{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T23:53:08Z","timestamp":1791503588067,"version":"4.3.4"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T00:00:00Z","timestamp":1783555200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T00:00:00Z","timestamp":1791504000000},"content-version":"vor","delay-in-days":92,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100007816","name":"Alcon","doi-asserted-by":"publisher","award":["88660287"],"award-info":[{"award-number":["88660287"]}],"id":[{"id":"10.13039\/100007816","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The predictive modeling of postoperative mechanical complications, such as the early micro-rotation of premium toric intraocular lenses (IOLs), is severely hindered by the extreme imbalance of clinical datasets. Traditional statistical methods often fail to capture complex biomechanical interactions in rare-event scenarios. This exploratory pilot study introduces a machine learning framework designed as a hypothesis-generating tool to handle extremely imbalanced ophthalmic data and identify potential preoperative biometric features associated with toric IOL micro-rotation. A prospective cohort of 35 eyes implanted with the Clareon PanOptix\u00ae Toric IOL was analyzed, quantifying true rotational stability via high-resolution photographic registration. Given the exceedingly low incidence of\u2009&gt;\u20091-degree micro-rotation, a strict, leak-proof fivefold cross-validation pipeline was established. The Synthetic Minority Over-sampling Technique (SMOTE) was applied exclusively within the training folds, and an interpretable Linear Support Vector Machine (Linear SVM) was deployed to extract robust feature weights for biomechanical interpretation. Our findings highlight the \u201caccuracy paradox\u201d in small clinical datasets: complex ensemble models exhibited severe majority-class bias, failing to detect rare micro-rotations. Conversely, the SMOTE-enhanced Linear SVM achieved a Precision-Recall Area Under the Curve (PR-AUC) of 0.463, outperforming a random baseline by nearly a factor of three. The algorithmic feature weights successfully isolated Anterior Chamber Depth (ACD) and steep keratometry (Steep K2) as the primary geometric drivers of rotational instability, demonstrating a profound alignment with clinical ocular biomechanics. While strictly constrained by the small sample size (N\u2009=\u200935) and limited event rate, this preliminary pilot framework successfully bridges high-dimensional data augmentation with physical ocular biomechanics, effectively identifying minority risk features and laying the groundwork for future AI-driven surgical navigation systems.<\/jats:p>","DOI":"10.1038\/s41598-026-61984-8","type":"journal-article","created":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T17:33:13Z","timestamp":1783618393000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["An exploratory SMOTE-SVM approach for identifying preoperative biomechanical risk factors driving early toric intraocular lens micro-rotation in extremely imbalanced cohorts"],"prefix":"10.1038","volume":"16","author":[{"given":"Kuo-Chi","family":"Hung","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pi-Jung","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tzyy-Chang","family":"Ho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin-Siang","family":"Shaw","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,9]]},"reference":[{"key":"61984_CR1","first-page":"112","volume":"41","author":"A Saad","year":"2025","unstructured":"Saad, A. & Breyer, D. R. Advanced techniques in refractive cataract surgery (RCS): Achieving spectacle independence with precision technology. J. Refract. Surg. 41, 112\u2013120 (2025).","journal-title":"J. Refract. Surg."},{"key":"61984_CR2","first-page":"10","volume":"52","author":"A Campa\u00f1a-Le\u00f3n","year":"2024","unstructured":"Campa\u00f1a-Le\u00f3n, A. Rotational stability, centration, and patient satisfaction with the Clareon PanOptix Toric intraocular lens. J. Cataract Refract. Surg. 52, 10\u20131097 (2024).","journal-title":"J. Cataract Refract. Surg."},{"key":"61984_CR3","first-page":"2750","volume":"68","author":"M Kaur","year":"2020","unstructured":"Kaur, M., Ribeiro, E. N. & Agrawal, V. Commentary: Toric intraocular lens alignment: Going markerless. Indian J. Ophthalmol. 68, 2750\u20132751 (2020).","journal-title":"Indian J. Ophthalmol."