{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T09:01:18Z","timestamp":1784710878312,"version":"3.55.0"},"reference-count":60,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T00:00:00Z","timestamp":1784678400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T00:00:00Z","timestamp":1784678400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009534","name":"Universit\u00e4t Stuttgart","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100009534","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Accurate in vivo characterization of skeletal muscle structure is essential for understanding muscle function, assessing pathologies, and developing musculoskeletal models. Magnetic resonance imaging (MRI) and diffusion MRI enable visualization of muscle morphology and fibre architecture in vivo, but imaging skeletal muscles often requires an extended field of view. At large distances from the magnet isocentre, gradient non-linearities and magnetic field inhomogeneities can cause severe image distortions. Here, we present multi-stack structural and diffusion-tensor echo-planar images of the lower limb using selected stack lengths and acquisition parameters to provide realistic examples. Geometric distortions, fractional anisotropy maps, and tractography-reconstructed fibre tracts are used to demonstrate anatomical plausibility and consistency across overlapping slices. In the presented examples, pronounced distortions, compromised fat suppression, and fibre reconstruction errors are observed under off-isocentre imaging conditions. While shorter stack lengths may help reduce distortions, our examples also indicate that factors such as shimming strategy, participant positioning, and post-processing can influence image quality. Our work highlights key pitfalls in muscle diffusion MRI, providing practical guidance grounded in MRI physics to support the design of multi-stack MRI protocols. These considerations support more reliable multi-stack diffusion MRI for musculoskeletal research and biomechanical modelling.<\/jats:p>","DOI":"10.1038\/s41598-026-63269-6","type":"journal-article","created":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T06:45:28Z","timestamp":1784702728000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Overcoming pitfalls in multi-stack diffusion MRI for tractography reconstruction of skeletal muscles"],"prefix":"10.1038","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2405-863X","authenticated-orcid":false,"given":"Manuela","family":"Zimmer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geoffrey","family":"Handsfield","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Condron","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samantha","family":"Holdsworth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Flavio","family":"Dell\u2019Acqua","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Filiz","family":"Ate\u015f","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,22]]},"reference":[{"key":"63269_CR1","doi-asserted-by":"publisher","first-page":"20150084","DOI":"10.1098\/rsfs.2015.0084","volume":"6","author":"J Fernandez","year":"2016","unstructured":"Fernandez, J. et al. Multiscale musculoskeletal modelling, data\u2013model fusion and electromyography-informed modelling. Interface Focus. 6, 20150084 (2016).","journal-title":"Interface Focus"},{"key":"63269_CR2","doi-asserted-by":"publisher","first-page":"685531","DOI":"10.3389\/fphys.2021.685531","volume":"12","author":"T Klotz","year":"2021","unstructured":"Klotz, T., Bleiler, C. & R\u00f6hrle, O. A. Physiology-Guided Classification of Active-Stress and Active-Strain Approaches for Continuum-Mechanical Modeling of Skeletal Muscle Tissue. Front. Physiol. 12, 685531 (2021).","journal-title":"Front. Physiol."