{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T03:28:36Z","timestamp":1786418916269,"version":"build-2736575974"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T00:00:00Z","timestamp":1786406400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T00:00:00Z","timestamp":1786406400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003385","name":"Georg-August-Universit\u00e4t G\u00f6ttingen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100003385","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Despite their well-known efficacy, forced-air warming during operations has its drawbacks, mainly high energy consumption and risk of hyperthermia. We therefore investigated two warming strategies in a prospective randomized study with the aim of reducing the incidence of hyperthermia without increasing the risk of intraoperative hypothermia. In the standard of care group temperature of the forced-air warmer was reduced to 32\u00a0\u00b0C when core temperature reached 37.3\u00a0\u00b0C. In the modified warming group this reduction was performed when core temperature reached 36.5\u00a0\u00b0C. The difference in the duration of normothermia between standard of care and the modified warming strategy was estimated to be 3.9% (90%-CI: 0.8% to 7.1%) and was within the predefined equivalence bounds of \u00b1\u200920% (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.001). In both treatment groups no intraoperative hyperthermia ocurred. Average energy consumption per hour was significantly higher in the standard-of-care group (0.51 kWh\/h; 95%-CI: 0.47\u20130.56) compared with the modified warming strategy (0.40 kWh\/h; 95%-CI: 0.35\u20130.46;\n                    <jats:italic>p<\/jats:italic>\n                    \u2009=\u20090.002). By strictly limiting the heat supply, intraoperative hyperthermia can be safely prevented during craniotomies. A lower threshold value of 36.5\u00a0\u00b0C allows for a meaningful reduction in energy consumption.\n                  <\/jats:p>","DOI":"10.1038\/s41598-026-66191-z","type":"journal-article","created":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T02:27:11Z","timestamp":1786415231000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Early reduction of forced-air warming temperature can reduce energy consumption during craniotomy: a prospective randomized trial"],"prefix":"10.1038","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4013-8755","authenticated-orcid":false,"given":"Anselm","family":"Br\u00e4uer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julian Manuel","family":"Willrodt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandra-Cristina","family":"Popescu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thadd\u00e4us","family":"Struk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johannes","family":"Wieditz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leif","family":"Saager","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Michels","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,11]]},"reference":[{"issue":"1","key":"66191_CR1","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1002\/aorn.14364","volume":"122","author":"J Speth","year":"2025","unstructured":"Speth, J. Guidelines in Practice: Patient Temperature Management. AORN J. 122 (1), 33\u201341. https:\/\/doi.org\/10.1002\/aorn.14364 (2025).","journal-title":"AORN J."},{"key":"66191_CR2","unstructured":"Australian College of Perioperative Nurses Ltd (ACORN). Standards for perioperative nursing in Australia 15th Edition (Adelaide, 2018)."},{"key":"66191_CR3","unstructured":"NICE: Addendum to Clinical Guideline 65, Inadvertant Perioperative Hypothermia. (2016). https:\/\/www.nice.org.uk\/guidance\/cg65.Accessed 28.3.2026."},{"issue":"10","key":"66191_CR4","first-page":"166","volume":"112","author":"A Torossian","year":"2015","unstructured":"Torossian, A. et al. Preventing inadvertent perioperative hypothermia. Dtsch. Arztebl Int. 112(10), 166\u2013172 (2015).","journal-title":"Dtsch. Arztebl Int."},{"issue":"6","key":"66191_CR5","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1016\/j.jopan.2010.10.006","volume":"25","author":"VD Hooper","year":"2010","unstructured":"Hooper, V. D. et al. ASPAN\u2019s evidence-based clinical practice guideline for the promotion of perioperative normothermia: second edition. J. Perianesth Nurs. 25 (6), 346\u2013365. https:\/\/doi.org\/10.1016\/j.jopan.2010.10.006 (2010).","journal-title":"J. Perianesth Nurs."},{"issue":"1","key":"66191_CR6","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/ana.0000000000000967","volume":"37","author":"SH Kim","year":"2025","unstructured":"Kim, S. H., Choi, S. H., Moon, J., Kim, H. D. & Choi, Y. S. Enhanced Recovery After Surgery for craniotomies: A Systematic review and meta-analysis. J. Neurosurg. Anesthesiol. 