{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T05:06:27Z","timestamp":1788930387494,"version":"build-2803163510"},"reference-count":44,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T00:00:00Z","timestamp":1788912000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T00:00:00Z","timestamp":1788912000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004871","name":"Technische Universit\u00e4t Braunschweig","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004871","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    To investigate the test\u2013retest reliability of skin temperature (T\n                    <jats:sub>sk<\/jats:sub>\n                    ) and the thermal contrast index (TCI) during incremental exercise and examine their responsiveness to cardiovascular, metabolic, and perceptual parameters. Nineteen participants completed two standardized incremental cycling tests with concurrent thermographic, cardiovascular, metabolic, and perceptual measurements. T\n                    <jats:sub>sk<\/jats:sub>\n                    and TCI reliability was evaluated using coefficients of variation, intraclass correlation coefficients, Bland\u2013Altman analysis, and mixed-effects models. T\n                    <jats:sub>sk<\/jats:sub>\n                    showed good to excellent reliability across all regions of interest (ICC\n                    <jats:sub>A,1<\/jats:sub>\n                    : 0.74\u20130.94 [CI: 0.44\u20130.98], SEM\n                    <jats:sub>A,1<\/jats:sub>\n                    : 0.28\u20130.53). TCI reliability varied by region and intensity, ranging from poor to good (ICC\n                    <jats:sub>A,1<\/jats:sub>\n                    : 0.23\u20130.80 [CI: -0.27-0.92], SEM\n                    <jats:sub>A,1<\/jats:sub>\n                    : 0.29\u20130.57), with a tendency toward higher reliability at greater exercise intensities and in the anterior thigh. Confidence intervals were generally wide, warranting cautious interpretation of the reliability estimates. TCI displayed consistent associations with heart rate (\u03b2\u2009=\u20090.46,\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.001), blood lactate (\u03b2\u2009=\u20090.17,\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.001), and energy expenditure (\u03b2\u2009=\u20090.14,\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.001). In contrast, T\n                    <jats:sub>sk<\/jats:sub>\n                    was influenced more by individual traits than by physiological changes. TCI showed a tendency toward good reliability at higher intensities and in performance-relevant muscle regions, but lower reliability at low intensities and in less active areas. TCI also demonstrates meaningful responsiveness to internal load, particularly heart rate, highlighting its potential as a sensitive indicator of physiological load. In contrast, T\n                    <jats:sub>sk<\/jats:sub>\n                    provides stable measurements but primarily reflects individual baseline characteristics rather than acute exercise responses.\n                  <\/jats:p>","DOI":"10.1038\/s41598-026-68741-x","type":"journal-article","created":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T03:55:09Z","timestamp":1788926109000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Reliability and physiological responsiveness of skin temperature and thermal contrast index during incremental exercise: a test\u2013retest analysis"],"prefix":"10.1038","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-4011-7135","authenticated-orcid":false,"given":"Lukas","family":"Masur","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hanna