{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:50:52Z","timestamp":1792785052783,"version":"4.5.0"},"reference-count":62,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T00:00:00Z","timestamp":1783382400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:00:00Z","timestamp":1791331200000},"content-version":"vor","delay-in-days":92,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Japan Society for the Promotion of Science","award":["22H03627,23K24883"],"award-info":[{"award-number":["22H03627,23K24883"]}],"id":[{"id":"https:\/\/ror.org\/00hhkn466","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The bandwidth of voluntary upper-limb movement is constrained by the inherent transmission and processing delays of the central nervous system (CNS). While spinal reflexes exhibit shorter latencies, the maximum achievable closed-loop control bandwidth of the musculoskeletal system remains poorly defined. We address this by introducing a high-speed closed-loop electrical muscle stimulation (EMS) system. By integrating high-speed machine vision with antagonistic stimulation of the biceps and triceps via a fuzzy logic controller, this platform enables closed-loop elbow joint actuation that bypasses voluntary CNS pathways to probe the fundamental limits of neuromuscular response. In this study, the feedback control frequency was synchronized with the electrical stimulation frequency. We evaluated the system using a dynamic target-tracking task (sinusoidal reference target with\n                    <jats:inline-formula>\n                      <jats:tex-math>$$12^\\circ$$<\/jats:tex-math>\n                    <\/jats:inline-formula>\n                    amplitude and frequency from 0.2 to 0.4\u00a0Hz) involving six healthy participants across four feedback and stimulation frequencies (10, 33, 100, and 333 Hz). Performance was quantified using Dynamic Target Tracking Accuracy (DTTA-MAE) and a Neural Biceps\u2013Triceps Response model\u2019s mapping accuracy (NBTR-MAE). Our results show that both metrics improve with increasing feedback frequency. However, tracking accuracy (DTTA-MAE) exhibits no further improvement at 333 Hz compared to 100 Hz, whereas the mapping accuracy of the neural response model (NBTR-MAE) continues to improve up to 333 Hz. These findings suggest that the human neuromuscular system may adapt to and benefit from high-frequency feedback control far exceeding the rates of natural voluntary movement, providing critical insights for future applications of functional electrical stimulation (FES) systems.\n                  <\/jats:p>","DOI":"10.1038\/s41598-026-60782-6","type":"journal-article","created":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T15:36:46Z","timestamp":1783438606000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Effect of control frequency on closed-loop electrical muscle stimulation for biceps\u2013triceps in healthy participants: a pilot study"],"prefix":"10.1038","volume":"16","author":[{"given":"Yuki","family":"Kawawaki","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4605-3135","authenticated-orcid":false,"given":"Shouren","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuji","family":"Yamakawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masatoshi","family":"Ishikawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,7]]},"reference":[{"key":"60782_CR1","volume-title":"Principles of Neural Science","author":"ER Kandel","year":"2013","unstructured":"Kandel, E. R., Schwartz, J. H., Jessell, T. M., Siegelbaum, S. A. & Hudspeth, A. J. Principles of Neural Science (McGraw-Hill, 2013)."