{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T23:20:01Z","timestamp":1787527201233,"version":"build-2736575974"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T00:00:00Z","timestamp":1780963200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T00:00:00Z","timestamp":1787529600000},"content-version":"vor","delay-in-days":76,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-56918-3","type":"journal-article","created":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T15:25:11Z","timestamp":1781018711000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Retinal arteriovenous oxygen saturation difference is inversely associated with cardiac output measured by echocardiography: a non-invasive pilot study"],"prefix":"10.1038","volume":"16","author":[{"given":"Tom\u00e1\u0161","family":"K\u0159ivohlav\u00fd","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Lada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Mal\u00fd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Jakl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kry\u0161tof","family":"Kr\u00e1sa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"\u0160\u00edn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,9]]},"reference":[{"key":"56918_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/aos.12086","volume":"91","author":"SH Hardarson","year":"2013","unstructured":"Hardarson, S. H. Retinal oximetry. Acta Ophthalmol. 91, 1\u201347 (2013).","journal-title":"Acta Ophthalmol."},{"key":"56918_CR2","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1111\/aos.14397","volume":"98","author":"A Shughoury","year":"2020","unstructured":"Shughoury, A. et al. Retinal oximetry in glaucoma: investigations and findings reviewed. Acta Ophthalmol. 98, 559\u2013571 (2020).","journal-title":"Acta Ophthalmol."},{"key":"56918_CR3","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1111\/aos.13229","volume":"95","author":"S Rilv\u00e9n","year":"2017","unstructured":"Rilv\u00e9n, S., Torp, T. L. & Grauslund, J. Retinal oximetry in patients with ischaemic retinal diseases. Acta Ophthalmol. 95, 119\u2013127 (2017).","journal-title":"Acta Ophthalmol."},{"key":"56918_CR4","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1111\/aos.15066","volume":"100","author":"AV Belamkar","year":"2022","unstructured":"Belamkar, A. V., Jabbehdari, S., Harris, A. & Hajrasouliha, A. R. Clinical implications of retinal oximetry in retinal vein occlusion: a review. Acta Ophthalmol. 100, 624\u2013631 (2022).","journal-title":"Acta Ophthalmol."},{"key":"56918_CR5","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1111\/aos.14466","volume":"99","author":"M Della Volpe Waizel","year":"2021","unstructured":"Della Volpe Waizel, M., Scholl, H. P. N., Valmaggia, C. & Todorova, M. G. Retinal vessel oximetry in children with inherited retinal diseases. Acta Ophthalmol. 99, 52\u201360 (2021).","journal-title":"Acta Ophthalmol."},{"issue":"Suppl","key":"56918_CR6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/aos.13932","volume":"96","author":"TS Eliasdottir","year":"2018","unstructured":"Eliasdottir, T. S. Retinal oximetry and systemic arterial oxygen levels. Acta Ophthalmol. 96 (Suppl), 1\u201344 (2018).","journal-title":"Acta Ophthalmol."},{"key":"56918_CR7","doi-asserted-by":"publisher","first-page":"79","DOI":"10.3233\/JAD-150457","volume":"49","author":"AB Einarsdottir","year":"2016","unstructured":"Einarsdottir, A. B. et al. Retinal oximetry imaging in Alzheimer\u2019s disease. J. Alzheimers Dis. 49, 79\u201383 (2016).","journal-title":"J. Alzheimers Dis."},{"key":"56918_CR8","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1111\/aos.13682","volume":"96","author":"AB Einarsdottir","year":"2018","unstructured":"Einarsdottir, A. B., Olafsdottir, O. B., Hjaltason, H. & Hardarson, S. H. Retinal oximetry is affected in multiple sclerosis. Acta Ophthalmol. 96, 528\u2013530 (2018).","journal-title":"Acta Ophthalmol."