{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T02:14:55Z","timestamp":1783736095566,"version":"3.55.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T00:00:00Z","timestamp":1783728000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T00:00:00Z","timestamp":1783728000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004270","name":"Royal Institute of Technology","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004270","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Accurate assessment of the resection margin is of key importance for patient outcome after tumor surgery. Intraoperative assessment is preferable but present methods like fresh-frozen sectioning risk sampling errors and provide only 2D information. Classical 2D histology has better quality but is too slow for intraoperative feedback. In the present proof-of-concept study we show that laboratory x-ray histology based on propagation-based phase-contrast microtomography has potential for 3D intraoperative resection margin assessment. Our system includes a liquid\u2013metal-jet high-brightness microfocus source, precision stages and a high-resolution detector, providing fast, high-contrast, near-cellular-resolution 3D imaging. The tissue is prepared by rapid acetone fixation before the 3D x-ray imaging. We demonstrate the method on several tumor types in liver and pancreas, as well as on different sarcomas. After the x-ray histology, classical histology was performed on the same samples for comparison. The two methods compare excellently on the liver and pancreas samples and reasonably on the morphologically more difficult sarcomas. The imaging currently takes 4\u20135\u00a0h with our prototype instrument, and we outline how to go below 1\u00a0h for the full procedure. We conclude that 3D x-ray histology can be developed to provide intraoperative resection margin assessment.<\/jats:p>","DOI":"10.1038\/s41598-026-61069-6","type":"journal-article","created":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T01:33:46Z","timestamp":1783733626000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["X-ray histology on rapidly fixed fresh tumor tissue samples for fast resection margin assessment"],"prefix":"10.1038","volume":"16","author":[{"given":"Jenny","family":"Romell","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos Fernandez","family":"Moro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bertha","family":"Brodin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laszlo","family":"Szekely","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edvin","family":"Porovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Panagiotis","family":"Tsagkozis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ernesto","family":"Sparrelid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mikael","family":"Bj\u00f6rnstedt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2723-6622","authenticated-orcid":false,"given":"Hans M.","family":"Hertz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,11]]},"reference":[{"key":"61069_CR1","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1097\/SLA.0b013e31811ea962","volume":"246","author":"C Are","year":"2007","unstructured":"Are, C. et al. The impact of margins on outcome after hepatic resection for colorectal metastasis. Ann. Surg. 246, 295\u2013300 (2007).","journal-title":"Ann. Surg."},{"key":"61069_CR2","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1186\/1471-2407-8-5","volume":"8","author":"A Westgaard","year":"2008","unstructured":"Westgaard, A. et al. Resectable adenocarcinomas in the pancreatic head: The retroperitoneal resection margin is an independent prognostic factor. BMC Cancer 8, 5 (2008).","journal-title":"BMC Cancer"},{"key":"61069_CR3","first-page":"3404","volume":"8","author":"W Hu","year":"2015","unstructured":"Hu, W., Pang, X., Guo, W., Wu, L. & Zhang, B. Relationship of different surgical margins with recurrence-free survival in patients with hepatocellular carcinoma. Int. J. Clin. Exp. Pathol. 8, 3404\u20133409 (2015).","journal-title":"Int. J. Clin. Exp. Pathol."},{"key":"61069_CR4","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-018-23403-5","volume":"8","author":"RK Orosco","year":"2018","unstructured":"Orosco, R. K. et al. Positive surgical margins in the 10 most common solid cancers. Sci. Rep. 8, 5686 (2018).","journal-title":"Sci. Rep."