},{"key":"60782_CR2","doi-asserted-by":"publisher","first-page":"99","DOI":"10.3389\/fnint.2014.00099","volume":"8","author":"IL Kurtzer","year":"2015","unstructured":"Kurtzer, I. L. Long-latency reflexes account for limb biomechanics through several supraspinal pathways. Front. Integr. Neurosci. 8, 99. https:\/\/doi.org\/10.3389\/fnint.2014.00099 (2015).","journal-title":"Front. Integr. Neurosci."},{"key":"60782_CR3","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1186\/s12938-024-01246-8","volume":"23","author":"B Garnier","year":"2024","unstructured":"Garnier, B. et al. A novel functional electrical stimulation sleeve based on textile-embedded dry electrodes. BioMed. Eng. Online 23, 51. https:\/\/doi.org\/10.1186\/s12938-024-01246-8 (2024).","journal-title":"BioMed. Eng. Online"},{"key":"60782_CR4","doi-asserted-by":"publisher","first-page":"1272992","DOI":"10.3389\/fneur.2023.1272992","volume":"14","author":"MA Khan","year":"2023","unstructured":"Khan, M. A. et al. A systematic review on functional electrical stimulation based rehabilitation systems for upper limb post-stroke recovery. Front. Neurol. 14, 1272992. https:\/\/doi.org\/10.3389\/fneur.2023.1272992 (2023).","journal-title":"Front. Neurol."},{"key":"60782_CR5","doi-asserted-by":"publisher","first-page":"5414","DOI":"10.3390\/jcm13185414","volume":"13","author":"E Colamarino","year":"2024","unstructured":"Colamarino, E. et al. A scoping review of technology-based approaches for upper limb motor rehabilitation after stroke: Are we really targeting severe impairment?. J. Clin. Med. 13, 5414. https:\/\/doi.org\/10.3390\/jcm13185414 (2024).","journal-title":"J. Clin. Med."},{"key":"60782_CR6","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1186\/s13063-024-08199-2","volume":"25","author":"X Yang","year":"2024","unstructured":"Yang, X. et al. Effects of robot-assisted upper limb training combined with functional electrical stimulation in stroke patients: Study protocol for a randomized controlled trial. Trials 25, 355. https:\/\/doi.org\/10.1186\/s13063-024-08199-2 (2024).","journal-title":"Trials"},{"key":"60782_CR7","doi-asserted-by":"publisher","DOI":"10.3390\/s25020577","author":"X Lin","year":"2025","unstructured":"Lin, X., Hu, Y. & Sheng, Y. The effect of electrical stimulation strength training on lower limb muscle activation characteristics during the jump smash performance in badminton based on the ems and emg sensors. Sensors https:\/\/doi.org\/10.3390\/s25020577 (2025).","journal-title":"Sensors"},{"key":"60782_CR8","doi-asserted-by":"publisher","DOI":"10.3389\/frvir.2022.1000054","author":"P Lopes","year":"2022","unstructured":"Lopes, P. Editorial: Electrical stimulation for immersive virtual and augmented reality. Front. Virtual Real. https:\/\/doi.org\/10.3389\/frvir.2022.1000054 (2022).","journal-title":"Front. Virtual Real."},{"key":"60782_CR9","doi-asserted-by":"publisher","DOI":"10.3390\/mti8020007","author":"A Vrontos","year":"2024","unstructured":"Vrontos, A., Nitsch, V. & Brandl, C. Electrical muscle stimulation for kinesthetic feedback in ar\/vr: A systematic literature review. Multimodal Technol. Interact. https:\/\/doi.org\/10.3390\/mti8020007 (2024).","journal-title":"Multimodal Technol. Interact."},{"key":"60782_CR10","doi-asserted-by":"publisher","first-page":"1589","DOI":"10.1161\/01.STR.0000016926.77114.A6","volume":"33","author":"JH Cauraugh","year":"2002","unstructured":"Cauraugh, J. H. & Kim, S.