"10.1002\/mp.14945","volume":"48","author":"G Poludniowski","year":"2021","unstructured":"Poludniowski, G., Omar, A., Bujila, R. & Andreo, P. Technical Note: SpekPy v2.0\u2014a software toolkit for modeling x-ray tube spectra. Med. Phys. 48, 3630\u20133637 (2021).","journal-title":"Med. Phys."},{"key":"54278_CR44","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.ejmp.2020.04.026","volume":"75","author":"R Bujila","year":"2020","unstructured":"Bujila, R., Omar, A. & Poludniowski, G. A validation of SpekPy: A software toolkit for modelling X-ray tube spectra. Physica Med. 75, 44\u201354 (2020).","journal-title":"Physica Med."},{"key":"54278_CR45","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/S0168-9002(97)00048-X","volume":"389","author":"R Brun","year":"1997","unstructured":"Brun, R. & Rademakers, F. ROOT \u2014 An object oriented data analysis framework. Nucl. Instrum. Methods Phys. Res. A. 389, 81\u201386 (1997).","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"54278_CR46","doi-asserted-by":"crossref","unstructured":"Manohar, N., Reynoso, F. J. & Cho, S. H. Experimental demonstration of direct L-shell x-ray fluorescence imaging of gold nanoparticles using a benchtop x-ray source. Med. Phys. 40, 080702 (2013).","DOI":"10.1118\/1.4816297"},{"key":"54278_CR47","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/0883-2889(89)90200-1","volume":"40","author":"C Bui","year":"1989","unstructured":"Bui, C., Confalonieri, L. & Milazzo, M. Use of Compton scattering in quantitative XRF analysis of stained glass. Appl. Radiat. Isot. 40, 375\u2013380 (1989).","journal-title":"Appl. Radiat. Isot."},{"key":"54278_CR48","doi-asserted-by":"publisher","first-page":"1306","DOI":"10.1021\/ac60140a001","volume":"30","author":"G Andermann","year":"1958","unstructured":"Andermann, G. & Kemp, J. W. Scattered X-rays as internal standards in X-ray emission spectroscopy. Anal. Chem. 30, 1306\u20131309 (1958).","journal-title":"Anal. Chem."},{"key":"54278_CR49","first-page":"306","volume":"8","author":"K Lange","year":"1984","unstructured":"Lange, K. & Carson, R. EM reconstruction algorithms for emission and transmission tomography. J. Comput. Assist. Tomogr. 8, 306\u2013316 (1984).","journal-title":"J. Comput. Assist. Tomogr"},{"key":"54278_CR50","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1109\/TMI.1982.4307558","volume":"1","author":"LA Shepp","year":"2007","unstructured":"Shepp, L. A. & Vardi, Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans. Med. Imaging. 1, 113\u2013122 (2007).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"54278_CR51","doi-asserted-by":"crossref","unstructured":"Rose, A. Vision: human and electronic. In Applied Solid State Physics 79\u2013160 (Springer, 1973).","DOI":"10.1007\/978-1-4684-1854-5_4"},{"key":"54278_CR52","doi-asserted-by":"crossref","unstructured":"Moktan, H., Jayarathna, S. & Cho, S. H. Sensitivity enhancement of an experimental benchtop X-ray fluorescence imaging system by deploying a single crystal cadmium telluride detector system optimized for high flux X-ray operations. Nucl. Instrum. Methods Phys. Res. A 1025, 166198 (2022).","DOI":"10.1016\/j.nima.2021.166198"},{"key":"54278_CR53","doi-asserted-by":"crossref","unstructured":"Kaphle, A., Jayarathna, S. & Cho, S. H. Deep learning based rapid X-ray fluorescence signal extraction and image reconstruction for preclinical benchtop X-ray fluorescence computed tomography applications. Sci. Rep. 15, 19588 (2025).","DOI":"10.1038\/s41598-025-03900-0"},{"key":"54278_CR54","doi-asserted-by":"publisher","first-page":"3045","DOI":"10.1088\/0031-9155\/55\/11\/004","volume":"55","author":"JF Hainfeld","year":"2010","unstructured":"Hainfeld, J. F. et al. Gold nanoparticles enhance the radiation therapy of a murine squamous cell carcinoma. Phys. Med. Biol. 55, 3045\u20133059 (2010).","journal-title":"Phys. Med. Biol."},{"key":"54278_CR55","doi-asserted-by":"crossref","unstructured":"Deng, L. et al. A detector\u2019s eye view (DEV)-based OSEM algorithm for benchtop x-ray fluorescence computed tomography (XFCT) image reconstruction. Phys. Med. Biol. 64, 08NT02 (2019).","DOI":"10.1088\/1361-6560\/ab0e9d"},{"key":"54278_CR56","doi-asserted-by":"publisher","first-page":"2761","DOI":"10.2147\/IJN.S301182","volume":"16","author":"P Zhang","year":"2021","unstructured":"Zhang, P. et al. Nbtxr3 radiotherapy-activated functionalized hafnium oxide nanoparticles show efficient antitumor effects across a large panel of human cancer models. Int. J. Nanomed. 16, 2761\u20132773 (2021).","journal-title":"Int. J. Nanomed."},{"key":"54278_CR57","doi-asserted-by":"publisher","first-page":"2735","DOI":"10.1109\/TMI.2019.2912137","volume":"38","author":"CAS Dunning","year":"2019","unstructured":"Dunning, C. A. S. & Bazalova-Carter, M. X-Ray Fluorescence Computed Tomography Induced by Photon, Electron, and Proton Beams. IEEE Trans. Med. Imaging. 38, 2735\u20132743 (2019).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"54278_CR58","doi-asserted-by":"crossref","unstructured":"Grigorieva, I. G. & Antonov, A. A. HOPG as powerful x-ray optics. X-Ray Spectrom. 32, 64\u201368 (2003).","DOI":"10.1002\/xrs.617"},{"key":"54278_CR59","doi-asserted-by":"publisher","first-page":"2107","DOI":"10.1118\/1.3125137","volume":"36","author":"G Jost","year":"2009","unstructured":"Jost, G. et al. Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography. Med. Phys. 36, 2107\u20132117 (2009).","journal-title":"Med. Phys."},{"key":"54278_CR60","doi-asserted-by":"crossref","unstructured":"Bartkoski, D. A. et al. Analysis of a novel X-ray lens for converging beam radiotherapy. Sci. Rep. 11, 19180 (2021).","DOI":"10.1038\/s41598-021-98888-8"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54278-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54278-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54278-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T00:06:30Z","timestamp":1785974790000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54278-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,27]]},"references-count":60,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["54278"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-54278-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,27]]},"assertion":[{"value":"23 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"24299"}}