},{"key":"63269_CR3","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1016\/j.jbiomech.2013.12.002","volume":"47","author":"GG Handsfield","year":"2014","unstructured":"Handsfield, G. G., Meyer, C. H., Hart, J. M., Abel, M. F. & Blemker, S. S. Relationships of 35 lower limb muscles to height and body mass quantified using MRI. J. Biomech. 47, 631\u2013638 (2014).","journal-title":"J. Biomech."},{"key":"63269_CR4","unstructured":"Dell\u2019Acqua, F., Descoteaux, M. & Leemans, A. Handbook of Diffusion MR Tractography: Imaging Methods, Biophysical Models, Algorithms and Applications (Elsevier, 2024)."},{"key":"63269_CR5","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1002\/mrm.10198","volume":"48","author":"BM Damon","year":"2002","unstructured":"Damon, B. M., Ding, Z., Anderson, A. W., Freyer, A. S. & Gore, J. C. Validation of diffusion tensor MRI-based muscle fiber tracking. Magn. Reson. Med. 48, 97\u2013104 (2002).","journal-title":"Magn. Reson. Med."},{"key":"63269_CR6","doi-asserted-by":"publisher","first-page":"e3563","DOI":"10.1002\/nbm.3563","volume":"30","author":"BM Damon","year":"2017","unstructured":"Damon, B. M. et al. Skeletal muscle diffusion tensor-MRI fiber tracking: rationale, data acquisition and analysis methods, applications and future directions. NMR Biomed. 30, e3563 (2017).","journal-title":"NMR Biomed."},{"key":"63269_CR7","doi-asserted-by":"publisher","first-page":"126","DOI":"10.3389\/fbioe.2018.00126","volume":"6","author":"E Ramasamy","year":"2018","unstructured":"Ramasamy, E. et al. An efficient modelling-simulation-analysis workflow to investigate stump-socket interaction using patient-specific, three-dimensional, continuum-mechanical, finite element residual limb models. Front. Bioeng. Biotechnol. 6, 126 (2018).","journal-title":"Front. Bioeng. Biotechnol."},{"key":"63269_CR8","doi-asserted-by":"publisher","first-page":"3592","DOI":"10.1016\/j.jbiomech.2016.09.014","volume":"49","author":"R Kinugasa","year":"2016","unstructured":"Kinugasa, R., Yamamura, N., Sinha, S. & Takagi, S. Influence of intramuscular fiber orientation on the Achilles tendon curvature using three-dimensional finite element modeling of contracting skeletal muscle. J. Biomech. 49, 3592\u20133595 (2016).","journal-title":"J. Biomech."},{"key":"63269_CR9","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/j.jtbi.2014.10.036","volume":"365","author":"AM Z\u00f6llner","year":"2015","unstructured":"Z\u00f6llner, A. M., Pok, J. M., McWalter, E. J., Gold, G. E. & Kuhl, E. On high heels and short muscles: A multiscale model for sarcomere loss in the gastrocnemius muscle. J. Theor. Biol. 365, 301\u2013310 (2015).","journal-title":"J. Theor. Biol."},{"key":"63269_CR10","doi-asserted-by":"publisher","first-page":"1845","DOI":"10.1007\/s10237-017-0923-5","volume":"16","author":"GG Handsfield","year":"2017","unstructured":"Handsfield, G. G. et al. Determining skeletal muscle architecture with Laplacian simulations: a comparison with diffusion tensor imaging. Biomech. Model. Mechanobiol. 16, 1845\u20131855 (2017).","journal-title":"Biomech. Model. Mechanobiol."},{"key":"63269_CR11","doi-asserted-by":"publisher","first-page":"110877","DOI":"10.1016\/j.jbiomech.2021.110877","volume":"130","author":"KR Knaus","year":"2022","unstructured":"Knaus, K. R., Handsfield, G. G. & Blemker, S. S. A 3D model of the soleus reveals effects of aponeuroses morphology and material properties on complex muscle fascicle behavior. J. Biomech. 130, 110877 (2022).","journal-title":"J. Biomech."},{"key":"63269_CR12","doi-asserted-by":"publisher","first-page":"1639","DOI":"10.1007\/s00256-023-04350-3","volume":"52","author":"T Mart\u00edn-Noguerol","year":"2023","unstructured":"Mart\u00edn-Noguerol, T., Barousse, R., Wessell, D. E., Rossi, I. & Luna, A. Clinical applications of skeletal muscle diffusion tensor imaging. Skeletal Radiol. 52, 1639\u20131649 (2023).","journal-title":"Skeletal Radiol."