-M. Two coupled motor recovery protocols are better than one: Electromyogram-triggered neuromuscular stimulation and bilateral movements. Stroke 33, 1589\u20131594. https:\/\/doi.org\/10.1161\/01.STR.0000016926.77114.A6 (2002).","journal-title":"Stroke"},{"key":"60782_CR11","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1080\/09638280701265539","volume":"30","author":"Y Hara","year":"2008","unstructured":"Hara, Y., Ogawa, S., Tsujiuchi, K. & Muraoka, Y. A home-based rehabilitation program for the hemiplegic upper extremity by power-assisted functional electrical stimulation. Disabil. Rehabil. 30, 296\u2013304. https:\/\/doi.org\/10.1080\/09638280701265539 (2008).","journal-title":"Disabil. Rehabil."},{"key":"60782_CR12","doi-asserted-by":"publisher","unstructured":"Takahashi, A., Brooks, J., Kajimoto, H. & Lopes, P. Increasing electrical muscle stimulation\u2019s dexterity by means of back of the hand actuation. CHI \u201921, (Association for Computing Machinery, New York, NY, USA, 2021) https:\/\/doi.org\/10.1145\/3411764.3445761.","DOI":"10.1145\/3411764.3445761"},{"key":"60782_CR13","doi-asserted-by":"publisher","unstructured":"Tatsuno, S., Hayakawa, T. & Ishikawa, M. Supportive training system for sports skill acquisition based on electrical stimulation. 466\u2013471, https:\/\/doi.org\/10.1109\/WHC.2017.7989946 (2017).","DOI":"10.1109\/WHC.2017.7989946"},{"key":"60782_CR14","doi-asserted-by":"publisher","unstructured":"Kasahara, S., Nishida, J. & Lopes, P. Preemptive action: Accelerating human reaction using electrical muscle stimulation without compromising agency. In Proceedings of the 2019 CHI Conference on Human Factors in Computing Systems, CHI \u201919, 1\u201315, (Association for Computing Machinery, New York, NY, USA, 2019) https:\/\/doi.org\/10.1145\/3290605.3300873.","DOI":"10.1145\/3290605.3300873"},{"key":"60782_CR15","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1016\/j.medengphy.2020.09.001","volume":"84","author":"C Chou","year":"2020","unstructured":"Chou, C. et al. Automated functional electrical stimulation training system for upper-limb function recovery in poststroke patients. Med. Eng. Phys. 84, 174\u2013183. https:\/\/doi.org\/10.1016\/j.medengphy.2020.09.001 (2020).","journal-title":"Med. Eng. Phys."},{"key":"60782_CR16","doi-asserted-by":"crossref","unstructured":"Huang, S. Experimental study on set-point regulation of human elbow joint by electric stimulation under various visual feedback rate. In Proceedings of the IEEE International Conference on Cyborg and Bionic Systems (CBS) 430\u2013434 (Shenzhen, China, 2018).","DOI":"10.1109\/CBS.2018.8612206"},{"key":"60782_CR17","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1186\/s42234-019-0034-y","volume":"5","author":"J Ciancibello","year":"2019","unstructured":"Ciancibello, J. et al. Closed-loop neuromuscular electrical stimulation using feedforward-feedback control and textile electrodes to regulate grasp force in quadriplegia. Bioelectron. Med. 5, 19 (2019).","journal-title":"Bioelectron. Med."},{"key":"60782_CR18","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1109\/TCST.2022.3207999","volume":"31","author":"Q Zhang","year":"2022","unstructured":"Zhang, Q., Lambeth, K., Iyer, A., Sun, Z. & Sharma, N. Ultrasound imaging-based closed-loop control of functional electrical stimulation for drop foot correction. IEEE Trans. Control Syst. Technol. 31, 989\u20131005 (2022).","journal-title":"IEEE Trans. Control Syst. Technol."},{"key":"60782_CR19","doi-asserted-by":"publisher","first-page":"2299","DOI":"10.1109\/TBME.2013.2253777","volume":"60","author":"Q Zhang","year":"2013","unstructured":"Zhang, Q., Hayashibe, M. & Azevedo-Coste, C. Evoked electromyography-based closed-loop torque control in functional electrical stimulation. IEEE Trans. Biomed. Eng. 60, 2299\u20132307 (2013).