F.","family":"Willenbockel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thekla","family":"Cordes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Billy","family":"Sperlich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"D\u00fcking","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,9]]},"reference":[{"issue":"Suppl 3","key":"68741_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/sms.12581","volume":"25","author":"BK Pedersen","year":"2015","unstructured":"Pedersen, B. K. & Saltin, B. Exercise as medicine - evidence for prescribing exercise as therapy in 26 different chronic diseases. Scand. J. Med. Sci. Sports. 25(Suppl 3), 1\u201372. https:\/\/doi.org\/10.1111\/sms.12581 (2015).","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"68741_CR2","doi-asserted-by":"publisher","first-page":"1873","DOI":"10.1152\/physrev.00038.2020","volume":"101","author":"JD P\u00e9riard","year":"2021","unstructured":"P\u00e9riard, J. D., Eijsvogels, T. M. H. & Daanen, H. A. M. Exercise under heat stress: thermoregulation, hydration, performance implications, and mitigation strategies. Physiol. Rev. 101, 1873\u20131979. https:\/\/doi.org\/10.1152\/physrev.00038.2020 (2021).","journal-title":"Physiol. Rev."},{"key":"68741_CR3","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1249\/MSS.0b013e31802fa199","volume":"39","author":"LE Armstrong","year":"2007","unstructured":"Armstrong, L. E. et al. American College of Sports Medicine position stand. Exertional heat illness during training and competition. Med. Sci. Sports. Exerc. 39, 556\u2013572. https:\/\/doi.org\/10.1249\/MSS.0b013e31802fa199 (2007).","journal-title":"Med. Sci. Sports. Exerc."},{"key":"68741_CR4","doi-asserted-by":"publisher","first-page":"1479608","DOI":"10.3389\/fspor.2024.1479608","volume":"6","author":"L Masur","year":"2024","unstructured":"Masur, L., Brand, F. & D\u00fcking, P. Response of infrared thermography related parameters to (non-)sport specific exercise and relationship with internal load parameters in individual and team sport athletes-a systematic review. Front. sports Act. living. 6, 1479608. https:\/\/doi.org\/10.3389\/fspor.2024.1479608 (2024).","journal-title":"Front. sports Act. living"},{"key":"68741_CR5","doi-asserted-by":"publisher","DOI":"10.1007\/s00421-025-05943-7","author":"L Masur","year":"2025","unstructured":"Masur, L., Willenbockel, H. F., Cordes, T., Sperlich, B. & D\u00fcking, P. Detection of activated perforasome patterns and the correlation with acute internal load parameters during and following incremental cycling. Eur. J. Appl. Physiol. https:\/\/doi.org\/10.1007\/s00421-025-05943-7 (2025).","journal-title":"Eur. J. Appl. Physiol."},{"key":"68741_CR6","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1080\/23328940.2015.1069437","volume":"2","author":"Y Ootsuka","year":"2015","unstructured":"Ootsuka, Y. & Tanaka, M. Control of cutaneous blood flow by central nervous system. Temp. (Austin Tex). 2, 392\u2013405. https:\/\/doi.org\/10.1080\/23328940.2015.1069437 (2015).","journal-title":"Temp. (Austin Tex)"},{"key":"68741_CR7","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1249\/JES.0000000000000085","volume":"44","author":"TP Just","year":"2016","unstructured":"Just, T. P., Cooper, I. R. & DeLorey, D. S. Sympathetic Vasoconstriction in Skeletal Muscle: Adaptations to Exercise Training. Exerc. Sport Sci. Rev. 44, 137\u2013143. https:\/\/doi.org\/10.1249\/JES.0000000000000085 (2016).","journal-title":"Exerc. Sport Sci. Rev."},{"key":"68741_CR8","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1007\/s40279-019-01210-w","volume":"50","author":"B Hillen","year":"2020","unstructured":"Hillen, B., Pfirrmann, D., N\u00e4gele, M. & Simon, P. Infrared Thermography in Exercise Physiology: The Dawning of Exercise Radiomics. Sports Med. (Auckland N Z). 