{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:35:05Z","timestamp":1786120505253,"version":"build-2736575974"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T00:00:00Z","timestamp":1786060800000},"content-version":"vor","delay-in-days":71,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-54365-8","type":"journal-article","created":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T08:14:21Z","timestamp":1779956061000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Unintended tripping of healthy parallel lines during single-line-to-ground faults: field evidence and mitigation"],"prefix":"10.1038","volume":"16","author":[{"given":"Farhad Aghajanian","family":"Sabagh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Farzad","family":"Hajimohammadi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bahador","family":"Fani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Iman","family":"Sadeghkhani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,28]]},"reference":[{"key":"54365_CR1","volume-title":"Power system relaying","author":"SH Horowitz","year":"2022","unstructured":"Horowitz, S. H., Phadke, A. G. & Henville, C. F. Power system relaying (John Wiley & Sons, 2022)."},{"key":"54365_CR2","volume-title":"Numerical distance protection: principles and applications","author":"G Ziegler","year":"2011","unstructured":"Ziegler, G. Numerical distance protection: principles and applications (John Wiley & Sons, 2011)."},{"key":"54365_CR3","doi-asserted-by":"publisher","DOI":"10.1201\/9781420017847","volume-title":"Protective relaying: principles and applications","author":"JL Blackburn","year":"2006","unstructured":"Blackburn, J. L. & Domin, T. J. Protective relaying: principles and applications (CRC Press, 2006)."},{"key":"54365_CR4","volume-title":"Power system analysis and design","author":"JD Glover","year":"2012","unstructured":"Glover, J. D., Sarma, M. S., Overbye, T. J. & Padhy, N. Power system analysis and design Vol. vol. 2008 (Cengage Learning, 2012)."},{"issue":"4","key":"54365_CR5","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1049\/gtd2.12711","volume":"17","author":"B Taheri","year":"2023","unstructured":"Taheri, B., Hosseini, S. A. & Salehimehr, S. An overview of power swing detection methods in distance relays and the factors involved. IET Generation, Transmission & Distribution 17(4), 743\u2013761 (2023).","journal-title":"IET Generation, Transmission & Distribution"},{"issue":"1","key":"54365_CR6","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1515\/ijeeps-2015-0109","volume":"17","author":"UJ Patel","year":"2016","unstructured":"Patel, U. J., Chothani, N. G. & Bhatt, P. J. Distance relaying with power swing detection based on voltage and reactive power sensitivity. International Journal of Emerging Electric Power Systems 17(1), 27\u201338 (2016).","journal-title":"International Journal of Emerging Electric Power Systems"},{"key":"54365_CR7","doi-asserted-by":"crossref","unstructured":"Thakallapelli, A., Mehra, R. & Mangalvedekar, H.\u00a0A. Differentiation of faults from power swings and detection of high impedance faults by distance relays, in IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON), pp. 374\u2013377 (2013).","DOI":"10.1109\/CATCON.2013.6737530"},{"issue":"1","key":"54365_CR8","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1007\/s42835-024-02019-y","volume":"20","author":"S Arasu","year":"2025","unstructured":"Arasu, S. & Ananthanarayanan, R. Preventing maloperation of Mho distance relays during load encroachment conditions through a pilot scheme. Journal of Electrical Engineering & Technology 20(1), 157\u2013167 (2025).","journal-title":"Journal of Electrical Engineering & Technology"},{"key":"54365_CR9","doi-asserted-by":"crossref","unstructured":"Rajalwal, N.\u00a0K. & Ghosh, D. Superseding mal-operation of distance relay under stressed system conditions, in Wide Area Power Systems Stability, Protection, and Security. Springer, pp. 393\u2013421 (2020).","DOI":"10.1007\/978-3-030-54275-7_15"},{"key":"54365_CR10","doi-asserted-by":"crossref","unstructured":"Mortazavi, H., Mehrjerdi, H. & Saad, M. A modified load encroachment technique for power factor monitoring, in. IEEE Power & Energy Society General Meeting (PESGM), pp. 1\u20135 (2018).","DOI":"10.1109\/PESGM.2018.8586366"},{"issue":"8","key":"54365_CR11","doi-asserted-by":"publisher","first-page":"1878","DOI":"10.1049\/iet-gtd.2016.0486","volume":"11","author":"T Ghanizadeh Bolandi","year":"2017","unstructured":"Ghanizadeh Bolandi, T., Haghifam, M. R. & Khederzadeh, M. Real-time monitoring of zone 3 vulnerable distance relays to prevent maloperation under load encroachment condition. IET Generation, Transmission & Distribution 11(8), 1878\u20131888 (2017).","journal-title":"IET Generation, Transmission & Distribution"},{"key":"54365_CR12","doi-asserted-by":"crossref","unstructured":"Farid Bin Abidin, A. & Mohamed, A. On the use of voltage stability index to prevent undesirable distance relay operation during voltage instability, in 9th International Conference on Environment and Electrical Engineering, pp. 384\u2013387 (2010).","DOI":"10.1109\/EEEIC.2010.5489947"},{"issue":"4","key":"54365_CR13","doi-asserted-by":"publisher","first-page":"1639","DOI":"10.1109\/TPWRD.2013.2285502","volume":"29","author":"M Sharifzadeh","year":"2014","unstructured":"Sharifzadeh, M., Lesani, H. & Sanaye-Pasand, M. A new algorithm to stabilize distance relay operation during voltage-degraded conditions. IEEE Transactions on Power Delivery 29(4), 1639\u20131647 (2014).","journal-title":"IEEE Transactions on Power Delivery"},{"key":"54365_CR14","doi-asserted-by":"crossref","unstructured":"Jonsson, M. & Daalder, J. Distance protection and voltage stability, in International Conference on Power System Technology, vol.