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"60782_CR20","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1109\/86.593285","volume":"5","author":"JJ Chen","year":"1997","unstructured":"Chen, J. J., Yu, N.-Y., Huang, D.-G., Ann, B.-T. & Chang, G.-C. Applying fuzzy logic to control cycling movement induced by functional electrical stimulation. IEEE Trans. Rehabil. Eng. 5, 158\u2013169 (1997).","journal-title":"IEEE Trans. Rehabil. Eng."},{"key":"60782_CR21","doi-asserted-by":"publisher","first-page":"63","DOI":"10.22441\/sinergi.2024.1.007","volume":"28","author":"MKI Ahmad","year":"2024","unstructured":"Ahmad, M. K. I. et al. Closed-loop functional electrical stimulation (fes) cycling rehabilitation with phase control fuzzy logic for fatigue reduction control strategies for stroke patients. SINERGI 28, 63\u201374 (2024).","journal-title":"SINERGI"},{"key":"60782_CR22","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1109\/TCST.2019.2892924","volume":"28","author":"P Paz","year":"2020","unstructured":"Paz, P., Oliveira, T. R., Pino, A. V. & Fontana, A. P. Model-free neuromuscular electrical stimulation by stochastic extremum seeking. IEEE Trans. Control Syst. Technol. 28, 238\u2013253 (2020).","journal-title":"IEEE Trans. Control Syst. Technol."},{"key":"60782_CR23","doi-asserted-by":"publisher","first-page":"1642","DOI":"10.1109\/TNSRE.2022.3183571","volume":"30","author":"N Hayami","year":"2022","unstructured":"Hayami, N. et al. Development and validation of a closed-loop functional electrical stimulation-based controller for gait rehabilitation using a finite state machine model. IEEE Trans. Neural Syst. Rehabil. Eng. 30, 1642\u20131651. https:\/\/doi.org\/10.1109\/TNSRE.2022.3183571 (2022) (Epub 2022 Jun 22.).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"60782_CR24","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1109\/86.242425","volume":"1","author":"LM Schutte","year":"1993","unstructured":"Schutte, L. M., Rodgers, M. M., Zajac, F. E. & Glaser, R. M. Improving the efficacy of electrical stimulation-induced leg cycle ergometry: An analysis based on a dynamic musculoskeletal model. IEEE Trans. Rehabil. Eng. 1, 109\u2013125 (1993).","journal-title":"IEEE Trans. Rehabil. Eng."},{"key":"60782_CR25","doi-asserted-by":"publisher","first-page":"2391","DOI":"10.1002\/rnc.3211","volume":"25","author":"I Karafyllis","year":"2015","unstructured":"Karafyllis, I., Malisoff, M., De Queiroz, M., Krstic, M. & Yang, R. Predictor-based tracking for neuromuscular electrical stimulation. Int. J. Robust Nonlinear Control 25, 2391\u20132419 (2015).","journal-title":"Int. J. Robust Nonlinear Control"},{"key":"60782_CR26","doi-asserted-by":"crossref","unstructured":"Caillet, A. H., Phillips, A. T. M., Carty, C. Farina, D. & Modenese, L Hill-type models of skeletal muscle and neuromuscular actuators: A systematic review. IEEE Rev. Biomed. Eng. (2025).","DOI":"10.1109\/RBME.2025.3593185"},{"key":"60782_CR27","doi-asserted-by":"publisher","first-page":"141277","DOI":"10.1109\/ACCESS.2019.2943453","volume":"7","author":"H Zhou","year":"2019","unstructured":"Zhou, H. et al. Estimating the ankle angle induced by fes via the neural network-based hammerstein model. IEEE Access 7, 141277\u2013141286. https:\/\/doi.org\/10.1109\/ACCESS.2019.2943453 (2019).","journal-title":"IEEE Access"},{"key":"60782_CR28","doi-asserted-by":"crossref","unstructured":"Griffis, E.\u00a0J., Isaly, A., Le, D.\u00a0M. & Dixon, W.\u00a0E. Deep neural network-based adaptive fes-cycling control: A hybrid systems approach. In 2022 IEEE 61st Conference on Decision and Control (CDC), 3262\u20133267 (IEEE, 2022).","DOI":"10.1109\/CDC51059.2022.9993025"},{"key":"60782_CR29","unstructured":"Alif, T., Mishra, S.