50, 263\u2013282. https:\/\/doi.org\/10.1007\/s40279-019-01210-w (2020).","journal-title":"Sports Med. (Auckland N Z)"},{"key":"68741_CR9","doi-asserted-by":"publisher","first-page":"2237","DOI":"10.1038\/s41598-024-52374-z","volume":"14","author":"P Korman","year":"2024","unstructured":"Korman, P. et al. Response of skin temperature, blood ammonia and lactate during incremental exercise until exhaustion in elite athletes. Sci. Rep. 14, 2237. https:\/\/doi.org\/10.1038\/s41598-024-52374-z (2024).","journal-title":"Sci. Rep."},{"key":"68741_CR10","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1007\/s10439-009-9809-8","volume":"38","author":"A Merla","year":"2010","unstructured":"Merla, A., Mattei, P. A., Di Donato, L. & Romani, G. L. Thermal imaging of cutaneous temperature modifications in runners during graded exercise. Ann. Biomed. Eng. 38, 158\u2013163. https:\/\/doi.org\/10.1007\/s10439-009-9809-8 (2010).","journal-title":"Ann. Biomed. Eng."},{"key":"68741_CR11","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.expthermflusci.2015.10.006","volume":"71","author":"G Tanda","year":"2016","unstructured":"Tanda, G. Skin temperature measurements by infrared thermography during running exercise. Exp. Thermal Fluid Sci. 71, 103\u2013113. https:\/\/doi.org\/10.1016\/j.expthermflusci.2015.10.006 (2016).","journal-title":"Exp. Thermal Fluid Sci."},{"key":"68741_CR12","doi-asserted-by":"publisher","first-page":"33","DOI":"10.2478\/v10038-012-0002-9","volume":"13","author":"M Chudecka","year":"2012","unstructured":"Chudecka, M. & Lubkowska, A. The use of thermal imaging to evaluate body temperature changes of athletes during training and a study on the impact of physiological and morphological factors on skin temperature. Hum. Mov. 13, 33\u201339. https:\/\/doi.org\/10.2478\/v10038-012-0002-9 (2012).","journal-title":"Hum. Mov."},{"key":"68741_CR13","doi-asserted-by":"publisher","first-page":"103605","DOI":"10.1016\/j.jtherbio.2023.103605","volume":"115","author":"B Hillen","year":"2023","unstructured":"Hillen, B. et al. Acute physiological responses to a pyramidal exercise protocol and the associations with skin temperature variation in different body areas. J. Therm. Biol. 115, 103605. https:\/\/doi.org\/10.1016\/j.jtherbio.2023.103605 (2023).","journal-title":"J. Therm. Biol"},{"key":"68741_CR14","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jtherbio.2017.07.006","volume":"69","author":"DG Moreira","year":"2017","unstructured":"Moreira, D. G. et al. Thermographic imaging in sports and exercise medicine: A Delphi study and consensus statement on the measurement of human skin temperature. J. Therm. Biol. 69, 155\u2013162. https:\/\/doi.org\/10.1016\/j.jtherbio.2017.07.006 (2017).","journal-title":"J. Therm. Biol"},{"key":"68741_CR15","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.infrared.2015.02.007","volume":"71","author":"I Fern\u00e1ndez-Cuevas","year":"2015","unstructured":"Fern\u00e1ndez-Cuevas, I. et al. Classification of factors influencing the use of infrared thermography in humans: A review. Infrared Phys. Technol. 71, 28\u201355. https:\/\/doi.org\/10.1016\/j.infrared.2015.02.007 (2015).","journal-title":"Infrared Phys. Technol."},{"key":"68741_CR16","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1016\/j.jtherbio.2018.05.009","volume":"75","author":"M Weigert","year":"2018","unstructured":"Weigert, M., Nitzsche, N., Kunert, F., L\u00f6sch, C. & Schulz, H. The influence of body composition on exercise-associated skin temperature changes after resistance training. J. Therm. Biol. 75, 112\u2013119. https:\/\/doi.org\/10.1016\/j.jtherbio.2018.05.009 (2018).","journal-title":"J. Therm. Biol"},{"key":"68741_CR17","doi-asserted-by":"publisher","first-page":"2539","DOI":"10.1007\/s00421-011-2230-7","volume":"112","author":"DJ Macfarlane","year":"2012","unstructured":"Macfarlane, D. J. & Wong, P. Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system. Eur. J. Appl. Physiol. 112, 2539\u20132547. https:\/\/doi.org\/10.1007\/s00421-011-2230-7 (2012).","journal-title":"Eur. J. Appl. Physiol."},{"key":"68741_CR18","doi-asserted-by":"publisher","first-page":"e14490","DOI":"10.1111\/sms.14490","volume":"34","author":"B van Hooren","year":"2024","unstructured":"van Hooren, B., Souren, T. & Bongers, B. C. Accuracy of respiratory gas variables, substrate, and energy use from 15 CPET systems during simulated and human exercise. Scand. J. Med. Sci. Sports. 34, e14490. https:\/\/doi.org\/10.1111\/sms.14490 (2024).","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"68741_CR19","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1007\/s00421-012-2421-x","volume":"113","author":"J Scherr","year":"2013","unstructured":"Scherr, J. et al. Associations between Borg\u2019s rating of perceived exertion and physiological measures of exercise intensity. Eur. J. Appl. Physiol. 113, 147\u2013155. https:\/\/doi.org\/10.1007\/s00421-012-2421-x (2013).","journal-title":"Eur. J. Appl. Physiol."},{"key":"68741_CR20","doi-asserted-by":"crossref","unstructured":"Rocha, D. et al. Identification and Classification of Human Body Parts for Contactless Screening Systems: An Edge-AI Approach. In Science and Technologies for Smart Cities (ed Paiva, S.) 92\u2013103 (Springer International Publishing, 2022).","DOI":"10.1007\/978-3-031-06371-8_7"},{"key":"68741_CR21","doi-asserted-by":"publisher","first-page":"103751","DOI":"10.1016\/j.jtherbio.2023.103751","volume":"118","author":"B Trovato","year":"2023","unstructured":"Trovato, B. et al. Thermal profile classification of the back of sportive and sedentary healthy individuals. J. Therm. Biol. 118, 103751. https:\/\/doi.org\/10.1016\/j.jtherbio.2023.103751 (2023).","journal-title":"J. Therm. Biol"},{"key":"68741_CR22","doi-asserted-by":"publisher","first-page":"1393804","DOI":"10.3389\/fphys.2024.1393804","volume":"15","author":"B Trovato","year":"2024","unstructured":"Trovato, B., Sortino, M., Petrigna, L., Roggio, F. & Musumeci, G. The influence of static and dynamic warm-up on knee temperature: infrared thermography insights before and after a change of direction exercise. Front. Physiol. 15, 1393804. https:\/\/doi.org\/10.3389\/fphys.2024.1393804 (2024).","journal-title":"Front. Physiol."},{"key":"68741_CR23","doi-asserted-by":"publisher","first-page":"1419","DOI":"10.1519\/JSC.0000000000004453","volume":"37","author":"M Krzysztofik","year":"2023","unstructured":"Krzysztofik, M. et al. Acute Effects of Varied Back Squat Activation Protocols on Muscle-Tendon Stiffness and Jumping Performance. J. strength. conditioning Res. 37, 1419\u20131427. https:\/\/doi.org\/10.1519\/JSC.0000000000004453 (2023).","journal-title":"J. strength. conditioning Res."},{"key":"68741_CR24","doi-asserted-by":"publisher","first-page":"103923","DOI":"10.1016\/j.jtherbio.2024.103923","volume":"123","author":"W da Silva","year":"2024","unstructured":"da Silva, W. et al. Effect of different Volumes of exercise on skin temperature responses over the following 24 hours. J. Therm. Biol. 123, 103923. https:\/\/doi.org\/10.1016\/j.jtherbio.2024.103923 (2024).","journal-title":"J. Therm. Biol"},{"key":"68741_CR25","doi-asserted-by":"publisher","first-page":"103345","DOI":"10.1016\/j.jtherbio.2022.103345","volume":"110","author":"W da Silva","year":"2022","unstructured":"da Silva, W. et al. Reproducibility of skin temperature analyses by novice and experienced evaluators using infrared thermography. J. Therm. Biol. 110, 103345. https:\/\/doi.org\/10.1016\/j.jtherbio.2022.103345 (2022).","journal-title":"J. Therm. Biol"},{"key":"68741_CR26","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.jtherbio.2014.08.010","volume":"45","author":"CA James","year":"2014","unstructured":"James, C. A., Richardson, A. J., Watt, P. W. & Maxwell, N. S. Reliability and validity of skin temperature measurement by telemetry thermistors and a thermal camera during exercise in the heat. J. Therm. Biol. 45, 141\u2013149. https:\/\/doi.org\/10.1016\/j.jtherbio.2014.08.010 (2014).","journal-title":"J. Therm. Biol"},{"key":"68741_CR27","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1037\/1082-989X.1.1.30","volume":"1","author":"KO McGraw","year":"1996","unstructured":"McGraw, K. O. & Wong, S. P. Forming inferences about some intraclass correlation coefficients. Psychol. Methods. 1, 30\u201346. https:\/\/doi.org\/10.1037\/1082-989X.1.1.30 (1996).","journal-title":"Psychol. Methods"},{"key":"68741_CR28","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo, T. K. & Li, M. Y. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. J. Chiropr. Med. 15, 155\u2013163. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012 (2016).","journal-title":"J. Chiropr. Med."},{"key":"68741_CR29","doi-asserted-by":"publisher","first-page":"95","DOI":"10.3389\/fnhum.2018.00095","volume":"12","author":"L Furlan","year":"2018","unstructured":"Furlan, L. & Sterr, A. The Applicability of Standard Error of Measurement and Minimal Detectable Change to Motor Learning Research-A Behavioral Study. Front. Hum. Neurosci. 12, 95. https:\/\/doi.org\/10.3389\/fnhum.2018.00095 (2018).","journal-title":"Front. Hum. Neurosci."},{"key":"68741_CR30","doi-asserted-by":"publisher","first-page":"297","DOI":"10.2165\/00007256-200838040-00003","volume":"38","author":"K Currell","year":"2008","unstructured":"Currell, K. & Jeukendrup, A. E. Validity, reliability and sensitivity of measures of sporting performance. Sports Med. (Auckland N Z). 38, 297\u2013316. https:\/\/doi.org\/10.2165\/00007256-200838040-00003 (2008).","journal-title":"Sports Med. (Auckland N Z)"},{"key":"68741_CR31","doi-asserted-by":"publisher","unstructured":"Brown, V. A. An Introduction to Linear Mixed-Effects Modeling in R. Adv. Methods Practices Psychol. Sci. 4 https:\/\/doi.org\/10.1177\/2515245920960351 (2021).","DOI":"10.1177\/2515245920960351"},{"key":"68741_CR32","doi-asserted-by":"crossref","unstructured":"Zuur, A. F., Ieno, E. N., Walker, N., Saveliev, A. A. & Smith, G. M. Mixed effects models and extensions in ecology with R (Springer New York, 2009).","DOI":"10.1007\/978-0-387-87458-6"},{"key":"68741_CR33","unstructured":"Fox, J. & Weisberg, S. An R companion to applied regression (SAGE, 2019)."},{"key":"68741_CR34","unstructured":"Sawka, M. N. & Wenger, C. B. Physiologic Responses to Acute Exercise Heat Stress. (Benchmark Press, 1998)."},{"key":"68741_CR35","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1249\/00005768-199203000-00005","volume":"24","author":"WL Kenney","year":"1992","unstructured":"Kenney, W. L. & Johnson, J. M. Control of skin blood flow during exercise. Med. Sci. Sports. Exerc. 24, 303\u2013312 (1992).","journal-title":"Med. Sci. Sports. Exerc."},{"key":"68741_CR36","doi-asserted-by":"publisher","first-page":"1529","DOI":"10.1097\/PRS.0b013e3181b98a6c","volume":"124","author":"M Saint-Cyr","year":"2009","unstructured":"Saint-Cyr, M., Wong, C., Schaverien, M., Mojallal, A. & Rohrich, R. J. The perforasome theory: vascular anatomy and clinical implications. Plast. Reconstr. Surg. 124, 1529\u20131544. https:\/\/doi.org\/10.1097\/PRS.0b013e3181b98a6c (2009).","journal-title":"Plast. Reconstr. Surg."},{"key":"68741_CR37","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1111\/sms.13570","volume":"30","author":"M Kordi","year":"2020","unstructured":"Kordi, M. et al. Mechanical and morphological determinants of peak power output in elite cyclists. Scand. J. Med. Sci. Sports. 