{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T16:19:28Z","timestamp":1788538768907,"version":"build-2803163510"},"reference-count":68,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T00:00:00Z","timestamp":1788480000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T00:00:00Z","timestamp":1788480000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Leibniz-Institut f\u00fcr Photonische Technologien e.V."}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>With its high molecular complexity, human breath lends itself as an information-rich sample for non-invasive biomedical diagnostics. Among emerging multi-variate analytical techniques for human breath, laser-based optical spectroscopy constitutes a particularly promising novel combination of short measurement times and high concentration dynamic range for molecular detection. Here, we present an automated system designed for continuous collection of exhaled breath directly from a respirator, and subsequent spectroscopic analysis. By obviating any additional intermediate sample storage or transport, our method minimizes setup complexity and sample contamination, while avoiding interference with the operation of the respirator. In this proof-of-principle study, we present automated and quantitative monitoring of three substances introduced in an artificial test lung ventilated by the respirator. Employing a standard Fourier-transform infrared spectrometer for molecular quantification, individual measurements were performed every 7\u00a0min over 24\u00a0h. The stability and analytical capability of the breath sampling system presented here, along with improvements in terms of spectral resolution and detection dynamic range obtainable through state-of-the-art laser-based spectroscopy promise fast and quantitative monitoring of the human breath volatilome. Coupled to state-of-the-art spectroscopy this may pave the way to monitor metabolites in real time in critically ill patients over the entire physiologically relevant molecular concentration range.<\/jats:p>","DOI":"10.1038\/s41598-026-69327-3","type":"journal-article","created":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T15:35:34Z","timestamp":1788536134000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Respirator-integrated continuous gas sampling for broadband optical spectroscopy"],"prefix":"10.1038","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3699-9453","authenticated-orcid":false,"given":"Aleksandra","family":"Borek-Dorosz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8877-151X","authenticated-orcid":false,"given":"Jan","family":"Ornik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-1302-4935","authenticated-orcid":false,"given":"Marco","family":"Personeni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Haering","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6243-802X","authenticated-orcid":false,"given":"Maximilian","family":"H\u00f6gner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-3989-0215","authenticated-orcid":false,"given":"Felix","family":"Paries","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-7445-5556","authenticated-orcid":false,"given":"Margit","family":"Leitner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jens-Uwe","family":"Wei\u00df","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0251-7711","authenticated-orcid":false,"given":"Ignacio","family":"Rubio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1521-3514","authenticated-orcid":false,"given":"Michael","family":"Bauer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8422-667X","authenticated-orcid":false,"given":"Ioachim","family":"Pupeza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,4]]},"reference":[{"key":"69327_CR1","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1038\/s42003-024-05943-x","volume":"7","author":"M Malik","year":"2024","unstructured":"Malik, M., Demetrowitsch, T., Schwarz, K. & Kunze, T. New perspectives on \u2018Breathomics\u2019: metabolomic profiling of non-volatile organic compounds in exhaled breath using DI-FT-ICR-MS. Commun. Biol. 7, 258 (2024). https:\/\/doi.org\/10.1038\/s42003-024-05943-x","journal-title":"Commun. Biol."