},{"key":"61984_CR4","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S441524","author":"EH Hu","year":"2023","unstructured":"Hu, E. H. Repositioning rates of Toric IOLs implanted in cataract surgery patients: A retrospective chart review. Clin. Ophthalmol. https:\/\/doi.org\/10.2147\/OPTH.S441524 (2023).","journal-title":"Clin. Ophthalmol."},{"key":"61984_CR5","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/j.jcrs.2014.04.030","volume":"41","author":"O Findl","year":"2015","unstructured":"Findl, O., Hirnschall, N., Nishi, Y., Maurino, V. & Crnej, A. Capsular bag performance of a hydrophobic acrylic 1-piece intraocular lens. J. Cataract Refract. Surg. 41, 90\u201397 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"61984_CR6","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2023.1306276","volume":"10","author":"Z Huang","year":"2024","unstructured":"Huang, Z. et al. The relationships between lens diameter and ocular biometric parameters: An ultrasound biomicroscopy-based study. Front. Med. 10, 1306276 (2024).","journal-title":"Front. Med."},{"key":"61984_CR7","doi-asserted-by":"publisher","first-page":"1842","DOI":"10.1016\/j.jcrs.2008.07.012","volume":"34","author":"DF Chang","year":"2008","unstructured":"Chang, D. F. Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses. J. Cataract Refract. Surg. 34, 1842\u20131847 (2008).","journal-title":"J. Cataract Refract. Surg."},{"key":"61984_CR8","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1167\/tvst.14.11.12","volume":"14","author":"Y Lin","year":"2025","unstructured":"Lin, Y. Artificial intelligence prediction of postoperative rotation stability after toric implantable Collamer lens implantation. Transl. Vis. Sci. Technol. 14, 12 (2025).","journal-title":"Transl. Vis. Sci. Technol."},{"key":"61984_CR9","unstructured":"Shariati, M. M. & Darvish, A. Clinical decision support systems in ophthalmology: A systematic search and a narrative review. Appl. Med. Inf. 46 (2024)."},{"key":"61984_CR10","doi-asserted-by":"publisher","DOI":"10.3390\/jcm13020498","volume":"13","author":"W Stopyra","year":"2024","unstructured":"Stopyra, W., Cooke, D. L. & Grzybowski, A. A review of intraocular lens power calculation formulas based on artificial intelligence. J. Clin. Med. 13, 498 (2024).","journal-title":"J. Clin. Med."},{"key":"61984_CR11","doi-asserted-by":"publisher","first-page":"13686","DOI":"10.1109\/ACCESS.2025.3531662","volume":"13","author":"M Altalhan","year":"2025","unstructured":"Altalhan, M., Algarni, A. & Alouane, M.T.-H. Imbalanced data problem in machine learning: A review. IEEE Access 13, 13686\u201313699 (2025).","journal-title":"IEEE Access"},{"key":"61984_CR12","doi-asserted-by":"publisher","DOI":"10.7717\/peerj-cs.670","volume":"7","author":"M Dorn","year":"2021","unstructured":"Dorn, M. et al. Comparison of machine learning techniques to handle imbalanced COVID-19 CBC datasets. PeerJ Comput. Sci. 7, e670 (2021).","journal-title":"PeerJ Comput. Sci."},{"key":"61984_CR13","doi-asserted-by":"publisher","DOI":"10.3390\/cancers16193417","volume":"16","author":"F Gurcan","year":"2024","unstructured":"Gurcan, F. & Soylu, A. Learning from imbalanced data: Integration of advanced resampling techniques and machine learning models for enhanced cancer diagnosis and prognosis. Cancers 16, 3417 (2024).","journal-title":"Cancers"},{"key":"61984_CR14","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1613\/jair.953","volume":"16","author":"NV Chawla","year":"2002","unstructured":"Chawla, N. V., Bowyer, K. W., Hall, L. O. & Kegelmeyer, W. P. SMOTE synthetic minority over-sampling technique. J. Artif. Intell. Res. 16, 321\u2013357 (2002).","journal-title":"J. Artif. Intell. Res."},{"key":"61984_CR15","doi-asserted-by":"publisher","first-page":"429","DOI":"10.3233\/IDA-2002-6504","volume":"6","author":"N Japkowicz","year":"2002","unstructured":"Japkowicz, N. & Stephen, S. The class imbalance problem: A systematic study. Intell. Data Anal. 6, 429\u2013449 (2002).","journal-title":"Intell. Data Anal."},{"key":"61984_CR16","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1136\/bjophthalmol-2018-313173","volume":"103","author":"DSW Ting","year":"2019","unstructured":"Ting, D. S. W. et al. Artificial intelligence and deep learning in ophthalmology. Br. J. Ophthalmol. 103, 167\u2013175 (2019).","journal-title":"Br. J. Ophthalmol."},{"key":"61984_CR17","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1016\/j.eswa.2016.12.035","volume":"73","author":"G Haixiang","year":"2017","unstructured":"Haixiang, G. et al. Learning from class-imbalanced data: Review of methods and applications. Expert Syst. Appl. 73, 220\u2013239 (2017).","journal-title":"Expert Syst. Appl."