},{"key":"61069_CR5","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1002\/ijc.33570","volume":"149","author":"J Heidkamp","year":"2021","unstructured":"Heidkamp, J. et al. Novel imaging techniques for intraoperative margin assessment in surgical oncology: A systematic review. Int. J. Cancer 149, 635\u2013645 (2021).","journal-title":"Int. J. Cancer"},{"key":"61069_CR6","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1038\/s41551-021-00808-8","volume":"6","author":"FJ Voskuil","year":"2022","unstructured":"Voskuil, F. J. et al. Intraoperative imaging in pathology-assisted surgery. Nat. Biomed. Eng. 6, 503\u2013514 (2022).","journal-title":"Nat. Biomed. Eng."},{"key":"61069_CR7","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1038\/384335a0","volume":"384","author":"S Wilkins","year":"1996","unstructured":"Wilkins, S., Gureyev, T., Gao, D., Pogany, A. & Stevenson, A. W. Phase-contrast imaging using polychromatic hard X-rays. Nature 384, 335\u2013338 (1996).","journal-title":"Nature"},{"key":"61069_CR8","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1038\/nphys265","volume":"2","author":"F Pfeiffer","year":"2006","unstructured":"Pfeiffer, F., Weitkamp, T., Bunk, O. & David, C. Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources. Nat. Phys. 2, 258\u2013261 (2006).","journal-title":"Nat. Phys."},{"key":"61069_CR9","doi-asserted-by":"publisher","first-page":"1483","DOI":"10.1063\/1.1602157","volume":"83","author":"O Hemberg","year":"2003","unstructured":"Hemberg, O., Otendal, M. & Hertz, H. M. Liquid-metal-jet anode electron-impact x-ray source. Appl. Phys. Lett. 83, 1483\u20131485 (2003).","journal-title":"Appl. Phys. Lett."},{"key":"61069_CR10","doi-asserted-by":"publisher","DOI":"10.1063\/1.2769760","volume":"91","author":"T Tuohimaa","year":"2007","unstructured":"Tuohimaa, T., Otendal, M. & Hertz, H. M. Phase-contrast x-ray imaging with a liquid-metal-jet-anode microfocus source. Appl. Phys. Lett. 91, 074104 (2007).","journal-title":"Appl. Phys. Lett."},{"key":"61069_CR11","doi-asserted-by":"publisher","first-page":"19816","DOI":"10.1039\/c3ra41372a","volume":"3","author":"I Zanette","year":"2013","unstructured":"Zanette, I., Weitkamp, T., Le Duc, G. & Pfeiffer, F. X-ray grating-based phase tomography for 3D histology. RSC Adv. 3, 19816 (2013).","journal-title":"RSC Adv."},{"key":"61069_CR12","doi-asserted-by":"publisher","first-page":"42847","DOI":"10.1038\/srep42847","volume":"7","author":"M T\u00f6pperwien","year":"2017","unstructured":"T\u00f6pperwien, M. et al. Three-dimensional mouse brain cytoarchitecture revealed by laboratory-based x-ray phase-contrast tomography. Sci. Rep. 7, 42847 (2017).","journal-title":"Sci. Rep."},{"key":"61069_CR13","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.2113835118","volume":"118","author":"M Eckermann","year":"2021","unstructured":"Eckermann, M. et al. Three-dimensional virtual histology of the human hippocampus based on phase-contrast computed tomography. Proc. Natl. Acad. Sci. U.S.A. 118, e2113835118 (2021).","journal-title":"Proc. Natl. Acad. Sci. U.S.A."},{"key":"61069_CR14","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.1038\/nprot.2014.091","volume":"9","author":"MN Holme","year":"2014","unstructured":"Holme, M. N. et al. Complementary X-ray tomography techniques for histology-validated 3D imaging of soft and hard tissues using plaque-containing blood vessels as examples. Nat. Protoc. 9, 1401\u20131415 (2014).","journal-title":"Nat. Protoc."},{"key":"61069_CR15","doi-asserted-by":"publisher","DOI":"10.1038\/srep16625","volume":"5","author":"W V\u00e5gberg","year":"2015","unstructured":"V\u00e5gberg, W., Larsson, D. H., Li, M., Arner, A. & Hertz, H. M. X-ray phase-contrast tomography for high-spatial-resolution zebrafish muscle imaging. Sci. Rep. 5, 16625 (2015).","journal-title":"Sci. Rep."},{"key":"61069_CR16","doi-asserted-by":"publisher","first-page":"11014","DOI":"10.1038\/s41598-018-29344-3","volume":"8","author":"W V\u00e5gberg","year":"2018","unstructured":"V\u00e5gberg, W., Persson, J., Szekely, L. & Hertz, H. M. Cellular-resolution 3D virtual histology of human coronary arteries using x-ray phase tomography. Sci. Rep. 8, 11014 (2018).","journal-title":"Sci. Rep."