{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T00:07:30Z","timestamp":1788998850155,"version":"build-2803163510"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,20]],"date-time":"2026-06-20T00:00:00Z","timestamp":1781913600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T00:00:00Z","timestamp":1788998400000},"content-version":"vor","delay-in-days":82,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Japanese Orthopaedic Association (JOA) Project Research Grant","award":["2021-1"],"award-info":[{"award-number":["2021-1"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-026-58052-6","type":"journal-article","created":{"date-parts":[[2026,6,20]],"date-time":"2026-06-20T10:15:34Z","timestamp":1781950534000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Real-time phase-dependent occupational radiation exposure analysis in full-endoscopic spine surgery"],"prefix":"10.1038","volume":"16","author":[{"given":"Takayuki","family":"Kitahara","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takafumi","family":"Ohshima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daiki","family":"Nakajima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seiya","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saori","family":"Soeda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Makoto","family":"Takeuchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Kageyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junzo","family":"Fujitani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masatoshi","family":"Morimoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroaki","family":"Manabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fumitake","family":"Tezuka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koichi","family":"Sairyo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,20]]},"reference":[{"key":"58052_CR1","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.jos.2017.10.015","volume":"23","author":"K Sairyo","year":"2018","unstructured":"Sairyo, K., Chikawa, T. & Nagamachi, A. State-of-the-art transforaminal percutaneous endoscopic lumbar surgery under local anesthesia: Discectomy, foraminoplasty, and ventral facetectomy. J. Orthop. Sci. 23, 229\u2013236. https:\/\/doi.org\/10.1016\/j.jos.2017.10.015 (2018).","journal-title":"J. Orthop. Sci."},{"key":"58052_CR2","doi-asserted-by":"publisher","first-page":"169","DOI":"10.2152\/jmi.71.169","volume":"71","author":"K Kishima","year":"2024","unstructured":"Kishima, K. et al. Full-endoscopic spine surgery in oldest old patients aged over 90 years: a case report. J. Med. Invest. 71, 169\u2013173. https:\/\/doi.org\/10.2152\/jmi.71.169 (2024).","journal-title":"J. Med. Invest."},{"key":"58052_CR3","doi-asserted-by":"publisher","DOI":"10.14444\/1028","volume":"8","author":"S Gore","year":"2014","unstructured":"Gore, S. & Yeung, A. The \u201cinside out\u201d transforaminal technique to treat lumbar spinal pain in an awake and aware patient under local anesthesia: results and a review of the literature. Int. J. Spine Surg. 8, 28. https:\/\/doi.org\/10.14444\/1028 (2014).","journal-title":"Int. J. Spine Surg."},{"key":"58052_CR4","doi-asserted-by":"publisher","first-page":"264","DOI":"10.2152\/jmi.61.264","volume":"61","author":"K Sairyo","year":"2014","unstructured":"Sairyo, K. et al. Surgery related complications in percutaneous endoscopic lumbar discectomy under local anesthesia. J. Med. Invest. 61, 264\u2013269. https:\/\/doi.org\/10.2152\/jmi.61.264 (2014).","journal-title":"J. Med. Invest."},{"key":"58052_CR5","doi-asserted-by":"publisher","first-page":"529","DOI":"10.21037\/jss.2019.09.17","volume":"5","author":"K Ishii","year":"2019","unstructured":"Ishii, K., Iwai, H., Oka, H., Otomo, K. & Inanami, H. A protective method to reduce radiation exposure to the surgeon during endoscopic lumbar spine surgery. J. Spine Surg. 5, 529\u2013534. https:\/\/doi.org\/10.21037\/jss.2019.09.17 (2019).","journal-title":"J. Spine Surg."