30, 227\u2013237. https:\/\/doi.org\/10.1111\/sms.13570 (2020).","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"68741_CR38","doi-asserted-by":"publisher","first-page":"1146","DOI":"10.1111\/sms.14347","volume":"33","author":"C Zinner","year":"2023","unstructured":"Zinner, C. et al. The magnitude and time-course of physiological responses to 9 weeks of incremental ramp testing. Scand. J. Med. Sci. Sports. 33, 1146\u20131156. https:\/\/doi.org\/10.1111\/sms.14347 (2023).","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"68741_CR39","doi-asserted-by":"publisher","first-page":"3729","DOI":"10.1007\/s00421-012-2354-4","volume":"112","author":"DJ Plews","year":"2012","unstructured":"Plews, D. J., Laursen, P. B., Kilding, A. E. & Buchheit, M. Heart rate variability in elite triathletes, is variation in variability the key to effective training? A case comparison. Eur. J. Appl. Physiol. 112, 3729\u20133741. https:\/\/doi.org\/10.1007\/s00421-012-2354-4 (2012).","journal-title":"Eur. J. Appl. Physiol."},{"key":"68741_CR40","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1123\/ijspp.8.6.688","volume":"8","author":"DJ Plews","year":"2013","unstructured":"Plews, D. J., Laursen, P. B., Kilding, A. E. & Buchheit, M. Evaluating training adaptation with heart-rate measures: a methodological comparison. Int. J. Sports Physiol. Perform. 8, 688\u2013691. https:\/\/doi.org\/10.1123\/ijspp.8.6.688 (2013).","journal-title":"Int. J. Sports Physiol. Perform."},{"key":"68741_CR41","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1123\/ijspp.2013-0455","volume":"9","author":"DJ Plews","year":"2014","unstructured":"Plews, D. J. et al. Monitoring training with heart rate-variability: how much compliance is needed for valid assessment? Int. J. Sports Physiol. Perform. 9, 783\u2013790 (2014).","journal-title":"Int. J. Sports Physiol. Perform."},{"key":"68741_CR42","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1186\/s40064-016-1843-z","volume":"5","author":"JI Priego Quesada","year":"2016","unstructured":"Priego Quesada, J. I., Carpes, F. P., Palmer, S. & P\u00e9rez-Soriano, R. Cibri\u00e1n Ortiz de Anda, R. M. Effect of saddle height on skin temperature measured in different days of cycling. SpringerPlus 5, 205. https:\/\/doi.org\/10.1186\/s40064-016-1843-z (2016).","journal-title":"SpringerPlus"},{"key":"68741_CR43","doi-asserted-by":"publisher","first-page":"1","DOI":"10.15226\/2374-6904\/2\/3\/00128","volume":"2","author":"S Duc","year":"2015","unstructured":"Duc, S. Efficiency and Thermography in Cycling during a Graded Exercise Test. JESO 2, 1\u20138. https:\/\/doi.org\/10.15226\/2374-6904\/2\/3\/00128 (2015).","journal-title":"JESO"},{"key":"68741_CR44","doi-asserted-by":"publisher","unstructured":"Weber, V. et al. Deep learning-based infrared thermography reveals reproducible uniform and individual thermoregulatory responses during running. Sci. Rep. 16 https:\/\/doi.org\/10.1038\/s41598-026-44102-6 (2026).","DOI":"10.1038\/s41598-026-44102-6"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-68741-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-68741-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-68741-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T04:09:07Z","timestamp":1788926947000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-68741-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,9]]},"references-count":44,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["68741"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-68741-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,9]]},"assertion":[{"value":"14 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"28200"}}