{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T00:18:04Z","timestamp":1787876284445,"version":"build-2784847793"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T00:00:00Z","timestamp":1781308800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T00:00:00Z","timestamp":1787875200000},"content-version":"vor","delay-in-days":76,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-57527-w","type":"journal-article","created":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T15:44:20Z","timestamp":1781365460000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Staged screw removal in external plate fixation for distal tibial fractures: a finite element study on adaptive biomechanics"],"prefix":"10.1038","volume":"16","author":[{"given":"Mingming","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huadong","family":"Yan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianhua","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuanzheng","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hua","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,13]]},"reference":[{"key":"57527_CR1","doi-asserted-by":"publisher","unstructured":"Sathone, I. R. & Potdar, U. G. Finite element analysis and optimization studies on tibia implant of SS 316L steel and Ti6Al4V alloy. Biomed. Phys. Eng. Express. 10 https:\/\/doi.org\/10.1088\/2057-1976\/ad8095 (2024).","DOI":"10.1088\/2057-1976\/ad8095"},{"key":"57527_CR2","doi-asserted-by":"publisher","first-page":"57","DOI":"10.5704\/MOJ.2011.010","volume":"14","author":"I Rushdi","year":"2020","unstructured":"Rushdi, I., Che-Ahmad, A., Abdul-Ghani, K. & Mohd-Rus, R. Surgical Management of Distal Tibia Fracture: Towards An Outcome-based Treatment Algorithm. Malays Orthop. J. 14, 57\u201365. https:\/\/doi.org\/10.5704\/MOJ.2011.010 (2020).","journal-title":"Malays Orthop. J."},{"key":"57527_CR3","doi-asserted-by":"publisher","first-page":"215","DOI":"10.13107\/jocr.2025.v15.i02.5288","volume":"15","author":"TP Gupta","year":"2025","unstructured":"Gupta, T. P., Singh, N., Rai, S. K., Philip, V. M. & Sharma, R. Internal Plate Fixation of Comminuted Fracture of the Distal End of the Tibia and Fibula Using a Single-Incision Technique: A Novel Approach and a Series of Nine Cases. J. Orthop. Case Rep. 15, 215\u2013220. https:\/\/doi.org\/10.13107\/jocr.2025.v15.i02.5288 (2025).","journal-title":"J. Orthop. Case Rep."},{"key":"57527_CR4","doi-asserted-by":"publisher","first-page":"275","DOI":"10.13107\/jocr.2025.v15.i07.5848","volume":"15","author":"A Saxena","year":"2025","unstructured":"Saxena, A., Mahore, S. K., Gupta, A., Sriwastava, A. K. & Gupta, M. Comparative Evaluation of Functional Outcomes Following Surgical and Conservative Management of Distal Tibia Shaft Fractures: A Prospective Observational Study. J. Orthop. Case Rep. 15, 275\u2013281. https:\/\/doi.org\/10.13107\/jocr.2025.v15.i07.5848 (2025).","journal-title":"J. Orthop. Case Rep."},{"key":"57527_CR5","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1186\/s13018-024-04900-y","volume":"19","author":"X Li","year":"2024","unstructured":"Li, X., Chen, K., Xue, H., Cheng, J. & Yu, X. Efficacy comparison between intramedullary nail fixation and plate fixation in distal tibia fractures: a meta-analysis of randomized controlled trials. J. Orthop. Surg. Res. 19, 403. https:\/\/doi.org\/10.1186\/s13018-024-04900-y (2024).","journal-title":"J. Orthop. Surg. Res."