},{"key":"58052_CR6","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0095233","volume":"9","author":"H Funao","year":"2014","unstructured":"Funao, H. et al. Surgeons\u2019 exposure to radiation in single- and multi-level minimally invasive transforaminal lumbar interbody fusion; A prospective study. PLoS ONE 9, e95233. https:\/\/doi.org\/10.1371\/journal.pone.0095233 (2014).","journal-title":"PLoS ONE"},{"key":"58052_CR7","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-53472-z","volume":"9","author":"G Bratschitsch","year":"2019","unstructured":"Bratschitsch, G. et al. Radiation exposure of patient and operating room personnel by fluoroscopy and navigation during spinal surgery. Sci. Rep. 9, 17652. https:\/\/doi.org\/10.1038\/s41598-019-53472-z (2019).","journal-title":"Sci. Rep."},{"key":"58052_CR8","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-58314-1","volume":"14","author":"R Martino","year":"2024","unstructured":"Martino, R. et al. Use of the flat panel detector fluoroscope reduces radiation exposure during periacetabular osteotomy. Sci. Rep. 14, 9475. https:\/\/doi.org\/10.1038\/s41598-024-58314-1 (2024).","journal-title":"Sci. Rep."},{"key":"58052_CR9","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1097\/BRS.0b013e318275ca58","volume":"38","author":"Y Ahn","year":"2013","unstructured":"Ahn, Y., Kim, C. H., Lee, J. H., Lee, S. H. & Kim, J. S. Radiation exposure to the surgeon during percutaneous endoscopic lumbar discectomy: A prospective study. Spine 38, 617\u2013625. https:\/\/doi.org\/10.1097\/BRS.0b013e318275ca58 (2013).","journal-title":"Spine"},{"key":"58052_CR10","doi-asserted-by":"publisher","DOI":"10.3791\/69059","author":"T Kitahara","year":"2025","unstructured":"Kitahara, T. et al. Transforaminal full-endoscopic lumbar foraminotomy under local anesthesia for L5\/S1 adjacent segment foraminal stenosis. J. Vis. Exp. https:\/\/doi.org\/10.3791\/69059 (2025).","journal-title":"J. Vis. Exp."},{"key":"58052_CR11","doi-asserted-by":"publisher","first-page":"570","DOI":"10.3171\/SPI.2008.4.08182","volume":"9","author":"RK Bindal","year":"2008","unstructured":"Bindal, R. K. et al. Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion. J. Neurosurg. Spine 9, 570\u2013573. https:\/\/doi.org\/10.3171\/SPI.2008.4.08182 (2008).","journal-title":"J. Neurosurg. Spine"},{"key":"58052_CR12","doi-asserted-by":"publisher","DOI":"10.3390\/jcm13216442","volume":"13","author":"S Watanabe","year":"2024","unstructured":"Watanabe, S. et al. Investigation of radiation exposure of medical staff during lateral fluoroscopy for posterior spinal fusion surgery. J. Clin. Med. 13, 6442. https:\/\/doi.org\/10.3390\/jcm13216442 (2024).","journal-title":"J. Clin. Med."},{"key":"58052_CR13","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.OA.17.00039","volume":"2","author":"K Yamashita","year":"2017","unstructured":"Yamashita, K., Higashino, K., Hayashi, H., Hayashi, F. & Sairyo, K. Pulsation and collimation during fluoroscopy to decrease radiation: A cadaver study. JBJS Open Access 2, e0039. https:\/\/doi.org\/10.2106\/JBJS.OA.17.00039 (2017).","journal-title":"JBJS Open Access"},{"key":"58052_CR14","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1053\/j.tvir.2010.03.005","volume":"13","author":"BA Schueler","year":"2010","unstructured":"Schueler, B. A. Operator shielding: how and why. Tech Vasc Interv Radiol. 13, 167\u2013171. https:\/\/doi.org\/10.1053\/j.tvir.2010.03.005 (2010).","journal-title":"Tech Vasc Interv Radiol."},{"key":"58052_CR15","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1093\/rpd\/ncn082","volume":"129","author":"H J\u00e4rvinen","year":"2008","unstructured":"J\u00e4rvinen, H. et al. Overview of double dosimetry procedures for the determination of the effective dose to the interventional radiology staff. Radiat Prot Dosimetry. 