},{"key":"69327_CR2","doi-asserted-by":"publisher","first-page":"311","DOI":"10.3390\/chemosensors13080311","volume":"13","author":"VN Quaranta","year":"2025","unstructured":"Quaranta, V. N. et al. Breathprint-based endotyping of COPD and bronchiectasis COPD overlap using electronic nose technology: a prospective observational study. Chemosensors 13, 311 (2025). https:\/\/doi.org\/10.3390\/chemosensors13080311","journal-title":"Chemosensors"},{"key":"69327_CR3","doi-asserted-by":"publisher","unstructured":"Incalzi, R. A., De Vincentis, A., Pedone, C. Breathprinting-Based Diagnosis Selected Case Study: Nonneoplastic Chronic Diseases. in Breath Analysis (eds. Pennazza, G. & Santonico, M. B. T.-B. A.) 95\u2013120 (Academic Press, 2019). https:\/\/doi.org\/10.1016\/B978-0-12-814562-3.00006-0","DOI":"10.1016\/B978-0-12-814562-3.00006-0"},{"key":"69327_CR4","doi-asserted-by":"publisher","first-page":"37562","DOI":"10.1149\/1945-7111\/ab67a6","volume":"167","author":"S Das","year":"2020","unstructured":"Das, S. & Pal, M. Review\u2014Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review. J. Electrochem. Soc. 167, 37562 (2020). https:\/\/doi.org\/10.1149\/1945-7111\/ab67a6","journal-title":"J. Electrochem. Soc."},{"key":"69327_CR5","doi-asserted-by":"publisher","first-page":"2","DOI":"10.34133\/bmef.0002","volume":"4","author":"M Oxner","year":"2026","unstructured":"Oxner, M. et al. The Versatility and Diagnostic Potential of VOC Profiling for Noninfectious Diseases. BME Front. 4, 2 (2026). https:\/\/doi.org\/10.34133\/bmef.0002","journal-title":"BME Front."},{"key":"69327_CR6","doi-asserted-by":"publisher","first-page":"36008","DOI":"10.1088\/1752-7163\/add617","volume":"19","author":"IL Gade","year":"2025","unstructured":"Gade, I. L. et al. Exhaled breath protein composition in patients hospitalised during the first wave of COVID-19. J. Breath. Res. 19, 36008 (2025). https:\/\/doi.org\/10.1088\/1752-7163\/add617","journal-title":"J. Breath. Res."},{"key":"69327_CR7","doi-asserted-by":"publisher","first-page":"117541","DOI":"10.1016\/j.trac.2024.117541","volume":"171","author":"H Huang","year":"2024","unstructured":"Huang, H. et al. Exhaled breath analysis of non-volatile drugs: Towards clinical applications. TrAC Trends Anal. Chem. 171, 117541 (2024). https:\/\/doi.org\/10.1016\/j.trac.2024.117541","journal-title":"TrAC Trends Anal. Chem."},{"key":"69327_CR8","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1007\/s00340-006-2280-4","volume":"85","author":"TH Risby","year":"2006","unstructured":"Risby, T. H. & Solga, S. F. Current status of clinical breath analysis. Appl. Phys. B. 85, 421\u2013426 (2006). https:\/\/doi.org\/10.1007\/s00340-006-2280-4","journal-title":"Appl. Phys. B"},{"key":"69327_CR9","doi-asserted-by":"publisher","first-page":"342468","DOI":"10.1016\/j.aca.2024.342468","volume":"1301","author":"E Schulz","year":"2024","unstructured":"Schulz, E., Woollam, M., Vashistha, S. & Agarwal, M. Quantifying exhaled acetone and isoprene through solid phase microextraction and gas chromatography-mass spectrometry. Anal. Chim. Acta. 1301, 342468 (2024). https:\/\/doi.org\/10.1016\/j.aca.2024.342468","journal-title":"Anal. Chim. Acta"},{"key":"69327_CR10","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1007\/s40846-016-0164-6","volume":"36","author":"S Das","year":"2016","unstructured":"Das, S., Pal, S. & Mitra, M. Significance of exhaled breath test in clinical diagnosis: a special focus on the detection of diabetes mellitus. J. Med. Biol. Eng. 36, 605\u2013624 (2016). https:\/\/doi.org\/10.1007\/s40846-016-0164-6","journal-title":"J. Med. Biol. Eng."