},{"key":"57527_CR6","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1007\/s00402-013-1916-1","volume":"134","author":"XS Qiu","year":"2014","unstructured":"Qiu, X. S. et al. Locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop. Arch. Orthop. Trauma. Surg. 134, 383\u2013388. https:\/\/doi.org\/10.1007\/s00402-013-1916-1 (2014).","journal-title":"Arch. Orthop. Trauma. Surg."},{"key":"57527_CR7","doi-asserted-by":"publisher","first-page":"106882","DOI":"10.1016\/j.ijscr.2022.106882","volume":"93","author":"L Hidayat","year":"2022","unstructured":"Hidayat, L. et al. Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series. Int. J. Surg. Case Rep. 93, 106882. https:\/\/doi.org\/10.1016\/j.ijscr.2022.106882 (2022).","journal-title":"Int. J. Surg. Case Rep."},{"key":"57527_CR8","doi-asserted-by":"publisher","first-page":"962","DOI":"10.1186\/s12891-023-07097-z","volume":"24","author":"ML Bangura","year":"2023","unstructured":"Bangura, M. L. et al. Comparative analysis of external locking plate and combined frame external fixator for open distal tibial fractures: a comprehensive assessment of clinical outcomes and financial implications. BMC Musculoskelet. Disord. 24, 962. https:\/\/doi.org\/10.1186\/s12891-023-07097-z (2023).","journal-title":"BMC Musculoskelet. Disord"},{"key":"57527_CR9","doi-asserted-by":"publisher","first-page":"280","DOI":"10.13107\/jocr.2025.v15.i08.5970","volume":"15","author":"S Roy","year":"2025","unstructured":"Roy, S. et al. Externally Applied Metaphyseal Locking Plate: An Alternative to Unilateral External Fixator in Definitive Management of Compound Tibia Fractures - A Prospective Study. J. Orthop. Case Rep. 15, 280\u2013286. https:\/\/doi.org\/10.13107\/jocr.2025.v15.i08.5970 (2025).","journal-title":"J. Orthop. Case Rep."},{"key":"57527_CR10","doi-asserted-by":"publisher","first-page":"558","DOI":"10.1186\/s13018-020-02096-5","volume":"15","author":"K Zhou","year":"2020","unstructured":"Zhou, K., He, X., Tao, X., Pan, F. & Yang, H. A biomechanical matched-pair comparison of two different locking plates for tibial diaphyseal comminuted fracture: carbon fiber-reinforced poly-ether-ether-ketone (CF-PEEK) versus titanium plates. J. Orthop. Surg. Res. 15, 558. https:\/\/doi.org\/10.1186\/s13018-020-02096-5 (2020).","journal-title":"J. Orthop. Surg. Res."},{"key":"57527_CR11","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1186\/s13018-025-05681-8","volume":"20","author":"S Liu","year":"2025","unstructured":"Liu, S. et al. A novel external fixation for treating tibial fractures: a finite element and biomechanical study. J. Orthop. Surg. Res. 20, 319. https:\/\/doi.org\/10.1186\/s13018-025-05681-8 (2025).","journal-title":"J. Orthop. Surg. Res."},{"key":"57527_CR12","doi-asserted-by":"publisher","first-page":"2905","DOI":"10.3390\/jcm13102905","volume":"13","author":"M Bottlang","year":"2024","unstructured":"Bottlang, M. et al. Advances in Dynamization of Plate Fixation to Promote Natural Bone Healing. J. Clin. Med. 13, 2905. https:\/\/doi.org\/10.3390\/jcm13102905 (2024).","journal-title":"J. Clin. Med."},{"key":"57527_CR13","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1186\/s12891-023-06150-1","volume":"24","author":"H Su","year":"2023","unstructured":"Su, H. et al. Biomechanical study of the stiffness of the femoral locking compression plate of an external fixator for lower tibial fractures. BMC Musculoskelet. Disord. 24, 39. https:\/\/doi.org\/10.1186\/s12891-023-06150-1 (2023).","journal-title":"BMC Musculoskelet. Disord"},{"key":"57527_CR14","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1186\/s13018-021-02907-3","volume":"17","author":"D Bla\u017eevi\u0107","year":"2022","unstructured":"Bla\u017eevi\u0107, D. et al. Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis. J. Orthop. Surg. Res. 17, 16. https:\/\/doi.org\/10.1186\/s13018-021-02907-3 (2022).","journal-title":"J. Orthop. Surg. Res."},{"key":"57527_CR15","doi-asserted-by":"publisher","first-page":"2821","DOI":"10.1111\/os.14195","volume":"16","author":"X Jia","year":"2024","unstructured":"Jia, X. et al. How Does the Stress in the Fixation Device Change during Different Stages of Bone Healing in the Treatment of Fractures? A Finite Element Study of External Fixation for Tibial Fractures. Orthop. Surg. 16, 2821\u20132833. https:\/\/doi.org\/10.1111\/os.14195 (2024).","journal-title":"Orthop. Surg."},{"key":"57527_CR16","doi-asserted-by":"publisher","first-page":"3814","DOI":"10.12307\/2024.607","volume":"28","author":"HD Yan","year":"2024","unstructured":"Yan, H. D. et al. Biomechanical difference of different fixation methods in bone healing of distal tibial comminuted fractures analyzed by finite element method. Chin. J. Tissue Eng. Res. 28, 3814\u20133821. https:\/\/doi.org\/10.12307\/2024.607 (2024).","journal-title":"Chin. J. Tissue Eng. Res."},{"key":"57527_CR17","doi-asserted-by":"publisher","first-page":"1067845","DOI":"10.3389\/fbioe.2023.1067845","volume":"11","author":"M Orth","year":"2023","unstructured":"Orth, M. et al. Simulation-based prediction of bone healing and treatment recommendations for lower leg fractures: Effects of motion, weight-bearing and fibular mechanics. Front. Bioeng. Biotechnol. 11, 1067845. https:\/\/doi.org\/10.3389\/fbioe.2023.1067845 (2023).","journal-title":"Front. Bioeng. Biotechnol."},{"key":"57527_CR18","doi-asserted-by":"publisher","first-page":"6744","DOI":"10.1038\/s41598-018-25229-7","volume":"8","author":"M Wang","year":"2018","unstructured":"Wang, M. & Yang, N. Three-dimensional computational model simulating the fracture healing process with both biphasic poroelastic finite element analysis and fuzzy logic control. Sci. Rep. 8, 6744. https:\/\/doi.org\/10.1038\/s41598-018-25229-7 (2018).","journal-title":"Sci. Rep."},{"key":"57527_CR19","doi-asserted-by":"publisher","first-page":"879","DOI":"10.12307\/2023.797","volume":"28","author":"MM Wang","year":"2024","unstructured":"Wang, M. M. et al. Finite element analysis of three different minimally invasive fixation methods for distal tibial fractures with soft tissue injury. Chin. J. Tissue Eng. Res. 28, 879\u2013885. https:\/\/doi.org\/10.12307\/2023.797 (2024).","journal-title":"Chin. J. Tissue Eng. Res."},{"key":"57527_CR20","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1186\/1471-2474-14-110","volume":"14","author":"CA Luo","year":"2013","unstructured":"Luo, C. A., Hua, S. Y., Lin, S. C., Chen, C. M. & Tseng, C. S. Stress and stability comparison between different systems for high tibial osteotomies. BMC Musculoskelet. Disord. 14, 110. https:\/\/doi.org\/10.1186\/1471-2474-14-110 (2013).","journal-title":"BMC Musculoskelet. Disord"},{"key":"57527_CR21","doi-asserted-by":"publisher","first-page":"1496","DOI":"10.1002\/jor.21362","volume":"29","author":"DP Byrne","year":"2011","unstructured":"Byrne, D. P., Lacroix, D. & Prendergast, P. J. Simulation of fracture healing in the tibia: mechanoregulation of cell activity using a lattice modeling approach. J. Orthop. Res. 29, 1496\u20131503. https:\/\/doi.org\/10.1002\/jor.21362 (2011).","journal-title":"J. Orthop. Res."},{"issue":"3","key":"57527_CR22","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/S0021-9290(98)00153-5","volume":"32","author":"LE Claes","year":"1999","unstructured":"Claes, L. E. & Heigele, C. A. Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing. J. Biomech. 32(3), 255\u2013266. https:\/\/doi.org\/10.1016\/S0021-9290(98)00153-5 (1999).","journal-title":"J. Biomech."},{"issue":"12","key":"57527_CR23","doi-asserted-by":"publisher","first-page":"e115695","DOI":"10.1371\/journal.pone.0115695","volume":"9","author":"T Wehner","year":"2014","unstructured":"Wehner, T., Steiner, M., Ignatius, A. & Claes, L. Prediction of the time course of callus stiffness as a function of mechanical parameters in experimental rat fracture healing studies\u2014a numerical study. PLoS ONE. 9(12), e115695. https:\/\/doi.org\/10.1371\/journal.pone.0115695 (2014).","journal-title":"PLoS ONE"},{"issue":"2","key":"57527_CR24","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/j.bone.2009.04.249","volume":"45","author":"I Manjubala","year":"2009","unstructured":"Manjubala, I. et al. Spatial and temporal variations of mechanical properties and mineral content of the external callus during bone healing. Bone 45(2), 185\u2013192. https:\/\/doi.org\/10.1016\/j.bone.2009.04.249 (2009).","journal-title":"Bone"},{"key":"57527_CR25","doi-asserted-by":"publisher","first-page":"1476473","DOI":"10.3389\/fbioe.2024.1476473","volume":"12","author":"P Bl\u00e1zquez-Carmona","year":"2024","unstructured":"Bl\u00e1zquez-Carmona, P., Mora-Mac\u00edas, J., Morgaz, J., Dom\u00ednguez, J. & Reina-Romo, E. On the influence of structural and chemical properties on the elastic modulus of woven bone under healing. Front. Bioeng. Biotechnol. 12, 1476473. https:\/\/doi.org\/10.3389\/fbioe.2024.1476473 (2024).","journal-title":"Front. Bioeng. Biotechnol."},{"key":"57527_CR26","doi-asserted-by":"publisher","first-page":"14","DOI":"10.9718\/JBER.2013.34.1.14","volume":"34","author":"HS Kim","year":"2013","unstructured":"Kim, H. S. Evaluation of biomechanical stability of newly developed revision total knee arthroplasty through strain and stress distribution analysis within the tibia: Finite element analysis. J. Biomed. Eng. Res. 34, 14\u201323. https:\/\/doi.org\/10.9718\/JBER.2013.34.1.14 (2013).","journal-title":"J. Biomed. Eng. Res."},{"key":"57527_CR27","doi-asserted-by":"publisher","first-page":"14538","DOI":"10.1038\/s41598-024-64990-w","volume":"14","author":"BH Lee","year":"2024","unstructured":"Lee, B. H. et al. Comparison of tibial fracture plate length, placement, and fibular integrity effects on plate integrity through finite element analysis. Sci. Rep. 14, 14538. https:\/\/doi.org\/10.1038\/s41598-024-64990-w (2024).","journal-title":"Sci. Rep."},{"key":"57527_CR28","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1080\/10255842.2021.1888939","volume":"24","author":"JCM Souza","year":"2021","unstructured":"Souza, J. C. M., Pinho, S. S., Braz, M. P., Silva, F. S. & Henriques, B. Carbon fiber-reinforced PEEK in implant dentistry: A scoping review on the finite element method. Comput. Methods Biomech. Biomed. Engin. 24, 1355\u20131367. https:\/\/doi.org\/10.1080\/10255842.2021.1888939 (2021).","journal-title":"Comput. Methods Biomech. Biomed. Engin"},{"key":"57527_CR29","doi-asserted-by":"publisher","first-page":"1781","DOI":"10.1038\/s41598-021-81401-6","volume":"11","author":"Y Wang","year":"2021","unstructured":"Wang, Y. et al. A finite element analysis of relationship between fracture, implant and tibial tunnel. Sci. Rep. 11, 1781. https:\/\/doi.org\/10.1038\/s41598-021-81401-6 (2021).","journal-title":"Sci. Rep."