\u00a02, pp. 971\u2013976 (2000).","DOI":"10.1109\/ICPST.2000.897152"},{"key":"54365_CR15","doi-asserted-by":"crossref","unstructured":"Cimadevilla, R. & Garc\u00eda, I. Improvements in the operation of a distance relay during resistive faults, in 67th Annual Conference for Protective Relay Engineers, pp. 132\u2013185 (2014).","DOI":"10.1109\/CPRE.2014.6799000"},{"issue":"3","key":"54365_CR16","doi-asserted-by":"publisher","first-page":"1319","DOI":"10.1109\/TPWRD.2007.909210","volume":"23","author":"AD Filomena","year":"2008","unstructured":"Filomena, A. D., Salim, R. H., Resener, M. & Bretas, A. S. Ground distance relaying with fault-resistance compensation for unbalanced systems. IEEE Transactions on Power Delivery 23(3), 1319\u20131326 (2008).","journal-title":"IEEE Transactions on Power Delivery"},{"issue":"3","key":"54365_CR17","doi-asserted-by":"publisher","first-page":"1292","DOI":"10.1109\/61.517483","volume":"11","author":"S Zhu","year":"1996","unstructured":"Zhu, S., Xing, Y. & Sui, F. Fault component reactance relay. IEEE Transactions on Power Delivery 11(3), 1292\u20131300 (1996).","journal-title":"IEEE Transactions on Power Delivery"},{"issue":"5","key":"54365_CR18","doi-asserted-by":"publisher","first-page":"1967","DOI":"10.1109\/TPWRD.2019.2906939","volume":"34","author":"SV Unde","year":"2019","unstructured":"Unde, S. V., Gawande, P. & Dambhare, S. New algorithm for protection of double circuit transmission lines using modal currents. IEEE Transactions on Power Delivery 34(5), 1967\u20131977 (2019).","journal-title":"IEEE Transactions on Power Delivery"},{"issue":"5","key":"54365_CR19","doi-asserted-by":"publisher","first-page":"2161","DOI":"10.1109\/TPWRD.2017.2765762","volume":"33","author":"S Li","year":"2018","unstructured":"Li, S., Chen, W., Yin, X., Chen, D. & Malik, O. P. Integrated transverse differential protection scheme for double-circuit lines on the same tower. IEEE Transactions on Power Delivery 33(5), 2161\u20132169 (2018).","journal-title":"IEEE Transactions on Power Delivery"},{"issue":"1","key":"54365_CR20","doi-asserted-by":"publisher","first-page":"199","DOI":"10.35833\/MPCE.2024.000536","volume":"14","author":"B Li","year":"2026","unstructured":"Li, B. et al. Robust algorithm of time-domain distance protection for renewable power transmission system with mixed overhead lines and underground cables. Journal OF Modern Power Systems and Clean Energy 14(1), 199\u2013211 (2026).","journal-title":"Journal OF Modern Power Systems and Clean Energy"},{"key":"54365_CR21","doi-asserted-by":"publisher","first-page":"132 038","DOI":"10.1109\/ACCESS.2025.3590962","volume":"13","author":"N George","year":"2025","unstructured":"George, N., Naidu, O. & Pradhan, A. K. Source-agnostic single-ended protection and fault location for double-circuit lines connected to power electronics-based sources. IEEE Access 13, 132 038-132 051 (2025).","journal-title":"IEEE Access"},{"issue":"44","key":"54365_CR22","first-page":"1","volume":"8","author":"M Tang","year":"2023","unstructured":"Tang, M., Lu, H. & Li, B. Fault location of untransposed double-circuit transmission lines based on an improved Karrenbauer matrix and the QPSO algorithm. Protection and Control of Modern Power Systems 8(44), 1\u201314 (2023).","journal-title":"Protection and Control of Modern Power Systems"},{"key":"54365_CR23","volume-title":"Power system analysis","author":"JJ Grainger","year":"1994","unstructured":"Grainger, J. J. & Stevenson, W. D. Power system analysis (McGraw-Hill, 1994)."},{"key":"54365_CR24","doi-asserted-by":"publisher","DOI":"10.1002\/9781118172094","volume-title":"Disturbance analysis for power systems","author":"MA Ibrahim","year":"2011","unstructured":"Ibrahim, M. A. Disturbance analysis for power systems (John Wiley & Sons, 2011)."},{"key":"54365_CR25","unstructured":"IEEE guide for bonding shields and sheaths of single-conductor power cables rated 5 kV through 500 kV, IEEE Std 575-2014 (Revision of IEEE Std 575-1988), pp. 1\u201383 (2014)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54365-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54365-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54365-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T23:21:08Z","timestamp":1786058468000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-54365-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,28]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["54365"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-54365-8","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,28]]},"assertion":[{"value":"10 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"24399"}}