129, 333\u2013339. https:\/\/doi.org\/10.1093\/rpd\/ncn082 (2008).","journal-title":"Radiat Prot Dosimetry."},{"key":"58052_CR16","doi-asserted-by":"publisher","first-page":"42077","DOI":"10.1038\/srep42077","volume":"7","author":"Q Jia","year":"2017","unstructured":"Jia, Q. et al. Operator radiation and the efficacy of ceiling-suspended lead screen shielding during coronary angiography: An anthropomorphic phantom study using real-time dosimeters. Sci Rep. 7, 42077. https:\/\/doi.org\/10.1038\/srep42077 (2017).","journal-title":"Sci Rep."},{"key":"58052_CR17","doi-asserted-by":"publisher","first-page":"E235","DOI":"10.1503\/cjs.003824","volume":"68","author":"J Thibault","year":"2025","unstructured":"Thibault, J., Naciri, W., Rouleau, D. M. & Chapleau, J. Intraoperative radiation exposure in a level 1 trauma centre orthopedic operating room. Can. J. Surg. 68, E235\u2013E241. https:\/\/doi.org\/10.1503\/cjs.003824 (2025).","journal-title":"Can. J. Surg."},{"key":"58052_CR18","doi-asserted-by":"publisher","first-page":"E810","DOI":"10.1002\/ccd.29223","volume":"97","author":"SB Pancholy","year":"2021","unstructured":"Pancholy, S. B. et al. Association between distance from the radiation source and radiation exposure: a phantom-based study. Catheter. Cardiovasc. Interv. 97, E810\u2013E816. https:\/\/doi.org\/10.1002\/ccd.29223 (2021).","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"58052_CR19","doi-asserted-by":"publisher","first-page":"341","DOI":"10.22603\/ssrr.2022-0184","volume":"7","author":"K Yamashita","year":"2023","unstructured":"Yamashita, K. et al. A cadaveric simulation study of radiation exposure to the surgical team during fluoroscopic spinal surgery: how much are we exposed?. Spine Surg. Relat. Res. 7, 341\u2013349. https:\/\/doi.org\/10.22603\/ssrr.2022-0184 (2023).","journal-title":"Spine Surg. Relat. Res."},{"key":"58052_CR20","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1093\/rpd\/ncn227","volume":"132","author":"A Mesbahi","year":"2008","unstructured":"Mesbahi, A. & Rouhani, A. A study on the radiation dose of the orthopaedic surgeon and staff from a mini C-arm fluoroscopy unit. Radiat. Prot. Dosimetry 132, 98\u2013101. https:\/\/doi.org\/10.1093\/rpd\/ncn227 (2008).","journal-title":"Radiat. Prot. Dosimetry"},{"key":"58052_CR21","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1007\/s11999-015-4552-4","volume":"474","author":"D Gendelberg","year":"2016","unstructured":"Gendelberg, D., Wayment, M. & Murthy, A. A radiation safety training program results in reduced radiation exposure for orthopaedic residents using the mini C-arm. Clin. Orthop. Relat. Res. 474, 580\u2013584. https:\/\/doi.org\/10.1007\/s11999-015-4552-4 (2016).","journal-title":"Clin. Orthop. Relat. Res."},{"key":"58052_CR22","doi-asserted-by":"publisher","first-page":"19319","DOI":"10.1038\/s41598-024-66698-3","volume":"14","author":"MUA Khan","year":"2024","unstructured":"Khan, M. U. A. & Yi, B. J. Real time eye dose reduction in fluoroscopy with auditory and visual feedback dosimeter through swine model experiments. Sci. Rep. 14, 19319. https:\/\/doi.org\/10.1038\/s41598-024-66698-3 (2024).","journal-title":"Sci. Rep."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-58052-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-58052-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-58052-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T23:16:24Z","timestamp":1788995784000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-58052-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,20]]},"references-count":22,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["58052"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-58052-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,20]]},"assertion":[{"value":"10 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"28298"}}