},{"key":"69327_CR11","doi-asserted-by":"publisher","first-page":"2235","DOI":"10.3390\/ijms18112235","volume":"18","author":"X Chen","year":"2017","unstructured":"Chen, X. et al. Association of smoking with metabolic volatile organic compounds in exhaled breath. Int. J. Mol. Sci. 18, 2235 (2017). https:\/\/doi.org\/10.3390\/ijms18112235","journal-title":"Int. J. Mol. Sci."},{"key":"69327_CR12","doi-asserted-by":"publisher","first-page":"100623","DOI":"10.1016\/j.bj.2023.100623","volume":"46","author":"PC Moura","year":"2023","unstructured":"Moura, P. C., Raposo, M. & Vassilenko, V. Breath volatile organic compounds (VOCs) as biomarkers for the diagnosis of pathological conditions: A review. Biomed. J. 46, 100623 (2023). https:\/\/doi.org\/10.1016\/j.bj.2023.100623","journal-title":"Biomed. J."},{"key":"69327_CR13","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1016\/j.cpt.2024.12.004","volume":"3","author":"Y Gao","year":"2025","unstructured":"Gao, Y. et al. Volatile organic compounds in exhaled breath: Applications in cancer diagnosis and predicting treatment efficacy. Cancer Pathog Ther. 3, 411\u2013419 (2025). https:\/\/doi.org\/10.1016\/j.cpt.2024.12.004","journal-title":"Cancer Pathog Ther."},{"key":"69327_CR14","doi-asserted-by":"publisher","unstructured":"Beliz\u00e1rio, J. E., Faintuch, J. & Malpartida, M. G. Breath Biopsy and Discovery of Exclusive Volatile Organic Compounds for Diagnosis of Infectious Diseases. Front Cell. Infect. Microbiol 10, (2021). https:\/\/doi.org\/10.3389\/fcimb.2020.564194","DOI":"10.3389\/fcimb.2020.564194"},{"key":"69327_CR15","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.3390\/life15071100","volume":"15","author":"V Potievskaya","year":"2025","unstructured":"Potievskaya, V. et al. Prognostic significance of the comprehensive biomarker analysis in colorectal cancer. Life 15, 1100 (2025). https:\/\/doi.org\/10.3390\/life15071100","journal-title":"Life"},{"key":"69327_CR16","doi-asserted-by":"publisher","first-page":"188644","DOI":"10.1016\/j.bbcan.2021.188644","volume":"1877","author":"F Gouzerh","year":"2022","unstructured":"Gouzerh, F. et al. Odors and cancer: Current status and future directions. Biochim. Biophys. Acta - Rev. Cancer. 1877, 188644 (2022). https:\/\/doi.org\/10.1016\/j.bbcan.2021.188644","journal-title":"Biochim. Biophys. Acta - Rev. Cancer"},{"key":"69327_CR17","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1186\/s12889-024-18198-2","volume":"24","author":"R Dong","year":"2024","unstructured":"Dong, R. et al. Association of volatile organic compound exposure with metabolic syndrome and its components: a nationwide cross-sectional study. BMC Public. Health. 24, 671 (2024). https:\/\/doi.org\/10.1186\/s12889-024-18198-2","journal-title":"BMC Public. Health"},{"key":"69327_CR18","doi-asserted-by":"publisher","first-page":"245","DOI":"10.3390\/metabo10060245","volume":"10","author":"FW Albrecht","year":"2020","unstructured":"Albrecht, F. W. et al. Exhaled volatile organic compounds during inflammation induced by TNF-\u03b1 in ventilated rats. Metabolites 10, 245 (2020). https:\/\/doi.org\/10.3390\/metabo10060245","journal-title":"Metabolites"},{"key":"69327_CR19","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1007\/s12668-025-01876-9","volume":"15","author":"BA Taha","year":"2025","unstructured":"Taha, B. A., Addie, A. J., Haider, A. J. & Arsad, N. Nanosensors Based on Breathomics for Human Disease Diagnosis: a New Frontier in Personalized Healthcare. Bionanoscience 15, 268 (2025). https:\/\/doi.org\/10.1007\/s12668-025-01876-9","journal-title":"Bionanoscience"},{"key":"69327_CR20","doi-asserted-by":"publisher","first-page":"1461","DOI":"10.1080\/10408347.2021.1889961","volume":"52","author":"M Khoubnasabjafari","year":"2022","unstructured":"Khoubnasabjafari, M. et al. Review of Sample Collection and Analysis, Data Modeling and Clinical Applications. Crit. Rev. Anal. Chem. 52, 1461\u20131487 (2022). Breathomics. https:\/\/doi.org\/10.1080\/10408347.2021.1889961","journal-title":"Crit. Rev. Anal. Chem."