},{"key":"63269_CR13","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1002\/jmri.29489","volume":"61","author":"DB Berry","year":"2025","unstructured":"Berry, D. B., Gordon, J. A., Adair, V., Frank, L. R. & Ward, S. R. From Voxels to Physiology: A Review of Diffusion Magnetic Resonance Imaging Applications in Skeletal Muscle. J. Magn. Reson. Imaging. 61, 595\u2013615 (2025).","journal-title":"J. Magn. Reson. Imaging"},{"key":"63269_CR14","doi-asserted-by":"publisher","first-page":"1339","DOI":"10.1002\/nbm.2959","volume":"26","author":"M Froeling","year":"2013","unstructured":"Froeling, M., Nederveen, A. J., Nicolay, K. & Strijkers, G. J. DTI of human skeletal muscle: the effects of diffusion encoding parameters, signal-to-noise ratio and T2 on tensor indices and fiber tracts. NMR Biomed. 26, 1339\u20131352 (2013).","journal-title":"NMR Biomed."},{"key":"63269_CR15","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1118\/1.595732","volume":"12","author":"M O\u2019Donnell","year":"1985","unstructured":"O\u2019Donnell, M. & Edelstein, W. A. NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities: MRI in the presence of field inhomogeneities and gradient nonlinearities. Med. Phys. 12, 20\u201326 (1985).","journal-title":"Med. Phys."},{"key":"63269_CR16","doi-asserted-by":"publisher","first-page":"116127","DOI":"10.1016\/j.neuroimage.2019.116127","volume":"205","author":"HY Mesri","year":"2020","unstructured":"Mesri, H. Y., David, S., Viergever, M. A. & Leemans, A. The adverse effect of gradient nonlinearities on diffusion MRI: From voxels to group studies. NeuroImage 205, 116127 (2020).","journal-title":"NeuroImage"},{"key":"63269_CR17","unstructured":"Glover, G. H. & Pelc, N. J. Method for correcting image distortion due to gradient nonuniformity. (1986)."},{"key":"63269_CR18","doi-asserted-by":"publisher","first-page":"1343","DOI":"10.1088\/0031-9155\/50\/7\/001","volume":"50","author":"SJ Doran","year":"2005","unstructured":"Doran, S. J., Charles-Edwards, L., Reinsberg, S. A. & Leach, M. O. A complete distortion correction for MR images: I. Gradient warp correction. Phys. Med. Biol. 50, 1343\u20131361 (2005).","journal-title":"Phys. Med. Biol."},{"key":"63269_CR19","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1002\/mrm.10545","volume":"50","author":"R Bammer","year":"2003","unstructured":"Bammer, R. et al. Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion-weighted imaging. Magn. Reson. Med. 50, 560\u2013569 (2003).","journal-title":"Magn. Reson. Med."},{"key":"63269_CR20","doi-asserted-by":"publisher","first-page":"L55","DOI":"10.1088\/0022-3719\/10\/3\/004","volume":"10","author":"P Mansfield","year":"1977","unstructured":"Mansfield, P. Multi-planar image formation using NMR spin echoes. J. Phys. C Solid State Phys. 10, L55\u2013L58 (1977).","journal-title":"J. Phys. C Solid State Phys."},{"key":"63269_CR21","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1016\/j.neuroimage.2015.10.019","volume":"125","author":"JLR Andersson","year":"2016","unstructured":"Andersson, J. L. R. & Sotiropoulos, S. N. An integrated approach to correction for off-resonance effects and subject movement in diffusion MR imaging. NeuroImage 125, 1063\u20131078 (2016).","journal-title":"NeuroImage"},{"key":"63269_CR22","doi-asserted-by":"publisher","first-page":"N253","DOI":"10.1088\/0031-9155\/51\/12\/N04","volume":"51","author":"CP Karger","year":"2006","unstructured":"Karger, C. P., H\u00f6ss, A., Bendl, R., Canda, V. & Schad, L. Accuracy of device-specific 2D and 3D image distortion correction algorithms for magnetic resonance imaging of the head provided by a manufacturer. Phys. Med. Biol. 51, N253\u2013N261 (2006).","journal-title":"Phys. Med. Biol."