},{"key":"57527_CR30","doi-asserted-by":"publisher","first-page":"4769","DOI":"10.3390\/jcm14134769","volume":"14","author":"GH Jung","year":"2025","unstructured":"Jung, G. H., Jeong, S. L. & Ahn, J. Stress Distribution in Interlocking and Blocking Screw Fixation for Distal Tibial Intramedullary Nailing: A Finite Element Analysis. J. Clin. Med. 14, 4769. https:\/\/doi.org\/10.3390\/jcm14134769 (2025).","journal-title":"J. Clin. Med."},{"key":"57527_CR31","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1080\/08941939.2020.1836290","volume":"35","author":"K Zhou","year":"2022","unstructured":"Zhou, K. & Yang, H. Effects of Bone-Plate Material on the Predicted Stresses in the Tibial Shaft Comminuted Fractures: A Finite Element Analysis. J. Invest. Surg. 35, 132\u2013140. https:\/\/doi.org\/10.1080\/08941939.2020.1836290 (2022).","journal-title":"J. Invest. Surg."},{"key":"57527_CR32","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.1007\/s11596-025-00116-1","volume":"45","author":"H Su","year":"2025","unstructured":"Su, H. et al. Effect of Screw Distribution on Stability and Interfragmentary Strain of Lower Tibial Fractures: A Finite Element Analysis. Curr. Med. Sci. 45, 1254\u20131264. https:\/\/doi.org\/10.1007\/s11596-025-00116-1 (2025).","journal-title":"Curr. Med. Sci."},{"key":"57527_CR33","doi-asserted-by":"publisher","first-page":"1600","DOI":"10.3390\/jcm12041600","volume":"12","author":"B Makelov","year":"2023","unstructured":"Makelov, B. et al. Single-Stage Externalized Locked Plating for Treatment of Unstable Meta-Diaphyseal Tibial Fractures. J. Clin. Med. 12, 1600. https:\/\/doi.org\/10.3390\/jcm12041600 (2023).","journal-title":"J. Clin. Med."},{"key":"57527_CR34","doi-asserted-by":"publisher","first-page":"e9083","DOI":"10.1097\/MD.0000000000009083","volume":"96","author":"P Luo","year":"2017","unstructured":"Luo, P., Xu, D., Wu, J. & Chen, Y. H. Locked plating as an external fixator in treating tibial fractures: A PRISMA-compliant systematic review. Med. (Baltim). 96, e9083. https:\/\/doi.org\/10.1097\/MD.0000000000009083 (2017).","journal-title":"Med. (Baltim)."},{"key":"57527_CR35","doi-asserted-by":"publisher","first-page":"382","DOI":"10.13107\/jocr.2025.v15.i09.6132","volume":"15","author":"I Pandor","year":"2025","unstructured":"Pandor, I. et al. Low Profile, High Impact: External Fixation using Locking Plates in Challenging Tibial Fractures. J. Orthop. Case Rep. 15, 382\u2013386. https:\/\/doi.org\/10.13107\/jocr.2025.v15.i09.6132 (2025).","journal-title":"J. Orthop. Case Rep."},{"key":"57527_CR36","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1302\/0301-620x.84b8.13752","volume":"84","author":"SM Perren","year":"2002","unstructured":"Perren, S. M. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J. Bone Joint Surg. Br. 84, 1093\u20131110. https:\/\/doi.org\/10.1302\/0301-620x.84b8.13752 (2002).","journal-title":"J. Bone Joint Surg. Br."},{"key":"57527_CR37","doi-asserted-by":"publisher","first-page":"959306","DOI":"10.3389\/fsurg.2022.959306","volume":"9","author":"B Liu","year":"2022","unstructured":"Liu, B. et al. Influence of different fixation modes on biomechanical conduction of 3D printed prostheses for treating critical diaphyseal defects of lower limbs: A finite element study. Front. Surg. 9, 959306. https:\/\/doi.org\/10.3389\/fsurg.2022.959306 (2022).","journal-title":"Front. Surg."},{"key":"57527_CR38","doi-asserted-by":"publisher","first-page":"2222","DOI":"10.1016\/j.corsci.2011.03.004","volume":"53","author":"N Maruyama","year":"2011","unstructured":"Maruyama, N., Mori, D., Hiromoto, S., Kanazawa, K. & Nakamura, M. Fatigue strength of 316L-type stainless steel in simulated body fluids. Corros. Sci. 53, 2222\u20132227. https:\/\/doi.org\/10.1016\/j.corsci.2011.03.004 (2011).","journal-title":"Corros. Sci."