},{"key":"69327_CR21","doi-asserted-by":"publisher","unstructured":"Ratiu, I. A., Ligor, T., Bocos-Bintintan, V., Mayhew, C. A. & Buszewski, B. Volatile Organic Compounds in Exhaled Breath as Fingerprints of Lung Cancer, Asthma and COPD. J Clin. Med 10, (2020). https:\/\/doi.org\/10.3390\/jcm10010032","DOI":"10.3390\/jcm10010032"},{"key":"69327_CR22","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1186\/s12931-025-03242-5","volume":"26","author":"J Tian","year":"2025","unstructured":"Tian, J. et al. Exhaled volatile organic compounds as novel biomarkers for early detection of COPD, asthma, and PRISm: a cross-sectional study. Respir Res. 26, 173 (2025). https:\/\/doi.org\/10.1186\/s12931-025-03242-5","journal-title":"Respir Res."},{"key":"69327_CR23","doi-asserted-by":"publisher","first-page":"224","DOI":"10.3390\/diagnostics9040224","volume":"9","author":"V Saasa","year":"2019","unstructured":"Saasa, V., Beukes, M., Lemmer, Y. & Mwakikunga, B. Blood ketone bodies and breath acetone analysis and their correlations in type 2 diabetes mellitus. Diagnostics 9, 224 (2019). https:\/\/doi.org\/10.3390\/diagnostics9040224","journal-title":"Diagnostics"},{"key":"69327_CR24","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1038\/s41575-024-00937-w","volume":"21","author":"AS Meijnikman","year":"2024","unstructured":"Meijnikman, A. S., Nieuwdorp, M. & Schnabl, B. Endogenous ethanol production in health and disease. Nat. Rev. Gastroenterol. Hepatol. 21, 556\u2013571 (2024). https:\/\/doi.org\/10.1038\/s41575-024-00937-w","journal-title":"Nat. Rev. Gastroenterol. Hepatol."},{"key":"69327_CR25","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.1093\/cid\/ciac859","volume":"76","author":"WM Ahmed","year":"2023","unstructured":"Ahmed, W. M. et al. Microbial Volatiles as Diagnostic Biomarkers of Bacterial Lung Infection in Mechanically Ventilated Patients. Clin. Infect. Dis. 76, 1059\u20131066 (2023). https:\/\/doi.org\/10.1093\/cid\/ciac859","journal-title":"Clin. Infect. Dis."},{"key":"69327_CR26","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.ajem.2024.11.045","volume":"88","author":"TJ van der Aart","year":"2025","unstructured":"van der Aart, T. J. et al. The smell of sepsis: Electronic nose measurements improve early recognition of sepsis in the ED. Am. J. Emerg. Med. 88, 126\u2013133 (2025). https:\/\/doi.org\/10.1016\/j.ajem.2024.11.045","journal-title":"Am. J. Emerg. Med."},{"key":"69327_CR27","unstructured":"Verhoef, P. A. Immune Dysregulation During Sepsis. in Hall, Schmidt and Wood\u2019s Principles of Critical Care, 5th Edition (eds. Schmidt, G. A., Kress, J. P. & Douglas, I. S.) (2023)."},{"key":"69327_CR28","doi-asserted-by":"publisher","first-page":"16045","DOI":"10.1038\/nrdp.2016.45","volume":"2","author":"RS Hotchkiss","year":"2016","unstructured":"Hotchkiss, R. S. et al. Sepsis and septic shock. Nat. Rev. Dis. Prim. 2, 16045 (2016). https:\/\/doi.org\/10.1038\/nrdp.2016.45","journal-title":"Nat. Rev. Dis. Prim."},{"key":"69327_CR29","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1186\/s13054-014-0529-6","volume":"18","author":"PE Marik","year":"2014","unstructured":"Marik, P. E. Don\u2019t miss the diagnosis of sepsis! Crit. Care. 18, 529 (2014). https:\/\/doi.org\/10.1186\/s13054-014-0529-6","journal-title":"Crit. Care"},{"key":"69327_CR30","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1186\/s12879-014-0593-1","volume":"14","author":"A Burillo","year":"2014","unstructured":"Burillo, A. & Bouza, E. Use of rapid diagnostic techniques in ICU patients with infections. BMC Infect. Dis. 14, 593 (2014). https:\/\/doi.org\/10.1186\/s12879-014-0593-1","journal-title":"BMC Infect. Dis."