},{"key":"63269_CR23","doi-asserted-by":"publisher","first-page":"821","DOI":"10.1002\/(SICI)1522-2586(199906)9:6<821::AID-JMRI9>3.0.CO;2-2","volume":"9","author":"S Langlois","year":"1999","unstructured":"Langlois, S., Desvignes, M., Constans, J. M. & Revenu, M. MRI geometric distortion: A simple approach to correcting the effects of non-linear gradient fields. J. Magn. Reson. Imaging. 9, 821\u2013831 (1999).","journal-title":"J. Magn. Reson. Imaging"},{"key":"63269_CR24","doi-asserted-by":"publisher","first-page":"e4130","DOI":"10.1002\/nbm.4130","volume":"32","author":"K Borkowski","year":"2019","unstructured":"Borkowski, K. & Krzy\u017cak, A. T. Assessment of the systematic errors caused by diffusion gradient inhomogeneity in DTI-computer simulations. NMR Biomed. 32, e4130 (2019).","journal-title":"NMR Biomed."},{"key":"63269_CR25","doi-asserted-by":"publisher","first-page":"e0223531","DOI":"10.1371\/journal.pone.0223531","volume":"14","author":"JP Charles","year":"2019","unstructured":"Charles, J. P., Suntaxi, F. & Anderst, W. J. In vivo human lower limb muscle architecture dataset obtained using diffusion tensor imaging. PLOS ONE. 14, e0223531 (2019).","journal-title":"PLOS ONE"},{"key":"63269_CR26","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1152\/japplphysiol.00290.2007","volume":"103","author":"DA Lansdown","year":"2007","unstructured":"Lansdown, D. A., Ding, Z., Wadington, M., Hornberger, J. L. & Damon, B. M. Quantitative diffusion tensor MRI-based fiber tracking of human skeletal muscle. J. Appl. Physiol. 103, 673\u2013681 (2007).","journal-title":"J. Appl. Physiol."},{"key":"63269_CR27","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1002\/mrm.21819","volume":"61","author":"AM Heemskerk","year":"2009","unstructured":"Heemskerk, A. M., Sinha, T. K., Wilson, K. J., Ding, Z. & Damon, B. M. Quantitative assessment of DTI-based muscle fiber tracking and optimal tracking parameters. Magn. Reson. Med. 61, 467\u2013472 (2009).","journal-title":"Magn. Reson. Med."},{"key":"63269_CR28","doi-asserted-by":"publisher","first-page":"e4430","DOI":"10.1002\/nbm.4430","volume":"34","author":"J Forsting","year":"2021","unstructured":"Forsting, J., Rehmann, R., Rohm, M., Froeling, M. & Schlaffke, L. Evaluation of interrater reliability of different muscle segmentation techniques in diffusion tensor imaging. NMR Biomed. 34, e4430 (2021).","journal-title":"NMR Biomed."},{"key":"63269_CR29","doi-asserted-by":"publisher","first-page":"e0205944","DOI":"10.1371\/journal.pone.0205944","volume":"14","author":"AS Sahrmann","year":"2019","unstructured":"Sahrmann, A. S., Stott, N. S., Besier, T. F., Fernandez, J. W. & Handsfield, G. G. Soleus muscle weakness in cerebral palsy: Muscle architecture revealed with Diffusion Tensor Imaging. PLOS ONE. 14, e0205944 (2019).","journal-title":"PLOS ONE"},{"key":"63269_CR30","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1148\/radiol.2017171330","volume":"287","author":"A Four\u00e9","year":"2018","unstructured":"Four\u00e9, A. et al. Diffusion properties and 3D architecture of human lower leg muscles assessed with ultra-high-field-strength diffusion-tensor MR imaging and tractography: Reproducibility and sensitivity to sex difference and intramuscular variability. Radiology 287, 592\u2013607 (2018).","journal-title":"Radiology"},{"key":"63269_CR31","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1111\/sms.14283","volume":"33","author":"JJM Suskens","year":"2023","unstructured":"Suskens, J. J. M. et al. Effect of two eccentric hamstring exercises on muscle architectural characteristics assessed with diffusion tensor MRI. Scand. J. Med. Sci. Sports. 33, 393\u2013406 (2023).","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"63269_CR32","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.1002\/jmri.26295","volume":"49","author":"V Malis","year":"2019","unstructured":"Malis, V. et al. Diffusion tensor imaging and diffusion modeling: Application to monitoring changes in the medial gastrocnemius in disuse atrophy induced by unilateral limb suspension. J. Magn. Reson. Imaging. 