{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T12:07:29Z","timestamp":1788955649242,"version":"build-2803163510"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T00:00:00Z","timestamp":1788912000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T00:00:00Z","timestamp":1788912000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"National Institute of Standards"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The dynamic evaporation and mixing technique standardized in EN 1839 (method T), originally developed to determine the flammability limits of chemical vapors, was applied to prepare isoflurane-in-air calibration gas mixtures, with air serving as the carrier gas. Isoflurane concentrations spanning 0 to 8 vol% were generated on demand by independently controlling the liquid isoflurane and air flow rates. Verification using an anesthetic gas monitor demonstrated excellent agreement between predicted and measured concentrations. A comprehensive validation study was conducted in accordance with EURACHEM guidelines, encompassing linearity, limit of detection (LOD), limit of quantification (LOQ), precision, robustness, and measurement uncertainty. The method yielded a correlation coefficient of r\u00b2 = 0.9998 over the full clinical range, an LOD of 0.08 vol%, and an LOQ of 0.27 vol%. All concentrations between 0.70 and 8 vol% complied with EN 1839 uncertainty requirements, confirming the suitability of this approach for routine calibration of isoflurane gas monitors.<\/jats:p>","DOI":"10.1038\/s41598-026-69018-z","type":"journal-article","created":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T11:12:59Z","timestamp":1788952379000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Validation of a dynamic evaporation technique for generating isoflurane\/air gas mixtures standards to calibrate anesthetic gas monitors"],"prefix":"10.1038","volume":"16","author":[{"given":"Aksam","family":"Abdelkhalik","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ghada","family":"Makhlouf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Randa N.","family":"Yamani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,9]]},"reference":[{"key":"69018_CR1","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1007\/BF01651462","volume":"10","author":"DR Westenskow","year":"1994","unstructured":"Westenskow, D. R., Wallroth, C. F., Hattendorff, H.-D., Best-Timmann, R. & Gippert, K.-L. Standard gases used to calibrate anesthetic vapour analyzers: are they stable? J. Clin. Monit. 10, 21\u201325 (1994).","journal-title":"J. Clin. Monit."},{"key":"69018_CR2","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1007\/BF01618679","volume":"9","author":"B Walder","year":"1993","unstructured":"Walder, B., Lauber, R. & Zbinden, A. M. Accuracy and cross-sensitivity of 10 different anesthetic gas monitors. J. Clin. Monit. 9, 364\u2013373 (1993).","journal-title":"J. Clin. Monit."},{"key":"69018_CR3","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1007\/BF01617909","volume":"8","author":"PL Christensen","year":"1992","unstructured":"Christensen, P. L., Nielsen, J. & Kann, T. Methods to produce calibration mixtures for anesthetic gas monitors and how to perform volumetric calculations on anesthetic gases. J. Clin. Monit. 8, 279\u2013284 (1992).","journal-title":"J. Clin. Monit."},{"key":"69018_CR4","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1007\/BF01618123","volume":"7","author":"DR Westenskow","year":"1991","unstructured":"Westenskow, D. R. & Silva, F. H. Laboratory evaluation of the ICOR piezoelectric anesthetic agent analyzer. J. Clin. Monit. 7, 189\u2013194 (1991).","journal-title":"J. Clin. Monit."},{"key":"69018_CR5","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1007\/BF01617718","volume":"11","author":"CF Wallroth","year":"1995","unstructured":"Wallroth, C. F. et al. Refractive indices for volatile anesthetic gases: equipment and method for calibrating vaporizers and monitors. J. Clin. Monit. 11, 168\u2013174 (1995).","journal-title":"J. Clin. Monit."},{"key":"69018_CR6","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1007\/BF02851169","volume":"2","author":"JW Severinghaus","year":"1986","unstructured":"Severinghaus, J. W. & Young, W. G. A gas mixer for computer calibration of an anesthetic mass spectrometer. J. Clin. Monit. 