},{"key":"69327_CR31","unstructured":"Fulton, I. I., Zubair, M. R. & Taghavi, S. M. Laboratory Evaluation of Sepsis. in (Treasure Island (FL), (2026)."},{"key":"69327_CR32","doi-asserted-by":"publisher","first-page":"26012","DOI":"10.1088\/1752-7163\/ab7b8d","volume":"14","author":"G Stavropoulos","year":"2020","unstructured":"Stavropoulos, G. et al. Implementation of quality controls is essential to prevent batch effects in breathomics data and allow for cross-study comparisons. J. Breath. Res. 14, 26012 (2020). https:\/\/doi.org\/10.1088\/1752-7163\/ab7b8d","journal-title":"J. Breath. Res."},{"key":"69327_CR33","doi-asserted-by":"publisher","first-page":"116823","DOI":"10.1016\/j.trac.2022.116823","volume":"158","author":"Rui Su","year":"2023","unstructured":"Su, R. et al. Mass spectrometry for breath analysis. TrAC Trends Anal. Chem. 158, 116823 (2023). https:\/\/doi.org\/10.1016\/j.trac.2022.116823","journal-title":"TrAC Trends Anal. Chem."},{"key":"69327_CR34","doi-asserted-by":"publisher","first-page":"27104","DOI":"10.1088\/1752-7155\/8\/2\/027104","volume":"8","author":"T Fink","year":"2014","unstructured":"Fink, T., Baumbach, J. I. & Kreuer, S. Ion mobility spectrometry in breath research. J. Breath. Res. 8, 27104 (2014). https:\/\/doi.org\/10.1088\/1752-7155\/8\/2\/027104","journal-title":"J. Breath. Res."},{"key":"69327_CR35","doi-asserted-by":"publisher","first-page":"117791","DOI":"10.1016\/j.trac.2024.117791","volume":"177","author":"CM Arachchige","year":"2024","unstructured":"Arachchige, C. M. & Muller, A. Raman scattering applied to human breath analysis. TrAC Trends Anal. Chem. 177, 117791 (2024). https:\/\/doi.org\/10.1016\/j.trac.2024.117791","journal-title":"TrAC Trends Anal. Chem."},{"key":"69327_CR36","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1080\/05704928.2020.1848857","volume":"56","author":"VR N","year":"2021","unstructured":", V. R. N. et al. Breath analysis for the screening and diagnosis of diseases. Appl. Spectrosc. Rev. 56, 702\u2013732 (2021). https:\/\/doi.org\/10.1080\/05704928.2020.1848857","journal-title":"Appl. Spectrosc. Rev."},{"key":"69327_CR37","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1021\/acssensors.4c02685","volume":"10","author":"A Fern\u00e1ndez-Lodeiro","year":"2025","unstructured":"Fern\u00e1ndez-Lodeiro, A., Constantinou, M., Panteli, C., Agapiou, A. & Andreou, C. Breath Analysis via Surface Enhanced Raman Spectroscopy. ACS Sens. 10, 602\u2013621 (2025). https:\/\/doi.org\/10.1021\/acssensors.4c02685","journal-title":"ACS Sens."},{"key":"69327_CR38","doi-asserted-by":"publisher","first-page":"124181","DOI":"10.1016\/j.saa.2024.124181","volume":"314","author":"X Xie","year":"2024","unstructured":"Xie, X. et al. SERS-based AI diagnosis of lung and gastric cancer via exhaled breath. Spectrochim Acta Part. Mol. Biomol. Spectrosc. 314, 124181 (2024). https:\/\/doi.org\/10.1016\/j.saa.2024.124181","journal-title":"Spectrochim Acta Part. Mol. Biomol. Spectrosc."},{"key":"69327_CR39","doi-asserted-by":"publisher","first-page":"2320","DOI":"10.3390\/molecules28052320","volume":"28","author":"KS Maiti","year":"2023","unstructured":"Maiti, K. S. Non-Invasive disease specific biomarker detection using infrared spectroscopy: a review. Molecules 28, 2320 (2023). https:\/\/doi.org\/10.3390\/molecules28052320","journal-title":"Molecules"},{"key":"69327_CR40","doi-asserted-by":"publisher","first-page":"37108","DOI":"10.1088\/1752-7155\/5\/3\/037108","volume":"5","author":"JH Shorter","year":"2011","unstructured":"Shorter, J. H. et al. Clinical study of multiple breath biomarkers of asthma and COPD (NO, CO2, CO and N2O) by infrared laser spectroscopy. J. Breath. Res. 5, 37108 (2011). https:\/\/doi.org\/10.1088\/1752-7155\/5\/3\/037108","journal-title":"J. Breath. Res."