37 (1), 11\u201319. https:\/\/doi.org\/10.1097\/ana.0000000000000967 (2025).","journal-title":"J. Neurosurg. Anesthesiol"},{"issue":"3","key":"66191_CR7","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1007\/s00101-019-00727-z","volume":"69","author":"B L\u00f6ser","year":"2020","unstructured":"L\u00f6ser, B. et al. International survey of neurosurgical anesthesia (iSonata): An international survey of current practices in neurosurgical anesthesia. Anaesthesist 69(3), 183\u2013191. https:\/\/doi.org\/10.1007\/s00101-019-00727-z (2020).","journal-title":"Anaesthesist"},{"issue":"1","key":"66191_CR8","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1097\/ALN.0b013e3181c5e28f","volume":"112","author":"BJ Hindman","year":"2010","unstructured":"Hindman, B. J. et al. No association between intraoperative hypothermia or supplemental protective drug and neurologic outcomes in patients undergoing temporary clipping during cerebral aneurysm surgery: findings from the Intraoperative Hypothermia for Aneurysm Surgery Trial. Anesthesiology 112 (1), 86\u2013101. https:\/\/doi.org\/10.1097\/ALN.0b013e3181c5e28f (2010).","journal-title":"Anesthesiology"},{"key":"66191_CR9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrc.2025.155104","volume":"89","author":"D Wasilewski","year":"2025","unstructured":"Wasilewski, D., Truckenmueller, P., Fr\u00fch, A., Vajkoczy, P. & Wolf, S. Evaluating extreme temperature values and patient outcomes in aneurysmal subarachnoid hemorrhage: Post-hoc insights from the Earlydrain trial. J. Crit. Care 89, 155104. https:\/\/doi.org\/10.1016\/j.jcrc.2025.155104 (2025).","journal-title":"J. Crit. Care"},{"issue":"2","key":"66191_CR10","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1056\/NEJMoa040975","volume":"352","author":"MM Todd","year":"2005","unstructured":"Todd, M. M., Hindman, B. J. & Clarke, W. R. Torner JC for the Intraoperative Hypothermia for Aneurysm Surgery Trial (IHAST) Investigators. Mild intraoperative hypothermia during surgery for intracranial aneurysm. N Engl. J. Med. 352 (2), 135\u2013145. https:\/\/doi.org\/10.1056\/NEJMoa040975 (2005).","journal-title":"N Engl. J. Med."},{"issue":"6","key":"66191_CR11","doi-asserted-by":"publisher","first-page":"769","DOI":"10.1097\/ACO.0b013e328331d134","volume":"22","author":"A Br\u00e4uer","year":"2009","unstructured":"Br\u00e4uer, A. & Quintel, M. Forced-air warming: technology, physical background and practical aspects. Curr. Opin. Anaesthesiol. 22 (6), 769\u2013774. https:\/\/doi.org\/10.1097\/ACO.0b013e328331d134 (2009).","journal-title":"Curr. Opin. Anaesthesiol."},{"issue":"6","key":"66191_CR12","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1097\/ALN.0000000000003967","volume":"135","author":"F McGain","year":"2021","unstructured":"McGain, F. et al. Carbon footprint of general, regional, and combined anesthesia for total knee replacements. Anesthesiology 135 (6), 976\u2013999. https:\/\/doi.org\/10.1097\/ALN.0000000000003967 (2021).","journal-title":"Anesthesiology"},{"issue":"2","key":"66191_CR13","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/j.bja.2025.05.018","volume":"135","author":"PMP van Oort","year":"2025","unstructured":"van Oort, P. M. P. et al. Life cycle assessment of reusable versus single-use disposable forced-air warming blankets. Br. J. Anaesth. 135 (2), 513\u2013515. https:\/\/doi.org\/10.1016\/j.bja.2025.05.018 (2025).","journal-title":"Br. J. Anaesth."},{"issue":"6","key":"66191_CR14","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1007\/BF03021491","volume":"55","author":"K Wagner","year":"2008","unstructured":"Wagner, K., Swanson, E., Raymond, C. J. & Smith, C. E. Comparison of two convective warming systems during major abdominal and orthopedic surgery. Can. J. Anaesth. 55(6), 358\u2013363. https:\/\/doi.org\/10.1007\/BF03021491 (2008).","journal-title":"Can. J. Anaesth."},{"issue":"5","key":"66191_CR15","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1097\/EJA.0000000000001322","volume":"38","author":"AJC Mittnacht","year":"2021","unstructured":"Mittnacht, A. J. C., Lin, H. M., Liu, X. & Wax, D. New-onset intra-operative hyperthermia in a large surgical patient population: A retrospective observational study. Eur. J. Anaesthesiol. 38(5), 487\u2013493. https:\/\/doi.org\/10.1097\/EJA.0000000000001322 (2021).","journal-title":"Eur. J. Anaesthesiol."},{"issue":"2","key":"66191_CR16","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1111\/pan.14580","volume":"33","author":"C Miller","year":"2023","unstructured":"Miller, C. et al. Modeling iatrogenic intraoperative hyperthermia from external warming in children: A pooled analysis from two prospective observational studies. Paediatr. Anaesth. 33(2), 114\u2013122. https:\/\/doi.org\/10.1111\/pan.14580 (2023).","journal-title":"Paediatr. Anaesth."