49, 1655\u20131664 (2019).","journal-title":"J. Magn. Reson. Imaging"},{"key":"63269_CR33","doi-asserted-by":"publisher","first-page":"11836","DOI":"10.1038\/s41598-019-47968-x","volume":"9","author":"C K\u00f6rting","year":"2019","unstructured":"K\u00f6rting, C. et al. In vivo muscle morphology comparison in post-stroke survivors using ultrasonography and diffusion tensor imaging. Sci. Rep. 9, 11836 (2019).","journal-title":"Sci. Rep."},{"key":"63269_CR34","doi-asserted-by":"publisher","first-page":"e0261777","DOI":"10.1371\/journal.pone.0261777","volume":"17","author":"L Secondulfo","year":"2022","unstructured":"Secondulfo, L. et al. A diffusion tensor-based method facilitating volumetric assessment of fiber orientations in skeletal muscle. PLOS ONE. 17, e0261777 (2022).","journal-title":"PLOS ONE"},{"key":"63269_CR35","doi-asserted-by":"publisher","first-page":"1324","DOI":"10.1111\/joa.13750","volume":"241","author":"K Takahashi","year":"2022","unstructured":"Takahashi, K., Shiotani, H., Evangelidis, P. E., Sado, N. & Kawakami, Y. Three-dimensional architecture of human medial gastrocnemius fascicles in vivo: Regional variation and its dependence on muscle size. J. Anat. 241, 1324\u20131335 (2022).","journal-title":"J. Anat."},{"key":"63269_CR36","doi-asserted-by":"publisher","first-page":"e4610","DOI":"10.7717\/peerj.4610","volume":"6","author":"B Bolsterlee","year":"2018","unstructured":"Bolsterlee, B. et al. Three-dimensional architecture of the whole human soleus muscle in vivo. PeerJ 6, e4610 (2018).","journal-title":"PeerJ"},{"key":"63269_CR37","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1002\/mrm.1910340111","volume":"34","author":"P Jezzard","year":"1995","unstructured":"Jezzard, P. & Balaban, R. S. Correction for geometric distortion in echo planar images from B0 field variations. Magn. Reson. Med. 34, 65\u201373 (1995).","journal-title":"Magn. Reson. Med."},{"key":"63269_CR38","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.mri.2020.11.005","volume":"76","author":"CB Hansen","year":"2021","unstructured":"Hansen, C. B. et al. Empirical field mapping for gradient nonlinearity correction of multi-site diffusion weighted MRI. Magn. Reson. Imaging. 76, 69\u201378 (2021).","journal-title":"Magn. Reson. Imaging"},{"key":"63269_CR39","doi-asserted-by":"publisher","first-page":"1951","DOI":"10.1002\/mrm.26070","volume":"76","author":"WM Brink","year":"2016","unstructured":"Brink, W. M., Versluis, M. J., Peeters, J. M., B\u00f6rnert, P. & Webb, A. G. Passive radiofrequency shimming in the thighs at 3 Tesla using high permittivity materials and body coil receive uniformity correction. Magn. Reson. Med. 76, 1951\u20131956 (2016).","journal-title":"Magn. Reson. Med."},{"key":"63269_CR40","doi-asserted-by":"publisher","first-page":"1709","DOI":"10.1007\/s00330-019-06403-5","volume":"30","author":"JR Monte","year":"2020","unstructured":"Monte, J. R. et al. The repeatability of bilateral diffusion tensor imaging (DTI) in the upper leg muscles of healthy adults. Eur. Radiol. 30, 1709\u20131718 (2020).","journal-title":"Eur. Radiol."},{"key":"63269_CR41","doi-asserted-by":"publisher","first-page":"91003","DOI":"10.1115\/1.4024573","volume":"135","author":"A Yaman","year":"2013","unstructured":"Yaman, A., Ozturk, C., Huijing, P. A. & Yucesoy, C. A. Magnetic resonance imaging assessment of mechanical interactions between human lower leg muscles in vivo. J. Biomech. Eng. 135, 91003 (2013).","journal-title":"J. Biomech. Eng."},{"key":"63269_CR42","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.jbiomech.2017.03.028","volume":"57","author":"A Karakuzu","year":"2017","unstructured":"Karakuzu, A., Pamuk, U., Ozturk, C., Acar, B. & Yucesoy, C. A. Magnetic resonance and diffusion tensor imaging analyses indicate heterogeneous strains along human medial gastrocnemius fascicles caused by submaximal plantar-flexion activity. J. Biomech. 