},{"key":"69327_CR41","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1007\/s11306-017-1241-8","volume":"13","author":"O Lawal","year":"2017","unstructured":"Lawal, O., Ahmed, W. M., Nijsen, T. M. E., Goodacre, R. & Fowler, S. J. Exhaled breath analysis: a review of \u2018breath-taking\u2019 methods for off-line analysis. Metabolomics 13, 110 (2017). https:\/\/doi.org\/10.1007\/s11306-017-1241-8","journal-title":"Metabolomics"},{"key":"69327_CR42","doi-asserted-by":"publisher","first-page":"47106","DOI":"10.1088\/1752-7163\/aa7ab5","volume":"11","author":"D Smith","year":"2017","unstructured":"Smith, D. & \u0160pan\u011bl, P. On the importance of accurate quantification of individual volatile metabolites in exhaled breath. J. Breath. Res. 11, 47106 (2017). https:\/\/doi.org\/10.1088\/1752-7163\/aa7ab5","journal-title":"J. Breath. Res."},{"key":"69327_CR43","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1007\/s40291-023-00640-7","volume":"27","author":"A Sharma","year":"2023","unstructured":"Sharma, A., Kumar, R. & Varadwaj, P. Smelling the Disease: Diagnostic Potential of Breath Analysis. Mol. Diagn. Ther. 27, 321\u2013347 (2023). https:\/\/doi.org\/10.1007\/s40291-023-00640-7","journal-title":"Mol. Diagn. Ther."},{"key":"69327_CR44","doi-asserted-by":"publisher","first-page":"30625","DOI":"10.1021\/acsomega.4c02635","volume":"9","author":"N Feddahi","year":"2024","unstructured":"Feddahi, N. et al. Neonatal Exhaled Breath Sampling for Infrared Spectroscopy: Biomarker Analysis. ACS Omega. 9, 30625\u201330635 (2024). https:\/\/doi.org\/10.1021\/acsomega.4c02635","journal-title":"ACS Omega"},{"key":"69327_CR45","doi-asserted-by":"publisher","first-page":"5823","DOI":"10.3390\/molecules2524582","volume":"25","author":"Alessia Di Gilio","year":"2020","unstructured":"Di Gilio, A. et al. Breath analysis: comparison among methodological approaches for breath sampling. Molecules 25, 5823 (2020). https:\/\/doi.org\/10.3390\/molecules2524582","journal-title":"Molecules"},{"key":"69327_CR46","doi-asserted-by":"publisher","first-page":"27104","DOI":"10.1088\/1752-7163\/ac5526","volume":"16","author":"KK Bhavra","year":"2022","unstructured":"Bhavra, K. K. et al. The utility of a standardised breath sampler in school age children within a real-world prospective study. J. Breath. Res. 16, 27104 (2022). https:\/\/doi.org\/10.1088\/1752-7163\/ac5526","journal-title":"J. Breath. Res."},{"key":"69327_CR47","doi-asserted-by":"publisher","first-page":"17926","DOI":"10.1038\/s41598-022-22581-7","volume":"12","author":"P Sukul","year":"2022","unstructured":"Sukul, P., Trefz, P., Schubert, J. K. & Miekisch, W. Advanced setup for safe breath sampling and patient monitoring under highly infectious conditions in the clinical environment. Sci. Rep. 12, 17926 (2022). https:\/\/doi.org\/10.1038\/s41598-022-22581-7","journal-title":"Sci. Rep."},{"key":"69327_CR48","doi-asserted-by":"publisher","first-page":"26007","DOI":"10.1088\/1752-7155\/2\/2\/026007","volume":"2","author":"W Miekisch","year":"2008","unstructured":"Miekisch, W. et al. Impact of sampling procedures on the results of breath analysis. J. Breath. Res. 2, 26007 (2008). https:\/\/doi.org\/10.1088\/1752-7155\/2\/2\/026007","journal-title":"J. Breath. Res."},{"key":"69327_CR49","doi-asserted-by":"publisher","unstructured":"Lomonaco, T. et al. A breath sampling system assessing the influence of respiratory rate on exhaled breath composition. In: 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) 7618\u20137621 (IEEE, 2015). https:\/\/doi.org\/10.1109\/EMBC.2015.7320156","DOI":"10.1109\/EMBC.2015.7320156"},{"key":"69327_CR50","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1586\/14737159.4.5.619","volume":"4","author":"JK Schubert","year":"2004","unstructured":"Schubert, J. K., Miekisch, W. & Geiger, K. N\u00f6ldge\u2013Schomburg, G. F. E. Breath analysis in critically ill patients: potential and limitations. Expert Rev. Mol. Diagn. 4, 619\u2013629 (2004). https:\/\/doi.org\/10.1586\/14737159.4.5.619","journal-title":"Expert Rev. Mol. Diagn."