2, 223\u2013229 (1986).","journal-title":"J. Clin. Monit."},{"key":"69018_CR7","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1007\/BF01616920","volume":"9","author":"J Nielsen","year":"1993","unstructured":"Nielsen, J., Kann, T. & M\u00f8ller, J. T. Evaluation of three transportable multigas anesthetic monitors. J. Clin. Monit. 9, 91\u201398 (1993).","journal-title":"J. Clin. Monit."},{"key":"69018_CR8","doi-asserted-by":"publisher","first-page":"1069","DOI":"10.1007\/s10877-020-00554-3","volume":"35","author":"A Abdelkhalik","year":"2021","unstructured":"Abdelkhalik, A., Makhlouf, G. & Hassan, M. A. A new implementation of EN 1839 method T mixture preparation to prepare calibration gas mixtures for anesthetic gas monitors. J. Clin. Monit. Comput. 35, 1069\u20131076 (2021).","journal-title":"J. Clin. Monit. Comput."},{"key":"69018_CR9","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1016\/S0021-9673(01)88837-3","volume":"540","author":"P Konieczka","year":"1991","unstructured":"Konieczka, P., Namie\u015bnik, J. & Biernat, J. F. Generation of standard gaseous mixtures by thermal decomposition of surface compounds. J. Chromatogr. A 540, 449\u2013455 (1991).","journal-title":"J. Chromatogr. A"},{"key":"69018_CR10","doi-asserted-by":"crossref","unstructured":"Li, Y., Taffner, T., Bischoff, M. & Niemeyer, B. Test gas generation from pure liquids: an application-oriented overview of methods in a nutshell. Int. J. Chem. Eng. 2012, 417029 (2012).","DOI":"10.1155\/2012\/417029"},{"key":"69018_CR11","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/S0021-9673(01)87581-6","volume":"300","author":"J Namie\u015bnik","year":"1984","unstructured":"Namie\u015bnik, J. Generation of standard gaseous mixtures. J. Chromatogr. A 300, 79\u2013108 (1984).","journal-title":"J. Chromatogr. A"},{"key":"69018_CR12","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.chroma.2003.10.079","volume":"1025","author":"JA Koziel","year":"2004","unstructured":"Koziel, J. A., Martos, P. A. & Pawliszyn, J. System for the generation of standard gas mixtures of volatile and semivolatile organic compounds. J. Chromatogr. A 1025, 3\u20139 (2004).","journal-title":"J. Chromatogr. A"},{"key":"69018_CR13","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1039\/an9810600817","volume":"106","author":"RS Barratt","year":"1981","unstructured":"Barratt, R. S. The preparation of standard gas mixtures: a review. Analyst 106, 817\u2013849 (1981).","journal-title":"Analyst"},{"key":"69018_CR14","volume-title":"EN 1839. Determination of the explosion limits and the limiting oxygen concentration (LOC) for flammable gases and vapours","author":"European Standard","year":"2017","unstructured":"European Standard EN 1839. Determination of the explosion limits and the limiting oxygen concentration (LOC) for flammable gases and vapours. (CEN, Brussels, 2017)."},{"key":"69018_CR15","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1016\/j.jlp.2016.04.001","volume":"43","author":"A Abdelkhalik","year":"2016","unstructured":"Abdelkhalik, A., et al. Explosion regions of propane, isopropanol, acetone, and methyl acetate\/inert gas\/air mixtures. J. Loss Prev. Process Ind. 43, 669\u2013675 (2016).","journal-title":"J. Loss Prev. Process Ind."},{"key":"69018_CR16","doi-asserted-by":"publisher","first-page":"103958","DOI":"10.1016\/j.jlp.2019.103958","volume":"62","author":"A Abdelkhalik","year":"2019","unstructured":"Abdelkhalik, A., Askar, E., Markus, D., Brandes, E. & Stolz, T. Explosion regions of acetone and alcohol\/inert gas\/air mixtures at high temperatures and atmospheric pressure. J. Loss Prev. Process Ind. 62, 103958 (2019).","journal-title":"J. Loss Prev. Process Ind."},{"key":"69018_CR17","doi-asserted-by":"publisher","first-page":"104496","DOI":"10.1016\/j.jlp.2021.104496","volume":"71","author":"A Abdelkhalik","year":"2021","unstructured":"Abdelkhalik, A., Askar, E., Markus, D., Stolz, T., Brandes, E. & Zakel, S. Explosion regions of 1,3-dioxolane\/nitrous oxide and 1,3-dioxolane\/air with different inert gases. J. Loss Prev. Process Ind. 71, 104496 (2021).","journal-title":"J. Loss Prev. Process Ind."