},{"key":"61069_CR17","doi-asserted-by":"publisher","first-page":"2642","DOI":"10.1109\/TMI.2018.2845905","volume":"37","author":"P Baran","year":"2018","unstructured":"Baran, P. et al. High-resolution X-ray phase-contrast 3-D imaging of breast tissue specimens as a possible adjunct to histopathology. IEEE Trans. Med. Imaging 37, 2642\u20132650 (2018).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"61069_CR18","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-83330-w","volume":"11","author":"L Massimi","year":"2021","unstructured":"Massimi, L. et al. Detection of involved margins in breast specimens with X-ray phase-contrast computed tomography. Sci. Rep. 11, 3663 (2021).","journal-title":"Sci. Rep."},{"key":"61069_CR19","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.9.3.031503","volume":"9","author":"W Twengstr\u00f6m","year":"2022","unstructured":"Twengstr\u00f6m, W. et al. Can laboratory x-ray virtual histology provide intraoperative 3D tumor resection margin assessment?. J. Med. Imag. 9, 031503 (2022).","journal-title":"J. Med. Imag."},{"key":"61069_CR20","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1159\/000442387","volume":"83","author":"M Senter-Zapata","year":"2016","unstructured":"Senter-Zapata, M. et al. The role of micro-CT in 3D histology imaging. Pathobiol. 83, 140\u2013147 (2016).","journal-title":"Pathobiol."},{"key":"61069_CR21","doi-asserted-by":"publisher","first-page":"2293","DOI":"10.1073\/pnas.1720862115","volume":"115","author":"M Busse","year":"2018","unstructured":"Busse, M. et al. \u201cThree-dimensional virtual histology enabled through cytoplasm-specific x-ray stain for microscopic and nanoscopic computed tomography. Proc. Natl. Acad. Sci. U.S.A. 115, 2293\u20132298 (2018).","journal-title":"Proc. Natl. Acad. Sci. U.S.A."},{"key":"61069_CR22","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/8617406","author":"S de Bournonville","year":"2019","unstructured":"de Bournonville, S., Vangrunderbeek, S. & Kerckhofs, G. Contras-enhances micro-CT for virtual 3D anatomical pathology of biological tissues: A literature review. Contrast Media&Molec. Im. https:\/\/doi.org\/10.1155\/2019\/8617406 (2019).","journal-title":"Contrast Media&Molec. Im."},{"key":"61069_CR23","unstructured":"Hertz, H. M., Romell, J., Moro, C. F. & Lagerqvist, F. Patent application WO\/2024\/217666 \u201cResection Margin Assessment\u201d; H.M. Hertz, J. Romell, Patent application no. WO\/2025\/056616: \u201cTissue Fixation and Imaging\u201d."},{"key":"61069_CR24","first-page":"394","volume":"68","author":"F Bray","year":"2018","unstructured":"Bray, F., Ferley, J., Soerjomataram, I., Siegel, R. L. & Torre, L. A. A, Jemal, Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J. Clin. 68, 394\u2013424 (2018).","journal-title":"CA Cancer J. Clin."},{"key":"61069_CR25","doi-asserted-by":"publisher","first-page":"2008","DOI":"10.1016\/S0140-6736(20)30974-0","volume":"39","author":"JD Mizrahi","year":"2020","unstructured":"Mizrahi, J. D., Surana, R., Valle, J. W. & Shroff, R. T. Pancreatic cancer. Lancet 39, 2008\u20132020 (2020).","journal-title":"Lancet"},{"key":"61069_CR26","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1097\/MPA.0000000000001189","volume":"48","author":"BDO Batukbhai","year":"2019","unstructured":"Batukbhai, B. D. O. & De Jesus-Acosta, A. The molecular and clinical landscape of pancreatic neuroendocrine tumors. Pancreas 48, 9\u201321 (2019).","journal-title":"Pancreas"},{"key":"61069_CR27","unstructured":"WHO Classification of Tumours (5th edition), Volume 3: Soft Tissue and Bone Tumours. (IARC Press, 2020)."},{"key":"61069_CR28","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1002\/bjs.5906","volume":"95","author":"M Sampo","year":"2008","unstructured":"Sampo, M. et al. Impact of the smallest surgical margin on local control in soft tissue sarcoma. Br. J. Surg. 95, 237\u2013243 (2008).","journal-title":"Br. J. Surg."},{"key":"61069_CR29","doi-asserted-by":"publisher","first-page":"506","DOI":"10.1097\/SLA.0b013e3181cf87fa","volume":"251","author":"A Gronchi","year":"2010","unstructured":"Gronchi, A. et al. Extremity soft tissue sarcoma in a series of patients treated at a single institution: local control directly impacts survival. Ann. Surg. 251, 506\u2013511 (2010).","journal-title":"Ann. Surg."