},{"key":"69327_CR51","doi-asserted-by":"publisher","first-page":"36004","DOI":"10.1088\/1752-7163\/ad4736","volume":"18","author":"B Czippelov\u00e1","year":"2024","unstructured":"Czippelov\u00e1, B. et al. Impact of breath sample collection method and length of storage of breath samples in Tedlar bags on the level of selected volatiles assessed using gas chromatography-ion mobility spectrometry (GC-IMS). J. Breath. Res. 18, 36004 (2024). https:\/\/doi.org\/10.1088\/1752-7163\/ad4736","journal-title":"J. Breath. Res."},{"key":"69327_CR52","doi-asserted-by":"publisher","first-page":"8","DOI":"10.3390\/metabo13010008","volume":"13","author":"K Westphal","year":"2023","unstructured":"Westphal, K. et al. Common strategies and factors affecting off-line breath sampling and volatile organic compounds analysis using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). Metabolites 13, 8. https:\/\/doi.org\/10.3390\/metabo13010008 (2023).","journal-title":"Metabolites"},{"key":"69327_CR53","doi-asserted-by":"publisher","first-page":"6435","DOI":"10.1007\/s00216-019-02024-5","volume":"411","author":"M Zhou","year":"2019","unstructured":"Zhou, M. et al. Rapid breath analysis for acute respiratory distress syndrome diagnostics using a portable two-dimensional gas chromatography device. Anal. Bioanal Chem. 411, 6435\u20136447 (2019). https:\/\/doi.org\/10.1007\/s00216-019-02024-5","journal-title":"Anal. Bioanal Chem."},{"key":"69327_CR54","doi-asserted-by":"publisher","first-page":"1454","DOI":"10.1016\/j.rmed.2015.09.014","volume":"109","author":"RM Schnabel","year":"2015","unstructured":"Schnabel, R. M. et al. Electronic nose analysis of exhaled breath to diagnose ventilator-associated pneumonia. Respir Med. 109, 1454\u20131459 (2015). https:\/\/doi.org\/10.1016\/j.rmed.2015.09.014","journal-title":"Respir Med."},{"key":"69327_CR55","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1364\/OE.536543","volume":"33","author":"C Hofer","year":"2025","unstructured":"Hofer, C. et al. Linear field-resolved spectroscopy approaching ultimate detection sensitivity. Opt. Express. 33, 1\u201317 (2025). https:\/\/doi.org\/10.1364\/OE.536543","journal-title":"Opt. Express"},{"issue":"8052","key":"69327_CR56","doi-asserted-by":"publisher","first-page":"941","DOI":"10.1038\/s41586-024-08534-2","volume":"638","author":"Q. Liang","year":"2025","unstructured":"Liang, Q., Bisht, A., Scheck, A., Schunemann, P. G. & Ye, J. Modulated Ringdown Comb Interferometry for next-generation high complexity trace gas sensing. https:\/\/doi.org\/10.1038\/s41586-024-08534-2","journal-title":"Nature"},{"key":"69327_CR57","doi-asserted-by":"publisher","first-page":"1562","DOI":"10.3390\/s18051562","volume":"18","author":"Y Saalberg","year":"2018","unstructured":"Saalberg, Y. & Wolff, M. Multivariate analysis as a tool to identify concentrations from strongly overlapping gas spectra. Sensors 18 1562 https:\/\/doi.org\/10.3390\/s18051562 (2018).","journal-title":"Sensors"},{"key":"69327_CR58","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/S0169-7439(01)00155-1","volume":"58","author":"S Wold","year":"2001","unstructured":"Wold, S., Sj\u00f6str\u00f6m, M. & Eriksson, L. PLS-regression: a basic tool of chemometrics. Chemom Intell. Lab. Syst. 58, 109\u2013130 (2001). https:\/\/doi.org\/10.1016\/S0169-7439(01)00155-1","journal-title":"Chemom Intell. Lab. Syst."},{"key":"69327_CR59","doi-asserted-by":"publisher","first-page":"11035","DOI":"10.1021\/acs.analchem.0c00075","volume":"92","author":"A Zifarelli","year":"2020","unstructured":"Zifarelli, A. et al. Partial least-squares regression as a tool to retrieve gas concentrations in mixtures detected using quartz-enhanced photoacoustic spectroscopy. Anal. Chem. 92, 11035\u201311043 (2020). https:\/\/doi.org\/10.1021\/acs.analchem.0c00075","journal-title":"Anal. Chem."