},{"key":"69018_CR18","unstructured":"Isoflurane Material Safety Data Sheet. (Piramal Critical Care, Manufacturer\u2019s product documentation, Accessed April 2026)."},{"key":"69018_CR19","unstructured":"Magnusson, B. & \u00d6rnemark, U. (Eds.). The Fitness for Purpose of Analytical Methods: A Laboratory Guide to Method Validation and Related Topics. (2nd ed., EURACHEM Guide, 2014)."},{"key":"69018_CR20","unstructured":"RIKEN KEIKI. Optical Interferometric Gas Monitor \u2013 Measurement Principle. (Technical documentation, Accessed April 2026)."},{"key":"69018_CR21","unstructured":"Wikipedia. Bartlett\u2019s test. Available at: https:\/\/en.wikipedia.org\/wiki\/Bartlett%27s_test. (Accessed June 2026)."},{"key":"69018_CR22","unstructured":"NIST\/SEMATECH. Bartlett\u2019s Test. e-Handbook of Statistical Methods. Available at: https:\/\/www.itl.nist.gov\/div898\/handbook\/. (2012)."},{"key":"69018_CR23","unstructured":"EURACHEM: Determination of Trueness\/Bias \u2013 Workshop Proceedings. (EURACHEM, 2016). https:\/\/www.eurachem.org\/images\/stories\/workshops\/2016_05_MV\/pdf\/wg\/day2-wg1_determination_of_trueness___bias.pdf"},{"key":"69018_CR24","volume-title":"Guidance for the Validation of Analytical Methodology and Calibration of Equipment used for Testing of Illicit Drugs","author":"United Nations Office on Drugs and Crime (UNODC)","year":"2009","unstructured":"United Nations Office on Drugs and Crime (UNODC): Guidance for the Validation of Analytical Methodology and Calibration of Equipment used for Testing of Illicit Drugs. (United Nations, New York, 2009)."},{"key":"69018_CR25","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1186\/s12871-019-0822-7","volume":"19","author":"J Herzog-Niescery","year":"2019","unstructured":"Herzog-Niescery, J. et al. Photoacoustic gas monitoring for anesthetic gas pollution measurements and its cross-sensitivity to alcoholic disinfectants. BMC Anesthesiol. 19, 148 (2019).","journal-title":"BMC Anesthesiol."},{"key":"69018_CR26","unstructured":"Gasmet\u2122 FTIR Application Note: Anesthetic Gases \u2013 Point Monitoring. (Gasmet Technologies, 2013, Accessed July 2026). https:\/\/yaga.no\/wp-content\/uploads\/2021\/06\/anesthetic_gases_point_monitoring_002.0.pdf"},{"key":"69018_CR27","unstructured":"Ellison, S. L. R., Roesslein, M. & Williams, A. (Eds.). Quantifying Uncertainty in Analytical Measurement. (3rd ed., EURACHEM\/CITAC Guide CG 4, QUAM, 2012), p.1."},{"key":"69018_CR28","unstructured":"NIST\/SEMATECH. Homoscedasticity Plot. e-Handbook of Statistical Methods. Available at: https:\/\/www.itl.nist.gov\/div898\/handbook\/. (2012)."},{"key":"69018_CR29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/mas.20100","volume":"26","author":"I Lavagnini","year":"2007","unstructured":"Lavagnini, I. & Magno, F. A statistical overview on univariate calibration, inverse prediction, and detection limits in analytical chemistry. Mass Spectrom. Rev. 26, 1\u201351 (2007).","journal-title":"Mass Spectrom. Rev."},{"key":"69018_CR30","unstructured":"ISO\/IEC Guide 98\u2009\u2013\u20093:2008. Uncertainty of measurement \u2014 Part 3: Guide to the expression of uncertainty in measurement (GUM:1995). (ISO\/IEC, Geneva, 2008)."},{"key":"69018_CR31","first-page":"275","volume":"446","author":"AG Gonz\u00e1lez","year":"2001","unstructured":"Gonz\u00e1lez, A. G. & Herrador, M. A. Measurement uncertainty in analytical methods in which trueness is assessed from recovery assays. Anal. Chim. Acta 446, 275\u2013285 (2001).","journal-title":"Anal. Chim. Acta"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-69018-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-69018-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-69018-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T11:30:59Z","timestamp":1788953459000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-69018-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,9]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["69018"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-69018-z","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,9]]},"assertion":[{"value":"13 July 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"28220"}}