\u00a0S., Garg, K. & Joshi, D. Electromechanical delay compensation in neuromuscular electrical stimulation via a data-driven approach: Validation in spinal cord injury patients. IEEE Transactions on Medical Robotics and Bionics (2025)."},{"key":"60782_CR30","doi-asserted-by":"publisher","unstructured":"Alahmari, S. K.\u00a0M. Muscle force production and neuromuscular fatigue responses to neuromuscular electrical stimulation and tendon vibration. Ph.D. thesis, Queensland University of Technology (2022). https:\/\/doi.org\/10.5204\/thesis.eprints.236174.","DOI":"10.5204\/thesis.eprints.236174"},{"key":"60782_CR31","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1146\/annurev.bioeng.6.040803.140103","volume":"7","author":"PH Peckham","year":"2005","unstructured":"Peckham, P. H. & Knutson, J. S. Functional electrical stimulation for neuromuscular applications. Annu. Rev. Biomed. Eng. 7, 327\u2013360. https:\/\/doi.org\/10.1146\/annurev.bioeng.6.040803.140103 (2005).","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"60782_CR32","doi-asserted-by":"publisher","first-page":"967","DOI":"10.1113\/expphysiol.2006.033886","volume":"91","author":"T Kesar","year":"2006","unstructured":"Kesar, T. & Binder-Macleod, S. Effect of frequency and pulse duration on human muscle fatigue during repetitive electrical stimulation. Exp. Physiol. 91, 967\u2013976. https:\/\/doi.org\/10.1113\/expphysiol.2006.033886 (2006).","journal-title":"Exp. Physiol."},{"key":"60782_CR33","doi-asserted-by":"publisher","DOI":"10.1016\/j.ergon.2022.103274","volume":"89","author":"C-L Lee","year":"2022","unstructured":"Lee, C.-L., Lu, S.-Y. & Wu, C.-Y. Rest period and object load effects on upper limb muscle strength recovery for manual load transfer. Int. J. Ind. Ergon. 89, 103274. https:\/\/doi.org\/10.1016\/j.ergon.2022.103274 (2022).","journal-title":"Int. J. Ind. Ergon."},{"key":"60782_CR34","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1109\/10.52333","volume":"37","author":"R Nathan","year":"1990","unstructured":"Nathan, R. & Tavi, M. The influence of stimulation pulse frequency on the generation of joint moments in the upper limb. IEEE Trans. Biomed. Eng. 37, 317\u2013322 (1990).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"60782_CR35","first-page":"35","volume":"19","author":"B Zhou","year":"2021","unstructured":"Zhou, B., Yan, H. L., Huang, L., Gao, Y. M. & Du, M. Effects of different neuromuscular electrical stimulation methods on muscle fatigue. Life Sci. Instrum. 19, 35\u201339 (2021).","journal-title":"Life Sci. Instrum."},{"key":"60782_CR36","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1109\/10.52333","volume":"37","author":"R Nathan","year":"1990","unstructured":"Nathan, R. & Tavi, M. The influence of stimulation pulse frequency on the generation of joint moments in the upper limb. IEEE Trans. Biomed. Eng. 37, 317\u2013322. https:\/\/doi.org\/10.1109\/10.52333 (1990).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"60782_CR37","doi-asserted-by":"publisher","first-page":"250","DOI":"10.5535\/arm.2018.42.2.250","volume":"42","author":"K Rongsawad","year":"2018","unstructured":"Rongsawad, K. & Ratanapinunchai, J. Effects of very high stimulation frequency and wide-pulse duration on stimulated force and fatigue of quadriceps in healthy participants. Ann. Rehabil. Med. 42, 250\u2013259. https:\/\/doi.org\/10.5535\/arm.2018.42.2.250 (2018).","journal-title":"Ann. Rehabil. Med."