},{"key":"69327_CR60","doi-asserted-by":"publisher","unstructured":"Hastie, T., Tibshirani, R. & Friedman, J. The Elements of Statistical Learning: Data Mining, Inference, and Prediction (Springer, 2009). https:\/\/doi.org\/10.1007\/978-0-387-84858-7","DOI":"10.1007\/978-0-387-84858-7"},{"key":"69327_CR61","unstructured":"Gries, W., Scherer, G., Bader, M., G\u00f6en, T. & Hartwig, A. The determination of detection and quantitation limits in human biomonitoring. MAK Collect. Occup. Heal Saf. 9, (2024)."},{"key":"69327_CR62","doi-asserted-by":"publisher","first-page":"486","DOI":"10.2307\/2290328","volume":"88","author":"J Shao","year":"1993","unstructured":"Shao, J. Linear Model Selection by Cross-validation. J. Am. Stat. Assoc. 88, 486\u2013494 (1993). https:\/\/doi.org\/10.2307\/2290328","journal-title":"J. Am. Stat. Assoc."},{"key":"69327_CR63","first-page":"2825","volume":"12","author":"F Pedregosa","year":"2011","unstructured":"Pedregosa, F. et al. Scikit-learn: Machine learning in Python. J. Mach. Learn. Res. 12, 2825\u20132830 (2011).","journal-title":"J. Mach. Learn. Res."},{"key":"69327_CR64","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/S0378-3812(96)03126-3","volume":"126","author":"P Oracz","year":"1996","unstructured":"Oracz, P., G\u00f3ral, M., Wilczek-Vera, G. & Warycha, S. Vapour-liquid equilibria. X. The ternary system cyclohexane-methanol-acetone at 293.15 and 303.15 K. Fluid Phase Equilib. 126, 71\u201392 (1996). https:\/\/doi.org\/10.1016\/S0378-3812(96)03126-3","journal-title":"Fluid Phase Equilib."},{"key":"69327_CR65","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1016\/0378-3812(87)87010-3","volume":"33","author":"RA Wilsak","year":"1987","unstructured":"Wilsak, R. A., Campbell, S. W. & Thodos, G. Vapor\u2014liquid equilibrium measurements for the n-pentane\u2014methanol\u2014acetone ternary at 372.7 K and their prediction from the constituent binaries. Fluid Phase Equilib. 33, 173\u2013190 (1987). https:\/\/doi.org\/10.1016\/0378-3812(87)87010-3","journal-title":"Fluid Phase Equilib."},{"key":"69327_CR66","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.saa.2006.02.028","volume":"66","author":"MR Jalilian","year":"2007","unstructured":"Jalilian, M. R. Spectra and structure of binary azeotropes: Ii. acetone\u2013n-pentane. Spectrochim Acta Part. Mol. Biomol. Spectrosc. 66, 91\u201393 (2007). https:\/\/doi.org\/10.1016\/j.saa.2006.02.028","journal-title":"Spectrochim Acta Part. Mol. Biomol. Spectrosc."},{"key":"69327_CR67","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1038\/s41566-022-01057-0","volume":"16","author":"P Sulzer","year":"2022","unstructured":"Sulzer, P. et al. Cavity-enhanced field-resolved spectroscopy. Nat. Photonics. 16, 692\u2013697 (2022). https:\/\/doi.org\/10.1038\/s41566-022-01057-0","journal-title":"Nat. Photonics"},{"key":"69327_CR68","doi-asserted-by":"publisher","unstructured":"Muraviev, A., Smolski, V. O., Loparo, Z. E. & Vodopyanov, K. L. Optica Publishing Group,. Massively parallel sensing of trace molecules with broadband mid-infrared subharmonic frequency combs. in Frontiers in Optics \/ Laser Science LTh3F.3 (2018). https:\/\/doi.org\/10.1364\/LS.2018.LTh3F.3","DOI":"10.1364\/LS.2018.LTh3F.3"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-69327-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-69327-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-69327-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T15:49:08Z","timestamp":1788536948000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-026-69327-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,4]]},"references-count":68,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["69327"],"URL":"https:\/\/doi.org\/10.1038\/s41598-026-69327-3","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,4]]},"assertion":[{"value":"9 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"27809"}}