57, 69\u201378 (2017).","journal-title":"J. Biomech."},{"key":"63269_CR43","doi-asserted-by":"publisher","first-page":"2784","DOI":"10.1002\/mrm.26921","volume":"79","author":"M Schwartz","year":"2018","unstructured":"Schwartz, M. et al. Spontaneous mechanical and electrical activities of human calf musculature at rest assessed by repetitive single-shot diffusion-weighted MRI and simultaneous surface electromyography. Magn. Reson. Med. 79, 2784\u20132794 (2018).","journal-title":"Magn. Reson. Med."},{"key":"63269_CR44","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/j.neuroimage.2017.12.040","volume":"171","author":"JLR Andersson","year":"2018","unstructured":"Andersson, J. L. R., Graham, M. S., Drobnjak, I., Zhang, H. & Campbell, J. Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data. NeuroImage 171, 277\u2013295 (2018).","journal-title":"NeuroImage"},{"key":"63269_CR45","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1016\/S1053-8119(03)00336-7","volume":"20","author":"JLR Andersson","year":"2003","unstructured":"Andersson, J. L. R., Skare, S. & Ashburner, J. How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. NeuroImage 20, 870\u2013888 (2003).","journal-title":"NeuroImage"},{"key":"63269_CR46","first-page":"373","volume":"19","author":"EM Delfaut","year":"1999","unstructured":"Delfaut, E. M. et al. Fat suppression in MR imaging: techniques and pitfalls. Radiogr Rev. Publ Radiol. Soc. N Am. 19, 373\u2013382 (1999).","journal-title":"Radiogr Rev. Publ Radiol. Soc. N Am."},{"key":"63269_CR47","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1016\/j.neuroimage.2019.06.039","volume":"200","author":"L Cordero-Grande","year":"2019","unstructured":"Cordero-Grande, L., Christiaens, D., Hutter, J., Price, A. N. & Hajnal, J. V. Complex diffusion-weighted image estimation via matrix recovery under general noise models. NeuroImage 200, 391\u2013404 (2019).","journal-title":"NeuroImage"},{"key":"63269_CR48","doi-asserted-by":"publisher","first-page":"1582","DOI":"10.1002\/mrm.26059","volume":"76","author":"J Veraart","year":"2016","unstructured":"Veraart, J., Fieremans, E. & Novikov, D. S. Diffusion MRI noise mapping using random matrix theory. Magn. Reson. Med. 76, 1582\u20131593 (2016).","journal-title":"Magn. Reson. Med."},{"key":"63269_CR49","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1016\/j.neuroimage.2016.08.016","volume":"142","author":"J Veraart","year":"2016","unstructured":"Veraart, J. et al. Denoising of diffusion MRI using random matrix theory. NeuroImage 142, 394\u2013406 (2016).","journal-title":"NeuroImage"},{"key":"63269_CR50","doi-asserted-by":"publisher","first-page":"1210","DOI":"10.1002\/mrm.23097","volume":"67","author":"K Setsompop","year":"2012","unstructured":"Setsompop, K. et al. Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty. Magn. Reson. Med. 67, 1210\u20131224 (2012).","journal-title":"Magn. Reson. Med."},{"key":"63269_CR51","doi-asserted-by":"publisher","first-page":"107425","DOI":"10.1016\/j.jmr.2023.107425","volume":"351","author":"B Qu","year":"2023","unstructured":"Qu, B. et al. A convergence analysis for projected fast iterative soft-thresholding algorithm under radial sampling MRI. J. Magn. Reson. 351, 107425 (2023).","journal-title":"J. Magn. Reson."},{"key":"63269_CR52","doi-asserted-by":"publisher","first-page":"131351","DOI":"10.1016\/j.eswa.2026.131351","volume":"310","author":"B Qu","year":"2026","unstructured":"Qu, B. et al. JSDU-Net: Joint sensitivity-learning driven deep unfolding network for accelerated radial MRI reconstruction. Expert Syst. Appl. 310, 131351 (2026).","journal-title":"Expert Syst. Appl."