},{"key":"56918_CR9","doi-asserted-by":"publisher","first-page":"e0174026","DOI":"10.1371\/journal.pone.0174026","volume":"12","author":"TS Eliasdottir","year":"2017","unstructured":"Eliasdottir, T. S. et al. Retinal oximetry measures systemic hypoxia in central nervous system vessels in chronic obstructive pulmonary disease. PLoS One. 12, e0174026 (2017).","journal-title":"PLoS One"},{"key":"56918_CR10","unstructured":"Fick, A. \u00dcber die Messung des Blutquantums in den Herzventrikeln. Verh Phys. Med. Ges W\u00fcrzburg 2, 16 (1870)."},{"key":"56918_CR11","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1161\/01.CIR.67.3.593","volume":"67","author":"LL Huntsman","year":"1983","unstructured":"Huntsman, L. L. et al. Noninvasive Doppler determination of cardiac output in man. Circulation 67, 593\u2013602 (1983).","journal-title":"Circulation"},{"key":"56918_CR12","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1007\/BF01728328","volume":"22","author":"A Descorps-Declere","year":"1996","unstructured":"Descorps-Declere, A. et al. Transgastric, pulsed Doppler echocardiographic determination of cardiac output. Intensive Care Med. 22, 34\u201338 (1996).","journal-title":"Intensive Care Med."},{"key":"56918_CR13","doi-asserted-by":"publisher","first-page":"e0222105","DOI":"10.1371\/journal.pone.0222105","volume":"14","author":"Y Zhang","year":"2019","unstructured":"Zhang, Y., Wang, Y., Shi, J., Hua, Z. & Xu, J. Cardiac output measurements via echocardiography versus thermodilution: a systematic review and meta-analysis. PLoS One. 14, e0222105 (2019).","journal-title":"PLoS One"},{"key":"56918_CR14","doi-asserted-by":"crossref","first-page":"e308","DOI":"10.1111\/aos.13890","volume":"97","author":"K Van Keer","year":"2019","unstructured":"Van Keer, K. et al. Retinal oxygen saturation as a non-invasive estimate for mixed venous oxygen saturation and cardiac output. Acta Ophthalmol. 97, e308\u2013e312 (2019).","journal-title":"Acta Ophthalmol."},{"key":"56918_CR15","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1111\/aos.14444","volume":"98","author":"S Dinesen","year":"2020","unstructured":"Dinesen, S. et al. Coronary artery bypass surgery independently associates with retinal vascular oxygen saturation. Acta Ophthalmol. 98, 709\u2013715 (2020).","journal-title":"Acta Ophthalmol."},{"key":"56918_CR16","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1136\/bjophthalmol-2011-300640","volume":"96","author":"SH Hardarson","year":"2012","unstructured":"Hardarson, S. H. & Stef\u00e1nsson, E. Retinal oxygen saturation is altered in diabetic retinopathy. Br. J. Ophthalmol. 96, 560\u2013563 (2012).","journal-title":"Br. J. Ophthalmol."},{"key":"56918_CR17","first-page":"1695","volume":"103","author":"AM Abu El-Asrar","year":"2019","unstructured":"Abu El-Asrar, A. M., AlBloushi, A. F., Gikandi, P. W., Hardarson, S. H. & Stef\u00e1nsson, E. Retinal vessel oxygen saturation is affected in uveitis associated with Vogt\u2013Koyanagi\u2013Harada disease. Br. J. Ophthalmol. 103, 1695\u20131699 (2019).","journal-title":"Br. J. Ophthalmol."},{"key":"56918_CR18","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1111\/aos.12011","volume":"92","author":"E Vandewalle","year":"2014","unstructured":"Vandewalle, E. et al. Oximetry in glaucoma: correlation of metabolic change with structural and functional damage. Acta Ophthalmol. 92, 105\u2013110 (2014).","journal-title":"Acta Ophthalmol."},{"key":"56918_CR19","first-page":"99","volume":"9","author":"LL Lin","year":"2016","unstructured":"Lin, L. L. et al. Study of retinal vessel oxygen saturation in ischemic and non-ischemic branch retinal vein occlusion. Int. J. Ophthalmol. 9, 99\u2013107 (2016).","journal-title":"Int. J. Ophthalmol."},{"key":"56918_CR20","doi-asserted-by":"publisher","first-page":"e13","DOI":"10.1111\/aos.14503","volume":"99","author":"W Zhang","year":"2021","unstructured":"Zhang, W. et al. Retinal vessel oxygen saturation in patients with unilateral internal carotid artery stenosis: a pilot study. Acta Ophthalmol. 