},{"key":"60782_CR38","doi-asserted-by":"publisher","first-page":"0124","DOI":"10.34133\/cbsystems.0124","volume":"5","author":"S Sun","year":"2024","unstructured":"Sun, S. et al. Function electrical stimulation effect on muscle fatigue based on fatigue characteristic curves of dumbbell weightlifting training. Cyborg Bionic Syst. 5, 0124. https:\/\/doi.org\/10.34133\/cbsystems.0124 (2024).","journal-title":"Cyborg Bionic Syst."},{"key":"60782_CR39","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1002\/mus.21736","volume":"42","author":"N Male\u0161evi\u0107","year":"2010","unstructured":"Male\u0161evi\u0107, N., Eng, L. & Popovi\u0107, D. Distributed low-frequency functional electrical stimulation delays muscle fatigue compared to conventional stimulation. Muscle Nerve 42, 556\u2013562. https:\/\/doi.org\/10.1002\/mus.21736 (2010).","journal-title":"Muscle Nerve"},{"key":"60782_CR40","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1007\/s00421-013-2807-4","volume":"114","author":"DG Sayenko","year":"2014","unstructured":"Sayenko, D. G., Nguyen, R., Popovic, M. R. & Masani, K. Reducing muscle fatigue during transcutaneous neuromuscular electrical stimulation by spatially and sequentially distributing electrical stimulation sources. Eur. J. Appl. Physiol. 114, 793\u2013804. https:\/\/doi.org\/10.1007\/s00421-013-2807-4 (2014).","journal-title":"Eur. J. Appl. Physiol."},{"key":"60782_CR41","doi-asserted-by":"publisher","first-page":"1174","DOI":"10.1111\/j.1525-1594.2010.01195.x","volume":"35","author":"R Nguyen","year":"2011","unstructured":"Nguyen, R., Masani, K., Micera, S., Morari, M. & Popovic, M. R. Spatially distributed sequential stimulation reduces fatigue in paralyzed triceps surae muscles: A case study. Artif. Organs 35, 1174\u20131180. https:\/\/doi.org\/10.1111\/j.1525-1594.2010.01195.x (2011).","journal-title":"Artif. Organs"},{"key":"60782_CR42","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1016\/j.jelekin.2007.01.001","volume":"18","author":"T Kesar","year":"2008","unstructured":"Kesar, T., Chou, L. W. & Binder-Macleod, S. A. Effects of stimulation frequency versus pulse duration modulation on muscle fatigue. J. Electromyogr. Kinesiol. 18, 662\u2013671. https:\/\/doi.org\/10.1016\/j.jelekin.2007.01.001 (2008).","journal-title":"J. Electromyogr. Kinesiol."},{"key":"60782_CR43","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1152\/japplphysiol.00871.2005","volume":"101","author":"ERL Baldwin","year":"2006","unstructured":"Baldwin, E. R. L., Klakowicz, P. M. & Collins, D. F. Wide-pulse-width, high-frequency neuromuscular stimulation: Implications for functional electrical stimulation. J. Appl. Physiol. 101, 228\u2013240. https:\/\/doi.org\/10.1152\/japplphysiol.00871.2005 (2006) (PMID: 16627680).","journal-title":"J. Appl. Physiol."},{"key":"60782_CR44","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1016\/0013-4694(60)90021-3","volume":"12","author":"TW Farmer","year":"1960","unstructured":"Farmer, T. W., Buchthal, F. & Rosenfalck, P. Refractory period of human muscle after the passage of a propagated action potential. Electroencephalogr. Clin. Neurophysiol. 12, 455\u2013466 (1960).","journal-title":"Electroencephalogr. Clin. Neurophysiol."},{"key":"60782_CR45","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1136\/jnnp.41.1.54","volume":"41","author":"J Kopec","year":"1978","unstructured":"Kopec, J., Delbeke, J. & McComas, A. J. Refractory period studies in a human neuromuscular preparation. J. Neurol. Neurosurg. Psychiatry 41, 54\u201364 (1978).","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"60782_CR46","doi-asserted-by":"publisher","first-page":"1858","DOI":"10.1152\/jn.1998.79.4.1858","volume":"79","author":"SA Binder-Macleod","year":"1998","unstructured":"Binder-Macleod, S. A., Lee, S. C., Fritz, A. D. & Kucharski, L. J. New look at force-frequency relationship of human skeletal muscle: Effects of fatigue. J. Neurophysiol. 