},{"key":"63269_CR53","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1111\/joa.12062","volume":"223","author":"P Schenk","year":"2013","unstructured":"Schenk, P. et al. Determination of three-dimensional muscle architectures: validation of the DTI-based fiber tractography method by manual digitization. J. Anat. 223, 61\u201368 (2013).","journal-title":"J. Anat."},{"key":"63269_CR54","doi-asserted-by":"publisher","first-page":"1263","DOI":"10.1007\/s10237-024-01837-3","volume":"23","author":"AS Sahrmann","year":"2024","unstructured":"Sahrmann, A. S., Vosse, L., Siebert, T., Handsfield, G. G. & R\u00f6hrle O. 3D ultrasound-based determination of skeletal muscle fascicle orientations. Biomech. Model. Mechanobiol. 23, 1263\u20131276 (2024).","journal-title":"Biomech. Model. Mechanobiol."},{"key":"63269_CR55","doi-asserted-by":"publisher","first-page":"7711","DOI":"10.1038\/s41598-022-11611-z","volume":"12","author":"SG Bin Ghouth","year":"2022","unstructured":"Bin Ghouth, S. G., Williams, S. A., Reid, S. L., Besier, T. F. & Handsfield, G. G. A statistical shape model of soleus muscle morphology in spastic cerebral palsy. Sci. Rep. 12, 7711 (2022).","journal-title":"Sci. Rep."},{"key":"63269_CR56","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.jneumeth.2016.03.001","volume":"264","author":"X Li","year":"2016","unstructured":"Li, X., Morgan, P. S., Ashburner, J., Smith, J. & Rorden, C. The first step for neuroimaging data analysis: DICOM to NIfTI conversion. J. Neurosci. Methods. 264, 47\u201356 (2016).","journal-title":"J. Neurosci. Methods"},{"key":"63269_CR57","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1016\/j.neuroimage.2011.09.015","volume":"62","author":"M Jenkinson","year":"2012","unstructured":"Jenkinson, M., Beckmann, C. F., Behrens, T. E. J., Woolrich, M. W. & Smith, S. M. FSL NeuroImage 62, 782\u2013790 (2012).","journal-title":"FSL NeuroImage"},{"key":"63269_CR58","doi-asserted-by":"publisher","first-page":"116137","DOI":"10.1016\/j.neuroimage.2019.116137","volume":"202","author":"JD Tournier","year":"2019","unstructured":"Tournier, J. D. et al. MRtrix3: A fast, flexible and open software framework for medical image processing and visualisation. NeuroImage 202, 116137 (2019).","journal-title":"NeuroImage"},{"key":"63269_CR59","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/978-1-4614-7657-3_19","volume-title":"Intraoperative Imaging and Image-Guided Therapy","author":"R Kikinis","year":"2014","unstructured":"Kikinis, R., Pieper, S. D. & Vosburgh, K. G. 3D Slicer: A Platform for Subject-Specific Image Analysis, Visualization, and Clinical Support. in Intraoperative Imaging and Image-Guided Therapy (ed Jolesz, F. A.) 277\u2013289 (Springer New York, New York, NY, doi:https:\/\/doi.org\/10.1007\/978-1-4614-7657-3_19. (2014)."},{"key":"63269_CR60","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1002\/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO;2-O","volume":"44","author":"PJ Basser","year":"2000","unstructured":"Basser, P. J., Pajevic, S., Pierpaoli, C., Duda, J. & Aldroubi, A. In vivo fiber tractography using DT-MRI data. Magn. Reson. Med. 44, 625\u2013632 (2000).","journal-title":"Magn. Reson. Med."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-63269-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-63269-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-63269-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T08:03:55Z","timestamp":1784707435000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-63269-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,22]]},"references-count":60,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["63269"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-63269-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,22]]},"assertion":[{"value":"8 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"22938"}}