},{"key":"61069_CR30","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1046\/j.1365-2818.2002.01046.x","volume":"207","author":"SC Mayo","year":"2002","unstructured":"Mayo, S. C. et al. Quantitative X-ray projection microscopy: phase-contrast and multi-spectral imaging. J. Microsc. 207, 79\u201396 (2002).","journal-title":"J. Microsc."},{"key":"61069_CR31","doi-asserted-by":"publisher","first-page":"30183","DOI":"10.1364\/OE.21.030183","volume":"21","author":"T Zhou","year":"2013","unstructured":"Zhou, T. et al. Comparison of two x-ray phase-contrast imaging methods with a microfocus source. Opt. Express 21, 30183\u201330195 (2013).","journal-title":"Opt. Express"},{"key":"61069_CR32","doi-asserted-by":"publisher","first-page":"10359","DOI":"10.1364\/OE.19.010359","volume":"19","author":"A Burvall","year":"2011","unstructured":"Burvall, A., Lundstr\u00f6m, U., Takman, P. A. C., Larsson, D. H. & Hertz, H. M. Phase retrieval in X-ray phase-contrast imaging suitable for tomography. Opt. Expr. 19, 10359\u201310376 (2011).","journal-title":"Opt. Expr."},{"key":"61069_CR33","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1046\/j.1365-2818.2002.01010.x","volume":"206","author":"D Paganin","year":"2002","unstructured":"Paganin, D., Mayo, S. C., Gureyev, T. E., Miller, P. R. & Wilkins, S. W. Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object. J. Microsc. 206, 33\u201340 (2002).","journal-title":"J. Microsc."},{"key":"61069_CR34","doi-asserted-by":"publisher","first-page":"23191","DOI":"10.1364\/OE.25.023191","volume":"25","author":"W V\u00e5gberg","year":"2017","unstructured":"V\u00e5gberg, W., Larsson, J. L., Hertz, H. M. & Hertz, H. M. Removal of ring artifacts in microtomography by characterization of scintillator variations. Opt. Express 25, 23191\u201323198 (2017).","journal-title":"Opt. Express"},{"key":"61069_CR35","doi-asserted-by":"publisher","first-page":"8567","DOI":"10.1364\/OE.17.008567","volume":"17","author":"B M\u00fcnch","year":"2009","unstructured":"M\u00fcnch, B., Trtik, P., Marone, F. & Stampanoni, M. Stripe and ring artifact removal with combined wavelet-Fourier filtering. Opt. Express 17, 8567\u20138591 (2009).","journal-title":"Opt. Express"},{"key":"61069_CR36","doi-asserted-by":"publisher","first-page":"28396","DOI":"10.1364\/OE.26.028396","volume":"26","author":"NY Vo","year":"2018","unstructured":"Vo, N. Y., Atwood, R. C. & Drakopoulos, M. Superior techniques for eliminating ring artifacts in X-ray micro-tomography. Opt. Express 26, 28396\u201328412 (2018).","journal-title":"Opt. Express"},{"key":"61069_CR37","doi-asserted-by":"publisher","DOI":"10.1118\/1.4790697","volume":"40","author":"Y Zhu","year":"2013","unstructured":"Zhu, Y., Zhao, M., Li, H. & Zhang, P. Micro-CT artifacts reduction based on detector random shifting and fast data inpainting. Med. Phys. 40, 031114 (2013).","journal-title":"Med. Phys."},{"key":"61069_CR38","doi-asserted-by":"publisher","first-page":"27975","DOI":"10.1364\/OE.23.027975","volume":"23","author":"V van Nieuwenhove","year":"2015","unstructured":"van Nieuwenhove, V. et al. Dynamic intensity normalization using eigen flat fields in X-ray imaging. Opt. Expr. 23, 27975\u201327989 (2015).","journal-title":"Opt. Expr."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-61069-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-61069-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-61069-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T01:45:47Z","timestamp":1783734347000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-61069-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,11]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["61069"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-61069-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,11]]},"assertion":[{"value":"23 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"HMH is a co-founder and shareholder of Excillum. HMH, JR, and CFM are inventors on patent applications. The other authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"21642"}}