79, 1858\u20131868 (1998).","journal-title":"J. Neurophysiol."},{"key":"60782_CR47","doi-asserted-by":"publisher","first-page":"1750063","DOI":"10.1142\/S0129065717500630","volume":"28","author":"Z Li","year":"2018","unstructured":"Li, Z. et al. Real-time closed-loop functional electrical stimulation control of muscle activation with evoked electromyography feedback for spinal cord injured patients. Int. J. Neural Syst. 28, 1750063. https:\/\/doi.org\/10.1142\/S0129065717500630 (2018).","journal-title":"Int. J. Neural Syst."},{"key":"60782_CR48","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1109\/TNSRE.2009.2023294","volume":"17","author":"N Sharma","year":"2009","unstructured":"Sharma, N., Stegath, K., Gregory, C. M. & Dixon, W. E. Nonlinear neuromuscular electrical stimulation tracking control of a human limb. IEEE Trans. Neural Syst. Rehabil. Eng. 17, 576\u2013584 (2009).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"60782_CR49","doi-asserted-by":"publisher","DOI":"10.3389\/fcteg.2022.910126","author":"C-H Chang","year":"2022","unstructured":"Chang, C.-H., Casas, J., Sanyal, A. K. & Duenas, V. H. Motorized fes-cycling and closed-loop nonlinear control for power tracking using a finite-time stable torque algorithm. Front. Control Eng. https:\/\/doi.org\/10.3389\/fcteg.2022.910126 (2022).","journal-title":"Front. Control Eng."},{"key":"60782_CR50","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2021.102662","volume":"68","author":"P Broniera Junior","year":"2021","unstructured":"Broniera Junior, P. et al. Eeg-fes-force-mmg closed-loop control systems of a volunteer with paraplegia considering motor imagery with fatigue recognition and automatic shut-off. Biomed. Signal Process. Control 68, 102662. https:\/\/doi.org\/10.1016\/j.bspc.2021.102662 (2021).","journal-title":"Biomed. Signal Process. Control"},{"key":"60782_CR51","doi-asserted-by":"publisher","first-page":"40895","DOI":"10.1038\/s41598-025-24831-w","volume":"15","author":"IB Abdallah","year":"2025","unstructured":"Abdallah, I. B., Bouteraa, Y. & Alotaibi, A. A hybrid emg-eeg interface for robust intention detection and fatigue-adaptive control of an elbow rehabilitation robot. Sci. Rep. 15, 40895. https:\/\/doi.org\/10.1038\/s41598-025-24831-w (2025).","journal-title":"Sci. Rep."},{"key":"60782_CR52","doi-asserted-by":"crossref","unstructured":"Kawawaki, Y., Huang, S., Yamakawa, Y. & Ishikawa, M. Rotational control of human elbow joint by electrical stimulation based on high-speed visual feedback. In Proceedings of the IEEE International Conference on Cyborg and Bionic Systems (CBS), 31\u201336 (Beijing, China, 2025).","DOI":"10.1109\/CBS65871.2025.11267683"},{"key":"60782_CR53","doi-asserted-by":"publisher","first-page":"1392","DOI":"10.1109\/21.260670","volume":"23","author":"Z-Y Zhao","year":"1993","unstructured":"Zhao, Z.-Y., Tomizuka, M. & Isaka, S. Fuzzy gain scheduling of pid controllers. IEEE Trans. Syst. Man Cybern. 23, 1392\u20131398. https:\/\/doi.org\/10.1109\/21.260670 (1993).","journal-title":"IEEE Trans. Syst. Man Cybern."},{"key":"60782_CR54","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1007\/BF00318375","volume":"55","author":"J Winters","year":"1987","unstructured":"Winters, J. & Stark, L. Muscle models: What is gained and what is lost by varying model complexity. Biol. Cybern. 55, 403\u2013420. https:\/\/doi.org\/10.1007\/BF00318375 (1987).","journal-title":"Biol. Cybern."