99, e13\u2013e18 (2021).","journal-title":"Acta Ophthalmol."},{"key":"56918_CR21","doi-asserted-by":"publisher","first-page":"1729","DOI":"10.1167\/iovs.11-8621","volume":"53","author":"O Palsson","year":"2012","unstructured":"Palsson, O. et al. Retinal oximetry images must be standardized: a methodological analysis. Invest. Ophthalmol. Vis. Sci. 53, 1729\u20131733 (2012).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"56918_CR22","doi-asserted-by":"publisher","first-page":"5433","DOI":"10.1167\/iovs.12-9912","volume":"53","author":"A Geirsdottir","year":"2012","unstructured":"Geirsdottir, A. et al. Retinal vessel oxygen saturation in healthy individuals. Invest. Ophthalmol. Vis. Sci. 53, 5433\u20135442 (2012).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"56918_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.echo.2014.10.003","volume":"28","author":"RM Lang","year":"2015","unstructured":"Lang, R. M. et al. Recommendations for cardiac chamber quantification by echocardiography in adults. J. Am. Soc. Echocardiogr. 28, 1\u201339 (2015).","journal-title":"J. Am. Soc. Echocardiogr"},{"key":"56918_CR24","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1067\/mje.2002.120202","volume":"15","author":"MA Qui\u00f1ones","year":"2002","unstructured":"Qui\u00f1ones, M. A., Otto, C. M., Stoddard, M., Waggoner, A. & Zoghbi, W. A. Recommendations for quantification of Doppler echocardiography. J. Am. Soc. Echocardiogr. 15, 167\u2013184 (2002).","journal-title":"J. Am. Soc. Echocardiogr"},{"key":"56918_CR25","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1016\/j.hlc.2021.06.525","volume":"31","author":"K Ellenberger","year":"2022","unstructured":"Ellenberger, K. et al. The effect of obesity on echocardiographic image quality. Heart Lung Circ. 31, 207\u2013215 (2022).","journal-title":"Heart Lung Circ."},{"key":"56918_CR26","first-page":"280","volume":"52","author":"CH Cook","year":"2002","unstructured":"Cook, C. H., Praba, A. C., Beery, P. R. & Martin, L. C. Transthoracic echocardiography is not cost-effective in critically ill surgical patients. J. Trauma. 52, 280\u2013284 (2002).","journal-title":"J. Trauma."},{"key":"56918_CR27","doi-asserted-by":"publisher","first-page":"11387","DOI":"10.1038\/s41598-019-47621-7","volume":"9","author":"DT DePaoli","year":"2019","unstructured":"DePaoli, D. T. et al. Convolutional neural networks for spectroscopic analysis in retinal oximetry. Sci. Rep. 9, 11387 (2019).","journal-title":"Sci. Rep."},{"key":"56918_CR28","doi-asserted-by":"publisher","first-page":"e0260120","DOI":"10.1371\/journal.pone.0260120","volume":"16","author":"RA Karlsson","year":"2021","unstructured":"Karlsson, R. A. et al. Automation improves repeatability of retinal oximetry measurements. PLoS One. 16, e0260120 (2021).","journal-title":"PLoS One"},{"key":"56918_CR29","doi-asserted-by":"publisher","first-page":"722","DOI":"10.3390\/photonics10070722","volume":"10","author":"Y Xian","year":"2023","unstructured":"Xian, Y., Zhao, G., Wang, C., Chen, X. & Dai, Y. A novel hybrid retinal blood vessel segmentation algorithm for enlarging the measuring range of dual-wavelength retinal oximetry. Photonics 10, 722 (2023).","journal-title":"Photonics"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-56918-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-56918-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-56918-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T22:59:02Z","timestamp":1787525942000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-56918-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,9]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["56918"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-56918-3","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,9]]},"assertion":[{"value":"18 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"26403"}}