},{"issue":"5","key":"66191_CR17","doi-asserted-by":"publisher","first-page":"917","DOI":"10.1007\/s10877-018-0227-z","volume":"33","author":"E Pesonen","year":"2019","unstructured":"Pesonen, E. et al. The focus of temperature monitoring with zero-heat-flux technology (3\u00a0M Bair-Hugger): a clinical study with patients undergoing craniotomy. J. Clin. Monit. Comput. 33 (5), 917\u2013923. https:\/\/doi.org\/10.1007\/s10877-018-0227-z (2019).","journal-title":"J. Clin. Monit. Comput."},{"issue":"5","key":"66191_CR18","doi-asserted-by":"publisher","first-page":"1153","DOI":"10.1007\/s10877-023-00984-9","volume":"37","author":"M Silvasti-Lundell","year":"2023","unstructured":"Silvasti-Lundell, M. et al. Zero-heat-flux thermometry over the carotid artery in assessment of core temperature in craniotomy patients. J. Clin. Monit. Comput. 37 (5), 1153\u20131159. https:\/\/doi.org\/10.1007\/s10877-023-00984-9 (2023).","journal-title":"J. Clin. Monit. Comput."},{"issue":"10337","key":"66191_CR19","doi-asserted-by":"publisher","first-page":"1799","DOI":"10.1016\/S0140-6736(22)00560-8","volume":"399","author":"DI Sessler","year":"2022","unstructured":"Sessler, D. I. et al. Aggressive intraoperative warming versus routine thermal management during non-cardiac surgery (PROTECT): a multicentre, parallel group, superiority trial. Lancet 399 (10337), 1799\u20131808. https:\/\/doi.org\/10.1016\/S0140-6736(22)00560-8 (2022).","journal-title":"Lancet"},{"issue":"9","key":"66191_CR20","doi-asserted-by":"publisher","first-page":"e381","DOI":"10.1016\/S2542-5196(17)30162-6","volume":"1","author":"AJ MacNeill","year":"2017","unstructured":"MacNeill, A. J., Lillywhite, R. & Brown, C. J. The impact of surgery on global climate: A carbon footprinting study of operating theatres in three health systems. Lancet Planet. Health 1(9), e381\u2013e8. https:\/\/doi.org\/10.1016\/S2542-5196(17)30162-6 (2017).","journal-title":"Lancet Planet. Health"},{"issue":"4","key":"66191_CR21","doi-asserted-by":"publisher","first-page":"894","DOI":"10.1097\/ALN.0000000000000319","volume":"121","author":"JD Katz","year":"2014","unstructured":"Katz, J. D. Noise in the operating room. Anesthesiology 121 (4), 894\u2013898. https:\/\/doi.org\/10.1097\/ALN.0000000000000319 (2014). [doi].","journal-title":"Anesthesiology"},{"issue":"2","key":"66191_CR22","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1097\/00008506-199904000-00004","volume":"11","author":"MU Schuhmann","year":"1999","unstructured":"Schuhmann, M. U. et al. Local brain surface temperature compared to temperatures measured at standard extracranial monitoring sites during posterior fossa surgery. J. Neurosurg. Anesthesiol. 11(2), 90\u201395. https:\/\/doi.org\/10.1097\/00008506-199904000-00004 (1999).","journal-title":"J. Neurosurg. Anesthesiol."},{"issue":"1","key":"66191_CR23","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-78753-w","volume":"10","author":"A Br\u00e4uer","year":"2020","unstructured":"Br\u00e4uer, A. et al. Accuracy of zero-heat-flux thermometry and bladder temperature measurement in critically ill patients. Sci. Rep. 10(1), 21746. https:\/\/doi.org\/10.1038\/s41598-020-78753-w (2020).","journal-title":"Sci. Rep."},{"issue":"2","key":"66191_CR24","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1097\/ALN.0b013e3181dfd4f7","volume":"113","author":"HP Nguyen","year":"2010","unstructured":"Nguyen, H. P. et al. Perioperative hypothermia (33 degrees C) does not increase the occurrence of cardiovascular events in patients undergoing cerebral aneurysm surgery: Findings from the Intraoperative Hypothermia for Aneurysm Surgery Trial. Anesthesiology 113(2), 327\u2013342. https:\/\/doi.org\/10.1097\/ALN.0b013e3181dfd4f7 (2010).","journal-title":"Anesthesiology"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-66191-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-66191-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-66191-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T02:44:09Z","timestamp":1786416249000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-66191-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,11]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["66191"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-66191-z","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,11]]},"assertion":[{"value":"29 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A. Br\u00e4uer is a member of the advisory board of TSC Life NL, and received payments from 3\u00a0M Germany, 3\u00a0M Europe, 3\u00a0M Asia Pacific Pte Ltd. Singapore, TSC Life NL, Solventum, Gentherm UK and Moeck and Moeck GmbH Germany for consultancy work. L. Saager is a member of the advisory board of TSC Life NL. All other authors have no conflicts of interest to declare.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"24905"}}