},{"key":"57527_CR39","doi-asserted-by":"publisher","first-page":"106820","DOI":"10.1016\/j.jmbbm.2024.106820","volume":"161","author":"T Koyama","year":"2025","unstructured":"Koyama, T. et al. TiNbSn alloy plates with low Young\u2019s modulus modulates interfragmentary movement and promote osteosynthesis in rat femur. J. Mech. Behav. Biomed. Mater. 161, 106820. https:\/\/doi.org\/10.1016\/j.jmbbm.2024.106820 (2025).","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"57527_CR40","doi-asserted-by":"publisher","first-page":"980","DOI":"10.3390\/ma12060980","volume":"12","author":"A Brizuela","year":"2019","unstructured":"Brizuela, A. et al. Gil Mur, Influence of the Elastic Modulus on the Osseointegration of Dental Implants. Mater. (Basel). 12, 980. https:\/\/doi.org\/10.3390\/ma12060980 (2019).","journal-title":"Mater. (Basel)"},{"key":"57527_CR41","doi-asserted-by":"publisher","first-page":"e138","DOI":"10.1097\/OI9.0000000000000138","volume":"4","author":"CC Barber","year":"2021","unstructured":"Barber, C. C., Burnham, M., Ojameruaye, O. & McKee, M. D. A systematic review of the use of titanium versus stainless steel implants for fracture fixation. OTA Int. 4, e138. https:\/\/doi.org\/10.1097\/OI9.0000000000000138 (2021).","journal-title":"OTA Int."},{"key":"57527_CR42","doi-asserted-by":"publisher","first-page":"2147","DOI":"10.1007\/s00590-024-03919-5","volume":"34","author":"M Kutzler","year":"2024","unstructured":"Kutzler, M. et al. Titanium versus stainless steel alloy bridge plates for distal femur fractures: Does callus form earlier with titanium? Eur. J. Orthop. Surg. Traumatol. 34, 2147\u20132153. https:\/\/doi.org\/10.1007\/s00590-024-03919-5 (2024).","journal-title":"Eur. J. Orthop. Surg. Traumatol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-57527-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-57527-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-57527-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T23:51:56Z","timestamp":1787874716000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-57527-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,13]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["57527"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-57527-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,13]]},"assertion":[{"value":"13 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.\u00a0","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This work was supported by the Zaozhuang Science and Technology Development Plan Project (Grant No. 2026NS58).","order":2,"name":"Ethics","label":"<b>Funding<\/b>","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All clinical data analysis procedures involving human participants were conducted in accordance with the ethical standards of the institutional research committee and with the 1964 Helsinki declaration and its later amendments. The study protocol was approved by the Ethics Committee of Tengzhou Central People\u2019s Hospital Affiliated to Jining Medical University (Approval No.: 2023-Ethical Review-33). Informed consent was obtained from all individual participants included in the clinical data analysis. For the computational biomechanics study, informed consent was obtained from the volunteer for the acquisition and use of CT data.","order":3,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"27050"}}