},{"key":"60782_CR55","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1299\/jbse.4.153","volume":"4","author":"Y Moriwaki","year":"2009","unstructured":"Moriwaki, Y., Sakai, N., Sawae, Y. & Murakami, T. Development of forearm models based on human musculoskeletal system. J. Biomech. Sci. Eng. 4, 153\u2013164. https:\/\/doi.org\/10.1299\/jbse.4.153 (2009).","journal-title":"J. Biomech. Sci. Eng."},{"key":"60782_CR56","doi-asserted-by":"publisher","first-page":"3","DOI":"10.15632\/jtam-pl.53.1.3","volume":"53","author":"M Dobry","year":"2015","unstructured":"Dobry, M. & Hermann, T. A comparison of human physical models based on the distribution of power in a dynamic structure in the case of hand-arm vibrations. J. Theor. Appl. Mech. 53, 3\u201313. https:\/\/doi.org\/10.15632\/jtam-pl.53.1.3 (2015).","journal-title":"J. Theor. Appl. Mech."},{"key":"60782_CR57","unstructured":"Tone-A-Matic. Electrode placement for electric stimulation charts. https:\/\/www.toneamatic.com\/pages\/pad-placement. Accessed on April 14, 2026."},{"key":"60782_CR58","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.e4483","volume":"345","author":"P Sedgwick","year":"2012","unstructured":"Sedgwick, P. Pearson\u2019s correlation coefficient. BMJ 345, e4483. https:\/\/doi.org\/10.1136\/bmj.e4483 (2012).","journal-title":"BMJ"},{"key":"60782_CR59","unstructured":"Lu, Z. & Yuan, K.-H. Welch\u2019s t test, 1620\u20131623 (2010)."},{"key":"60782_CR60","doi-asserted-by":"publisher","first-page":"1261","DOI":"10.1016\/j.jbusres.2012.02.023","volume":"66","author":"H-C Cho","year":"2013","unstructured":"Cho, H.-C. & Abe, S. Is two-tailed testing for directional research hypotheses tests legitimate?. J. Bus. Res. 66, 1261\u20131266. https:\/\/doi.org\/10.1016\/j.jbusres.2012.02.023 (2013) (Advancing research methods in marketing.).","journal-title":"J. Bus. Res."},{"key":"60782_CR61","doi-asserted-by":"publisher","DOI":"10.7717\/peerj-cs.623","volume":"7","author":"D Chicco","year":"2021","unstructured":"Chicco, D., Warrens, M. & Jurman, G. The coefficient of determination r-squared is more informative than smape, mae, mape, mse and rmse in regression analysis evaluation. PeerJ Comput. Sci. 7, e623. https:\/\/doi.org\/10.7717\/peerj-cs.623 (2021).","journal-title":"PeerJ Comput. Sci."},{"key":"60782_CR62","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1186\/s12984-015-0022-8","volume":"12","author":"LP Paredes","year":"2015","unstructured":"Paredes, L. P., Dosen, S., Rattay, F., Graimann, B. & Farina, D. The impact of the stimulation frequency on closed-loop control with electrotactile feedback. J. NeuroEng. Rehabil. 12, 35. https:\/\/doi.org\/10.1186\/s12984-015-0022-8 (2015).","journal-title":"J. NeuroEng. Rehabil."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-60782-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-60782-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-60782-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:09:47Z","timestamp":1791331787000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-60782-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,7]]},"references-count":62,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["60782"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-60782-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,7]]},"assertion":[{"value":"22 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent was obtained from all participants involved in the study. Written informed consent has been obtained from the participants to publish this paper.","order":2,"name":"Ethics","label":"Informed consent","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"31258"}}