},{"key":"61984_CR18","doi-asserted-by":"crossref","unstructured":"Davis, J. & Goadrich, M. The relationship between precision-recall and ROC curves. In Proceedings of the 23rd International Conference on Machine Learning (ICML 2006), 233\u2013240 (ACM, 2006).","DOI":"10.1145\/1143844.1143874"},{"key":"61984_CR19","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1097\/j.jcrs.0000000000000478","volume":"47","author":"J Zdral","year":"2021","unstructured":"Zdral, J. et al. Rotational stability of toric intraocular lenses with a newly modified capsular tension ring. J. Cataract Refract. Surg. 47, 516\u2013521 (2021).","journal-title":"J. Cataract Refract. Surg."},{"key":"61984_CR20","first-page":"32","volume":"112","author":"A Viestenz","year":"2005","unstructured":"Viestenz, A., Seitz, B. & Langenbucher, A. Evaluating the eye\u2019s rotational stability during standard cataract surgery. Ophthalmology 112, 32\u201340 (2005).","journal-title":"Ophthalmology"},{"key":"61984_CR21","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1111\/j.1442-9071.2008.01708.x","volume":"36","author":"JH Kim","year":"2008","unstructured":"Kim, J. H., Lee, D., Cha, Y. D. & Kim, C. Y. The analysis of predicted capsular bag diameter using modified model of capsule measuring ring in Asians. Clin. Exper. Ophthalmol. 36, 238\u2013244. https:\/\/doi.org\/10.1111\/j.1442-9071.2008.01708.x (2008).","journal-title":"Clin. Exper. Ophthalmol."},{"key":"61984_CR22","first-page":"221","volume":"8","author":"AG Lalkhen","year":"2008","unstructured":"Lalkhen, A. G. & McCluskey, A. Clinical tests: Sensitivity and specificity. Contin. Educ. Anaesth. Crit. Care Pain 8, 221\u2013223 (2008).","journal-title":"Contin. Educ. Anaesth. Crit. Care Pain"},{"key":"61984_CR23","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1007\/978-3-031-50666-6_19","volume-title":"Intraocular Lens Calculations","author":"HJ Shammas","year":"2024","unstructured":"Shammas, H. J. & Shammas, M. C. Biometry measurements using a new large coherence length swept-source optical coherence tomography: Clinical experience with the Argos biometer. In Intraocular Lens Calculations 313\u2013320 (Springer, 2024)."},{"key":"61984_CR24","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1159\/000496690","volume":"62","author":"A Tamaoki","year":"2019","unstructured":"Tamaoki, A. et al. Clinical evaluation of a new swept-source optical coherence biometer that uses individual refractive indices to measure axial length in cataract patients. Ophthalmic Res. 62, 11\u201323 (2019).","journal-title":"Ophthalmic Res."},{"key":"61984_CR25","doi-asserted-by":"publisher","first-page":"3020","DOI":"10.4103\/ijo.IJO_465_20","volume":"68","author":"SK Kodavoor","year":"2020","unstructured":"Kodavoor, S. K. et al. Randomized trial comparing visual outcomes of toric intraocular lens implantation using manual and digital marker. Indian J. Ophthalmol. 68, 3020\u20133024 (2020).","journal-title":"Indian J. Ophthalmol."},{"key":"61984_CR26","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1136\/bjophthalmol-2017-311797","volume":"103","author":"D Schartm\u00fcller","year":"2019","unstructured":"Schartm\u00fcller, D., Schriefl, S., Schwarzenbacher, L., Leydolt, C. & Menapace, R. True rotational stability of a single-piece hydrophobic intraocular lens. Br. J. Ophthalmol. 103, 186\u2013190 (2019).","journal-title":"Br. J. Ophthalmol."},{"key":"61984_CR27","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0118432","volume":"10","author":"T Saito","year":"2015","unstructured":"Saito, T. & Rehmsmeier, M. The precision-recall plot is more informative than the ROC plot when evaluating binary classifiers on imbalanced datasets. PLoS ONE 10, e0118432 (2015).","journal-title":"PLoS ONE"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-61984-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-61984-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-61984-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T23:35:46Z","timestamp":1791502546000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-61984-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,9]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["61984"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-61984-8","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,9]]},"assertion":[{"value":"23 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"31599"}}